Standard AC Motor Type MSSW Series This is unit products which is combined a compact speed control pack and W-9W speed control motor. The gearhead shown in the photograph is sold separately. Product Number Code MSS - Y E MSSW Series Output Power :W Motor Frame Size : mm sq. : mm sq. : mm sq. : 9mm sq. Shaft Type : Round shaft : GN pinion shaft (for use with GN type gearhead) : GU pinion shaft (for use with GU type gearhead) Type : Motor : Motor Provided Capacitor E: Single-Phase V/V Voltage Y: Single-Phase V/V Note: The "E" at the end of the model number indicate that the unit includes a capacitor. This letter is not listed on the motor nameplate. Refer to page A- for the Product Number Code of the Gearheads. c Features Speed control range 9r/min (Hz), 9r/min (Hz) Speed control motor unit Directly connected to the programming controller, the speed control pack is used for managing the motor speed. It is not necessary for controlling through the power relay, realizing less wiring and reduced maintenance. Multi-functions In addition to the speed controlling function, a variety of controlling functions are featured in the attempt to responding to different driving conditions. Those functions include slow start/slow down function, immediate stopping function, changing driving direction function. Easy wiring The motor and the control pack can be connected easily through the connector. Built-in overheat protection device contain a built-in overheat protection device. W:Impedance protected W9W:Built-in thermal protector. Wide range of variation From the frame size of mm sq. W type to 9mm sq. 9W type, a variety of products are lined up in the series. Safety Standards and CE Marking Products Standards UL Certification Standards Body File No. UL9(W type) E99(W type) UL(W~9W type) UL CSA C. No. Motor CSA C. No. EN9 VDE EN- EN- IEC- UL Control CSA C. No. Pack EN9 EN Note:Recognized name and certified name are motor name and speed control pack name. For installation conditions for EN/IEC standards, refer to page D-. W 9W type. Installation Conditions Overvoltage category Pollution degree Classequipment E9(W 9W type) 99ÜG (W type) ÜG (W9W type) Conform to EN/IEC Standards (EN/IEC certifications are scheduled.) UL E99 Conform to EN Standards CE Marking Low Voltage Directive Low Voltage Directive Standard AC Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories Brushless Motor and Driver AC Speed Control AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Standard AC Product Lines Output Power (W) 9 Pinion shaft type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Round shaft type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Output Power (W) 9 Pinion shaft type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Round shaft type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Brushless Motor and Driver AC Speed Control Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Specifications Continuous Rating Pinion Shaft Type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Round Shaft Type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Maximum Output Power W 9 Voltage Frequency V Hz Variable Speed Range r / min 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 r / min mnm These motors are impedance protected. These motors contain a built-in thermal protector.when a motor overheats for any reason,the thermal protector is opened and the motor stops.when the motor temperature drops,the thermal protector closes and the motor restarts.be sure to turn the motor off before inspecting. The speed ranges shown are under no load condition. The "E" at the end of the model number indicate that the unit includes a capacitor. This letter is not listed on the motor nameplate. -Minutes Rating Pinion Shaft Type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Round Shaft Type MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE Maximum Output Power W 9 Voltage Frequency V Hz Variable Speed Range r / min 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9r / min mnm 9 r / min mnm 9r / min mnm 9 9 9 Starting Torque mnm 9 9 9 Current