Butterfly valves PN6, PN10, PN16

Similar documents
Butterfly valves, PN6, PN10, PN16

Butterfly valves PN6, PN10, PN16

Butterfly valves PN 16

Butterfly valves PN 16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Three-port slipper valves PN10, female-threaded

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Electromotoric Actuators

2-port seat valves PN16 with flanged connection

3-port seat valves PN16 with flanged connection

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Electromotoric Actuators

2-Port Seat Valves with Flange, PN 25

2-port ball valves with flanged connection, PN25

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

Electromotoric Actuators

3-port seat valves PN16 with flanged connection

3-port seat valves PN10 with flanged connection

3-port seat valves PN6 with flanged connection

SQL35.00 SQL85.00 SQK angle of rotation

3-Port Seat Valves with Male Thread, PN 16

2-Port and 3-Port Zone Valves PN 16

2-Port Seat Valves with Flange, PN 25

Electromotoric actuators

3-port seat valves, external thread, PN16

3-Port Seat Valves with Male Thread, PN 16

2-port seat valves PN25 with flanged connection

3-port seat valves PN40 with flanged connection

Two-port seat valves with male thread, PN16

2-Port and 3-Port Zone Valves, PN 16 / 20

2-Port and 3-Port Zone Valves & Actuators, PN16

2-Port and 3-Port Zone Valves PN 16

Electromotoric Actuators

2-port and 3-port valves with T-bypass PN 16

2-port and 3-port ball valves PN 40

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

Modulating control valve PN16 with magnetic actuator

2-Port and 3-Port Zone Valves, PN16

CONTROL EQUIPMENT STAZ-16, STBZ-16

Control shut-off butterfly valves DN 25 DN 200 PN

Motorized Butterfly Valve

2- and 3-port valves with flanged connections, PN 16

3-port valves vxf42..

2- and 3-port valves with flanged connections, PN 16

Electromotoric actuators

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Electric actuators for small valves

Installation Operation Maintenance

Electromotoric Actuators

Motorized Butterfly Valve

2- and 3-port valves with flanged connections, PN 6

BUTTERFLY VALVE 17 SERIES Gearbox

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Actuators for small valves

In district heating, heating, ventilating, and air conditioning systems as DFRQWUROYDOYH

2-position electric actuators with Ball valves VBZ ½...11/4

Type overview. R B2 en-gb subject to changes 1

Motorized Butterfly Valve

Combi valves PN 16 with flanged connections

2-port and 3-port terminal unit valves PN16

Modulating Control Valve PN 16 with Magnetic Actuator

TRF.. series spring return rotary actuators for CCV

Control shut-off butterfly valves DN 25 DN 200 PN

Modulating control valve PN16 with magnetic actuator

2- and 3-port valves with flanged connections, PN 16

2- and 3-port valves with flanged connections, PN 25

Electromotoric Actuators

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

Electrical Actuators

Two-port and three-port small valves PN16, ANSI Class 250

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

BQE: 3-way flanged valve, PN 16

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

BUD: 3-way flanged valve, PN 6 (pn.)

Modulating control valve PN16

ACVATIX MiniCombiValves (MCV)

Differential Pressure Sensors

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

ACVATIX MiniCombiValves (MCV)

2- and 3-port valves with flanged connections, PN 25

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Pneumatic Butterfly Valve Type 3335 / AT

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

Modulating control valves with magnetic actuator PN 16

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Characterized Control Valves Actuators. Technical Databook Ver. 2

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

BUE: 3-way flanged valve, PN 16/10 (el.)

VUD: 2-way flanged valve, PN 6 (pn.)

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Transcription:

4 136 Butterfly valves PN6, PN10, PN16 VKF46... Butterfly valves for fitting between counter-flanges Nominal pressures PN6, PN10, PN16 For fitting between PN6, PN10 or PN16 counter-flanges to ISO 7005 Tight-closing in accordance with DIN3230, air-bubble proof Grey cast iron GG-25 EPDM lining and stainless steel disc (DN40... DN200) or nickel-plated steel (DN250... DN400) DN40... DN400 k vs 50... 14 500 m 3 /h Angle of rotation 90 Actuator flange acc. to EN12116/ISO5211 No maintenance required Optionally equipped with ASK46... manual adjusters Optionally equipped with electric actuators SQL35.00 or SQL85.00 (DN40 to DN125) or SQL36E60 and SQL36E100 (DN150 to DN400) CA1N4136en 11.2000 Siemens Building Technologies Landis & Staefa Division

