RADIO FREQUENCY SYSTEMS

Similar documents
SITESTAR ELECTRONICS CABINET DESCRIPTION

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Series 3730 Electropneumatic Positioner Type

User Manual Solar Charge Controller 3KW

Technical Specification SENTINEL PRO

PowerView PV380-R2 Mechanical Configuration

Switching DC Power Supply

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Section 3 Technical Information

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Superstatic 440. Static Heat- and Cooling Meter. Application

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

ECONOMISER SERIES E2T USER MANUAL

Three-Phase Soft Starters

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ECLIPSE Laundry Dispenser Controller

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Diesel Generator Set S3.8 Series Engine

3 Phase Smart Controller

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

up to 63 A (1 module per pole)

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

ULTRASONIC FLOW SENSOR IFX-M4-01

Phoenix Inverter

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

TIMER INTERFACE USER MANUAL

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Short Form Guide. Unidrive SP. Part Number: Issue: 2.

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

A419ABG-3C Electronic Temperature Control

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Model H30 Operation Manual

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

Liebert PowerSure PSI UPS

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

REVISION HISTORY REVISION HISTORY

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Pressure Sensors. for liquid and gaseous media

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Power+ CLASSIC. 20/30 kva, 3x208 Vac

HERZ Motorised Actuator

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Pulsar EXtreme 2200C / 3200C

DIESEL Engine Fire Pump Controllers Features

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

M Technical Specification No. for the supply of Battery Charger. Israel Railways Ltd. Rolling Stock Division

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Differential Pressure Switch QBM81-

Heavy Duty Series (HDS) Installation and user guide

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Heat Meter Integrator

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

PowerCommand 2100 digital generator set control

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

ECCII to ECCIII Upgrade Kit

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Flash Point Process Analyzer

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

Transcription:

C14520.016-E.MU0 DOC.:10000008168-02 LAB4 DEHYDRATOR USER MANUAL 1 DRYING CHAMBER 2 HEATER 3 PUMP 4 AIR BACKWASHING HOLE 5 HUMIDITY PROBE 6 DIGITAL PRESSURE GAUGE 7 RELIEF VALVE 8 SHUT OFF VALVE 9 DRY AIR OUTLET 10 FLOW FKMETER (OPTIONAL) Radio Frequency Systems www.rfsworld.com Germany +49 511 676-2000 United States +1 800 321-4700 Australia +61-3-9751-8400 Brazil +55-11-4785-2433 China +86-21-3773-8888 Neither this document nor any part of it shall be published, reproduced, copied or made known without the written authorization by Radio Frequency Systems.

1. FEATURES Output pressure : programmable from 1 kpa to 6 kpa Maximum flow rate : 300 liter per hours Safety valve : factory set at 7 kpa 10 % Output air dew point : better than - 45 C, @ 20 C ambient temperature, 80% Relative Humidity Desiccant regeneration : automatic by heating Regeneration phase interval : adaptive according to plant leakages Local alarms : power and system failures, low/high pressure, high humidity Remote alarms : the summary alarm is remotely signaled by a SPDT relay Remote monitoring interface : 10/100 Mbit Ethernet, auto-sensing (optional) Low pressure alarm : factory set at 1 kpa, programmable from 0,5 kpa High pressure alarm : factory set at 6 kpa, programmable up to 7 kpa High humidity alarm : set at 10% of relative humidity 2% Standard measures : air pressure, hour meter Optional measures : air flow by electronic flowmeter Led indications : power on, alarms Acoustic noise : 50 dba at 1 m far and 1,5 m height Enclosure degree of protection : IP20 according to IEC529 Operating temperature : -10 C + 50 C Storage temperature : -30 C + 60 C Power supply : 48 / 60 Vdc (from 36 to 72 Vdc) 100 240 Vac, 50/60 Hz (from 90 to 264 Vac), with apposite power supply kit code K14524 Power consumption : < 3 W (at steady state without system leakage) < 55 W (during regeneration phase) Dimensions (mm) : 19 rack mounting 132 mm (H), 482 mm (W), 238 mm (D) ETSI N3 rack mounting 135 mm (H), 533 mm (W), 238 mm (D) Wall and 19 rack mounting 132 mm (H), 482 mm (W), 278 mm (D) Weight : about 6,5 kg PAGE 1