A.............9.9.9... Power Consumption W 9 9 Capacitor These motors are impedance protected. These motors contain a built-in thermal protector.when a motor overheats for any reason,the thermal protector is opened and the motor stops.when the motor temperature drops,the thermal protector closes and the motor restarts.be sure to turn the motor off before inspecting. The speed ranges shown are under no load condition. The permissible torque and the starting torque of the reversible motors are shown in terms without the brake applied. Please keep in mind that you should select a suitable motor with enough torque, when designing the equipment. The "E" at the end of the model number indicate that the unit includes a capacitor. This letter is not listed on the motor nameplate. 9 9 9 Starting Torque mnm Current A....9..9............ Power Consumption W 9 99 9 99 F......... Capacitor F......... Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
General Specifications of After rated motor operation under normal ambient temperature and humidity. Item Specifications Insulation Resistance M Ω or more when V DC is applied between the windings and the frame. Dielectric Strength Sufficient to withstand.kv at Hz and Hz applied between the windings and the frame. C or less measured by the resistance change method after rated motor operation with Temperature Rise connecting a gearhead or equivalent heat radiation plate. Insulation Class Class B ( C) MSS Type have impedance protection. All others have built-in thermal protector (Automatic Overheat Protection return type) Operating temperature, open: C C close: C C Ambient Temperature Range C C Ambient Humidity % maximum (noncondensing) MSS,MSS,MSS,MSS Type:IP Degree of protection MSS,MSS9 Type:IP Equivalent head radiation plate sizes (material : aluminum) Unit=mm Output W D t power MSS Type MSS Type MSS Type MSS Type MSS Type MSS9 Type W W W W W 9W Standard AC General Specifications of Speed Control Packs Voltage Function Control Input List of Motor and Speed Control Pack Combinations numbers for motor speed control pack combinations are shown below. Output Power (W) 9 Item Speed Range Insulation Resistance Dielectric Strength Ambient Temperature Range Degree of protection Ambient Humidity Unit MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE MSS9-YE Specifications Single-Phase VHz,Single-Phase V% /Hz Speed Control, /C Instantaneous Direction Change, Instantaneous Stop, Slow Start/Slow down Voltage : DCV.Amin. Signal Input : /C//SPEED SET Photocoupler Input Contact capacity : DCV ma Speed controller input signal, External speed potentiometer (kω) or DC power supply (V DC) Hz9r/min Hz9r/min MΩ or more when V DC is applied between the PE terminal and the power supply input terminals, the signal input terminals and the power supply input terminals. Sufficient to withstand.kv(kv)ac at Hz and Hz applied between the PE terminal and the power supply input terminals (the signal input terminals and the power input terminals) for minute. C IP % maximum (noncondensing) Motor USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM9-W USM9-W Speed Control Pack MSP-Y Junction Cable CCSSB CCSS Output Power (W) 9 Unit MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE MSS9-YE Motor USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM-W USM9-W USM9-W Speed Control Pack MSP-Y Junction Cable CCSSB CCSS Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads Brushless Motor and Driver AC Speed Control FPW Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Standard AC Torque-Speed Characteristics MSS-YE MSS-YE Torque[mNm] when Gearhead is Attached V Hz V Hz V Hz /VHzSafe-Operation Line MSS-YE MSS-YE Torque[mNm] when Gearhead is Attached V Hz V Hz V Hz /V,Hz Safe-Operation Line V,HzSafe-Operation Line V,Hz Safe-Operation Line Brushless Motor and Driver AC Speed Control Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW MSS-YE MSS-YE Torque[Nm]..... MSS-YE MSS-YE Torque[Nm] when Gearhead is Attached Speed[r/min] V,HzSafe-Operation Line /VHzSafe-Operation Line..... when Gearhead is Attached Speed[r/min] V,Hz Safe-Operation Line V,Hz Safe-Operation Line Speed[r/min] V Hz V Hz V Hz V Hz V Hz V Hz V,Hz Safe-Operation Line MSS-YE MSS-YE Torque[Nm]..... MSS9-YE MSS9-YE Torque[Nm] when Gearhead is Attached Speed[r/min] V,Hz Safe-Operation Line V,Hz Safe-Operation Line...... when Gearhead is Attached Speed[r/min] V,HzSafe-Operation Line V,HzSafe-Operation Line Speed[r/min] V Hz V Hz V Hz V Hz V Hz V Hz /VHzSafe-Operation Line Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
