The Mikrofill Electronic Filling Device. (EFD)

Similar documents

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

Datasheet. Flamcomat - Pressureless Expansion System

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves

Installation & Technical Guide. Domestic & Commercial.

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

Pent-A-Boost Compact Domestic Booster Sets

REVISION HISTORY REVISION HISTORY

Operating & Maintenance Manual Break Tank & Pump Set Model BTAB Arrow Valves

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

XT INSTRUCTION MANUAL

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

EMERGENCY VEHICLE BATTERY MANAGER PS2024

MANIFOLDS & WATER TEMPERATURE CONTROL

30GX AIR-COOLED LIQUID CHILLER

Flight Systems. Replacement for KASSEC DESCRIPTION

30GX AIR-COOLED LIQUID CHILLER

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

To ensure proper installation, digital pictures with contact information to before startup.

ECONOPLATE EJA/EJB/ESC HOT WATER SERVICE PACKAGED PLATE HEAT EXCHANGERS



Battery, Mounting and Cables - Battery and Cables Description and Operation

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Installation and Operations Manual

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

CONTROLLER DIAGNOSTIC GUIDE

Air-Cooled Liquid Chiller with integrated hydraulic module

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Uninterruptible Power System

IRC urinal flush control valve

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

ELECTRICAL SYSTEM RP-7

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

IRC Urinal Flush Control Valve

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Table of Contents 1 SYSTEM OVERVIEW GENERAL ARRANGEMENT AND OPERATION INSTALLATION MECHANICAL INSTALLATION 7

2002 Buick Rendezvous - AWD

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide

AQUAMATIC HY-AV 2020Plus SERIES

Mild Steel Dosing Pots

PRECISION UK Ltd DUPLEX AGSS PLANT

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Heating and Gas Installations - December 2014

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

TECHNICAL INFORMATION

#PIP4862A: Service Rear Axle Message Displayed DTC C0407 Sym64 - (Sep 21, 2011)

DIESEL Engine Fire Pump Controllers Features

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Product Data. Features/Benefits

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

Cruise Control Diagnosis

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

HWP Protection Board

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

P od o u d c u t line n : S B S B Inv n erter N I P P r P esent n ation

BSS Examination Record Form for Privately Owned and Managed Vessels

Automatic DC Power Supply/Battery Charger

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Transfer Control Device

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

Operation & Maintenance Manual

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

CRUISE CONTROL SYSTEM

Boost-A-Break - Break Tank & Booster Sets

Sentry Battery Charger. Installation and Operations Manual Section 75

CPX DUPLEX MEDICAL VACUUM PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation/Care/Use Manual

RVS-DN Digital Reduced Voltage Motor Starter

4.2 Component Identification

ZonePlus Z322 zone valve Installation and commissioning instructions

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

SCHEMATIC AND ROUTING DIAGRAMS

Mira Vier Dual. These instructions must be left with the user. User Guide

Transcription:

The Mikrofill Electronic Filling Device. (EFD) The Mikrofill EFD is a fully automatic sealed system filling device, and is suitable for the water management in all domestic and commercial heating and cooling systems. It is supplied as a fully commissioned unit and should require no on site commissioning. INSTALLATION All Mikrofill products should be installed by a competent person with regard to the relevant requirements of the Health and Safety Regulations, Building Regulations, IEE Regulations, Water Supply (water fittings) Regulations, Water Byelaws (Scotland) and any other local bye-laws or planning requirements, the Mikrofill EFD is Wras approved - certificate No 0201032. The Mikrofill EFD is intended for wall mounting and there are four mounting holes on the backplate for this purpose, the unit should be mounted at such a height as to enable the Liquid crystal display to be easily read, Water connections - Mains cold water inlet The Mikrofill EFD is designed to be connected directly to the mains cold water supply, or a boosted cold water supply, the unit is supplied complete with all necessary isolating valves, and incorporates a basket filter in the inlet ball valve. The water inlet is 15mm compression and should be connected to the mains cold water supply by 15mm copper tube or equivalent approved plastic pipework. If the Mikrofill EFD is sited some distance from the mains cold water supply it may be advisable to install a single check valve adjacent to the mains cold water supply. To reduce the pressure drop on very long supply routes then 22mm supply pipework is recommended. Dimensions The size of the EFD is 260w x 270h x 150d and the weight is 8kg

