FLEX-PRO TM PERISTALTIC PUMPS Applications Chemical Wastewater treatment Chlorination Pulp & Paper Slurries Printing inks Oil based fluids Gaseous fluids Shear sensitive fluids Caustics Chemical Slurries Food and Beverage Feed rate Peristaltic pump design does not have valves that can clog requiring maintenance. Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapour lock or lose prime. Output volume is not effected by changes in back pressure. Two pump tubes supplied with each pump. No extra tubing required. Inputs include: 4-20mA, 0-10VDC, and Pulse inputs for external speed control and 0-30 VDC contact closure remote start/stop. Operator friendly digital touch pad with menu driven software. VGA Graphic backlit LCD displays motor speed, input signal values, service and alarm status. Outputs include: Scalable 4-20mA and pulse, One 10 amp relay and three 30 VDC contact closures assignable to monitor TFD, FVS, motor on, operating mode error. Two CNC machined squeeze rollers and two alignment rollers for optimum squeeze, unparalleled accuracy, and tube life. Heavy duty rotor - single piece rotor design means no flexing and increased accuracy Pump can handle same maximum PSI in either direction. Output rates to: 33.3 GPH (12 LPH) @ 125 PSI (8. Bar). No maintenance, brushless variable speed motor. Specially engineered tubing for long life at high pressures. Motor reverse feature to increase tube life. Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting chemical in the pump head. Part Numbers GPH LPH ML/Min Speed RPM tube type 115V AC 230V AC 220V AC.01-1.0.03-3.9.3-3.1 2 Norprene A3V14-SND A3V15-SND A3V1-SND.02-2.1.07-7.8 1.32-132.5 125 Norprene A3V24-SND A3V25-SND A3V2-SND.04-4.0.15-15.0 2.52-252.4 2 Norprene A3V14-SNF A3V15-SNF A3V1-SNF.07-7.9.30-30.0 4.98-498.4 125 Norprene A3V24-SNF A3V25-SNF A3V2-SNF.09-9.0.34-34.1 5.7-57.8 2 Norprene A3V14-SNH A3V15-SNH A3V1-SNH.12-12.7.48-48.0 8.01-801.2 2 Norprene A3V14-SNJ A3V15-SNJ A3V1-SNJ.1-1..3-3.0 10.47-1047.3 125 Norprene A3V24-SND A3V25-SND A3V2-SND.17-17.4. -.0 10.97-1097.8 125 Norprene A3V24-SNH A3V25-SNH A3V2-SNH.25-25.3.9-9.0 15.9-159.2 125 Norprene A3V24-SNJ A3V25-SNJ A3V2-SNJ.33-33.3 1.2-12.0 21.00-2100.9 125 Norprene A3V24-SNK A3V25-SNK A3V2-SNK.02-2.4.09-9.0 1.51-151.41 2 Tygothane A3V14-SGE A3V15-SGE A3V1-SGE.04-4..17-17.4 2.90-290.2 125 Tygothane A3V24-SGE A3V25-SGE A3V2-SGE.05-5.0.18-18.9 3.15-315.45 2 Tygothane A3V14-SGG A3V15-SGG A3V1-SGG.10-10.1.38-38.4.37-37.2 125 Tygothane A3V24-SGG A3V25-SGG A3V2-SGG.12-12.0.45-45. 7.57-757.1 2 Tygothane A3V14-SGH A3V15-SGH A3V1-SGH.24-24.9.94-94.2 15.70-1570.9 125 Tygothane A3V24-SGH A3V25-SGH A3V2-SGH -27
A-100N PERISTALTIC PUMPS Applications Chemical Wastewater treatment Chlorination and Caustics Pulp & Paper Slurries Oil based fluids Gaseous fluids Shear sensitive fluids Chemical Slurries Food and Beverage Peristaltic pump design does not have valves that can clog requiring maintenance. Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapour lock or lose prime. Outputs to 250 ml/min (95.1 GPD). Output pressures to 100 PSI. Output volume is not effected by changes in back pressure. Patented pump tube design installs easily and stays centered on the rollers without manual adjustment. Two pump tubes supplied with each pump. No extra tubing required. Easy to use dial knob speed adjustment. Built-in Tube Failure Detection system (TFD). Senses chemical in the pump head, shuts off the pump and activates an NPN open collector output. Compatible with Blue-White s output flow verification sensor system. Durable housing of chemical resistant Valox (PBT) thermoplastic. Selection Process 1. Select imum Motor RPM (See Below) 0 = 14 RPM 1 = 30 RPM 2 = 45 RPM 3 = 0 RPM 2. Select Power Supply 0 = 115V0Hz 1 = 220V50Hz 2 = 230V0Hz 8 = 240V50Hz 3. Select Pump Tube Size and Material (see below) 1 = 1/4 OD Tygothane 2 = 3/8 OD Tygothane 3 = 7/1 OD Tygothane 4 = 1/4 OD Norprene 5 = 5/1 OD Viton = 3/8 OD Norprene 7 = 7/1 OD Norprene 4. Select Tubing Connection Type T = Compression tube nuts Q = Push-on quick connect 5. Select Miscellaneous Options if required. working pressure: 100 psig (.9 bar). fluid temperature:130 F (54 C). ambient temperature: 14 to 110 F/-10 to 43 C Output adjustment range: 5-100% in 1% increments imum viscosity: 5,000 Centipoise imum suction lift: 30 ft. Water 0 psig imum Solids: 50% by volume Enclosure: NEMA type 2, (IP21) Voltage (amp draw): 115VAC/0Hz, 1ph (.513 amp max) 230VAC/0Hz, 1ph (.53 amp max) 220VAC/50Hz, 1ph (.0 amp max) 240VAC/50Hz, 1ph (.585 amp max) Power Cord Plug Type: 115V0Hz = NEMA 5/15 (USA) 230V0Hz = NEMA /15 (USA) 220V50Hz = CEE 7/VII (EUROPE) 240V50Hz = CEE 7/VII (U.K) Approximate shipping wt: 12 lb. (5.4 kg) 14 RPM Model 30 RPM Model 45 RPM Model 0 RPM Model Tubing Material GPH GPD psi GPH GPD psi GPH GPD psi GPH GPD psi 1 = 1/4 OD Tygothane 0.24 5.7 5 0.55 13.3 5 0.8 20.5 5 1.0 25.5 5 2 = 3/8 OD Tygothane 0.51 12.2 5 1.19 28.5 5 1.82 43.7 5 2.22 53.2 5 3 = 7/1 OD Tygothane 1.1 27.8 50 2.74 5.8 50 4.14 99.2 50 5.17 124 50 4 = 1/4 OD Norprene 0.1 2.3 100 0.21 4.9 100 0.1 8 100 0.4 9.5 75 5 = 5/1 OD Viton 0.17 4.2 25 0.41 9.9 25 0.2 14.8 25 0.7 18.3 25 = 3/8 OD Norprene 0.29.8 100 0.7 1 100 1 24 100 1.25 30 75 7 = 7/1 OD Norprene 0.9 21.7 50 2.19 52.5 50 3.17 7.1 50 3.9 95.1 50-28
A-100 FLEXFLO PERISTALTIC PUMPS Economical and versatile. OEM design modifications. Compact housing. Fixed output rate depending on the selected RPM. imum feed rate: 112 GPD imum PSI: 25 imum fluid temperature: 130 F imum viscosity: 500 Centipoise imum suction lift: 10 ft. water at 0 PSI Turn down ratio: non adjustable Power Requirements: Standard: 115V / 0Hz Optional: 230V / 0Hz or 24V / 0Hz Amperage draw: 115V / 0Hz, starting.74 / running.45 230V / 0Hz, starting.3 / running.21 24V / 0Hz, starting 3.4 / running 2.0 Dimensions: 4-3/4 H x 10 W x -1/4 D Shipping weight: 8 lbs. Part # P.S.I ML/MIN OZ/MIN G.P.H G.P.D A-114-3N 25 3.1.04 1 A-114-4 25 17.5.2 A-114-25 0 2.0.95 22 A-114-7 25 75 2.5 1.18 28 A-130-3N 25 11.3.17 4 A-130-4 25 40 1.3.3 15 A-130-25 130 4.4 2.05 49 A-130-7 25 195.5 3.08 74 A-145-3n 25 14.4.22 5 A-145-4 25 54 1.8.85 20 A-145-25 195.5 3.08 74 A-145-7 25 295 9.9 4.7 112. working pressure: 150 psig. fluid temperature: 