MSS-YE MSS-YE when Gearhead is Attached V Hz V Hz V Hz MSS-YE MSS-YE when Gearhead is Attached V Hz V Hz V Hz /VHzSafe-Operation Line Standard AC Torque[mNm] Torque[mNm] V,Hz Safe-Operation Line MSS-YE MSS-YE Torque[Nm].... MSS-YE MSS-YE Torque[Nm] when Gearhead is Attached Speed[r/min] /VHzSafe-Operation Line V,Hz Safe-Operation Line..... when Gearhead is Attached Speed[r/min] V,Hz Safe-Operation Line V,Hz Safe-Operation Line Speed[r/min] V Hz V Hz V Hz V Hz V Hz V Hz V,HzSafe-Operation Line MSS-YE MSS-YE Torque[Nm]...... MSS9-YE MSS9-YE Torque[Nm] when Gearhead is Attached Speed[r/min] V,Hz Safe-Operation Line V,Hz Safe-Operation Line....... Speed[r/min] when Gearhead is Attached V,Hz Safe-Operation Line V Hz V Hz V Hz V,HzSafe-Operation Line Speed[r/min] V Hz V Hz V Hz /VHzSafe-Operation Line Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads Brushless Motor and Driver AC Speed Control FPW Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Standard AC Speed Range when Gearheads is Attached.. 9. Hz 9 Hz...... 9.9 Unitr/min. 9... When Gearhead is Attached The permissible torque with decimal gearhead with a gear ratio of is; GNKNm GNKNm GNKNm (for //Nm) GNKNm GUKBNm Right-Angle gearheads may be connected to MSS, MSS, MSS and MSS9 types. Refer to page A- for further detail. Single-Phase V Hz.. 9. 9 UnitN m Brushless Motor and Driver AC Speed Control Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW MSS-YE /GNK MSS-YE /GNK MSS-YE /GNK MSS-YE /GNK MSS-YE /GUKB MSS9-YE /GUKB Single-Phase V Hz MSS-YE /GNK MSS-YE /GNK MSS-YE /GNK MSS-YE /GNK MSS-YE /GUKB MSS9-YE /GUKB r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min r/min 9r/min...9..9......9....................9.9...........9.9......9.................9.....9.....9.......9.......9.9.....9.9...........9.......9.9........9 9...9.........9.................9.........9..9...9.9..........9.....9......9.. 9........... 9........9......9.9............... 9........ 9.....................9....................9... 9.9.. 9 9.9.....9......9..9 9.9...... 9.....9..9.. UnitN m Accessories Gearheads and decimal gearheads are sold separately. Enter the gear ratio in the box () within the model number. A colored indicates gear shaft rotation in the same direction as the motor shaft; a white background indicates rotation in the opposite direction. Values for permissible torque are calculated by taking permissible torque at high speed (r/min) and low speed (9r/min) and multiplying by gear ratio and gearhead efficiency. AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Operation of MSS.W Series Names and Functions of Speed Control Pack Display Color Function Examples of Connections Speed Control Pack SPEED CONTROLLER MSP-Y VIN POWER C SPEED C SET SET VR NC SPEED SS SD MB ON CAPACITOR V V V SPEED OUT L N FG LED POWER green Power indicator C SET green green green green Signal input indicator Signal input indicator Speed setting method indicator Signal input indicator Internal speed potentiometer Capacitor connection terminals Power supply input terminals Frame ground terminal Conditions under which light goes on When both the AC power and the DC power are on When a signal is input to When a signal is input to C When a signal is input to SPEED SET When a signal is input to Slow start/slow down time potentiometers Do not use this switch. Leave it at the factory setting ON. External DC power supply Junction cable included DCV.A min. Clockwise rotation inputh rotation, LStop Countererclockwise rotation inputhc rotation, Lstop Speed controller switch inputhinternal, Lexternal Brake release inputhfree stop, Lbrake stop External Speed Potentiometer K /W provided