System pipework - Outlet The Mikrofill EFD is connected to the system by way of the integral 15mm outlet valve, the pipework from the unit should be made in 15mm copper or similarly approved plastic pipework. A suitably sized expansion vessel should be incorporated into the system at this point. If you require any assistance regarding vessel sizing please contact our technical sales department. The final connection into the heating (or cooling ) system should be sized accordingly, recommendations are shown below: Vessel size up to 100L Vessel size up to 300L Vessel size up to 750L ½ (15mm) expansion pipework. ¾ (22mm) expansion pipework 1 (28mm) expansion pipework. For vessel sizes in excess of 750L capacity please contact our technical sales department.. IMPORTANT NOTE 1 The Mikrofill EFD is supplied fitted with a ¾ tundish, which must be connected to a suitable drain. IMPORTANT NOTE 2 The expansion vessel Nitrogen/air charge must be set at the same pressure as the cold fill pressure of the system. All Mikrofill vessels are factory commissioned to the correct pressure Electrical connections The Mikrofill EFD requires a permanent 240V 50 Hz 1 phase supply rated at 3 amp, the unit is internally fused at 3 amp see electrical installation diagram. The EFD also incorporates two BMS relays offering volt free contacts for the remote indication of high or low pressure conditions within the heating or cooling system. These relays are also independently fused at 5 amp to protect the Mikrofill EFD from external electrical faults. A further volt free relay is included in the EFD this is to interlock the boiler or chiller control circuits, should either of the alarm relays operate then the boiler/chiller relay will shut down the boiler or chiller, indication of any alarm situation will be indicated on the display the relays are suitable for use all control voltages up to 240V

Once the Mikrofill EFD has been connected as above the unit is ready for use, ensure that the EFD has a water supply, the EFD service valve is open. Check for water leaks, switch on electrical supply to the unit and the illuminated on/off switch to the left hand side of the unit, the unit will start to fill the system. Alarm Conditions Please note the EFD is a factory pre-commissioned product, should you require to change any of the preset parameters when the unit is installed please contact our technical dept. System inhibited The EFD continuously monitors the inlet water pressure, if this pressure falls to below an acceptable level then the unit will operate a safety shut down. When water pressure is reinstated the unit will automatically reset. If water pressure remains low clean the inlet filter and check the incoming water supply. Flood alert The EFD can differentiate between normal system fill rates and excessive water demand usually due to a flood condition. If this situation occurs the EFD will shut down, and issue a flood alert warning on the LCD. Flood alert reset This alert must be reset manually, by switching off the EFD waiting 30 seconds and switching back on, if the leak has been rectified the unit will then operate as normal. High or low pressure alarms If, for any reason the system water pressure reaches a high or low condition, as determined by the preset parameters the EFD will show the alarm message the relevant BMS relay will operate and the Boiler/chiller control relay will operate, shutting down the boiler or chiller, when normal operating pressure is resumed the unit will automatically reset, Frequent use alarm This alarm is to assist in diagnosing any leaks that may be present in the heating (or cooling system). If in any 24 hr period the EFD operates more than a preset limit i.e. 5, then a frequent use alarm will show, (the operation of the system will not be affected, this function is for information only). Frequent use reset this is achieved by switching the power supply to the unit off and on again Hours run facility, this is accessed by scrolling the system data button

Hours run reset this is achieved by depressing the simultaneously The EFD has a predetermined fill rate of 14 litres per minute, therefore, by multiplying the fill rate by the hours run the water usage can be calculated. Fault Diagnosis System faults will be apparent from the alarm message displayed, the EFD itself has a full self diagnostic microprocessor unit which continually self checks the operation, if an internal fault is diagnosed then the fault will be displayed on the screen, e.g. sensor disconnected In the unlikely event of a unit fault, please contact our technical department. MAINTENANCE EFD - The inlet filter which is housed in the service valve should be checked and cleaned annually. EXPANSION VESSELS Charge pressure should be checked annually when the system is cold (the charge must equal the cold fill pressure of the EFD).