File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

C E R T I F I C A T E O F C O M P L I A N C E

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certificate of Compliance

File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Certificate of Compliance

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Bussmann series Quik-Spec Power Module Switch elevator disconnect

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Description. Positive safety relays

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Switches Unlimited Phone: * Fax:

Page 2-4 Page 2-8. Page Page 2-13

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: -Daten: U",", / U = 690V / U *o = 6kV Hersteller:

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

s A Confirmation Bestätigung

Micro Contactor MA Series

Electronic overload relays EF205 and EF370

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

4.1. Definite Purpose Contactors and Starters. Contents

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

ABB s new control and protection devices

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Selection Guide Motor Control Device Solutions

Submittal Data Information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

3RT14 Contactors with 3 Main Contacts

A302DN.40/.63A Thermal Current Motor Starter

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018

4 - Miniature controls

Short form catalogue Motor protection and control Block contactors and overload relays

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Product Specification Sheet #3LD2.1

Motor Starter Protectors

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable

Motor Starter Protectors

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

AF40... AF96 3-pole contactors Technical data

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT

Short form catalogue. Motor protection & control

SPEEDFAX TM 2011 Disconnect Switches Contents

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

Auxiliary contact blocks - with spring terminals Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Low-Peak 600V Class RK1

22AF 40AF AF 150AF 225AF 400AF 800AF

ASL09..S 3-pole Contactors - Spring Terminals

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

US Catalog. Motor protection and control AF Range contactors & overload relays

Technical data OT16E3 OT160E3 UL & CSA

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Control Circuit Protection

Components for EEx e Panels

NEMA Contactors & Starters (Freedom)

For Options, Modifications and Accessories, see pages Discount Schedule A6

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Certi 堵脝 cation Record

Devices for Branch Circuits and Feeders

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Self-protected Combination Starters System PKZ 2-SP

PowerPact B. Molded case circuit breakers and switches from A

Panorama. Contactors Motor protection Accessories

Thermal overload relay TF65 and TF96

Bussmann series Quik-Spec Coordination Panelboard

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker

Transcription:

File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

File E31519 Vol. 1 Sec. 89 Page 1 Issued: 2011-02-04 DESCRIPTION PRODUCT COVERED: USL, CNL - Type No. 3RT60, 3RT63, or 3RT65, followed by 23, 24, 25, 26, 27 or 28 followed by 1, 2 or 4 followed by A, B, C, D, E, F, K, N or X followed by a character and a number, followed by 0, 1, 2, 3, 4 or 8 may be followed by suffix letters and/or numbers. Accessories 3RT2916-4MA10, 3RT2926-4EB13 GENERAL: These devices are open types 3 pole contactors for use in industrial applications. These devices are intended to be used in combination with listed overload relays type 3RU6. The Accessories 3RT2916-4MA10 and 3RT2926-4EB13 are covers for use with the devices 3RT6 These devices may be used with line terminal adapters 3RV2925-5EB. In these applications, the incoming line terminal provides spacings not less than 2 inches (50.8 mm) measured over surface and 1 inch (25.4 mm) through air. ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE): USL - Indicates investigated to UL Standard UL 508 17 th September 2008(Industrial Control Equipment). Edition, updated CNL - Indicates Investigated to Canadian National Standard(s) C22.2 No. 14-10 Note: CNL = Canadian National Standards - Listed. USL = United States Standards - Listed.

