O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Similar documents
The installation and maintenance of this product must be done under the supervision of an experienced

Commonwealth of Massachusetts Approved Product Approval code G

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

Locktite Manual Reset Gas Shut-Off Valves

Pressure Switch with Gauge for Pressure

Powers TM Controls SW 141 Differential Static Airflow Switches

VACUUM A RESOURCE FOR EVERYONE

Introduction. System Components

Eclipse AutoTite Automatic Gas Shut-Off Valves

Eclipse AutoTite Automatic Gas Shut-Off Valves

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Installation and Operation Instructions DLP Series

9012G Pressure and 9016G Vacuum Switches

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

MA-5200 Series MA-5300 Series

2-Way/2 Position Valves

DW PADDLE-BELLOWS FLOWMETER & SWITCH

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

I-BFV.KIT Butterfly Valve Gear Operator Replacement

37T Series Moisture Resistant Temperature Controls

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Flow Computer Installation

Bourdon Tube Pressure Switches

North American Automatic Manual Reset and Motorized Valves

Differential pressure switch for monitoring air pressure in HVAC systems.

P70, P72 and P170 Series Controls for High Pressure Applications

Model 124 Filter Minder & Model 124

MF /MS Series

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

P70, P72, and P170 Series Controls for High Pressure Applications

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Differential Pressure Switch QBM81-

Data Sheet. A-Series Miniature Watertight Pressure Switches. Factory set or field adjustable

Product Catalogue. Electromechanical controllers REL

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Data Sheet. A-Series Miniature Watertight Pressure Switches

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Differential Pressure Switch QBM81-

Table of Contents. HCC Contactor Nomenclature

P70, P72, and P170 Controls for Low Pressure Applications

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

M-100 Series. Adjustable flow switch with right-angle flow

ECLIPSE TURBO BLOWERS SERIES SMJ

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Pressure switch for gas, GW 500 A4 GW 500 A4/2

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Screwed Brass Orfices (SBO) 1/2-2 1/2 NPT; rated 250 PSI. Carbon Steel Orfices (CO) 2 1/2-24 ; rated 250 PSI ATTENTION

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Signet Pressure Transmitter

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Series 20 Installation Instructions

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

VE VVG Series Electronic Two-way Valves Normally Closed

Signet Pressure Transmitter

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

PISTON STYLE GAUGE. Mid-West Instrument

Surface mounting, flush mounting, and DIN track mounting

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

M9216 Series Electric Spring Return Actuators

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

L404F,T,V PressureTrol Controllers

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

System 350 P352AB Electronic Pressure Control Series

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Data /1/07 Eclipse RatioAir Burners Model RA0040

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

B21 Series BASOTROL Gas Valve

Condensed Catalog 2006 North America

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

AQUASTATS THERMOSTAT APPLICATION

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

SERIES 1000 ELECTRIC ACTUATORS

Signet Temperature Transmitter

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Product Information Page

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Figure 1: WPR2 Dimensions and Hardware

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Safety Limit Switch

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Transcription:

AA...A2 Differential Air Pressure Switch Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Model Description & Part Number... Page 2 Operation...Page 2 Pressure Connection & Mounting AA...A2-4.. Page 3 Pressure Connection & Mounting AA...A2-6.. Page 3 Installation Position...Page 3 Application & Connection Examples...Page 4 Wiring...Page 4 Operation & Adjustment.... Page 4 Maintenance & Testing... Page 5 Accessories & Replacement... Page 5 Approvals UL Listed: UL 353 File # MH 16628 CSA Certificate: CSA C22.2 No. 14 File # 201527 FM Approved: Class 3510, 3530 File # J.I.0D6A1.AF Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Attention The installation and maintenance of this product must be done under the supervision of an experienced and trained specialist. Never perform work if gas pressure or power is applied, or in the presence of an open flame. [V] [A] [Hz] [VA] Check the ratings in the specifications to verify that they are suitable for your application. 1 5 Explanation of symbols 1, 2, 3... = Action = Instruction Please read the instruction before installing or operating. Keep the instruction in a safe place. You find the instruction also at www. dungs.com. If these instructions are not heeded, the result may be personal injury or damage to property. Any adjustment and applicationspecific adjustment values must be made in accordance with the equipment manufacturers instructions. Safety first O.K. IFGC CSA UL ANSI NFPA On completion of work on the, perform a leakage and function test. This product is intended for installations covered by, but not limited to, the following codes and standards: NFPA 54, IFGC (International Fuel Gas Code) or CSA B149.1 (for Canada) or the following equipment codes and standards: NFPA 86, ANSI Z83.4/ CSA 3.7, ANSI Z83.18/CSA 4.9, ANSI Z21.13, CSD-1, UL 195, CSA B149.1 or CSA B149.3

