MCCB Accessories to suit AF

Similar documents
Technical Data Accessories MCBs Ex9B.

DPX moulded case circuit breakers

Circuit Breakers Ex9M

cor Long Run Experience

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Power protection solutions

max pole for t=15 ms

MINIATURE CIRCUIT BREAKER

DMX 3 -I 2500 switch disconnectors

Molded Case Circuit Breaker

Vistop TM isolating switches 63 to 160A

CirCuit Breakers and isolators Catalogue of installation and moulded Case devices

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Low voltage moulded case circuit breaker EB2

Miniature Circuit Breaker

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

WORKSHOP SPECIFICATIONS

DPX 1600 Electronic release

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Low voltage circuit breakers

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

3VT Kompaktleistungsschalter bis 630A

Low voltage circuit breakers

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Cat N 3. OVERALL DIMENSIONS

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

01 Spectra Plus - Introduction

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

Wall mounted switchgear

Manual Motor Starters. Meta-MEC

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

New DX 3 High rating & breaking capacity

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

DRX 125 Circuit breaker (not adjustable)

COMPLETE SOLUTIONS FOR POWER PROTECTION

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Series L9 UL489 Miniature Circuit Breakers

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

MOULDED CASE CIRCUIT BREAKERS BC160N

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

DRX 250 B/N/H Circuit breaker (not adjustable)

Thermal Overcurrent Circuit Breaker 3120-F...

LV & MV Circuit Breakers, Contactors & Overload Relays

DPX Thermal magnetic and trip-free switches DPX 3 -I 630


Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Short form catalogue. Motor protection & control

Motor Protection Circuit Breakers

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors Technical data

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DRX 100 B/N/H Circuit breaker (not adjustable)

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

18-I73E CAT REF.

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

DPX earth leakage DPX 3 -I earth leakage

Industrial Contactors CTX 3 3P 185A - 800A

PIX-H Metal-clad switchgear up to 17.5kV

Memshield - ACB Ratings & Specifications

An innovative technology

Thermal Overcurrent Circuit Breaker 3120-F...

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

SD Series Non-Fused Load Switches

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

The effective choice The benefits of a product with the highest quality standards

Low voltage moulded case circuit breaker EB2

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

ADVANCE GRP Series 125A Switched Interlocked socket outlets

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Signal lamps RS, RSB A20. Technical data RS, RSB. Dimensional drawing of RS, RSB. Number of poles Rated voltage Un

What you need to know. Â Conformity to standards

DPX Magnetic only

Magnetic Overcurrent Circuit Breaker

Residual current circuit breakers with conditional shortcircuit

DX³ RCCBs - ID 4P up to 100 A

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Thermal Overcurrent Circuit Breaker 3120-F...

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

DPX Electronic + earth leakage

3VU13, 3VU16 Circuit-Breakers

DPX 630 Electronic release

Transcription:

MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal accessories location and combinations of types Accessory locations Auxiliaries and s mount within the LEFT side of an MCCB. Shunt s and Under Voltage s mount within the RIGHT side of an MCCB. Permissible combinations Auxiliary contact blocks: Depending on the auxiliary type and MCCB size, 1, 2 or 3 auxiliary switches can be fitted. contact blocks: a maximum of 1 can be installed in an MCCB. One Shunt or One Under-Voltage can be installed. Both cannot be mounted in an MCCB together, as they occupy the same position For more specific information on internal accessory combinations and maximum allowable, refer to the table below. MCCB type MCCB left side MCCB right side (AF = Amp Frame) General purpose type Heavy duty type Auxiliary Auxiliary Under Voltage or Shunt 125 AF 3-4 Pole 2 1 160 / 250 AF 2 1 2 1 Either one shunt or one UVT 400 / 630 AF 3 2 Example: The table above shows that the maximum number of internal accessories that can fit into a 125AF MCCB is: 2 auxiliaries, 1 alarm (general purpose types), and either a shunt or UVT. Types of switching circuits: MCCB Left MCCB Right Heavy duty type General purpose type device NO NC 1 C/O 1 C/O Shunt UVT (NO/NC) (NO/NC) General purpose contact blocks have changeover contacts switching from NO to NC with a common terminal. Heavy duty types have electrically isolated 1Normally open (N/O) or 1 Normally closed (1N/C) contacts. Price Schedule T2 41