File E31519 Vol. 1 Sec. 89 Page 2 Issued: 2011-02-04 RATINGS: Horsepower for Types 3RT6023 110-120 V 1-16 / 96 200 V 1-9.2 / 55.2 208 V 1-8.8 / 52.8 220/240 V 1-8 / 48 200 V - 2 7.8 / 57.5 208 V - 2 7.5 / 55 220/240 V - 3 9.6 / 64 380-415 V - 3 6.1 / 43 440/480 V - 5 7.6 / 46 550/600 V - 7 1/2 9 / 50.8 Horsepower for Types 3RT6024 110-120 V 1-16 / 96 200 V 1 1/2-11.5 / 69 208 V 2-13.2 / 79.2 220/240 V 2-12 / 72 200 V - 3 11.0 / 73.6 208 V - 3 10.6 / 71 220/240 V - 3 9.6 / 64 380-415 V - 5 9.7 / 61 440/480 V - 7 1/2 11 / 63.5 550/600 V - 10 11 / 64.8 Horsepower for Types 3RT6025, 3RT6325, 3RT6326, 3RT6327 110-120 V 1-16 / 96 200 V 2-13.8 / 82.8 208 V 2-13.2 / 79.2 220/240 V 3-17 / 102 200 V - 3 11 /73.6 208 V - 5 16.7 / 102 220/240 V - 5 15.2 / 92 380-415 V - 7 1/2 14 / 84 440/480 V - 10 14 / 81 550/600 V 15 17 / 93

File E31519 Vol. 1 Sec. 89 Page 3 Issued: 2011-02-04 Horsepower for Types 3RT6026 110-120 V 2-24 / 144 200 V 3-19.6 / 117.6 208 V 3-18.7 / 112.2 220/240 V 3-17 / 102 200 V - 5 17.5 / 105.8 208 V - 5 16.7 / 102 220/240 V - 7 1/2 22 / 127 380-415 V - 10 18 / 107 440/480 V - 15 21 / 116 550/600 V - 20 22 / 116 Horsepower for Types 3RT6027 110-120 V 2-24 / 144 200 V 5-30.4 / 182.4 208 V 5-30.8 / 184.8 220/240 V 5-28 / 168 200 V - 10 32.2 / 186.3 208 V - 10 30.8 / 179 220/240 V - 10 28 / 162 380-415 V - 20 34 / 194 440/480 V - 20 27 / 145 550/600 V - 25 27 / 146 Horsepower for Types 3RT6028 110-120 V 3-34 / 204 200 V 5-32.2 / 193.3 208 V 5-30.8 / 184.8 220/240 V 5-28 / 168 200 V - 10 32.2 / 186.3 208 V - 10 30.8 / 179 220/240 V - 10 28 / 162 380-415 V - 20 34 / 194 440/480 V - 25 34 / 183 550/600 V - 25 27 / 146

File E31519 Vol. 1 Sec. 89 Page 4 Issued: 2011-02-04 Horsepower for Types 3RT6526 110-120 V 2-24 / 144 200 V - - - 208 V - - - 220/240 V 3-17 / 102 200 V - - - 208 V - - - 220/240 V - 7 1/2 22 / 127 380-415 V - - - 440/480 V - 15 21 / 116 Horsepower for Types 3RT6023 (Elevator Use) 208 V -- 2 7.5 / 55 220/240 V -- 3 9.6 / 64 440/480 V -- 5 7.6 / 46 550/600 V -- 7 1/2 9.0 / 50.8 Horsepower for Types 3RT6024 (Elevator Use) 208 V -- 2 7.5 / 55 220/240 V -- 3 9.6 / 64 440/480 V -- 5 7.6 / 46 550/600 V -- 7 1/2 9.0 / 50.8 Horsepower for Types 3RT6025 (Elevator Use) 208 V -- 3 10.8 / 71 220/240 V -- 5 15.2 / 92 440/480 V -- 10 14.0 / 81 550/600 V -- 10 11.0 / 64.8 Horsepower for Types 3RT6026 (Elevator Use) 208 V -- 3 10.8 / 71 220/240 V -- 5 15.2 / 92 440/480 V -- 10 14.0 / 81 550/600 V -- 10 11.0 / 64.8