Capacitor included Protective EarthP.E. SPEED CONTROLLER MSP-Y VIN POWER C SPEED C SET SET VR NC SPEED SPEED OUT Motor Power Supply Connection single-phase V% Hz single-phase V% /Hz Note: In the connection diagram, the bold lines indicate the power lines, and the other lines indicate signal lines. Large current run through the bold lines indicated in the connecting diagrams. Use wires with cross sectional area of AWG(.mm ) or larger for these lines. Use one speed control pack per motor. Replace the plastic cover over the power cord terminal block. When motors are running, a voltage of twice the motor power supply voltage is applied across the terminals of the capacitor. The terminals must therefore be insulated to ensure safety. SS SD MB ON CN CAPACITOR V L V V N FG Speed Control Pack Front Panel Signal power supply terminals Connect the DCV power supply Signal input/output terminals C SPEED SET VR NC SPEED OUT Clockwise rotation input Counterclockwise rotation input Speed controller switch input Brake release input Speed control input Speed out (Rategenerator Signal) Connector for motor Protective Earth (Screw size : M) Note : Use lead wires with have the following specifications for signal lines. Thickness :.mm.mm (AWG) Length of strip : mmmm VIN Control by Small Capacity Relays or Switches Switch capacitydcv ma Speed control pack Signal power supply terminals Signal input/output terminals C SPEED SET Control by Programmable Controller (Transistor output type) Speed Control Pack VIN Common to C SPEED SET DCV.A min. Stop Stop C External Internal Brake Programmable Controller AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr V GND V Standard AC Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories A-9 Brushless Motor and Driver AC Speed Control
Brushless Motor and Driver AC Speed Control Standard AC Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories Signal Input Timing Chart Control of operation, stopping, switching direction of rotation and instantaneous stopping can all be performed with clockwise rotation input, brake release input, and counterclockwise rotation input signals. When or C input is turned on (switch to high), the motor accelerates to the selected speed for the length of time set on the acceleration time potentiometer. If and C are input simultaneously, has priority. Thus, if C input is left on, direction can be changed instantaneously by turning the input on and off (only reversible motor). However, under certain power supply voltages or load conditions, change of direction may be delayed. Switching brake release input OFF and then switching both clockwise rotation input and counterclockwise rotation input OFF makes the dynamic brake go into operation automatically and stops the motor instantaneously. During an instantaneous stop, the dynamic brake sends a braking current for.-. seconds. Switching brake release input ON and then switching both clockwise rotation input and counterclockwise rotation input OFF makes the motor come to a free stop. Internal Equivalent Circuit Diagram Clockwise rotation input Counterclockwise rotation input C Speed controller switch input SPEED SET Brake release input Signal power supply input VIN Braking Current Signal power supply input switch (panel surface) Power supply ON OFF H L H L H L High speed Low speed Brake Brake Brake Operation Operation Operation C C Operation Brake Operation There is a.-. second flow of maximum halfwave rectified current when the motor is instantaneously stopped. When attaching a circuit protector or other safeguard to a line carrying this type of braking current, refer to the table to select a device with the appropriate capacity. Type MSSType MSSType MSSType MSSType MSSType MSS9Type Repeated motor operation and braking causes the motor's temperature to rise and limits the continuous usage time of both the motor and control pack. Maximum motor output WW W9W.k.k Braking Current (Peak Value) [A].... 