TYPE 5867 PORTABLE Q METER

Similar documents
DIGITAL MICROHMMETER TYPE DO7

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Issue 2.0 December EPAS Midi User Manual EPAS35

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

ROTARY CAM SWITCHES CAM SERIES. User Manual - Issue 1.1

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

QTFX-F1, QTFX-F2 FLAME EFFECT

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

SIGMA SERIES DE METER

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Uninterruptible Power System

Uninterruptible Power System

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

PANcharge1k Battery Charger User's Manual

Autoranging Multimeter

PSU1 Power Supply Unit

Uninterruptible Power System

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

B-RAD Select USER MANUAL TABLE OF CONTENTS

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Seeker HL Source Transmitter. User s Guide

PLATINUM SERIES SWITCHBOARD METERS

BM kv Digital Insulation Tester USER MANUAL

JANDS DD-8. Technical Manual. Version 1.0

TCS 1200 Portable Temperature Calibrator

Multi-colour LED Status Light - using it as a diagnostic tool:

Emergency lighting units EM series

Envirotainer RAP e2 Container Operations Manual

True RMS Autoranging Multimeter

Installation and Connection: Installation and Operating Manual

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Fiber Optic Illuminator. Model 21AC Model 21DC

Time Electronics Ins-Cal. Insulation Tester Calibration System. Technical Manual

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

c-go 24V/6A 24V/8A 24V/12A

ThunderION. Static Neutralising System. GB User's Manual 2

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Electronic Ballast EVG 2000-T

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

USER MANUAL MPS 1-5KW SERIES

Installation, Operation & Maintenance Instructions 250 C Laboratory Fan Ovens Apex Range models AX30, AX60 & AX120

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

USERS MANUAL MCD REMOTE OPERATOR

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

GL1200T Cut & Seal. (GL1200 Seal only)

Emergency lighting units EM powerled

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Harris IRT Enterprises Digital Resistance Tester Model XP

INTECH Micro 2300-RTD6

3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual Rittal PMC UPS 6kVA

Installation and Operation Back-UPS BX550CI-CN

KANEAUTO 4-4 & KANE AUTO 5-4

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

ECONOMISER SERIES E2T USER MANUAL

TIMER INTERFACE USER MANUAL

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Emergency lighting units EM powerled

Tail Flick Analgesia Meter Users Manual. Hot Plate Analgesia Meter START STOP HARVARD. Temperature C. Time h.mm.ss HARVARD APPARATUS

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Date received into service; / /.


Mini Multimeter with Non-Contact Voltage Detector (NCV)

Emergency lighting units EM powerled

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

HIGH POWER SOLENOID DRIVER 1

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Signet Temperature Transmitter

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

WP37 & HT37 User Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

OCS-T High Resolution Digital Crane Scale

Declaration of Conformity

SIGNET Temperature Transmitter

Xenon Fiberoptic Lightsource

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Transcription:

IMPORTANT: Please read these instructions carefully before operating instrument SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference TINSLEY, A DIVISION OF HARTEST PRECISION INSTRUMENTS LTD

CONTENTS CHAPTER PAGE 1. Introduction 2 2. Safety 2 3. Case Design 3 4. Specification 3 5. Maintenance 4 6. Battery Charging 4 7. Operation 5 8. Remote 7 1. INTRODUCTION The 5867 is an accurate bench/portable digital Q meter for the measurement of the Q value of wound components, e.g. Transformers and rotating electrical machine windings. This provides the ability to determine the presence of shorted turns in a winding. The Q value may be described as a figure reflecting the resonance of the inductance, capacitance and resistance components of the transformer under test. The measured values are displayed on a 8-Digit high visibility dot matrix display. The 5867 utilises simple button operation and features warning lights which are illuminated when appropriate. Accessories supplied as standard: 1 mains cord 1 operating instructions (English) 2 test leads (colour coded), length 3m each, supplied with selection of connectors When unpacked, inspect for physical damage and report any defects immediately in writing, retaining packaging materials for inspection. This unit has been designed to operate at different mains voltages, ranging from 90 260V AC. 2. SAFETY This apparatus is designated Safety Class I as defined in the IEC publication 348. This apparatus has been designed and tested in accordance with IEC Publication 348, entitled Safety Requirements for Electronic Measuring Apparatus and has been supplied in a safe condition. The present instruction manual contains some information and warnings which must be followed by the user to ensure safe operation and to retain the apparatus in safe condition. The mains plug shall only be inserted in a socket outlet provided with protective earth contact. 2