Specification AA...A2 SPDT differential in pressure and vacuum ranges. The differential pressure acts via the diaphragm against the force of the setting spring on the microswitch. The operates without any auxiliary power. Max. Operating Pressure MOP = 7 PSI (500 mbar) F +140 Ambient / Medium Temperature -40 F... +140 F (-40 C +60 C) [PSI] 0-40 Ag [V] [A] [Hz] [VA] Electrical Connection Screw terminals via 1/2 NPT conduit connection Contact Rating 5 A resistive, 3 A inductive @ 120 VAC 1 A max. @ 12-48 VDC Gas Gases Air and non-aggressive gases only. Not suitable for natural gas, propane, butane or other combustable gases. Materials in contact with Gas Housing: Polycarbonate Switch: Polycarbonate Diaphragm: NBR-based rubber Switching contact: Silver (Ag) [A] NEMA Enclosure NEMA Type 4 SPDT Switch SPDT Switch action Pressure, vacuum of differential Model Description & Part Number Type Version Description Order No. Setting range AA-A2-4- AA-A2-6- AA-A2-4-2 AA-A2-4-3 AA-A2-4-5 AA-A2-4-6 AA-A2-6-2 AA-A2-6-3 AA-A2-6-5 AA-A2-6-6 217-060A 217-061A 217-062A 217-063A 217-329A 217-330A 217-331A 217-332A 0.16-1.20 0.40-4.00 2.00-20.00 12.00-60.00 0.16-1.20 0.40-4.00 2.00-20.00 12.00-60.00 Switching hysteresis 0.12 0.20 0.40 1.2 0.12 0.20 0.40 1.2 Factory Calibration Operation Definition of switching hysteresis p The pressure difference between the upper and lower switching pressures. Pressure at meter Switching hysteresis Δp Setpoint tolerance Adjustment as pressure rises Upper switching pressure Rising Falling Lower switching pressure 2 5

3 Pressure Connection & Mounting AA...A2-4 AA...A2-4 Hose Connection (1) Pressure connection (+) Ø 0.18 (2) Pressure connection ( ) Ø 0.18 (1) AA...A2-4 Mounting Procedure Use suitable hoses for the medium. Use a maximum 5/32 ID. hose Secure the hoses with a cable tie or a cable clip. (2) 1/2 NPT Pressure Connection & Mounting AA...A2-6 AA...A2-6 Threaded Connection Pressure connection (+) 1/4 NPT Pressure connection ( ) 1/4 NPT Test nipple p (+) Ø 0.18 AA...A2-6 Mounting Procedure Apply good quality pipe sealant to the male threads only. Use 13/16 Wrench to secure the switch to the pipe. DO NOT Exceed 45 lb-in of Torque on 1/8 Connections DO NOT Exceed 60 lb-in of Torque on 1/4 Connections After installation is complete, perform a leak test. Test button (for AA-A2-6 series only) When the test button is pressed the 1/4 NPT pressure connection is interrupted and the pressure below the diaphragm is relieved. The changes the contact position from NO to NC. When the test button is released, the pressure is built up again and the switch changes to its original position. Installation Position (2) 1/8 NPT (2) 1/8 NPT (1) 1/4 NPT 1/2 NPT Pressure connection can only be used as test nipple. (3) Test Nipple Test Button Standard installation position is vertical upright diaphragm. When installed horizontally, the switches at a pressure higher by approx. 0.2 When installed upside down, the switches at a pressure lower by approx. 0.2 α Adjustment The scale indicates the setpoint when switch is mounted in the vertical position and increasing pressure. When installed in other positions, the switches at pressure deviating from the set reference value by max. ± 0.2 0, 9 1,2 1,5 0,6 0,4 AA...A2 2,4 2,7 3 5 1,8 2,1