130 F (54 C). Ambient temperature: 14 to 110 F/-10 to 43 C imum viscosity: 1,000 Centipoise imum suction lift: 10 ft. Water 0 psig Output adjustment range: 400:1 Stroke length and motor speed: 5-100% Enclosure: NEMA 3R, (IP23) Voltage (amp draw): 115VAC/0Hz 230VAC/0Hz Power Cord Plug Type: 115V0Hz = NEMA 5/15 (USA) 230V0Hz = NEMA /15 (USA) Approximate shipping wt:...12 lb. (5.4 kg) C-1100 CHEM-FEED Diaphragm Metering Pumps Chemical resistant PVDF valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat O-rings. No metal springs are used. Stroke length & speed adjustment for accurate small injections at a high rate per minute. 400:1 turndown ratio. PVDF suction (foot) valve with Viton and TFE/P O-rings, ceramic check ball and removable polypropylene filter screen. GPD LPH Strokes/MIN PSI 115V/0Hz Part # 230V/0Hz Part # 57.7 9.1 0 150 C11V344X000V00 C11V34X000V00 119.7 18.9 125 150 C11V444X000V00 C11V44X000V00 155.9 24. 125 150 C11V441X000V00 C11V41X000V00 20.8 41.1 250 100 C11V544X000V00 C11V54X000V00 30 5.8 250 25 C11V543X000V00 C11V53X000V00-29
C-1500N CHEM-FEED DIAPHRAGM METERING PUMPS Selection Process 1. imum Motor RPM 0 = 14 RPM 3 = 0 RPM 1 = 30 RPM 4 = 125 RPM 2 = 45 RPM 2. Select Power Supply (motor protection) 0 = 115V0Hz (IP) 4 = 115V0Hz (TP) 1 = 220V50Hz (IP) 5 = 220V50Hz (TP) 2 = 230V0Hz (IP) = 230V0Hz (TP) 3 = 24V0Hz (IP) 7 = 24V50Hz (none)* 8 = 240V50Hz (TP) IP = impedance protection, P = Thermal protection * intermittent duty only 3. Select Cam Stroke Length 1 =.125 3 =.187 2 =.055 4 =.100 4. Select Output Control & Electrical X = Standard Equipment I = Analog timer, 5 sec. Cycle - 100% duty K = Analog timer, 0 sec. Cycle - 100% duty A = Junction box replaces power cord C = On/Off switch and junction box P = Power cord and junction box R = 230V Power cord w/nema /15 plug T = 230V Power cord and on/off switch Z = Proportional feed system - JBox/Cord 5. Select Pump Head Material 0 = Injection molded Polypropylene 4 = Machined Teflon 5 = Machined Acrylic. Select Pump Head Style 0 = Large Diaphragm 4 = Large Diaphragm Carwash 2 = Small Diaphragm = Small Diaphragm Carwash 5 = Large Pressure release 7. Select Diaphragm Style 0 = Large Teflon/EP = Small Teflon / EP 1 = Large Teflon/Viton 7 = Small Teflon / EP 8. Select Elastomer Material V = Viton E = EP 9. Select Injection Fitting 0 = A-014HD (Polypropylene - ½ lb spring) 1 = C-395HD (Polypropylene - lb spring) A = A-014-T (Teflon - ½ lb spring) B = C-395-T (Teflon - lb spring) C = A-014HDK (PVDF - ½ lb spring) D = C-395HDK (PVDF - lb spring) 10. Select Footvalve 0 = C-340 (PVDF/PP) 1 = C-345 (PVDF/PP - bulkhead mount) 2 = C-340-T (Teflon) All ball bearing, permanently lubricated gear motor for smooth and quiet operation. Chemical resistant PVDF valve body and fitting, ceramic balls, Viton static seals and FEP ball seat o-rings. No metal springs are used. Stroke adjustment 5-100% permits accurate small injections at a high rate per minute. Teflon coated EP diaphragm and outdoor rated enclosure. Includes visual flow indicator on the suction line tubing. Durable housing of chemical resistant Valox (PBT) thermoplastic