DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Similar documents
DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ON-SITE WASTEWATER PRODUCTS

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

PREINSTALLATION CHECKLIST

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

507/53 507/98 CAUTION. NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

CAUTION PREINSTALLATION CHECKLIST. visit our web site: Your Peace of Mind is Our Top Priority. Section: 6.10.

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

PRE-PLUMBED SEWAGE SYSTEM

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

OWNER S MANUAL Commercial Duty Pumps

MODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

ESE Series Cast Iron Sewage Pumps

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

OWNER S MANUAL MODEL 404/4404 AND

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

GARDEN HOSE UTILITY PUMP

OWNER S MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS SAFETY INSTRUCTIONS TABLE OF CONTENTS OWNER S INFORMATION. visit our web site:

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

S2n1 PREASSEMBLED SUMP PUMP SYSTEM

OWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

S MANUAL 64 HD SERIES SUBMERSIBLE NON-CLOG UNITS

OWNER S MANUAL X71 HAZARDOUS ENVIRONMENT SERIES CLASS I, DIVISION 1, GROUP C & D SUBMERSIBLE GRINDER UNITS CAUTION

OWNER S MANUAL 6680 SERIES SUBMERSIBLE NON-CLOG UNITS

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

StormPro BA Series Sump Pump

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

S MANUAL 61 HD SERIES SUBMERSIBLE NON-CLOG UNITS

2460 / 2472 / Series Simplex Grinder Systems

Potable Water Submersible Turbine Pumps

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

SHEF30 Submersible Sump/ Effluent Pump

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

StormPro BCV400 Sewage Ejector Pump

Owner s Manual Drill and Light Weight Portable Utility Pumps

OWNER S MANUAL 62 HD SERIES SUBMERSIBLE NON-CLOG UNITS. Table of Contents. Safety Instructions. Owner s Information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Ion Technologies WC33 Submersible Sump Pump

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SUBMERSIBLE SWIMMING POOL DRAINER

HALLMARK INDUSTRIES INC

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

REPAIR MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS CAUTION

Powerful & Intelligent Submersible Pumps

SUNC3000 / Item #40885

Matala. VersiFlow Series. Instruction and Maintenance Manual

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

MODEL 900 IMPELLER-TYPE FLOW METER

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

MODELS 7008, 7009, 7010 SUBMERSIBLE GRINDER UNITS

GeyserMax-Flow Series

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

OWNER S MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS. Safety Instructions. Table of Contents. Owner s Information

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

OWNER S MANUAL MODELS 810 & 815 PROGRESSING CAVITY GRINDER PUMPS

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

SUBMERSIBLE PUMP HSE RANGE

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Pressure Booster System Models 350 & 351

SP40 Submersible Sewage Ejector Pump

Pump Installation and Service Manual HRS Hydromatic Retractable System

EBARA Fluid Handling

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

PARTS AND INSTALLATION MANUAL

SUBMERSIBLE PUMP HSE RANGE

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

50/60 Hz REPAIR MANUAL 61 HD SERIES HEAVY-DUTY SOLIDS HANDLING PUMPS. Table of Contents. Safety Instructions. To Order Replacement Parts

AEROMOTIVE Part # Ford 5.0 Liter INSTALLATION INSTRUCTIONS

Transcription:

Notice to Installer: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. C U P C COMPLIES WITH ASME A2.3.4 and CSA B45.9 * MODEL 04 IS NOT IAPMO APPROVED. MAIL TO: P.O. BOX 6347 Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road Louisville, KY 402-96 TEL: (502) 778-273 (800) 928-PUMP FAX: (502) 774-3624 DRAIN PUMP SYSTEMS MODELS 04*, 05, 0, 5, 20, 3 INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Visit our web site: zoellerpumps.com FM2336 25 Supersedes 062 MODEL: DATE CODE: DATE INSTALLED:. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs from the pump. 2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference. SEE BELOW FOR LIST OF WARNINGS. To reduce the risk of electrical shock, a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter (GFCI) and in accordance with National Electrical Code and local codes. (SEE WARNING BELOW) 2. Make certain that the receptacle is within the reach of the pump s power supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver sufficient voltage to the pump motor. But more important, they could present a safety hazard if the insulation were to become damaged or the connection end were to fall into the sump. 3. Testing for Ground. As a safety measure, each electrical outlet should be checked for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power, neutral and ground wires are correctly connected to your outlet. If they are not, call a qualified electrician. 4. For Added Safety. Pump must be connected to a 3-prong grounded outlet interrupter device (ground fault circuit interrupter). 5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. To reduce the risk of electrical shock, a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter (GFCI) in accordance with national electrical code and local codes. 6. Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician. 7. Risk of electric shock - These pumps have not been investigated for use in swimming pool areas. 8. According to the state of California (Prop 65), this product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. CAUTION SEE BELOW FOR LIST OF CAUTIONS. Check to be sure your power source is adequate for handling the voltage requirements of the motor, as indicated on the pump or basin plate. 2. Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate branch circuit is recommended, sized according to the National Electrical Code for the current shown on the pump name plate. 3. All plumbing (discharge and vent lines) must be installed to meet local codes. Unit must be vented. DO NOT USE AN AUTOMATIC PLUMBING VENT DEVICE SIMILAR TO A "PRO-VENT". Some states require this product to be installed by a licensed plumber. 4. Repair and service should be performed by Zoeller Pump Company Authorized Service Station only. 5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING OF PUMP. Check valve must be purchased separately on model 04 only. 6. Dewatering pumps are not designed or intended for handling raw sewage. 7. Maximum operating temperature for 05-3 Drain Pumps must not exceed 30 F (54 C). 04 Drain Pumps are not to exceed 0 F (43 C). 8. For health reasons, do not unplug, turn off, or disable pump and use pump tank system as a way to fill up a sink or laundry tray, etc. 9. Unit is designed for above ground installation only. Pumps with the UL mark and pumps with the US mark are tested to UL Standard UL778. CSA Certified pumps are certified to CSA Standard C22.2 No. 08. REFER TO WARRANTY ON PAGE 2. P/N 07583

