QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Similar documents
F261 Series Fluid Flow Switches

UHC-202 Hardware Guide

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

Powerware Vdc Extended Battery Cabinet User s Guide.

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

RPM1600 Series Room Pressure Monitors

- Wiring Brochure Zone Manager 336

- Wiring Brochure Zone Manager 335

- Wiring Brochure Mixing Expansion Module 440

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

GE Measurement & Control

POWERWARE User s Guide VA.

A419ABG-3C Electronic Temperature Control

RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow

- Wiring Brochure tn4 Gateway 483

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

YCCS TE-6800 Series Temperature Sensors

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

02/15/01. Powerware User s Guide VA.

EZvav Digital Controls

BAPI-Stat 3 Room Sensor

02/15/ RM. Powerware. User s Guide VA.

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

SE8300 Series Installation Guide 24 Vac Low Voltage

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

T158 Series. Application. Digital, Three-Wire Floating/On-Off Thermostat/Controller General Instructions. Features

RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow

TM-9100 Series Room Command Module

User Manual Pocket Pro, Pro + ph

Operating Instructions

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

E-MCR-05 Media Converter Rack User s Guide

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

Installation & Operation Manual

V-D2425 and V-D2440 Digital Clock

MS Series MS Series MS Series

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

MF Series MF Series MF Series

Application. Features

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

- Wiring Brochure tekmarnet 4 Thermostat 545

pro user guide 940H Student Microphone 940C Microphone Charger

Installation & Operation Manual

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

SLIM LINE FUME HOOD MONITOR

Loading the Label Stock 4. Loading the Container 10. Applying the Label 13. Label Path Diagram 16. Troubleshooting and Maintenance 17

- Wiring Brochure Universal Reset Module 422

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

MA40-704X Series MA41-707X Series MA41-715X Series

OE326-23I-OR VAV/Zone Controller

Laboratory Room Controller

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Digital Room Thermostats with Touch Screen LCD

Installation Guide(s)

ELECTRONIC THERMOSTAT: T901

MAx1-720x Two Position Series MFx Floating Series MSx Proportional Series

Air Quality Solutions

MicroTech II Applied Rooftop Unit Controller

TM-11x1 Series Room Temperature Module

CU-30, CS-40, CTS-45. Operation & Setup Guide

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Tattle-Tapet. Operator s Guide. Application System Model 611. Read all Safety Information Before Using this Product

P

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

SetPoint 501 and 501s Controllers Installation and Operation Manual

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Installation Instructions RF4510-EA

MicroTech II Applied Rooftop Unit Controller

M9109 Series Electric Non-spring Return Actuators

VA-4233-AGx Series Electric Valve Actuators

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

LF Series At A Glance


M9106-AGx-2N0x Series Electric Non-spring Return Actuators

DPS/MPS/RAH/RPS/SWP Space Sensor

Feature Overview. For more information: or call toll free at

System 350 S350C Temperature Slave Stage Module

XM Series. Quick Start Guide. Technology at Work XMCom9

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

Ohaus ES Series Bench Scale

Acid Resistant AVT6000

Air Quality Solutions

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Installation instructions

Installation Instructions

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

Air Lift Performance 3S

YCCS Zone/Bypass Damper Assembly

FieldView External Charger. User Guide

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

YCCS Zone/Bypass Damper Assembly

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Transcription:

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS www.proloncontrols.com info@proloncontrols.com 17 510 rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV 1.0 PL-QCK-WSENSOR/VC2000-EN

Copyright 2018 Prolon. All rights reserved. No part of this document may be photocopied or reproduced by any means, or translated to another language without prior written consent of Prolon. All specifications are nominal and may change as design improvements are introduced. Prolon shall not be liable for damages resulting from misapplication or misuse of its products. All trademarks are the property of their respective owners.

Table of Contents Analog Sensor (PL-RS)...4 Dimensions and Wiring...4 Digital Sensor (PL-T200)...6 Dimensions and Wiring...6 Digital Sensor (PL-T500)...8. Dimensions and Wiring...8 Digital Sensor (PL-T1000)... 10. Installation... 10 Auxiliary Analog Input... 12 Operation... 12 Changing the Setpoint... 13 Schedule Override... 13 VAV Zone Controller (PL-C1000-VAV)... 14 VAV Zone Controller (PL-VC2000)... 16 Compliance... 18 Technical Specifications... 18 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 3

Analog Sensor (PL-RS) Dimensions and Wiring Schedule override 4.96 (126 mm) 1.30 (33 mm) 4 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

COM THERM COM POT Room temperature Setpoint (10K) 3.23 (82 mm) Temperature table (thermistor: 10K Type 3) Fahrenheit 41 50 59 68 77 86 95 104 Celsius 5 10 15 20 25 30 35 40 Ohms 25395 19903 15714 12493 10000 8056 6530 5324 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 5

Digital Sensor (PL-T200) Dimensions and Wiring Schedule override (hold for 3 second) 4.96 (126 mm) 1.30 (33 mm) 6 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

INT A (+) INT B (-) 24VAC COM Communication (RS485) Power (2 VA max) RJ45 connection (to C1000) 3.23 (82 mm) REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 7

Digital Sensor (PL-T500) Dimensions and Wiring Schedule override: Hold 3 seconds Change unit F/ C: Double-click 4.96 (126 mm) 1.30 (33 mm) 8 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

INT A (+) INT B (-) 24VAC COM Communication (RS485) Power (2 VA max) RJ45 connection (to C1000) 3.23 (82 mm) REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 9

