Tactile Switch (Hinged Type)

Similar documents
Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Mechanical Key Switch

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Subminiature Basic Switch

B3F. Miniature, Space-saving Switch

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Ordering Information. Text Surface-Mounting Signal Relay G6K

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Model Number Structure

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Lighted PushButton Switch

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Number Structure

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Safety-door Switch. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5LE

Inductive Proximity Sensor

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Low-torque Basic Switch

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

MEMS Gauge Pressure Sensor

Model Number Structure

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Model Number Structure

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Lighted Pushbutton Switch

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Model Number Structure

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

Technical Information Solid State Relays. Glossary. Solid State Relays

Subminiature Basic Switch

Switching Power Supply

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Manual Reset Limit Switch

Small Limit Switch D4V

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Pressure sensor with built-in amplification and temperature compensation circuit

Safety Limit Switch

Hinged Safety Door Switch

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Switching Power Supply

TURQUOISE STROKE SWITCHES

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Turquoise Stroke Switches

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Model Number Structure

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

TURQUOISE STROKE SWITCHES

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Power Controller. (see note 1) 10 sec

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

Transcription:

Tactile Switch (Hinged Type) Hinged Design Developed through Ergonomics Quick, superior snap action through hook-type hinge construction. Available with 1 or LEDs or without LEDs. The hinge button is available in a wide variety of colors (five standard colors). Ordering Information Color of No LED One LED Two LEDs (left and right) hinged button Red Yellow Green Red/Yellow Red/Green Yellow/Green Light gray -1000-000 -3000-4000 -5000-000 -7000 Black -1100-100 -3100-4100 -5100-100 -7100 Orange -100-00 -300-400 -500-00 -700 Yellow -1300-300 -3300-4300 -5300-300 -7300 Blue -1400-400 -3400-4400 -5400-400 -7400 Specifications Ratings/Characteristics Switching capacity 1 to 50 ma, 5 to 4 VDC (resistive load) Ambient temperature 5 C to 70 C (with no icing) Ambient humidity 35% to 85% Contact configuration SPST-NO Contact resistance 100 m max. (rated: 1 ma, 5 VDC) Insulation resistance 100 M min. (at 50 VDC) Dielectric strength 500 VAC, 50/0 Hz for 1 min Bounce time 5 ms max. Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction: 1,000 m/s {approx. 100G} max. Malfunction: 100 m/s {approx. 10G} max. Life expectancy 3,000,000 operations min. Weight Approx. 1.5 to 1.7 g 33

Operating Characteristics Operating force (OF) Releasing force (RF) Pretravel (PT) 1.7 0.49 N {130 50 gf} 0.9 N {30 gf} min. 0.3 +0. / 0.1 mm Built-in LED Performance Item Red Yellow Green Forward voltage VF Standard value (V).0.0.1 Forward current IF Standard value (ma) 0 0 0 Permissible loss P Absolute maximum value (mw) 84 84 84 Reverse voltage VR Absolute maximum value (V) 5 5 5 Note: Since the built-in LED does not contain any limiting resistors, externally connect limiting resistors within the limits shown in the above table. Engineering Data Operating Force vs. Stroke (Typical) Operation force (N {gf}) 1.7 {180} 1. {170} 1.5 {10} 1.37 {140} 1.17 {10} 0.98 {100} 0.78 {80} 0.58 {0} 0.39 {40} 0.19 {0} Stroke S (mm) 34