Limited Warranty Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, every new product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of one year from date of purchase by the end user, or 8 months from date of original manufacture of the product, whichever comes first. Parts that fail within the warranty period, one year from date of purchase by the end user, or 8 months from the date of original manufacture of the product, whichever comes first, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturer's option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer's installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products. Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 402, Attention: Customer Support Department to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty. MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Service Checklist ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump - making sure you are not standing in water and wearing insulated protective sole shoes. Under flooded conditions, contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal. Submersible pumps can become pressurized under normal operating conditions allow 2½ hours after disconnecting before attempting service. CONDITION A. Pump will not start or run. B. Motor overheats and trips overload or blows fuse. C. Pump starts and stops too often. D. Pump will not shut off. E. Pump operates but delivers little or no water. F. Drop in head and/or capacity after a period of use. G. If tank or fittings leak. COMMON CAUSES Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically, defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective, damaged, or out of adjustment. Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defective capacitor or relay, motor shorted. Float too tight on rod, check valve stuck, or none installed in long distance line, overload open, switch defective. Debris under float assembly, float or float rod bound by basin sides or other, switch defective, damaged or out of adjustment. Check strainer housing, discharge pipe, or if check valve is used, the vent hole must be clear. Discharge head exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water containing air or causing air to enter pumping chamber. Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly deteriorate impeller and pump housing. Check line. Remove base and inspect. Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do not over tighten fittings or screws. If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must be by a Zoeller Authorized Service Station. 2

Ten Helpful Hints For Easy Installation. Read all instructions before beginning installation. 2. Be certain that basin is on a firm level surface. 3. Do not use an automatic plumbing vent device. 4. Do not over-torque lid attachment screws. 5. Always use a check valve on the discharge line. 6. Test operation of pump per STEP 6. 7. Always provide some means to disconnect basin from plumbing for maintenance purposes. 8. Run unit at least once a month to verify proper operation. 9. The model number and date code can be found on the lid warning label. 0. Plug pump into a properly grounded GFCI receptacle. Do s And Don't s For Installing A Unit. DO read all installation material included with the pump. 2. DO inspect unit for any visible damage caused by shipping. Contact dealer if unit appears to be damaged. 3. DO clean all debris from the basin and pump. 4. DO always disconnect pump from power source before handling. DO always connect to a separately protected and properly grounded ground fault protected circuit. DO NOT ever cut, splice or damage power cord. DO NOT carry or lift pump by its power cord. DO NOT use an extension cord. 5. DO NOT use a discharge pipe smaller than the pump discharge size. 6. DO test pump immediately after installation to be sure that the system is working properly. 7. DO review all applicable local and national codes and verify that the installation conforms to each of them. 8. DO NOT install unit in the ground. Performance Characteristics METERS FEET PUMP PERFORMANCE CURVE 04/05/0/5/20/3/32 25 TOTAL DYNAMIC HEAD 6 20 5 4 0 2 5 0 GALLONS LITERS 0 0 20 04/32 30 40 05/0/ 5/20 50 80 60 FLOW PER MINUTE 60 70 240 3 80 MODELS Feet Meters 5.5 0 3.0 5 4.6 20 6. Shut-off Head: 04/32 05/0 5/20 3 Gal. Liters Gal. Liters Gal. Liters 38 44 43 63 72 273 30 4 34 29 6 23 4 53 9 72 45 70 -- -- -- -- 25 95 8 ft. (5.5m) 9.25 ft. (5.9m) 23 ft. (7.0m) 009898 3

STEP Determine Installation Configuration NOTE: The basin is designed to be installed directly under the sink (Internal Trap) or on the side (standard). IMPORTANT! Check local and state codes before using the internal trap option..) Figure.A and.b are typical configurations for installation of the drain systems. The actual configuration will vary depending on your cabinet and sink configuration. NOTE: If installing the internal trap, record the x dimension, it will be required in Step 4.! INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS. PIPING SHOWN ONLY FOR CLARITY. X (4" MIN.) SEE NOTE Figure.A INTERNAL TRAP PIPING SHOWN ONLY FOR CLARITY. Figure.B STANDARD (EXTERNAL TRAP) SK200 4