WARNING When the apparatus is connected to its mains supply and the covers are opened, it is likely to expose live parts. The apparatus must be disconnected from all voltage sources before it is opened for any adjustment, replacement, maintenance or repair. Any adjustment, maintenance or repair of the opened apparatus under voltage shall be avoided as far as possible, and if inevitable, shall be carried out only by a skilled person who is aware of the hazard involved. Make sure that only fuses with the required current rating and of the specified type are used for replacement. The use of makeshift fuses, and the short circuiting of fuse holders is prohibited. Whenever it is likely that the protection has been impaired, the apparatus shall be made inoperative and be secured against any unintended operation and returned to our factory or agent for rectification. 3. CASE DESIGN The case is ruggedly constructed from an ABS/polycarbonate alloy. A strong internal sub frame ensures that the 5867 will withstand the harshest of environments. The front panel is a reverse printed polycarbonate overlay with clear and unambiguous text. 4. SPECIFICATION Digital display 8 digit, LED 0.8 height Range indicator, 999 count and status indicators via 3 LED s Working temperature 0 +40 C Relative Humidity max. 80% Normal temperature 20 C Oven temperature 40 C Storage temperature -20 C +50 C Mains connection 90-260V Size (mm) 24 x 28 x 12cm Weight 4.5 kg Measuring frequency 250ms 3

5. MAINTENANCE Normally no maintenance is required other than cleaning with a moist cloth. Avoid aggressive detergents or solvents. CAUTION: Before any maintenance, repair or exchange of parts or fuses, the instrument must be disconnected from the mains supply and all power sources. In the event of a fault occurring, the instrument should be returned to our factory or agent. A mains fuse is fitted to the mains inlet socket on the front panel, and should be replaced if necessary. CAUTION: Disconnect mains lead and all connecting leads, before removing fuse holder. Replace only with the correct fuse type, i.ee according to the following chart. Line Voltage Range VAC 47-63Hz Fuse (250V) IEC 127 Selection 5 x 20mm 100V 87-110V 1A (T) 120V 104-132V 220V 191-242V 1A (T) 240V 209-264V 6. BATTERY CHARGING The 5867 has built-in rechargeable sealed lead acid batteries which are fully charged when delivered. To indicate the state of charge, 8 LED s indicate the remaining battery capacity in % of full charge. The battery charger is built-in and the instrument may be connected to a voltage supply of between 90 to 260V AC. The instrument may be operated with a flat battery, provided that the unit is powered to the mains in this way the unit can be simultaneously operated and charged. If the unit is switched on and the battery is not sufficiently charged, the unit will turn itself off automatically. To conserve the battery, if no key is pressed during a 20 minute period the unit will also switch itself off. To protect the battery from complete discharge below a minimum capacity the unit will self power off. Charging is automatically controlled with built-in protection circuits eliminating the possibility of over charging. The unit will be fully recharged in 8 hours without being used at the same time. A fully charged unit should allow continuous operation for a working day, without the need to connect to the mains. BATTERIES The internal batteries are a sealed lead acid type. Care should be taken when disposing of them and they may be returned to Tinsley for safe disposal. 4

Any regulations and directions applying to the disposal of such material must be applied. Do not dispose of battery in fire Do not short circuit Do not crush, puncture, open, dismantle or otherwise mechanically interfere with the battery. NOTE: If storing for long periods, the batteries should be fully recharged every six months. 7. OPERATION When the 5867 is first switched on, the display will indicate the model number, followed by the version and then followed by the internal temperature of the unit. The display will then show which capacitance range and measuring range was last used and this will be shown on the display until it is next changed by the operator. The last used capacitance range will also be indicated by an illuminated LED on the relevant key. Note: This drawing represents issue 2. Issue 3 includes the following modifications: 1. ERROR LED is now OVEN LED. 2. TREND key is now USER key. Connect Q meter to a wound unit under test ( UUT ): The 2 leads supplied are colour coded plug the relevant lead into the relevant input on the instrument (P1, P2). Note: These are colour coded for simplicity but it does not matter to the reading if they are interchanged. Connect the other ends of the 2 leads onto UUT. Turn on Q meter: By pressing the On/Off button. 5