File E31519 Vol. 1 Sec. 89 Page 5 Issued: 2011-02-04 Horsepower for Types 3RT6027 (Elevator Use) 208 V -- 3 10.8 / 71 220/240 V -- 5 15.2 / 92 440/480 V -- 10 14.0 / 81 550/600 V -- 10 11.0 / 64.8 Horsepower for Types 3RT6028 (Elevator Use) 208 V -- 3 10.6 / 71 220/240 V -- 5 15.2 / 92 440/480 V -- 10 14.0 / 81 550/600 V -- 10 11.0 / 64.8

File E31519 Vol. 1 Sec. 89 Page 6 Issued: 2011-02-04 General Purpose Rating - Main Contacts 3RT6023/24/25/26: 600 V ac, 35 A 3RT6027/28: 600 V ac, 42 A AC Resistance 3RT6325 3RT6326 3RT6327 3RT6327 600 V ac, 30 A 600 V ac, 35 A 600 V ac, 38 A 600 V ac, 42 A (40 C Surrounding air temperature) Auxiliary Contacts A600/Q600 for the basic device 1-, 2- or 4-pole auxiliary contact blocks Type 3RH6911 or 3RH6921 are top or side mounted, for ratings refer to File E44653 Vol. 11 Sec. 30 or Vol. 12 Sec. 23. The auxiliary contact blocks are available as factory assembled (removable or not removable design) or available as separate devices for individual arrangements. Coil Ratings - 24 through 600 V ac, 12 through 240 Vdc Model 3RT6026 may be marked: May Replace NEMA Size 1 Contactor or equivalent. Standard Short Circuit Ratings: Fuse Class Circuit Breaker Type No. RK5, K5, CC J Comb. Mot. Ctlr. 3RV201 or 3RV202 Bkr TM Bkr I Short Circuit Current Voltage 3RT6023 - - 16 A - - 5 ka 480 V 3RT6024 - - 16 A - - 5 ka 480 V 3RT6025 - - 16 A - - 5 ka 480 V 3RT6026 - - 25 A - - 5 ka 480 V 90 A 125 A 12.5 A 70 A - 5 ka 600 V 3RT6027 - - 32 A - - 5 ka 480 V 125 A 150 A 12.5 A 70 A - 5 ka 600 V 3RT6028 - - 32 A - - 5 ka 480 V 125 A 150 A 12.5 A 70 A - 5 ka 600 V 3RT6325 - - 16 A - - 5 ka 480 V 3RT6326 - - 16 A - - 5 ka 480 V 3RT6327 - - 16 A - - 5 ka 480 V 3RT6526 - - 16 A - - 5 ka 480 V 90 A 125 A 12.5 A 70 A - 5 ka 480 V

File E31519 Vol. 1 Sec. 89 Page 7 Issued: 2011-02-04 High Capacity Short Circuit Ratings: Type No. Fuse Class J Comb. Mot. Ctlr. 3RV201 or 3RV202 Circuit Breaker Bkr TM Bkr I Short Circuit Voltage 3RT6023 60 A - - - 100 ka 600 V - 12.5 A - - 65 ka 480 V 3RT6024 60 A - - - 100 ka 600 V 12.5 A - - 65 ka 480 V 12.5 A - - 30 ka 600 V 3RT6025 60 A - - - 100 ka 600 V - 16 A - - 65 ka 480 V 3RT6026 90 A - - - 100 ka 600 V - 25 A - - 65 ka 480 V 3RT6027 110 A - - - 100 ka 600 V - 32 A - - 50 ka 480 V - 25 A - - 65 ka 480 V 3RT6028 125 A - - - 100 ka 600 V - 32 A - - 50 ka 480 V - 25 A - - 65 ka 480 V 3RT6325 60 A - - - 100 ka 600 V - 16 A - - 65 ka 480 V 3RT6326 60 A - - - 100 ka 600 V - 16 A - - 65 ka 480 V 3RT6327 60 A - - - 100 ka 600 V - 16 A - - 65 ka 480 V 3RT6526 90 A - - - 100 ka 600 V - 25 A - - 65 ka 480 V