STEP 2 Install the Discharge Pipe onto the Pump ( All Models) WEEP HOLE DISCHARGE PIPE IMPORTANT! BE SURE THAT WEEPHOLE IS NOT DIRECTED TOWARD THE FLOAT! Water stream will be visible from this hole during pump run periods. PUMP DISCHARGE Figure 2. SK2002 STEP 3 Installation of the Gasket 3.) Install the gasket into the gasket seat at the top of the basin, refer to Figure 3. for details. ENSURE NOTCHES LINE UP SEAL SEAL DETAIL BASIN Figure 3. SK2972 5

STEP 4 Internal Trap Installation Only 4.) Cut the tailpipe to the dimension determined in Figure 4.. 4.2) Install the sink drain components to the lid as shown in Figure 4.2. 4.3) Orient the lid assembly as shown in Figure 4.3 and secure the trap components. (HAND TIGHTEN the assembly to the lid at this time. Adjustment will be required in Step 5.) Note: To ensure a proper water seal, the extension must be installed as shown in the trap detail. INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS. TRAP DETAIL TAILPIPE LENGTH X 4 /2" DIMENSION MEASURED IN STEP. TAIL PIPE 4" Figure 4. INLET TRAP FLANGED TAIL PIPE (SEE NOTE) Figure 4.2 TAIL PIPE TRAP DISCHARGE PARTIALLY VISIBLE THROUGH THE CORD SEAL OPENING. CORD SEAL OPENING DISCHARGE VENT Figure 4.3 SK2004 6

STEP 5 Final Assembly NOTE: External plumbing configuration will vary depending on the location of basin, location of main stack and available space. 5.) Place the pump in the basin as shown in Figure 5.. NOTE: If installing the internal trap, rotate the tail pipe to the orientation shown in Figure 5.. 5.2) Install the lid components as shown in Figure 5.2. NOTE: Pull excess cordage through the opening and install the cord seal as shown in Figure 5.3A. Insure o-ring is in the cap before installation. 5.3) Place the basin assembly in its final position and complete plumbing. Secure all connections (shown in 5.3A or 5.3B). TRAP INLET 2" SLP x NPT /2" SLP x NPT (APPLY SEALANT TO THREADS) O-RING CORD SEAL /4-20 x -/8" S.S. SCREWS /4-20 STD. S.S. FLAT WASHERS CAP DISCHARGE PIPE KEY Figure 5. SK2005 CAP SECTION VIEW SEE NOTE O-RING /4-20 STD. S.S. FLAT WASHERS CAP /4-20 S.S. NUTS (TORQUE TO 35 IN-LB) Figure 5.2 SK2007A UNION (PURCHASED SEPARATELY) UNION (PURCHASED SEPARATELY) INLET DISCHARGE PIPE CAP DISCHARGE PIPE GFCI OUTLET CORD SEAL CORD SEAL CHECK VALVE * CHECK VALVE * INLET GFCI OUTLET CAP INTERNAL TRAP INSTALLATION *CHECK VALVE MUST BE PURCHASED SEPARATELY STANDARD INSTALLATION Figure 5.3A FOR MODEL 04 & 32-0005. Figure 5.3B SK2006 STEP 6 Initial Testing of Drain Basin System 6.) Plug the cord into a properly grounded GFCI receptacle. 6.2) Fill tank with water. 6.3) Check all plumbing for leaks as the basin fills. 6.4) Verify that the pump starts and stops. 6.5.) Check the discharge line for leaks as the pump empties the basin. 6.6.) Repeat steps 6.2 to 6.5 as necessary to insure proper operation. 6.7.) If problems persist refer to the troubleshooting guide located on page 2 of this manual. 7

Illustrated Parts Breakdown ITEM DESCRIPTION QTY Replacement pump - M53/ M55/M57/M59 (5V) Replacement pump - M98 (5V) Replacement pump - M72 (5V) MODELS 05-D 0-D 5-D 20-D 3-C 04-D M53 00797 M53 (25' cord) 529 M53 (35' cord) 5220 M55 00798 M57 00799 M59 007920 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M98 00792 M98 (35' cord) 506 N/A N/A N/A N/A N/A N/A N/A N/A M72 72-000 2 Basin - Tank 0307 0307 0307 0307 0307 0307 3 Discharge Pipe 03732 03732 03732 03732 04759 03732 4 Basin - Cover 0308 0308 0308 0308 0308 0308 5 Hardware Pack & Seal 526 526 526 526 526 526 6 Seal 52607 52607 52607 52607 52607 52607 7 Unicheck 30-08 30-08 30-08 30-08 30-08 30-08 Notes: Hardware pack consist of (8) /4"-20 x /8" long round head stainless steel machine screws, (8) # ¼" - 20 stainless steel hex huts and (6) ¼" flat stainless steel washers along with () pipe cap and () o-ring. MODEL 05/0/5/20/3 MODEL 04 5 5 7 CHECK VALVE (PURCHASED SEPARATELY) 7 4 4 3 3 6 6 2 2 SK2008A SK2008B