Capacitance Sensitivity: Select the required range by pressing one of the keys marked A to E. The selected range is indicated by an LED. In the case of ranges A and B, this is located on one key which may be toggled. Press it once for range A and twice for B. The range should be selected to match the UUT type being used. As an indication, a more sensitive reading required means that a smaller capacitance value should be selected see list below for capacitances. A: 100μF B: 10μF C: 1μF D: 100nF E: 10nF Note: When the unit is switched on, the last capacitance setting is remembered. Range Selection: Dependant on the inductance of the UUT, there are 15 ranges of which 1 is the most sensitive and 15 is the least sensitive. There are two ways in which the range can be adjusted: Manually: using the up and down arrow keys Automatically: pressing the Auto key. This will automatically choose the most appropriate range As a guide, if there is too much signal, 999 will be displayed (i.e. over range) and the O/C leads LED will be illuminated, indicating that a higher range should be selected, which can be achieved by pressing the up arrow key. A suitable range, as would be chosen by the Auto range method described above, would be to pick a range that displays a value of between 500 and 999 (over range). When a reading of less than 500 is displayed, there may not be enough signal. In this case a lower range should be selected, which can be achieved by pressing the down arrow key. The choice of the correct combination of Capacitance Sensitivity and Range Selection, is best found by experience in the testing of similar UUT s. It is then possible to use the instrument as a comparator if there are many UUT s at the time of test that are identical, OR as a pass/fail against a known standard, if there if only one UUT that is identical to the standard. Hold key: Select this to hold the current displayed value. Ave. key: Select this to put the unit into Average Mode. The key should be pressed and held whilst it scrolls through the number of reads over which to average i.e. 2, 4, 8, 16 or off. For example, if 2 is chosen, then the mean result of 2 reads will be taken and then displayed. This can be used to filter noisy readings and to provide a stable, accurate result. Cal. key: This can be pressed at any time and it isolates the output while it undertakes a quick internal calibration. 6

User key: This allows the oven facility to be turned on and off. The oven maintains the instrument s precision components at a stable and uniform 40 C. When the button is pressed, the OVEN LED will light to indicate that the oven has been turned on. When it has reached within 5 C of the 40 C the LED will flash. When it is within it s 40 C band the LED switches off. If the oven is turned on when the user button is pressed, the temperature will be displayed. The button may be pressed again to turn off the oven. Note: The Shift key is reserved for future use. Status LED s: These LED s will light to indicate the instrument status: OVEN: This illuminates when the oven is heating (see section above, titled Oven. This will flash when the oven is within 5 C of the standard 40 C. REMOTE: This illuminates when the Q meter is being controlled remotely and is lit whilst commands are being transferred via an RS232 link. O/C LEAD: One of the measuring leads is open circuit or is not connected to the transformer correctly, or the selected range is too small. FAST CHARGE: When the unit is being charged from the mains (and whilst the battery is still partially discharged) this LED will illuminate. It will go off when the battery is approaching its fully charged state. Switch key: In normal operation, the key position should be set to RUN. For an engineer to programme values in, the key should be switched to the ENG position. 8. REMOTE OUTPUT The RS232 plug should be connected here (via an RS232/DIN connector adaptor). The digital output is a 38400baud* N 8 1 serial interface. The RX & TX conform to the EIA RS232 standard of +15 to +5v (Logic Low) and 15 to 5v (Logic High). * Can be set in the menu for the instrument. 7

REMOTE DIN (Front panel view) RS232 commands Function Remarks? 63dec Help menu Send this list K 75dec Get for model version & board issues S 83dec Get internal status Send 6 bytes D 68dec Get current instrument display value Range+Gain+reading (6 bytes) R 82dec Read next value or force read Range+Gain+reading (6 bytes) Gxn 71dec Set Range & Gain where x=a/b/c/d/e & n=0 to 15. Responds with xn T 84dec Get Internal Temperature TempCo = xc C 67dec Do Calibration cycle A 65dec Get Internal Voltages I 73dec Get Unit Itent string Tinsley,5867,xVx L{OPT} Start logging readings QPT Output Format Q,xxx,P,xxx,T,xxx where Q=value, P = Reading interval, T = temp value is present (xxx) if QPT are specified. P{x,y} Set pulse duration charge, read ** Engineering mode only E{x} Eeprom diagnostics where x is ** Engineering mode only P dump to serial channel D Reset to default C = Clear W{x} Run diagnostics function ** Engineering mode only F Flash all LEDS P Set processor port to x 1 Strobe on 0 Strobe off Q Power off Rnx relay n on(1) off(0) i.e. R20 Relay 2 off. Ax Get ADC channel x value 8

CONTACT US 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: info@tinsley.co.uk CONTACT US Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: info@tinsley.co.uk All information provided by Tinsley in this datasheet is believed to be accurate. Tinsley reserves the right to discontinue and change specifications and prices at any time without prior notice. For further details, please refer to our website 9