Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

Similar documents
CMS Electric Cylinder. Addendum to the Operating Instructions. Edition 11/ / EN

Operating Instructions

Drive Technology \ Drive Automation \ System Integration \ Services. Revision MOVIFIT FC

Data sheet. MOVITRAC 07B, MOVITRAC 07A Information regarding UL * _1216*

Revision MOVITRAC LTE-B * _1114*

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

Manual. Conversion Aid MOVIDRIVE MDR60A Regenerative Power Supply Unit Series from DCV185 to DCV200

Data sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL * _0119*

Industrial Gear Units: Bucket Elevator Drives of the MC... / M... Series

Catalog DRE Gearmotors (IE2)

Data Sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL

Catalog. Variable Speed Gearmotors. Edition 08/2004 A3.D / EN

* _1217* Drive Technology \ Drive Automation \ System Integration \ Services. Catalog. AC Motors DRN80 315

Correção das Instruções de Operação

Addendum to the Operating Instructions

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315*

* _0916* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Synchronous Linear Motors SL2

Kasutusjuhendi parandus

Gearmotors \ Industrial Gear Units \ Drive Engineering \ Drive Automation \ Services. Gearmotors A3.D01. Catalog. Edition 04/ / EN

Correcties bij de technische handleiding

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Eksploatacijos vadovo pataisa

Drive Technology \ Drive Automation \ System Integration \ Services. Käyttöohjeen korjaus MOVITRAC LTP-B/LTX, LTP-A, LTE-B

High speeds and high torque ratings combines precision with high economic efficiency

Operating Instructions

ABB industrial drives. Supplement ACS N7502 drives for SynRM motors (0.8 to 200 kw)

Manual. Brake Diagnostics (as of V ) * _0415* Phone: Fax: Web: -

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Installation Instructions

Variable speed drive ALSPA MV1000. Power Conversion. General Drives

SIMOREG DC Master. Application SIMOREG as a field supply unit. 6RA70 Series

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

NEW Explosion protection

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

Catalog. Servo Gearmotors (R, F, K and S Gear Units) Edition 01/2005 DB / EN

E / HYDAC KineSys Electric cylinders (HEZ)

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Ändring av montage- och driftsinstruktionen

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Number 1 in efficiency

Edition. DTE / DVE Energy Efficient Motors 10/2003. Catalog / EN

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

Certificate of Conformity self-generation unit

Drive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL

Always on the safe side: Reliable plant operation with explosion-proof gear units, motors and geared motors

Addendum to the Assembly and Operating Instructions

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

SSW07. Soft Starters. Applications. Standard Features

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Catalog. Industrial Gear Units of the MC... Series. Edition 04/2005 D3.B / EN

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Operating Instructions

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

Operating Instructions

Revision to the Catalog and to the Operating Instructions , , ,

D Series: UPS UPTO - 300KVA - Three / Three Phase

Addendum to the Operating Instructions

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

HOPPECKE Lithium-ion battery systems

Latest News ECDriveS 24 V drive system for roller conveyors

EPS/ELA-Series User Manual EPS/ELA 250W

Drive System Application

pag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag.

SINAMICS GM150 IGCT version

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Lenze. Global Drive 9300 servo inverters kw

Centrifugal fan with highly efficient EC drive motor

ARCAPRO positioner. Positioner customized for specific tasks

Benefits. transmission devices (gearboxes, pulleys, gears, conveyers, etc) Soft-Star ters are static star ting switches, designed for the

* _1015* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Drive Unit MGF..-DSM

MOVIMOT. Operating Instructions Category 3D (Dust Explosion Protection) Edition 03/ X / /011/98


Addendum to the Assembly and Operating Instructions

Drive System Application

HVW701 HVAC Drive with By-Pass

Crane and Hoist Solution Guide. The Advantage of Experience

SP PRO KACO Managed AC Coupling

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

ABB industrial drive ACS800 multidrive, 1.5 kw kw ACS800 multidrive modules, 1.5 kw kw Technical catalogue

J1000. Compact Inverter Series.