Standard outlets : 4 or 8 outlets, each with ON/OFF valve Outlets fitting : 7 mm diameter, others on request Shock and vibration Transportation Stationary use Low Voltage Directive : 2006/95/EC Electromagnetic Compatibility Directive : 2004/108/EC : : Safety Normative : IEC/EN 60950-1 Conform to ETSI EN 300 019-1-2, Class 2.3 Conform to ETSI EN 300 019-1-3, Class 3.1E Electromagnetic Compatibility Normative : EN 55022 class A and B EN 61000-6-1 ETSI EN 301 489-1 ANSI CFR 47 part 15 Marking and Certification : Certified to CB, test ref. n SE-64590 Environmental compliance : 2011/65/EC (RoHS2) 1907/2006 (REACH) Quality assurance standard : ISO 9001 PAGE 2

2. DESCRIPTION The LAB4 dehydrator is designed for continuous operation and automatic duty. It supplies dry air up to 300 l/h with dew point better than -45 C. Output pressure is selectable within the range from 1 kpa to 6 kpa with 0,1 kpa step. Dry air is vented by four or eight standard independent air outlets with hose-tail fittings accessible from the back side of the equipment. Each outlet has a dedicated shutoff valve and one or two flow meters (one for each group of four outlets) can be supplied on request. Air drying is performed by means of two drying towers containing granular substances. While one tower dries (incoming air from releases most of its molecules of water by adsorption) the other one is regenerated by heating and backwashing with a reverse dry air flow. The electronic microprocessor board controls drying cycles and adjusts cycles duration according to plant air needs. Air is compressed by two diaphragm pumps. A fundamental feature of the LAB4 dehydrator is the continuous tracking of output pressure. The PWM (Pulse Width Modulation) technique is used to control the speed of two pumps (one for each drying tower) so to optimize pump duty, power consumption, acoustic noise, and improve reliability. Pumps speed control eliminates mechanical pressure regulators that introduce undesirable pressure losses and a worst response to flow needs. The equipment is designed for wall, 19" and ETSI N3 standard racks mountings. The LAB4 dehydrator does not require pre-settings nor warm up time before startup. It does not require preventive maintenance. For startup see 3.3. No radioactive or chemically hazardous components are used. The following devices are available on the front panel: display (2 x 16 characters). Output air pressure, hour meter, active alarm messages, output pressure and low/high pressure alarm thresholds setting are available two function keys ( e ) to scroll and modify setting one bi-color power on and alarms LED (see 3.4) shut off outlet valves On the rear panel are accessible: power supply connector remote alarm connector outlets with hose-tail fittings according to the equipment configuration. The following item are available as option: 10/100 Mbit Ethernet interface for remote control, the RJ45 connector is available on the rear panel electronic flowmeter with data showed on the display PAGE 3

3. INSTALLATION The LAB4 dehydrator is designed for wall mounting and for both 19 standard rack and N3 standard frame mountings. The equipment is factory assembled for the 19 rack mounting. It is strongly suggested to place the LAB4 in the upper part of the rack without any other equipment above. If the LAB4 cannot be placed in the upper part of the rack, it is mandatory to leave an upper free space of at least one unit from the dehydrator to the closest equipment. 19 Rack Mounting Before proceeeding, make sure of the correct mounting of the cover as illustrated in the image on the left. If not, unscrew the cover of the LAB4 and rotate it by 180. Fix the top cover to the case with screws. Put the dehydrator into the rack and lock it with the screws supplied in the ancillary kit. ETSI rack mounting Make sure of the correct mounting of the cover as required for the 19 rack mounting configuration. See above. Tighten the ETSI-N3 brackets with the same screws used for rack 19 rack mounting Put the dehydrator into the frame and lock it with the screws supplied in the ancillary kit. Wall mounting Make sure of the correct mounting of the cover as illustated in the image on the left. If not, unscrew the cover of the LAB4 and rotate it by 180. Fix the top cover to the case with screws. Connect alarm connector, power supply connector and pipes to the LAB4 air outlets; then lock the dehydrator to the wall with the screws supplied in the ancillary kit. PAGE 4