PVDF suction valve with Viton and TFE/P o-rings, ceramic check ball and removable PP filter screen. Includes 3/8 OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting hardware.. working pressure: 125 psig (8. bar). fluid temperature: 130 F (54 C). ambient temperature: 14 to 110 F/ -10 to 43 C imum viscosity: 1,000 Centipoise imum suction lift: 10 ft. Water 0 psig Enclosure: NEMA type 3R, (IP23) Approximate shipping wt: 8 lb. (3. kg) Output at 0 PSI GPD GPH LPM Strokes per Min PSI 115V/0Hz Part # 230V/0HZ Part # Standard models with Stroke Adjustment (20:1 turndown) 3.4 0.2 0.5 14 125 C15N002X02V00 C15N022X02V00 8.3 0.3 1.3 30 125 C15N102X02V00 C15N122X02V00 1.3 0. 2.5 0 125 C15N302X02V00 C15N322X02V00 2. 1.1 4.2 45 125 C15N202X000V00 C15N222X000V00 34.2 1.4 5.4 125 125 C15N402X02V00 C15N422X02V00 8.4 2.8 10.8 125 125 C15N402X000V00 C15N422X000V00 119.7 4.9 18.9 125 70 C15N404X000V00 C15N424X000V00 155.9.4 24. 125 20 C15N401X000V00 C15N421X000V00 228.1 9.5 3.0 125 10 C15N443X000V00 C15N43X000V00 Deluxe models with Stroke & Time Interval Adjustment (400:1 turndown) 34.2 1.4 5.4 125 125 C15N402I02V00 C15N422I02V00 8.4 2.8 10.8 125 125 C15N402I000V00 C15N422I000V00 155.9.4 24. 125 20 C15N401I000V00 C15N421I000V00-30
C-00P CHEM-FEED DIAPHRAGM PUMPS All ball bearing, permanently lubricated gear motor for smooth and quiet operation. Chemical resistant PVDF valve body and fitting, ceramic balls, Viton static seals and TFE/P ball seat O-rings, no metal springs are used. Outputs to 51 GPD and output pressures to 125 PSI. Stroke adjustment 4-100% permits accurate small injections at a high rate per min. Teflon coated EP diaphragm and durable metal epoxy coated construction. PVDF suction valve, Viton and TFE/P O-rings, ceramic check ball and PP filter screen. Includes 3/8 OD suction and discharge tubing, Injection fitting with spring-loaded check valve and all mounting GPD GPH LPH OZ/ MIN Strokes/ MIN PSI 115V/0Hz Part # 230V/0Hz Part # 24 1.0 3.8 2.7 14 125 C-14P-115VAC C-14P-230VAC 58 2.4 9.3 5.2 30 125 C-30P-115VAC C-30P-230VAC 91 3.8 14.9 8.1 45 80 C-45P-115VAC C-45P-230VAC 110 4. 17.4 9.8 0 0 C-0P-115VAC C-0P-230VAC 237 9.9 37.0 21.1 125 30 C-125P-115VAC C-125P-230VAC 389 1.2 1.4 34. 250 10 C-250P-115VAC C-250P-230VAC C3 SERIES CHEM-PRO TM DIAPHRAGM PUMPS Output, Feed Rate (dosing) up to: 42 GPH, 1,004 GPD, 158 LPH, 3,802 LPD Output pressures to 150 PSI. Operator friendly digital touch pad with easy to read Back Lit LCD display and failure alarm Oversized PVDF double ball valves. DFD, Built-in Diaphragm Failure Detection system. Senses chemical in the pump head, shuts off the pump. Priming/degassing valve built into the pumphead Suction tube (8 ft), priming tube ( ft), injection fitting, foot valve, and mounting brackets supplied with each pump. NEMA 4X and IP rated enclosure max Output at 0 psi Output at PSI Standard Model Deluxe Model Strokes 230V/0Hz part # GPH LPH PSI GPH LPH per Min 115V/0Hz Part # 230V/0Hz Part # 115V/0Hz Part # 19.7 74. 150 11.3 42. 130 C3F241XVA C3F251XVA C3V241XVA C3V251XVA 42 159 100 34.7 131.4 130 C3F242XVA C3F252XVA C3V242XVA C3V252XVA -31