Addendum to the Operating Instructions

Cabinet-built single drives, ACS880-07

PHOENIX CONTACT - 01/2008

Number 1 in efficiency

3RW Soft Starters. General data. 6/4 Siemens LV

Addendum to the Operating Instructions

MOVIMOT mounting close to the motor (remote)

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

L300P Inverter Specifications

MULTI LANGUAGE KEYPAD

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Electrical Engineering Info

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B Edition 07/2008 16658019 / EN Revision

1 Notes 1 Notes NOTES This supplementary information does not replace the detailed operating instructions! Startup only by trained personnel observing the relevant accident prevention regulations and the following documents: MOVITRAC B operating instructions Explosion-proof AC motors, asynchronous servomotors operating instructions The section numbers are provisional. The information will be arranged correctly in the next edition of the system manual. 2 Revision MOVITRAC B

MOVITRAC System Description The units at a glance kva i P f n Hz 2 2 MOVITRAC System Description 2.1 The units at a glance Supply system connection 230 V 1-phase 230 V 3-phase 400 V 3-phase Motor power Rated output current MOVITRAC B type 0.25 kw / 0.34 HP AC 1.7 A MC07B0003-2B1-4-00 0.37 kw / 0.50 HP AC 2.5 A MC07B0004-2B1-4-00 0.55 kw / 0.74 HP AC 3.3 A MC07B0005-2B1-4-00 0.75 kw / 1.0 HP AC 4.2 A MC07B0008-2B1-4-00 1.1 kw / 1.5 HP AC 5.7 A MC07B0011-2B1-4-00 1.5 kw / 2.0 HP AC 7.3 A MC07B0015-2B1-4-00 2.2 kw / 3.0 HP AC 8.6 A MC07B0022-2B1-4-00 0.25 kw / 0.34 HP AC 1.7 A MC07B0003-2A3-4-00 0.37 kw / 0.50 HP AC 2.5 A MC07B0004-2A3-4-00 0.55 kw / 0.74 HP AC 3.3 A MC07B0005-2A3-4-00 0.75 kw / 1.0 HP AC 4.2 A MC07B0008-2A3-4-00 1.1 kw / 1.5 HP AC 5.7 A MC07B0011-2A3-4-00 1.5 kw / 2.0 HP AC 7.3 A MC07B0015-2A3-4-00 0L 2.2 kw / 3.0 HP AC 8.6 A MC07B0022-2A3-4-00 3.7 kw / 5.0 HP AC 14.5 A MC07B0037-2A3-4-00 1 5.5 kw / 7.4 HP AC 22 A MC07B0055-2A3-4-00 7.5 kw / 10 HP AC 29 A MC07B0075-2A3-4-00 2 11 kw / 15 HP AC 42 A MC07B0110-203-4-00 15 kw / 20 HP AC 54 A MC07B0150-203-4-00 3 22 kw / 30 HP AC 80 A MC07B0220-203-4-00 30 kw / 40 HP AC 95 A MC07B0300-203-4-00 4 0.25 kw / 0.34 HP AC 1.0 A MC07B0003-5A3-4-00 0.37 kw / 0.50 HP AC 1.6 A MC07B0004-5A3-4-00 0.55 kw / 0.74 HP AC 2.0 A MC07B0005-5A3-4-00/S0 0.75 kw / 1.0 HP AC 2.4 A MC07B0008-5A3-4-00/S0 1.1 kw / 1.5 HP AC 3.1 A MC07B0011-5A3-4-00/S0 1.5 kw / 2.0 HP AC 4.0 A MC07B0015-5A3-4-00/S0 2.2 kw / 3.0 HP AC 5.5 A MC07B0022-5A3-4-00/S0 3.0 kw / 4.0 HP AC 7.0 A MC07B0030-5A3-4-00/S0 0L 4.0 kw / 5.4 HP AC 9.5 A MC07B0040-5A3-4-00/S0 5.5 kw / 7.4 HP AC 12.5 A MC07B0055-5A3-4-00 7.5 kw / 10 HP AC 16 A MC07B0075-5A3-4-00 2S 11 kw / 15 HP AC 24 A MC07B0110-5A3-4-00 2 15 kw / 20 HP AC 32 A MC07B0150-503-4-00 22 kw / 30 HP AC 46 A MC07B0220-503-4-00 3 30 kw / 40 HP AC 60 A MC07B0300-503-4-00 37 kw / 50 HP AC 73 A MC07B0370-503-4-00 45 kw / 60 HP AC 89 A MC07B0450-503-4-00 4 55 kw / 74 HP AC 105 A MC07B0550-503-4-00 75 kw / 100 HP AC 130 A MC07B0750-503-4-00 5 Size 0XS 0S 0L 0XS 0S 0XS 0S Revision MOVITRAC B 3