Dimensions Note: All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Types with no LED -1@00 PCB Mounting (Top View) Two, 1.8±0.05 dia.* (For positioning boss) Panel Cutout Terminal Arrangement /Internal Connections (Top View) 18±0. 1 5±0.1 1.5±0.1 19.±0. 1±0. Four, 1.±0.05 dia. 13.±0..8 10.3±0. 9±0. 1 LED Types -@00, -3@00, -4@00 18±0. 1 13.8±0.5 PCB Mounting (Top View).5 Two, 1.8±0.05 dia.* (For positioning boss) Panel Cutout Terminal Arrangement /Internal Connections (Top View) 1.5±0.1 1±0. 5±0.1 Six, 1.±0.05.8 19.±0. 13.±0. 10.3±0. 9±0. 13.8±0.5 LED Types -5@00, -@00, -7@00 18±0. 1 PCB Mounting (Top View) 3. Panel Cutout.5.5 Two, 1.8±0.05 dia.* (For positioning boss) 1.5+0.1 Terminal Arrangement /Internal Connections (Top View) 19.±0. 1±0. 5±0.1 Eight, 1.±0.05 dia. 13.±0..8 10.3±0. 9±0. 13.8±0.5 Be sure to read the precautions common to all Tactile Switches on pages 5 to 7 for correct use. 35

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.0357. Cat. No. A071-E1-04 3

Safety for Safe Use Use the Switch within the rated voltage and current ranges, otherwise the Switch may have a shortened life expectancy, radiate heat, or burn out. This particularly applies to the instantaneous voltages and currents when switching. for Correct Use Storage To prevent degradation, such as discoloration, in the terminals during storage, do not store the Switch in locations that are subject to the following conditions. 1. High temperature or humidity. Corrosive gases 3. Direct sunlight Handling 1. Operation Do not repeatedly operate the Switch with excessive force. Applying excessive pressure or applying additional force after the plunger has stopped may deform the disc spring of the Switch, resulting in malfunction. In particular, applying excessive force to Side-operated Switches may damage the caulking, which in turn may damage the Switch. Do not apply force exceeding the maximum (9.4 N for 1 minute, one time) when installing or operating Side-operated Switches. Be sure to set up the Switch so that the plunger will operate in a straight vertical line. A decrease in the life of the Switch may result if the plunger is pressed off-center or from an angle. Do not solder the Switch more than twice, including rectification soldering. An interval of five minutes is required between the first and second soldering.. Automatic Soldering Baths (B3F, B3W, B3WN, B3M, ) Soldering temperature: 0 C max. Soldering time: 5 s max. for a 1.-mm thick single-side PCB Preheating temperature: 100 C max. (ambient temperature) Preheating time: Within 0 s Make sure that no flux will rise above the level of the PCB. If flux overflows onto the mounting surface of the PCB, it may enter the Switch and cause a malfunction. 3. Reflow Soldering (Surface Mounting) Solder the terminals within the heating curve shown in the following diagram. B3S, B3SN, B3FS Temperature ( C) Max. 50 0 180 PCB surface Flux surface Operating part Plunger 150 Preheating. Dust Protection Do not use Switches that are not sealed in dust-prone environments. Doing so may cause dust to penetrate inside the Switch and cause faulty contact. If a Switch that is not sealed must be used in this kind of environment, use a sheet or other measure to protect it against dust. PCBs The Switch is designed for a 1.-mm thick, single-side PCB. Using PCBs with a different thickness or using double-sided, through-hole PCBs may result in loose mounting, improper insertion, or poor heat resistance in soldering. These effects will occur, depending on the type of holes and patterns of the PCB. Therefore, it is recommended that a verification test is conducted before use. If the PCBs are separated after mounting the Switch, particles from the PCBs may enter the Switch. If PCB particles or foreign particles from the surrounding environment, workbench, containers, or stacked PCBs become attached to the Switch, faulty contact may result. Soldering Incorrect Incorrect Correct Resin sheet Switch 1. General Before soldering the Switch on a multilayer PCB, test to confirm that soldering can be performed properly. Otherwise the Switch may be deformed by the soldering heat on the pattern or lands of the multilayer PCB. Note: The above heating curve applies if the PCB thickness is 1. mm. The peak temperature may vary depending on the reflow bath used. Confirm the conditions beforehand. Do not use an automatic soldering bath for surface-mounted Switches. The soldering gas or flux may enter the Switch and damage the Switch s push-button operation. 4. Manual Soldering (All Models) Soldering temperature: 350 C max. at the tip of the soldering iron Soldering time: 3 s max. for a 1.-mm thick, single-side PCB Before soldering the Switch on a PCB, make sure that there is no unnecessary space between the Switch and the PCB. Washing Room temperature 0 to 10 1. Washable and Non-washable Models Max. 0 Time (s) Washable (sealed types) B3W, B3WN, B3S, B3SN Non-washable (standard types) B3F, B3FS, B3M,, B3DA, B3D Standard Switches are not sealed, and cannot be washed. Doing so will cause the washing agent, together with flux or dust particles on the PCB, to enter the Switch, resulting in malfunction. 5