Digital Sensor (PL-T1000) Installation 1. Open casing to remove back cover by pushing on the tab located underneath the thermostat. (See Figure 1) 2. Pull wire(s) throught central hole of back cover. 3. Screw in the back cover to the wall. 4. Connect wires: If using twisted pair wires: - Pull out screw terminal block. - Remove 1 cm insulation from each wire. - Connect the wires to the terminal blocks and reconnect the terminal blocks. (See Figure 2) If using CAT5 cable: - Plug the cable into the RJ45 jack of the T1000 (if CAT5 cable is opened at the controller, refer to Figure 3 for pinout of the T1000 s RJ45 jack). 5. Reconnect top cover. IMPORTANT! Do not install the thermostat under the following conditions: Any location exposed to direct sunlight. On an outside wall. Near an air dischatge grill. In a location where vertical sir circulation is retricted. Near a dimmer switch. 10 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

Figure 1 Figure 2 INT A INT B 24 VAC COM RJ45 (Female) 24V Figure 3 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 11

Digital Sensor (PL-T1000) Auxiliary Analog Input The T1000 has auxiliary analog input which can be used to connect another thermistor. The T1000 can be configured to use this alternate temperature reading for a variety of functions, including temperature averaging or radiant floor slab temperature. The alternate thermistor (10KΩ type 3) can be connected to the auxiliary input using the AUX IN and COM pins. (See figure below) 5 6 7 8 9 10 Analog Input Operation The T1000 is controlled using the circular touch pad on the bottom half of the thermostat. The touch pad uses capacitive sensing technology to detect finger proximity. There are no moving parts to push or rotate. The T1000 is controlled using simple scrolling, tapping or holding motions, performed around the circle of the touch pad. The center of the circle is unused. Scroll clockwise or counterclockwise to adjust or navigate Tap here to go BACK Tap here to ENTER 12 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

Changing the Setpoint Home Screen Setpoint Screen View current zone temperature Scroll or tap (any direction) Tap anywhere (or simply wait) return to Home Screen Heat SP Cool SP Adjust your setpoint by scrolling clockwise or counterckwise Schedule Override The First, go to the Setpoint screen. The sun icon is displayed when overridden The moon icon indicates unoccupied mode 67.5 79.5 67.5 79.5 OVERRIDE ACTIVE (Occupied mode) Scroll clockwise to override REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 13

VAV Zone Controller (PL-C1000-VAV) 32-122 F (0-50 C) Non-condensing 14 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

INT Port: Incoming Modbus RS485 communication from digital sensor -OR- Remote computer with Prolon Focus software NET Port: Incoming Modbus RS485 communication - OR - BACnet MS/TP Digital Input for night setback / Standby mode Multi-function analog input Common for all the inputs Temperature setpoint (0-10K potentiometer) Room temperature sensor (10K thermistor) Output 5 (analog 0-10VDC) (Max Current: 40 ma) Output 4 - Isolated or source, TRIAC 24 VAC (max current: 300 ma) Output 3 - Isolated or source, TRIAC 24 VAC (max current: 300 ma) Output 2 - Isolated or source, TRIAC 24 VAC (max current: 300 ma) Output 1 - Isolated or source, TRIAC 24 VAC (max current: 300 ma) Power source of the controller (24 VAC - Class 2) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 15

VAV Zone Controller (PL-VC2000) 32-122 F (0-50 C) Non-condensing 16 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

Network communication General purpose analog input (0-5 VDC, 4-20mA, 10K thermistor) Supply / Radiant / Zone / Occupancy / Discharge Digital sensor (T1000, T500 or T200) / Remote computer with Focus Analog output (0-10 VDC) (max current: 40 ma) Digital output - Isolated Triac Dry contact (24 VAC) (max current: 750 ma) Power source of the controller (24 VAC - Class 2) Service pin Airflow Sensor (PL-VC2000-PI) Airflow sensors are only included in the PL-VC2000-PI models only. Adding an airflow sensor to the Prolon VC2000 lets it regulate the airflow as well as temperature in a zone, independently of the static pressure variations of the system. The default flow sensor has a range of 0 to 2 in H20 (0 to 500 Pa). Depending on the flow cross used, this translates to roughly 0-3500 ft/min. culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN 17

Compliance Digital Sensor (PL-T1000) FCC Compliant to CFR47, Part 15, Subpart B, Class B Industry Canada (IC) Compliant to ICES-003, Issue 5: CAN ICES-3 (B) / NMB-3(B) RoHS Directive (2002/95/EC) VAV Zone Controller (PL-C1000-VAV / PL-VC2000) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 CAN/CSA-C22.2 No. 2015-12, Signal Equipment FCC Compliant to CFR47, Part 15, Subpart B, Class B Industry Canada (IC) Compliant to ICES-003, Issue 5: CAN ICES-3 (B)/NMB-3(B) RoHS Directive (2002/95/EC) FCC User Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment regulations. Cet appareil numérique de la Classe (B) respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada. Technical Specifications PL-RS / PL-T200 Supply: 24 VAC ±10%, 50/60 Hz Consumption: 2 VA max PL-T500 / PL-T1000 Supply: 24 VAC ±10%, 50/60 Hz Consumption: 5 VA max PL-C1000-VAV Supply: 24 VAC ±10%, 50/60 Hz Consumption: 2 VA (Typ), 32 VA (Input) PL-VC2000 Supply: 24 VAC ±10%, 50/60 Hz, Class 2 Consumption: 3 VA (Typ), 5 VA (Max), 24 VA (Input) 18 REV 1.0 / PL-QCK-WSENSOR/VC2000-EN