3 kva i P f n Hz Technical Data Braking resistors, BW Series 3 Technical Data 3.1 Braking resistors, BW Series 3.1.1 General information UL and cul approval Type BW.. braking resistors are UL and cul approved in conjunction with MOVITRAC frequency inverters. SEW-EURODRIVE will provide a certificate on request. The BW..-T and BW..-P braking resistors have cruus approval independent of the MOVITRAC inverters. 3.1.2 PTC braking resistors Observe the following points for the PTC braking resistors: 4-quadrant operation is recommended for applications in which the level of regenerative energy is low. The resistor protects itself (reversible) against regenerative overload by changing abruptly to high resistance and no longer consuming any more energy. The inverter then switches off and signals a brake chopper fault (fault code 04). Assignment of the PTC braking resistors: Braking resistor type BW1 BW2 BW3 BW4 Part number 822 897 3 823 136 2 823 598 8 823 599 6 Ambient temperature ϑ A 25 C +60 C ( 13 F 140 F) For MOVITRAC B 0003 0040 (400/500 V) 0003 0022 (230 V) 3.2 Mounting PTC braking resistors FKB10B For sizes 0XS, 0S, 0L 65 (2.6) 125 (4.92) Type Part number Size 230 V 400 V FKB10B 18 216 218 0XS, 0S, 0L BW3 BW1 4 Revision MOVITRAC B

Parameters Explanation of the parameters kva i P f n Hz 4 4 Parameters 4.1 Explanation of the parameters No. FBG Name Description 5.. Monitoring functions 56. Current limit Ex e motor: The parameter group P56. Current Limitation Ex e Motor contains display and setting values that are specific to the "Current Limitation in the Ex e Motor on Inverter" function. The factory setting is indicated by bold. The factory settings apply for the delivery status. Frequencies lower than frequency A and higher than the rated motor frequency are permanently illegal. The following rules always apply: frequency A < frequency B < frequency C < rated motor frequency current limitation A < current limitation B < current limitation C 560 Current limit Ex-e motor Setting range: On / Off ON: Current limitation for Ex e motors active. On startup, the current limitation for Ex e motors is automatically activated for motors selected and approved for the operation in potentially explosive areas. 561 Frequency A Setting range: 0 5 60 Hz Value for minimum operating frequency f A. The operation time with frequency A is 60 seconds, regardless of the current value. After this time, the inverter switches with "F110 Ex e protection" error message. 562 Current limit A Setting range: 0 50 150 % Current limitation that is permitted with operating frequency f A. There is a linear gradient between current limitation A and current limitation B. 563 AUTO Frequency B Setting range: 0 10 104 Hz Value for operating frequency f B. 564 Current limit B Setting range: 0 80 150 % Current limitation that is permitted with operating frequency f B. There is a linear gradient between current limitation B and current limitation C. 565 Frequency C Setting range: 0 25 104 Hz Value for operating frequency f C. 566 Current limit C Setting range: 0 100 150 % Current limitation that is permitted between operating frequency f C and rated motor frequency. The rated motor frequency is 50 Hz for star connection and 87 Hz for delta connection. After startup with an Ex e motor, the current limit C is approximately equal to the rated motor frequency I N. Revision MOVITRAC B 5

4 kva i P f n Hz Parameters Explanation of the parameters No. FBG Name Description 7.. Control functions 75. Master/slave function The master-slave function allows for implementing automatic functions such as speed synchronization. The RS- 485 interface or the system bus interface can be used as the communication link. P100 "Setpoint source" must then be set to master SBus or master RS485. The process output data PO1 PO3 (P870, P871, P872) are automatically set by the firmware. A programmable terminal function, "Slave free run." (P60_/P61_) makes it possible to separate the slave from the master setpoint of the master and switch it to a local control mode (like control source bipolar/fixed setpoint). For the slave, the process data P87x are automatically assigned as follows: PO1 = Control word 1 PA2 = Speed PO3 = IPOS PO data PI1 = Status word 1 PI2 = Speed PI3: IPOS PI data Master P750 Slave setpoint RS-485 / SBus Slave free-running Slave P751 Scaling slave setpoint P100 setpoint source P101 control source 0 1 0 1 = Master SBus = Master RS-485 = Bipolar fixed setpoint / fixed setpoint If P100 = Master, Enable via master* ) = Input terminals P811 RS-485 Group address or P882 SBus Group address must be set to the same value in master and slave. For master/slave operation via RS-485 interface, set P811 RS-485 Group address to a value greater than 100. For operation via system bus (e.g. master/slave operation), the bus terminating resistors at the start and end of the system bus must be activated. Setpoint specified via RS-485: If the master specifies the setpoint for the slaves via RS-485, MOVITRAC B takes over the master function in the RS-485 interface after the parameter 750 has been set to "RS-485 speed". The communication with MotionStudio is aborted after MOVITRAC B is activated as RS-485 master, since it has only one RS-485 interface. The connection to MotionStudio can be re-established by setting the parameter 570 back to the value "master/ slave off" using a FBG11B keypad. After that, MotionStudio can be used again as master at the RS-485 interface. MotionStudio can also be connected via a UOH/DFxxxx fieldbus gateway. In this combination, MOVITRAC B can function as a master on the RS-485 interface. 6 Revision MOVITRAC B