Pneumatic connections The LAB4 has four or eight air outlets available on the rear side. Each outlet is equipped with a shutoff valve on the front side. Open, by pulling relevant knob, only valves corresponding to used outlets, keep all the others closed by pushing relevant knob. Electrical connections Two male connectors are placed on the rear side: J1, 3 pin D-sub-3W3-C, for DC power connection; J2, 9 pin IEC48B D series, for remote alarm output. Power connection An appropriate disconnect device shall be provided as part of the building installation. Disconnect the dehydrator from the supply for servicing. Protection for short-circuit and earth failures of power conductors is a function assigned to installation area system. The dehydrator requires a protective and functional earthing. The earthing terminal is available in the power supply connector and it is marked with the symbol Note: protective earthing is mandatory only for power supply above 60Vdc. Functional earthing is always necessary. Check for correct type, polarity and rated voltage range: power rating is indicated on the LAB4 rear side. Connect Power cable wires to the J1 connector according to the following pinout. It is recommended to use at least 0,5 mm 2 wires. J1 - power terminal board pinout Pin number Label Function A1 + positive power supply input A2 Protective earthing A3 - negative supply input PAGE 5

Solder the supply cables on the solder cup sockets and the earthing cable on the solder cup plug, put pins in the connectors as shows the following pictures respecting the right polarity (earthing pin is the central one). Insert the connector in the protective shell. Fixed connector Matching mobile connector An apposite power supply adapter kit can be provided (K14524) if LAB4 is intended to be used with AC power supply. Note: When using adapter kit, protective and functional earthing is not necessary. Remote alarm output connection A summary (OR) alarm is provided by an internal SPDT (Single Pole Double Throw) relay contacts. The maximum switching current is 0,5 A dc/ac. The maximum switching voltage is 60 Vdc or 42 Vac. Note: in case of power failure the relay switches to alarm position. Remote alarm connector, 9 pin IEC48B D series, is located on the rear panel. Connect the alarm transmission wires according to the following pinout: J2 - alarm connector pinout Pin number Function 1 Closed on alarm 5 Common 6 Open on alarm PAGE 6

3.3 First startup, switch on and switch off Open all the valves corresponding to the used air outlets before proceeding with first start up. Once the dehydrator is powered, after a few seconds, dry air starts flowing out of the outlets. Depending on the volume of user system to be pressurized, it may take some time for the output pressure to achieve factory set value. Dehydrator pressure alarms are enabled after 20 sec. from power on; then low pressure alarm is hold until the target pressure is met. At the very first startup, it is recommended to purge the transmission line with dry air by keeping open the opposite side of the pressurized line for a period of time given by following formula: purging time (hours) = (3 x V) / 100 Where V is the pressurized plant volume in liters. Close the opposite side of the pressurized plant after purging time. Alarms must be ignored during the purging phase. 3.4 LED indicator The front LED is solid green during normal operation and changes red when one alarm (or more) occurs. 3.5 Alarms description - SYSTEM FAILURE means a failure of the electronic control logic. The dehydrator is not working properly and must be replaced or repaired. - LOW PRESSURE means pressure is lower than the low pressure alarm threshold value (see 1 - Features). Possible cause is excessive output air leakages. Low pressure alarm is enabled 20 second after power on. - HIGH PRESSURE means that pressure is higher than the high pressure alarm threshold value (see 1 - Features). In case of leakageless user system, possible cause of this alarm is the air thermal expansion. High pressure alarm is enabled 20 second after power on. - HIGH HUMIDITY means output air flow has a Relative Humidity over 10%. This alarm can turn on at first start-up if the dehydrator has been stocked for weeks in humid place; in this case the alarm will disappear within 24 hours after start-up. During normal operation, this alarm indicates a dehydrator failure. High humidity alarm is enabled 30 minutes after power on. PAGE 7