Application & Connection Examples Connection p1 must remain open Connection p2 Connection p1 Connection p2 Connection p2 Connection p1 System vacuum monitor AA...A2 is connected to the air duct with the p2 (-) connection. p1 (+) is not connected with the air duct. Do not seal the p1 (+) connection; it must be open to the atmosphere. Prevent dirt from entering into the device through connection p1(+) Filter monitoring To monitor a filter, the AA...A2 can be connected as shown above. Blower monitoring For blower monitoring, connect connection p1 (+) to the air duct on the downstream side of the blower and connection p2 (-) to the air duct upstream of the blower. Wiring 1. Remove the clear cover from the switch. 2. Use 14 or 16 AWG wire rated for at least 75 C. 3. Route the wires through the conduit connector. 4. Connect the wiring to the appropriate screw terminals. 5. Replace the clear cover from the switch. AA...A2 switching function As pressure rises above setpoint: 1 NC opens, 2 NO closes All wiring must comply with local electrical codes, ordinances and regulations. Medium Pressure As pressure falls below setpoint: 1 NC closes, 2 NO opens Do not exceed the switch ratings given in the specifications and on the switch. Operation & Adjustment Adjusting the Set Point 1. Remove the clear cover ➊ from the switch. 2. Adjust the switch to the desired set point by turning the dial. The white arrow on the dial indicates the set point ➋. 3. After adjusting the set point, verify that the operates as intended by using an accurate pressure gauge connected upstram of the switch. 4. Replace the clear cover. Automatic Reset and Operation The NC contact of the AA...A2 breaks when pressure rises above the set point. It makes automatically when pressure falls below set point. ➋ ➊ 4 5

Maintenance & Testing Annually check the switch for proper operation Set Point Calibration Connect a meter capable of reading +/- 0.1 ohms to the NC and COM contacts. Measure the resistance across the NC and COM contacts. If the resistance is more than 1.0 ohm, the switch switch should be replaced, since this indicates that the switch contacts are starting to either corrode or carbonizing. Apply appressure to the + air pressure connection, and confirm that the NC contact breaks when pressure rises above the set point and that the NO contact makes. the NC contact will make automatically when pressure falls below the set point pressure. Connect a meter capable or reading +/- 0.1 ohms to the NO and COM contacts. Measure the resistance across the NO and COM contacts. If the resistance is more than 1.0 ohm, the switch switch should be replaced, since this indicates that the switch contacts are starting to either corrode or carbonizing. Accessories & Replacement Accessory for Order No. Klima-Set (Duct mounting kit) 214-828 Replacement cover 228-732 Mounting plate (flat plastic) 230-301 (recommended mounting bracket) Mounting bracket (plastic) (1 pcs) 230-273 (optional mounting bracket) 120 VAC light mounting set (orange) 231-772 120 VAC light only 244-156 (for switches with kit 231-772 already installed) 24 VDC/VAC light mounting set (orange) 231-774 120 VAC light mounting set (green) 248-240 PG 11-1/2 NPT conduit adapter (10 pcs) 231-214 PG 11-1/2 NPT conduit adapter (1 pcs) 220-566 DIN connector 210-318 We reserve the right to make modifications in the course of technical development. 5 5 Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Tel: 804-236-3881 Fax: 804-236-3882 www.burnerparts.com