Configuration Configuring the motors for explosion-proof areas 5 5 Configuration 5.1 Configuring the motors for explosion-proof areas You can only use the following explosion-proof AC motors from SEW-EURODRIVE with MOVITRAC B: edt71d4, edt80k4, edt80n4, edt90s4, edt90l4, edv100m4, edv100l4, edv112m4, edv132s4, edv132m4, edv132ml4, edv160m4, edv160l4, edv180m4, edv180l4 The motors listed above are started up via the selection of motor types in MOVITOOLS MotionStudio. MOVITRAC B function: A certified safety function is used in conjunction with temperature sensors in the motor to provide for a safe operation in potentially explosive areas. The current limitation function in MOVITRAC B prevents the activation of the safety device, i.e. the motor is protected against impermissible overheating ( following figure). Current limitation 1.5 I N (motor) I 1 I N (motor) Iü B I 2 C Iü Depending on motor type A Permitted continuous current range f A f B f C f base f/hz After motor startup, current limitation I 1 is active. Current limitation I 2 determines the current permanently permitted (shaded area) On startup of approved Ex e motors, the current limitation function can be activated via the P560 Current limitation Ex e motor Revision MOVITRAC B 7

5 Configuration Configuring the motors for explosion-proof areas The characteristic curve of the current limitation is defined by operating points A, B and C. The following parameters are set during startup: Characteristic curve of the current limit Parameter Point A Point B Point C Frequency [Hz] P561 P563 P565 Current limitation in % of I N P562 P564 P566 Operation above the permitted permanent current range is permitted for 60 seconds. To prevent a sudden reduction of the current limitation and thus torque shocks, after about 50 seconds, the current is reduced to the permitted value along a ramp within 10 seconds. The current can again exceed the permitted range after a recovery time of 10 minutes. Operation below 5 Hz is permitted for 60 seconds. After this time has elapsed, the unit switches off with error F110 Ex e protection and performs a stop with inhibit as an error response. The binary inputs P62_ can be parameterized to "Ex e current limitation active". Precondition for the binary output being set ("1" signal): Current limit 1 exceeded Recovery time not elapsed yet Operation < 5 Hz longer than 60 seconds The current-time monitoring is reset by an error reset. The current-time monitoring is active both for supply system operation and DC 24 V backup mode. If the supply voltage is switched off without DC 24 V backup mode, the monitoring function is reset completely. 8 Revision MOVITRAC B

Installation Installation of optional power components 6 6 Installation 6.1 Installation of optional power components 6.1.1 Installation of HD output choke Installation of output choke HD100 / HD101 Use the supplied screws to mount the HD100 / HD101 output choke together with the MOVITRAC B frequency inverter onto the conductive mounting surface in the control cabinet. The connections U / V / W are labeled U / V / W and have to be connected accordingly. Revision MOVITRAC B 9

7 I 0 Startup Startup of motors for explosion-proof areas 7 Startup 7.1 Startup of motors for explosion-proof areas Use the MOVITOOLS MotionStudio software for startup. During startup, parameters P560 P566 are automatically activated for SEW motors selected and approved for Ex e operation. After startup, P560 can only be activated if a motor approved for Ex e operation has been started up beforehand. You can document the startup parameters and values with MOVITOOLS MotionStudio. They are displayed in the "ATEX information" window. 10 Revision MOVITRAC B

SEW-EURODRIVE Driving the world

Drive Technology \ Drive Automation \ System Integration \ Services How we re driving the world With people who think fast and develop the future with you. With a worldwide service network that is always close at hand. With drives and controls that automatically improve your productivity. With comprehensive knowledge in virtually every branch of industry today. With uncompromising quality that reduces the cost and complexity of daily operations. SEW-EURODRIVE Driving the world With a global presence that offers responsive and reliable solutions. Anywhere. With innovative technology that solves tomorrow s problems today. With online information and software updates, via the Internet, available around the clock. SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D-76642 Bruchsal / Germany Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com