File E31519 Vol. 1 Sec. 89 Page 8 Issued: 2011-02-04 Group Installation: Maximum Short-circuit rating in Group Installations (only in combination with Manual Motor Controller 3RV2) Type No. Man. Mot. Ctlr. 3RV2.1 or 3RV2.2 Short Circuit Voltage 3RT6023 12.5 A 1) 65 ka 480 V 3RT6024 12.5 A 1) 65 ka 480 V 3RT6025 16 A 1) 65 ka 480 V 3RT6026 25 A 1) 65 ka 480 V 3RT6027 40 A 1) 12 ka 480 V 32 A 1) 50 ka 480 V 25 A 1) 65 ka 480 V 3RT6028 40 A 1) 12 ka 480 V 32 A 1) 50 ka 480 V 25 A 1) 65 ka 480 V 3RT6325 16 A 1) 65 ka 480 V 3RT6326 16 A 1) 65 ka 480 V 3RT6327 16 A 1) 65 ka 480 V 3RT6526 25 A 1) 65 ka 480 V 1) Branch Circuit Protective Device for 480V-Ratings: The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-53 and the application. The following devices are permitted: Fuses: Classes RK1, RK5, J, G, T, CC or Circuit breakers: Listed Siemens type, with a marked shortcircuit rating equal or larger than the available short-circuit current rating These devices were tested for group installation use at the above levels without any upstream branch circuit device. 2) Branch Circuit Protective Device for 600V-Ratings: Max. Class J 100A

File E31519 Vol. 1 Sec. 89 Page 9 Issued: 2011-02-04 NOMENCLATURE BREAKDOWN: 3RT60 23-1 A B4 0 -... I II III IV V VI VII I. Basic Type 3RT60-3 main contacts + 2 to 6 auxiliary contacts 3RT63 4 NO main contacts + 2 to 6 auxiliary contacts 3RT65 2 NO + 2 NC main contacts + 2 to 6 auxiliary contacts II. Size 3RT60: 23 - rated 5 hp at 480 V 24 - rated 7 1/2 hp at 480 V 25 - rated 10 hp at 480 V 26 - rated 15 hp at 480 V 27 - rated 20 hp at 480 V 28 - max hp ratings, max FLA ratings 3RT63: 25 - rated AC Resistance 30 A at 600 V 26 - rated AC Resistance 35 A at 600 V 27 - rated AC Resistance 38 A at 600 V 3RT65: 26 - rated 15 hp at 480 V III. Type of Terminals 1 - Screw Terminal 2 - Spring Terminal 4 Ring lug terminals (wire binding screw) IV. Operating system A - AC operating system B - DC operating system C AC operating system with factory assembled EMC protective unit Varistor type 3RT6926 covered in file E44653 Vol. 9 Sec. 3 D, K DC operating system with factory assembled EMC protective unit varistor type 3RT6926 covered in file E44653 Vol. 9 Sec. 3 E AC operating system with factory assembled EMC protective unit RC combination type 3RT6926 covered in file E44653 Vol. 9 Sec. 3 F - DC operating system with factory assembled EMC protective unit diode combination type 3RT6926 covered in file E44653 Vol. 9 Sec. 3 N, X - UC operating system

File E31519 Vol. 1 Sec. 89 Page 10 Issued: 2011-02-04 V. Operating voltage 24 Vac through 600 Vac 12 Vdc through 240 Vdc VI. Auxiliary Contact Arrangements 0 1 normally open and 1 normally closed 1 1 normally open, top mounted 2 1 normally closed, top mounted 3-1 normally open and 1 normally closed, top mounted 4-2 normally open and 2 normally closed, top mounted 8 - any other, individual auxiliary contact arrangements VII. Suffix letters and/or numbers specified commercial variations -0CC0 contactor with communication interface -... any other commercial variation 3RT2916-4MA10 - Sealable cover 3RT2926-4EB13 - Cover set for devices with ring lug terminals 3RT602.-4..