LP 10. GENERATOR SPECIFICATION Power Rating (KVA) 10. Electric Power (KWe) 8. Rated Current (A) 14. No of Phases/Volts* 3/415

Similar documents
Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PGDLS / / / / / / / / /

SIVASA Doosan Series. SD250 Technical Data

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

PPU Diesel Power 50/60Hz Containerized Generator Set

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

WPS20/S EP Series. Features:

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGKT / / / / / / / / / / / /

Diesel Generator Set S3.8 Series Engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

WPS60/S EP Series. Features:

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

WPS150/S EP Series. Features:

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

LWALR LIQUID COOLED LONG RUNNING GENSETS

WPS100/S EP Series. Features:

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

WPS350/S EP Series. Features:

Model MP150 W W

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Rating Definitions and Conditions

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Rating Definitions and Conditions

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

1 / Genset general description

Better Soundproof, Better Life!

1 / Genset general description

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

Part III : Technical Specification POS B)

GMS200C/S EC Series. Features:

Rating Definitions and Conditions

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS250/S EP Series. Features:

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Model NA 2 L

DIESEL GENERATOR SET MTU 4R0113 DS80

GMS100C/S EC Series. Features:

Super Silent, Superior Life!

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Rating Definitions and Conditions

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

1 / Genset general description

Part III : Technical Specification POS C)

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

8,000 Watt Diesel Generator

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GMS350C/S EC Series. Features:

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Standby Amper VOLTAGE

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Komatsu Power Generation Systems

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

Rating Definitions and Conditions

DIESEL GENERATOR SET MTU 12V1600 DS660

Standby Amper VOLTAGE

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

GMR - 67P 67P 09/05/2016 GMR - 067P

Diesel generator set QSL9 series engine

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GE.PK.022/020.SS+0_all

BHARAT HEAVY ELECTRICAL LIMITED Boiler auxiliaries Plant Ranipet Vellore ,TamilNadu, India

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

CUKUROVA GENERATOR SYSTEMS

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

Transcription:

LP 10 GENERATOR SPECIFICATION Power Rating (KVA) 10 Electric Power (KWe) 8 Rated Current (A) 14 No of Phases/Volts* 3/415 Dimensions (L X W X H, mm x mm x mm) 1760 x 900 x 1400 Fuel Tank Capacity (Litres) 250 Battery Capacity (AH) 99 System Voltage (VDC) 12 Weight (Kg) 750 Dry Weight (Engine-Kg) 220 ENGINE SPECIFICATION Engine Model AL485G1 Engine Max HP 24.8 Engine Rated HP 23.5 Aspiration Natural No of Cylinders 4 Bore & Stroke (mm x mm) 85*92 Displacement (Litres) 2.088 Compression Ratio 18:1 Fuels cons (Litre/hr)** 2.0 Lub oil Sumb Capacity (Litres) 8.5 Lub oil Consumption <0.15% Coolant Capacity (Litres) 6.0 Governing Class * Single Phase DG set is available optional from 10 KVA ** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP condition, Tolerance will be +5% A1

ALTERNATOR SPECIFICATION Model Type Exciter type Voltage regulator Insulation PI 044E 4 pole Brushless AVR-AS480 Class H Temperature rise (ºC) 125 Bearing ±Single Voltage regulation ±0.5% Rated Voltage (V) 415 SPECIFICATION FOR STANDARD MANUAL PANEL 3pole MCB / MCCB Lube Oil Pressure Analogue Gauge Battery Charging Ammeter Running-Hour Counter Digital Multifunction meter Fault Indication (LED Type on Engine safety Unit) Voltage/Ampere/Frequency Low Oil pressure Battery Charger Failure High Engine Temperature Low fuel level Current Transformers of suitable rating Indications (LED): DG ON

Control Key switch for Start/Stop SPECIFICATION FOR STANDARD AMF PANEL 4 Pole Contactor for DG 4 Pole Contactor for MAINS MCB / MCCB for short circuit protection Monitoring of engine protection Alphanumeric LCD Display Supervision of Mains and DG voltage Mains and DG contactor interlock Features Provision for Remote start / stop Parameter setting by front panel key board Auto / Manual mode operation Programmable parameters / timers Voltage Multifunction meter Ampere Frequency Oil pressure Analogue meter Mains On Indication Lamps DG On Load on Mains

SMPS based battery charger with float boost charging. Manual mode controls DG start DG stop Load transfer POWER RATING Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528 Reference condition (Dec C Ambient Temp) 27 Atmospheric Condition (KPA-750mm of Hg) 100 Humidity 60% - As per IS10002, ISO 3046 LP 15 GENERATOR SPECIFICATION Power Rating (KVA) 15 Electric Power (KWe) 12 Rated Current (A) 21 No of Phases/Volts* 3/415 Dimensions (L X W X H, mm x mm x mm) 1760 x 900 x 1400 Fuel Tank Capacity (Litres) 250 Battery Capacity (AH) 99 System Voltage (VDC) 12 Weight (Kg) 810 Dry Weight (Engine-Kg) 220 ENGINE SPECIFICATION Engine Model AL485G1 Engine Max HP 24.8 Engine Rated HP 23.5 Aspiration Natural