9...k.k Clockwise rotation input, counterclockwise rotation input, speed controller switch input, and brake release input are performed by photocoupler input. The internal equivalent circuits are as shown in this diagram. Operation and braking cycle seconds or longer ( second of operation and second stopped) seconds or longer ( second of operation and second stopped) AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Methods of Speed Setting and Their Connection The following three methods of setting speed can be used with MSSW units. Internal speed potentiometer The internal speed potentiometer can be selected by turning on (switch to high) input to the SPEED SET terminal. The speed is set to r/min when the product is shipped. Rotate clockwise to start the motor rotating. Internal speed potentiometer Internal speed potentiometer scale-rotation speed characteristicsrepresentative Values Motor rotation speedr/min Hz Hz Standard AC External speed potentiometer(provided) The external potentiometer can be selected by turning off (switch to low) input to the SPEED SET terminal. The external speed potentiometer is connected as shown in the following diagram below using the lead wire. When connecting, turn the external speed potentiometer's knob counterclockwise and set the speed to r/min. In this case, high-speed operation can be set when turning the external potentiometer's knob clockwise. Speed control pack Signal input/output terminals VR External speed potentiometerk /W External DC voltage The external DC voltage can be selected by turning off (switch to low) input to the SPEED SET terminal. To connect an external DC voltage, connect the plus wire to the terminal, the minus wire to the terminal. High speed operation can be set when DC voltage of the external DC supply is elevated. Speed control pack Signal input/output terminals VR k /W Note : Ensure that there are no errors in positive and negative polarity. This could result in faulty operation and damage the speed control pack. DC Power Supply DCV ma min. with a linear resistance vs. angle curve High Speed Motor rotation speedr/min Motor rotation speedr/min Internal speed potentiometer scale External speed potentiometer resistance-rotation speed characteristicsrepresentative values DC voltage - rotation speed characteristics Representative Values Hz Hz Speed potentiometer resistancek Hz Hz DC voltagev Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories Brushless Motor and Driver AC Speed Control AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Standard AC Slow start / Slow down Equipment and work pieces are subject to large acceleration/deceleration force at start, stop, and when changing speeds. When you want to accelerate/decelerate without any accompanying shock, the acceleration/deceleration time can be extended using the slow start/slow down function. The slow start/slow down time can be set using the slow start/slow down time potentiometers built into the control pack. However, when the load inertia is large, the slow down time may be longer than the slow down time set. Slow start The slow start function is activated at start up and after switching to high speed. To not use slow start, set the slow start time potentiometer to. Slow start timesec/r/min The illustration below shows for induction motor type. Hz, V, with no load Slow down timesec/r/min Hz, V, with no load Brake Slow down The slow down function is activated after switching from high speed to low speed. To not use slow down, set the slow down time potentiometer to. Slow start time controller scale (Representative Values) Slow down time controller scale (Representative Values) Brushless Motor and Driver AC Speed Control FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Dimensions (Scale /, Unit=mm) MSS-YE (Pinion Shaft) MSS-YE Motor USM-W USM-W Mass.kg Gearhead GNK (Sold separately) Mass.kg mm Leads W/Connector.h Connector HousingAMP Asterisk () indicates dimensions of GNKK, the figure in parenthesis indicates dimensions of GNKK. MSS-YEPinion Shaft MSS-YE Gearhead Motor USM-W USM-W GNK (Sold separately) Mass.kg Mass.kg 9 mm Leads W/Connector.h.. Connector HousingAMP.. MSS-YE (Round Shaft) MSS-YE Motor USM-W Mass.kg USM-W.h.h.. MSS-YERound Shaft MSS-YE Motor USM-W Mass.kg USM-W.h.h.. Accessories Asterisk () indicates dimensions of GNKK, the figure in parenthesis indicates dimensions of GNKK. AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