Application For use as motorised or manual control or shut-off valves in heating, ventilation and air conditioning systems In open and closed circuits For 2-position control (open/closed) For modulating control For boiler sequencing circuits To open or close the flow to a heat exchanger To open or close the flow to complete plant sections Media Medium Temperature Cold water, drinking water 15... 120 C Low temperature hot water/domestic water Brine Demineralised water (softened) Water with antifreeze (max. 50 % vol.) Air Operating pressure Max. 1600 kpa (16 bar) Types Type DN k vs value p max. Actuator flange [mm] [m 3 /h] [kpa] 1) EN12116 VKF46.40 40 50 F04 VKF46.50 50 85 VKF46.65 65 215 1600 VKF46.80 80 420 F05 VKF46.100 100 800 1000 VKF46.125 125 1010 800 VKF46.150 150 2100 1200 F07 VKF46.200 200 4000 400 VKF46.250 250 6400 1000 F10 VKF46.300 300 8500 600 VKF46.350 350 11500 300 VKF46.400 400 14500 200 DN Nominal diameter k vs Nominal rate of flow in acc. with VDI 2176 p max. Maximum admissible pressure differential across the closed valve 1) 100 kpa = 1 bar 10 m w.g. Ordering The valve, actuator and assembly kit must be ordered separately as required. When ordering please specify the quantity, product name and type code. Example: 1 type VKF46.50 butterfly valve, 1 type SQL35.00 actuator and 1 type ASK35.1 mounting set Delivery The valve, actuator and mounting kit are packed separately. 2/8

Compatibility The VKF46... butterfly valves are compatible with ASK46... manual adjusters and SQL35/85... and SQL36E... electric actuators from Landis & Staefa. Valve DN Actuator flange EN12116 [mm] Manual adjuster ASK46... Mounting kit ASK35... SQL35/85... 40 Nm VKF46.40 40 F04 ASK46.1 ASK35.1 1600 VKF46.50 50 VKF46.65 65 VKF46.80 80 F05 ASK46.2 ASK35.2 VKF46.100 100 1000 VKF46.125 125 800 Electric actuators SQL36E60... 100 Nm p max. [kpa] VKF46.150 150 F07 ASK46.3 1200 VKF46.200 200 400 SQL36E100... 400 Nm VKF46.250 250 F10 ASK46.4 1000 VKF46.300 300 600 VKF46.350 350 300 VKF46.400 400 200 Mechanical design Butterfly valve Ring format, cast iron housing with EPDM liner. The valve has a swing-through disc and is suitable for airbubble-tight closure in accordance with DIN 3230, part 3. Disc and shaft in DN40 to DN200 are made from stainless steel; as from DN250 the disc is made from nickel-plated steel. The shaft is sealed with a double O-ring. At the same time, the liner is also used to seal the flange. There is thus no contact between the medium and the valve housing. The position of the valve disc is indicated by a notch on the front of the shaft. Manual adjusters ASK46.1 ASK46.2 ASK46.3 ASK46.4 Lockable level with fixed stops at 0 and 90 as well as precision positioning in 6 increments. Dew point blocking Simple installation With instructions Material: Plastic (ASK46.1 and ASK46.2) Die-cast aluminium (ASK46.3) Manually operated worm gear, allows infinitely variable adjustment between 0 and 90. Self locking Position indication Dew point blocking Simple installation With instructions Material: Die-cast aluminium 3/8

Disposal Before disposal the valve must be dismantled and separated into its various constituent materials. Sizing Flow diagram p v100 [bar] 00251en 20000 0,01 0,02 0,03 0,05 0,07 0,1 0,2 0,3 0,5 0,7 1 20000. V100 [m 3 /h] 16000 12000 10000 8000 6000 4000 3200 2400 2000 1600 1200 1000 800 600 400 320 240 200 160 Media water at 20 C DN -k vs 400-14500 350-11500 300-8500 250-6400 200-4000 150-2100 125-1010 100-800 80-420 16000 12000 10000 8000 6000 4000 3200 2400 2000 1600 1200 1000 800 600 400 320 240 200 160. V100 [m 3 /h] 120 100 80 60 65-215 120 100 80 60 40 32 24 20 16 12 10 8 6 50-85 40-50 40 32 24 20 16 12 10 8 6 4 1 2 3 5 7 10 20 30 50 70 100 p v100 [kpa] 4 V 100 = Flowrateinm 3 /h 1m 3 / h = 0,278 kg/s water at 20 C 100 kpa = 1 bar 10 m w.g. 4/8