No of Cylinders 4 LP 15Bore & Stroke (mm x mm) 85*92 Displacement (Litres) 2.088 Compression Ratio 18:1 Fuels cons (Litre/hr)** 2.5 LP 15Lub oil Sumb Capacity (Litres) 8.5 Lub oil Consumption <0.15% Coolant Capacity (Litres) 6.0 Governing Class * Single Phase DG set is available optional from 10 KVA ** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP condition, Tolerance will be +5% A1 ALTERNATOR SPECIFICATION Model Type Exciter typelp 15 Voltage regulator Insulation PI 044G 4 pole Brushless AVR-AS480 Class H Temperature rise (ºC) 125 Bearing ±Single Voltage regulation ±0.5% Rated Voltage (V) 415 SPECIFICATION FOR STANDARD MANUAL PANEL 3pole MCB / MCCB Analogue Gauge Lube Oil Pressure

Battery Charging Ammeter Running-Hour Counter Digital Multifunction meter Fault Indication (LED Type on Engine safety Unit) Voltage/Ampere/Frequency Low Oil pressure Battery Charger Failure High Engine Temperature Low fuel level Current Transformers of suitable rating Indications (LED): Control DG ON Key switch for Start/Stop SPECIFICATION FOR STANDARD AMF PANEL 4 Pole Contactor for DG 4 Pole Contactor for MAINS MCB / MCCB for short circuit protection Monitoring of engine protection Alphanumeric LCD Display Supervision of Mains and DG voltage Mains and DG contactor interlock Features Provision for Remote start / stop Parameter setting by front panel key board Auto / Manual mode operation Programmable parameters / timers

Voltage Multifunction meter Ampere Frequency Oil pressure Analogue meter Mains On Indication Lamps DG On Load on Mains SMPS based battery charger with float boost charging. Manual mode controls DG start DG stop Load transfer POWER RATING Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528 Reference condition (Dec C Ambient Temp) 27 Atmospheric Condition (KPA-750mm of Hg) 100 Humidity 60% - As per IS10002, ISO 3046 LP 20 GENERATOR SPECIFICATION Power Rating (KVA) 20 Electric Power (KWe) 16 Rated Current (A) 28 No of Phases/Volts* 3/415

Dimensions (L X W X H, mm x mm x mm) 2100 x 950 x 1400 Fuel Tank Capacity (Litres) 250 Battery Capacity (AH) 99 System Voltage (VDC) 12 Weight (Kg) 900 Dry Weight (Engine-Kg) 220 ENGINE SPECIFICATION Engine Model AL485TG2 Engine Max HP 31.5 Engine Rated HP 29.5 Aspiration Natural No of Cylinders 4 Bore & Stroke (mm x mm) 85*92 Displacement (Litres) 2.088 Compression Ratio 18:1 Fuels cons (Litre/hr)** 3.4 Lub oil Sumb Capacity (Litres) 8.5 Lub oil Consumption <0.3% Coolant Capacity (Litres) 6.0 Governing Class * Single Phase DG set is available optional from 10 KVA ** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP condition, Tolerance will be +5% A1 ALTERNATOR SPECIFICATION Model Type Exciter type Voltage regulator PI144D1 4 pole Brushless AVR-AS480

Insulation Class H Temperature rise (ºC) 125 Bearing ±Single Voltage regulation ±0.5% Rated Voltage (V) 415 SPECIFICATION FOR STANDARD MANUAL PANEL 3pole MCB / MCCB Lube Oil Pressure Analogue Gauge Battery Charging Ammeter Running-Hour Counter Digital Multifunction meter Fault Indication (LED Type on Engine safety Unit) Voltage/Ampere/Frequency Low Oil pressure Battery Charger Failure High Engine Temperature Low fuel level Current Transformers of suitable rating Indications (LED): Control DG ON Key switch for Start/Stop SPECIFICATION FOR STANDARD AMF PANEL 4 Pole Contactor for DG 4 Pole Contactor for MAINS

MCB / MCCB for short circuit protection Monitoring of engine protection Alphanumeric LCD Display Supervision of Mains and DG voltage Mains and DG contactor interlock Features Provision for Remote start / stop Parameter setting by front panel key board Auto / Manual mode operation Programmable parameters / timers Voltage Multifunction meter Ampere Frequency Oil pressure Analogue meter Mains On Indication Lamps DG On Load on Mains SMPS based battery charger with float boost charging. Manual mode controls DG start DG stop Load transfer POWER RATING

Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528 Reference condition (Dec C Ambient Temp) 27 Atmospheric Condition (KPA -750mm of Hg) 100 Humidity 60% - As per IS10002, ISO 3046 LP 25 GENERATOR SPECIFICATION Power Rating (KVA) 25 Electric Power (KWe) 20 Rated Current (A) 35 No of Phases/Volts* 3/415 Dimensions (L X W X H, mm x mm x mm) 2100 x 950 x 1400 Fuel Tank Capacity (Litres) 250 Battery Capacity (AH) 99 System Voltage (VDC) 12 Weight (Kg) 955 Dry Weight (Engine-Kg) 220 ENGINE SPECIFICATION Engine Model AL485TAG3 Engine Max HP 36.9 Engine Rated HP 34.9 Aspiration Natural No of Cylinders 4 Bore & Stroke (mm x mm) 85*92 Displacement (Litres) 2.088 Compression Ratio 18:1 Fuels cons (Litre/hr)** 3.9 Lub oil Sumb Capacity (Litres) 8.5

Lub oil Consumption <0.3% Coolant Capacity (Litres) 9.0 Governing Class * Single Phase DG set is available optional from 10 KVA ** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP condition, Tolerance will be +5% A1 ALTERNATOR SPECIFICATION Model Type Exciter type Voltage regulator Insulation PI144E1 4 pole Brushless AVR-AS480 Class H Temperature rise (ºC) 125 Bearing ±Single Voltage regulation ±0.5% Rated Voltage (V) 415 SPECIFICATION FOR STANDARD MANUAL PANEL 3pole MCB / MCCB Lube Oil Pressure Analogue Gauge Battery Charging Ammeter Running-Hour Counter Digital Multifunction meter Voltage/Ampere/Frequency Fault Indication (LED Type on Engine safety Unit) Low Oil pressure Battery Charger Failure

High Engine Temperature Low fuel level Current Transformers of suitable rating Indications (LED): Control DG ON Key switch for Start/Stop SPECIFICATION FOR STANDARD AMF PANEL 4 Pole Contactor for DG 4 Pole Contactor for MAINS MCB / MCCB for short circuit protection Monitoring of engine protection Alphanumeric LCD Display Supervision of Mains and DG voltage Mains and DG contactor interlock Features Provision for Remote start / stop Parameter setting by front panel key board Auto / Manual mode operation Programmable parameters / timers Voltage Multifunction meter Ampere Frequency Analogue meter Oil pressure

Mains On Indication Lamps DG On Load on Mains SMPS based battery charger with float boost charging. Manual mode controls DG start DG stop Load transfer POWER RATING Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528 Reference condition (Dec C Ambient Temp) 27 Atmospheric Condition (KPA -750mm of Hg) 100 Humidity 60% - As per IS10002, ISO 3046 LP 30 GENERATOR SPECIFICATION Power Rating (KVA) 30 Electric Power (KWe) 24 Rated Current (A) 42 No of Phases/Volts* 3/415 Dimensions (L X W X H, mm x mm x mm) 2150 x 1050 x 1670 Fuel Tank Capacity (Litres) 250 Battery Capacity (AH) 99 System Voltage (VDC) 12 Weight (Kg) 1050 Dry Weight (Engine-Kg) 370

ENGINE SPECIFICATION Engine Model AL4102G1 Engine Max HP 48.3 Engine Rated HP 44.6 Aspiration Natural No of Cylinders 4 Bore & Stroke (mm x mm) 102*118 Displacement (Litres) 3.857 Compression Ratio 17.5:1 Fuels cons (Litre/hr)** 4.5 Lub oil Sumb Capacity (Litres) 8.5 Lub oil Consumption <0.15% Coolant Capacity (Litres) 11.0 Governing Class * Single Phase DG set is available optional from 10 KVA ** Fuel Consumption of Genset @75% of load is considering specific gravity of fuel 0.8355 at NTP condition, Tolerance will be +5% A1 ALTERNATOR SPECIFICATION Model Type Exciter type Voltage regulator Insulation PI144G1 4 pole Brushless AVR-AS480 Class H Temperature rise (ºC) 125 Bearing ±Single Voltage regulation ±0.5% Rated Voltage (V) 415 SPECIFICATION FOR STANDARD MANUAL PANEL

3pole MCB / MCCB Lube Oil Pressure Analogue Gauge Battery Charging Ammeter Running-Hour Counter Digital Multifunction meter Fault Indication (LED Type on Engine safety Unit) Voltage/Ampere/Frequency Low Oil pressure Battery Charger Failure High Engine Temperature Low fuel level Current Transformers of suitable rating Indications (LED): Control DG ON Key switch for Start/Stop SPECIFICATION FOR STANDARD AMF PANEL 4 Pole Contactor for DG 4 Pole Contactor for MAINS MCB / MCCB for short circuit protection Features Monitoring of engine protection Alphanumeric LCD Display Supervision of Mains and DG voltage Mains and DG contactor interlock

Provision for Remote start / stop Parameter setting by front panel key board Auto / Manual mode operation Programmable parameters / timers Voltage Multifunction meter Ampere Frequency Oil pressure Analogue meter Mains On Indication Lamps DG On Load on Mains SMPS based battery charger with float boost charging. Manual mode controls DG start DG stop Load transfer POWER RATING Power rating as per Standard reference condition as per BS 5514/ISO 3046/ISO 8528 Reference condition (Dec C Ambient Temp) 27 Atmospheric Condition (KPA -750mm of Hg) 100 Humidity 60% - As per IS10002, ISO 3046