4. MENU FUNCTIONS A powerful low-power microcontroller is used. This choice, together with the adoption of a display and two function keys, allows user to get information and to set some parameters such as output pressure and alarm thresholds. Settings are arranged in pages displayed on the LCD and user can flip through pages by pressing the key. On startup the following main page 1 (permanent page) is displayed. In this page the operating gauge pressure and the hour meter value are showed: P r e s s u r e 2. 0 k P a h o u r m e t e r 0 0 3 1 2 The first row displays the operating gauge pressure (kpa) and the example shows that running measured pressure is 2 kpa. The second row shows the hour meter value. The example shows the LAB4 dehydrator has been running for 312 hours long. Press the key per hours. Press the key to get optional information showed in the second row like air flow liter to return to hour meter reading. When alarm(s) is active, the hour meter value is no more displayed and the proper alarm message is shown: P r e s s u r e 1. 0 k P a L O W P R E S S U R E This example illustrates that the operating gauge pressure is 1 kpa (low pressure factory default threshold is 1,5 kpa). The string LOW PRESSURE is the alarm message related to the low pressure condition. Simultaneously, the bi-color LED lights blinking red (see 3.4). HIGH PRESSURE, HIGH HUMIDITY are the messages related to high pressure and high humidity alarms. When more than one alarm is active, the strings related to the pending alarms alternate one each other on the second row of the display (five second clock track). 1 A new page appears on the display when the key is pressed. LAB4 provides auto return to main page from any other one (secondary pages). The timeout is fixed in one minute. At any pressing of the key, user scrolls all the available service pages (secondary pages) until main page is selected again. PAGE 8

4.1. Pressure and alarm threshold settings Press the key the display: to gain the pressure target setting page. The following screen appears on P r e s s u r e s e t p o i n t : 2. 0 k P a The example says the target pressure is 2 kpa. Press the key to increase the pressure target with fixed step of 0.1 kpa. Only increment key is provided. When the maximum selectable value is reached (6 kpa), the minimum allowable value (1 kpa) is automatically displayed at the next key pressing. The value will increase automatically keeping the key pressed down. Press the key setting 2. Press twice the key to scroll to the next service page to enter the new target pressure to reach low pressure setting page directly from the main page: L o w p r e s s u r e a l a r m : 1. 5 k P a The example says that the low pressure alarm threshold is set at 1.5 kpa. Press the key to increase the low pressure threshold with 0.1 kpa fixed step. Increment function key only is provided. When the maximum value is reached (target pressure, selected in the previous page, minus 0.2), the minimum allowable value (0.1 kpa) is automatically displayed at the next key pressing. The value will increase automatically keeping the key pressed down. Press the key to enter the new low pressure threshold and to scroll to next service page (if enabled, the High pressure setting menu is displayed; otherwise the main page appears on the screen). Press three times the key the main page: to reach the optional high pressure setting page directly from H i g h p r e s s u r e a l a r m : 4. 5 k P a The example says that the high pressure alarm threshold is set at 4.5 kpa. Press the key to increase the displayed value. When the maximum value of 6.3 kpa is reached, the target pressure value + 0.2 kpa is automatically displayed at the next key pressing. The value will increase automatically keeping the key pressed down. Press the key to enter the new high pressure threshold and to return to main page. 2 in order to avoid unwanted changes in the operating pressure, target pressure is not modified until exiting setting page. PAGE 9

5. CORRECTIVE MAINTENANCE AND SPARE PART The dehydrator does not require any preventive maintenance. In case of dehydrator failure please contact Radio Frequency Systems Customer Service (see first page) and give an account on the failure circumstances. In case of servicing made by the customer itself, Radio Frequency Systems will supply the necessary spare parts and support. Servicing does not require specialized personnel; a standard tool outfit for similar equipments is required. No setting-up or calibration is needed. In case of servicing, it is mandatory to keep the following in mind: CAUTION: an appropriate disconnect device shall be provided as part of the building installation. Disconnect the dehydrator from the supply for servicing. CAUTION: due to the high temperature of some parts (purposely marked) inside the dehydrator, it is mandatory to wait for at least one hour after the switch-off, before servicing inside. A list of spare parts available at service stock is given in the following table: (Note: always mention the equipment P/N or S/N on orders) Description Cibred Sud Code Electronic boards C14630.003 Humidity detector C5472 Diaphragm pump 2PPBA747016S Drying tower C14516 Optional add-on Description AC/DC power supply adapter kit Cibred Sud Code K14524 Note: K14524 power supply kit allows AC Power Supply from 90 to 264 Vac 50/60 Hz. PAGE 10

6. OUTLINE PAGE 11