MCCB s Accessories to suit 125-630AF MCCBs Internal accessories Shunt s SH Under Voltage s UV N Auxiliary & switches Cat. No. Internal accessories are common for MCCBs 125A to 630A. All have screw terminals unless those indicated below with wire leads as standard For 1 pole S160NF MCCBs 110 V AC T2SH16A10WA 230 240 V AC T2SH16A20WA 24 V DC T2SH16D02WA 110 V DC T2SH16D10WA 230 V DC T2SH16D20WA For 2, 3 and 4 pole MCCBs 110 V AC T2SH00A10TA 230 240 V AC T2SH00A20TA 400 415 V AC T2SH00A40TA 24 V DC T2SH00D02TA 48 V DC T2SH00D04TA 110 V DC T2SH00D10TA 230 V DC T2SH00D20TA Instantaneous operation 110 V AC T2UV00A10NTA 200 240 V AC T2UV00A20NTA 380 450 V AC T2UV00A40NTA 24 V DC T2UV00D02NTA 110 V DC T2UV00D10NTA 230 V DC T2UV00D20NTA Time delayed operation (500mS) 110 V AC T2UV00A10DTA 200 240 V AC T2UV00A20DTA 380 450 V AC T2UV00A40DTA 24 V DC T2UV00D02DTA 110 V DC T2UV00D10DTA 230 V DC T2UV00D20DTA General type (2A @ 240V Inductive) 1 C/O Auxiliary T2AX00M3STA 1 C/O Auxiliary - with 0.7m wire leads T2AX00M3SWA 1 C/O T2AL00M3STA 1 C/O - with 0.7m wire leads T2AL00M3SWA General use auxiliary & alarm Heavy duty type (4A @ 240V Inductive) 1 NO Auxiliary T2AX00B1STA 1 NC Auxiliary T2AX00B2STA 1 NO T2AL00B1STA 1 NC T2AL00B2STA Heavy duty auxiliary & alarm Micro switching type (very low voltages and currents) 1 C/O Auxiliary T2AX00M3RTA 1 C/O T2AL00M3RTA Price Schedule T2 42

MOUNTED Electrical control accessories for TemBreak 2 are designed with the installer in mind. Status and alarm contacts, remote tripping coils and undervoltage protection coils are of modular design and convenient to use. (1) (2) (3) (4) (5) (6) 1) Heavy-duty auxiliary switch 2) Heavy-duty alarm switch 3) General-purpose auxiliary switch 4) General-purpose alarm switch 5) Shunt trip 6) Undervoltage trip Every accessory fits every MCCB and -Disconnector in the range. All accessories are endurance tested to the same level as MCCBs. TemBreak 2 internal accessories are easily field-installable. All accessories are individually packaged and are supplied with fitting instructions. Control wiring is terminated on the accessory screw terminal. Alternatively a terminal block which clips to the side of the MCCB is available. Installing Accessories in a 4 pole S400 model The internal accessories can be easily installed in the field without special tools or product training. 1 2 3 4 5 6 7 8 Easy field-installation of Accessories Internal accessory can be simply plugged into position No tools are required for this, except a screwdriver to lift the MCCB front cover clips. Accessories fit with a firm click when installed correctly. Colour coding of accessories helps identification and installation Click page 54 Beyond the Standard

MOUNTED Valid Maximum Accessory Combinations Frame size (A): 125 160 and 250 400 and 630 General Purpose Shunt General Purpose Shunt General Purpose Shunt Heavy Duty Undervoltage Heavy Duty Undervoltage Heavy Duty Undervoltage Status indication switches mount in the left side of the MCCB. General purpose and heavy duty status indication switches cannot be mixed in the same MCCB. Only one alarm switch can be fitted to an MCCB. Shunt trips and undervoltage trips mount in the right side of the MCCB. It is not possible to install a shunt trip and an undervoltage trip in an MCCB as they occupy the same location. Undervoltage trips can provide remote tripping if necessary by wiring a normally closed contact or pushbutton in series with the protected supply. Undervoltage trips with time delays require an external time delay controller which clips to the side of the MCCB. Beyond the Standard page 55

MOUNTED Status Indication es.2.2.1.1.4.4 OFF, Terminal Designations and Function of Terminal Designations and Function of (AX) An auxiliary switch electrically indicates the ON or OFF status of the MCCB. The general purpose type is a changeover switch with 3 terminals. A microcurrent version is available for switching currents as low as 1mA. Auxiliary switches are colour coded grey. The cable capacity of the terminals is 0.5 to 1.25mm 2. The general purpose auxiliary switch meets the requirements of IEC 61058-1. (AL) An alarm switch electrically indicates the TRIP status of the MCCB. The general purpose type is a changeover switch with 3 terminals. A microcurrent version is available for switching currents as low as 1mA. switches are colour coded grey and black. The cable capacity of the terminals is 0.5 to 1.25mm 2. The general purpose alarm switch meets the requirements of IEC 61058-1. General purpose auxiliaries and alarm switch ratings Microcurrent versions Volts (V) AC Inductive Volts (V) DC Inductive Minimum Volts (V) DC Minimum 440 - - 250 - - 100mA at 240 3 2 125 0.4 0.05 15V DC. 110 3 2 30 3 2 1mA at 5V 30 0.1 DC and 30V DC. page 56 Beyond the Standard