. Washing Methods Washing equipment incorporating more than one washing bath can be used to clean washable models, provided that the washable models are cleaned for one minute maximum per bath and the total cleaning time does not exceed three minutes. 3. Washing Agents Apply alcohol-based solvents to clean washable models. Do not apply any other agents or water to clean any washable model, as such agents may degrade the materials or performance of the Switch. +0.1 1.5 0 dia. 8±0.1 1.75±0.1 5.5 1±0.3 A Model B3FS-1000P B3FS-100P A 3.9 mm B3SN 3. mm 4. Washing Do not impose any external force on washable models while washing. Do not clean washable models immediately after soldering. The cleaning agent may be absorbed into the Switch through respiration as the Switch cools. Wait for at least three minutes after soldering before cleaning washable models. Do not use Sealed Switches while submersed in water or in locations exposed to water. Switch Packaging (Taping Specification Models) 3,000 Switches 50 C for 4 hours (without deformation) Note: Switches with ground terminals are packaged with the ground terminal on the opposite side of the guide hole. B3FS-1010P () 1. Radial Types The tape is packaged by fan-folding into the box, as shown in the following diagram. Switches on taping Packaging box Reel (Made of paper) 330 dia. Fan-folded tape C 1.5 dia. +0.1 0 1±0.1 1.75 (4.7) A B 7.5 1 Model A B C B3F 50 mm 35 mm 75 mm B3WN 53 mm 3 mm 350 mm Do not apply any external force to the packaging box, or subject it to vibration. Doing so may deform the Switch terminals. Remove the tape slowly, making sure that the Switches are not entangled or caught. Otherwise the terminals may be deformed. Do not store the packaged Switches in locations subject to high temperatures or high humidity. The packaging boxes are sealed with paper tape and are not airtight. Storing the packaged Switches in locations with high temperature or high humidity may result in deterioration of the tape and Switches, and long-term storage under such conditions may cause discoloration of the Switch terminals.. Packaging Specifications for Embossed Taping (B3FS-1000P/-100P, B3SN) (18) 1,000 Switches 0 C for 4 hours (without deformation) Reel 380± dia.

B3FS-1050P () LEDs () Make sure that the polarity of the LEDs is correct. The polarity is not indicated on the Switch, but the positive pole is located on the back surface of the Switch on the side without the OMRON mark. Connect limiting resistors to the LEDs. The Switch does not have built-in limiting resistors, so satisfy the LED characteristics by obtaining the limiting resistance according to the following formula based on the voltage to be used. Reel (made of paper) 380± dia. Limiting resistance (R)= (Voltage used (E) LED forward voltage (VF)) LED forward current (IF) (Ω) +0.1 1.5 0 dia. 1±0.1 1.75±0.1 (8.1) R E VF IF 7.5 1±0.3 1,000 Switches 0 C for 4 hours (without deformation) Forward current I F (ma) 50 40 30 Red Yellow/Green B3S 330 dia. 1.5 0 10 0 0 0 0 40 0 80 Ambient temperature Ta ( C) Reel +0.1 1.5 0 dia. 1±0.1 1.75 Forward current IF (ma) 50 30 10 5 Green Yellow 3 8.7 7 7.5 1 1 Red 0.0 9.4 1.5 0.4 0.5 1.5 1. 1.7 1.8 1.9.0.1 Forward voltage V F (V) 4.7 1,000 Switches 50 C for 4 hours (without deformation) Note: Switches with ground terminals are packaged with the ground terminal on the opposite side of the guide hole. 7