MSS-YEPinion Shaft MSS-YE Gearhead Motor USM-W USM-W GNK (Sold separately) Mass.kg Mass.kg 9.. (h). 9. MSS-YERound Shaft MSS-YE Motor USM-W Mass.kg USM-W.(h).(h). 9. Standard AC mm Leads W/Connector MSS-YEPinion Shaft MSS-YE Gearhead Motor USM-W USM-W GNK (Sold separately) Mass.kg Mass.kg 9 9.. mm Leads W/Connector Asterisk () indicates dimensions of GNKK, the figure in parenthesis indicates dimensions of GNKK. Key and Key Slot (Scale /) (Included with the gearheads) GNK,GNK,GNK 9. Connector HousingAMP Asterisk () indicates dimensions of GNKK, the figure in parenthesis indicates dimensions of GNKK..(h) Connector HousingAMP. MSS-YEPinion Shaft MSS-YE Gearhead Motor USM-W USM-W GUKB (Sold separately) Mass.kg Mass.kg. Cabtyre Cable. mm Connector HousingAMP... (h).... -. 9. MSS-YERound Shaft MSS-YE Motor USM-W Mass.kg USM-W 9.(h).(h) 9 Key and Key Slot (Scale /) (Included with the gearheads) GUKB AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr....... Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories A- Brushless Motor and Driver AC Speed Control
Standard AC MSS-YERound Shaft MSS-YE Motor USM-W USM-W Mass.kg. (h). (h) 9. -. 9 Brushless Motor and Driver AC Speed Control Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW MSS9-YEPinion Shaft MSS9-YE Gearhead Motor USM9-W USM9-W GUKB (Sold separately) Mass.kg Mass.kg 9. MSS9-YERound Shaft MSS9-YE Motor USM9-W USM9-W Mass.kg. (h). (h) 9 Cabtyre Cable. mm. -. 9 Connector HousingAMP.. (h) -. 9. Key and Key Slot (Scale /) (Included with the gearheads) GUKB..... Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Capacitor (Included with the motor ; Unit=mm) AMP# A.. B C B Motor MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE MSS9-YE Capacitor CHBFAUL CHBFAUL CHBFAUL CHBFAUL CHBFAUL CHBFAUL A B.. 9 C. Mass (g) No. Standard AC AMP#. A B B C R Control Pack (Scale /, Unit=mm) Control Pack: MSP-Y Mass.kg -MP. 9 9. Slit Motor MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS-YE MSS9-YE CHBFAUL CHBFAUL CHBFAUL CHBFAUL CHBFAUL CHBFAUL 9 9 9 If you need to order a capacitor without a motor, add "-C" to the capacitor model number shown. A capacitor cap is always included with a capacitor..max. -MP. -M P. Capacitor MAX.. -M A MAX. B... PITCH. C MP. Mass (g) No. Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads Brushless Motor and Driver AC Speed Control FPW Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Standard AC External speed potentiometer Included, scale/, Unit=mm Speed control pack Mounting Tab Mounting Screws (M) included Mounting Tab A set of pieces included.. Mounting Tab B set of pieces included Brake Junction cable Included, Unit=mm For W, W, W, W types For W, 9W types. Countersink... Countersink Brushless Motor and Driver AC Speed Control FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Motor Side Housing--AMP Speed control Pack Side Right-Angle Gearhead (Sold separately) Housing-RMOLEX The right-angle gearhead provides an output shaft at a right angle to the motor's output shaft. Refer to page A- for further detail. Accessories (Sold separately) Motor Mounting Brackets Optional die-cast aluminum mounting brackets are available. They can be used to install motors without gearheads. Refer to page A- for further detail. Motor Side Housing--AMP DIN Rail Mounting Plate Speed control Pack Side Housing-RMOLEX This mounting plate is convenient for installing the speed control pack and DIN rails with ease. Refer to page A- for further detail. : PADP Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-
Extension Cable For MSS Type MSS Type MSS Type MSS Type CCSS CCSS CCSS CCSS Lm For MSS Type MSS9 Type CCSS CCSS CCSS CCSS Lm Standard AC - -AMP - -AMP Brushless Motor and Driver AC Speed Control Brake FBL AXU AXH HBL MSS W ES US Gearheads Linear Heads FPW Accessories AUDIN -, avenue de la malle - Saint Brice Courcelles - Tel :... - Fax :... - Web : http: www.audin.fr - Email : info@audin.fr A-