MOUNTED Status Indication es.3.4.2 Terminal Designations and Function of, N/O contact.1 Terminal Designations and Function of, N/C contact.3 Terminal Designations and Function of,.4 N/O contact.1 Terminal Designations and Function of,.2 N/C contact Ratings of Auxiliary and es Volts (V) AC Inductive OFF, OFF, Volts (V) DC Inductive 500 1 1-440 3 3 250 0.5 0.5 240 4 4 125 1 1 110 5 5 48 3 2.5 48 6 6 24 6 2.5 (AX) The heavy duty auxiliary switch has an impulse withstand voltage (Uimp) of 6kV and is suitable for isolating safety circuits. The auxiliary switch electrically indicates the ON or OFF status of the MCCB. The heavy duty type is a bridge switch with two terminals. It is available in either normally open or normally closed configurations. Heavy duty auxiliary switches are colour coded grey. The cable capacity of the terminals is 1.25 to 2.5mm 2. The heavy duty auxiliary switch meets the requirements of IEC 60947-5-1. It has direct opening action, recommended by IEC 60204-1 Safety of Machinery - Electrical Equipment for Machines. (AL) The heavy duty alarm switch has an impulse withstand voltage (Uimp) of 6kV and is suitable for isolating control circuits. The alarm switch electrically indicates the TRIP status of the MCCB. The heavy duty type is a bridge switch with two terminals. It is available in either normally open or normally closed configurations. Heavy duty auxiliary switches are colour coded grey and black. The cable capacity of the terminals is 1.25 to 2.5mm 2. The heavy duty alarm switch meets the requirements of IEC 60947-5-1. It has direct opening action, recommended by IEC 60204-1 Safety of Machinery - Electrical Equipment for Machines. Beyond the Standard page 57

MOUNTED Remote ping Devices Shunt (SHT) A shunt trip allows an MCCB to be tripped remotely on the application of the rated coil voltage across the shunt trip terminals. TemBreak 2 shunt trips have continuously rated coils and are suitable for use in electrical interlocking applications. The MCCB contacts and toggle will move to the tripped position when the shunt trip is operated. The permissible voltage range is 85% to 110% for AC or 75% to 125% for DC. The cable capacity of the terminals is 0.5 to 1.25mm 2. Shunt trips are colour coded grey. Controller C1 C2 ~ ( ) ~ (+) Shunt s Terminal Designations of Shunt s Ratings of Shunt s Rated Voltage Excitation Current (A) Voltage AC Voltage DC 100-120 200-240 380-450 24 48 100-120 200-240 0.014 0.014 0.0065 0.03 0.03 0.011 0.011 Under Voltage (UVT) An undervoltage trip will trip the breaker automatically when the voltage applied to the terminals of the undervoltage coil drops to between 70% and 35% of its voltage rating. The undervoltage trip prevents the circuit breaker being closed unless a voltage corresponding to at least 85% of its voltage rating is applied across the terminals of the undervoltage coil. The MCCB contacts and toggle will move to the tripped position when the under-voltage trip operates. Undervoltage trips with AC operating voltages are available with 500ms time delays. Time-delay units are fitted to the outside of MCCBs. The cable capacity of the terminals is 0.5 to 1.25mm 2. Undervoltage trips are colour coded grey and black. Controller D1 D2 ~ ( ) ~ (+) Undervoltage s Terminal Designations of Undervoltage s Ratings of Undervoltage s Power supply capacity (VA) Excitation current (ma) Rated Voltage AC Voltage DC Voltage 100-120 200-240 380-450 24 100-120 200-240 Power Supply Capacity (VA) 1.4 1.4 2.28 23 10 10 page 58 Beyond the Standard

TERMINATION OF CONTROL WIRING Terminal blocks are for optional use with all types of internally mounted accessory. Terminal Block for Plug-in MCCBs The terminal block for a plug-in MCCB consists of: a male section pre-fitted with 3 cables with which clips easily to the back of the MCCB a female section with 3 user terminals which clips easily into the plug-in base. Up to 4 terminal blocks can be installed on a 125A, 160A or 250A frame MCCB. Up to 5 terminal blocks can be installed on a 400A or 630A frame MCCB. Terminal Block for Front-Connected and Rear-Connected MCCBs (TF) A terminal block facilitates convenient and accessible control wiring to internally mounted accessories. It allows the use of control wiring cables with larger cross-sectional area than permitted by the internal accessories themselves. This terminal block can be clipped to either side of the MCCB. If mounted on the left incoming wiring will be fed vertically up to the terminals. If mounted on the right, the incoming wiring will be fed vertically down to the terminals. Terminal blocks are pre-fitted with outgoing wiring which can be terminated directly on each internal accessory. The maximum incoming cable size to the terminal block is 2.0mm 2. Terminal blocks have 11 terminals. Terminal Block for Plug-in MCCBs Terminal Block for Front-Connected and Rear-Connected MCCBs Beyond the Standard page 59