Flow characteristic 1,0 00314en 0,8 Flow k v /k vs 0,6 0,4 0,2 0 0 10 20 30 40 50 60 70 80 90 Turning angle Engineering The VKF46... butterfly valves can accommodate flow in either direction. Mounting Mounting instructions are enclosed with the valve, the manual adjuster or the electric actuator. Orientation Permissible Not permissible Maintenance The VKF46... butterfly valve requires no maintenance. Caution Before performing any service work on the valve, actuator and/or mounting kit: Switch off the pump and power supply, close the main shut-off valves in the pipework, release pressure in the pipes and allow them to cool down completely. If necessary, disconnect electrical connections from terminals. The valve must be re-commissioned only with the manual adjuster or the actuator correctly assembled. Warranty All terms of the Landis & Staefa warranty will be invalidated by the use of actuators from other manufacturers. The technical data in relation to pmax, leakage rates, noise and service-life are valid only in conjunction with the Landis & Staefa type SQL... actuators listed under "Compatibility". 5/8

Technical data Operating data PN PN6, PN10, PN16 Characteristic Equal percentage Leakage Air-bubble tight to DIN3230, sheet 3, class 1 Flanged connection for pipes PN6, PN10, PN16 to ISO7005 Overall length EN558, series 20 Mounting flange for electric or manual adjuster EN12116 / ISO5211 Angle of rotation 90 Materials Body Grey cast iron GG-25 Shaft Stainless steel Valve disc DN40... DN200 DN250... DN400 Manual adjuster Liner Stainless steel Nickel-plated steel Plastic / die-cast aluminium EPDM (Ethylene Propylene Dien Rubber) Dimensions / Weight Dimensions See table under «Dimensions» Weight See table under «Dimensions» 6/8

Dimensions All dimensions in mm D5 Y X 00252 G J* T L Z F DN A C E1 E2 B Type DN A B C G J* T D5 L PN6 PN10 PN16 X Y Z Wt [mm] ø ø øe1 F øe2 F øe2 F [kg] VKF46.40 40 33 140 82 64.5 113 10 54 11.5 100 M12 (4x) 110 M16 (4x) 110 M16 (4x) 11 42 6 1.8 VKF46.50 50 43 157 95 83 126 10 54 11.5 110 M12 (4x) 125 M16 (4x) 125 M16 (4x) 11 42 6 2.2 VKF46.65 65 46 177 115 91.5 134.5 10 54 11.5 130 M12 (4x) 145 M16 (4x) 145 M16 (4x) 11 42 6 2.9 VKF46.80 80 46 192 138 102.5 157 10 65 15.5 150 M16 (4x) 160 M16 (8x) 160 M16 (8x) 14 50 7 4.0 VKF46.100 100 52 221 158 113.5 167.5 10 65 15.5 170 M16 (4x) 180 M16 (8x) 180 M16 (8x) 14 50 7 4.8 VKF46.125 125 56 256 188 126 180 10 65 15.5 200 M16 (8x) 210 M16 (8x) 210 M16 (8x) 14 50 7 6.5 VKF46.150 150 56 281 212 149 203 12 90 18.5 225 M16 (8x) 240 M16 (8x) 240 M20 (8x) 17 70 9 8.4 VKF46.200 200 60 320 268 174.5 228.5 12 90 18.5 280 M16 (8x) 295 M20 (8x) 295 M20(12x) 17 70 9 10.7 VKF46.250 250 68 403 320 210 266 15 125 23.5 335 M16(12x) 350 M20(12x) 355 M24(12x) 22 102 11 20.0 VKF46.300 300 78 478 370 235 290.5 15 125 23.5 395 M20(12x) 400 M20(12x) 410 M24(12x) 22 102 11 24.5 VKF46.350 350 78 522 408 259 332 20 125 28.5 445 M20(12x) 460 M20(16x) 470 M24(16x) 22 102 11 39.4 VKF46.400 400 102 596 470 303 363 20 125 28.5 495 M20(16x) 515 M24(16x) 525 M27(16x) 22 102 11 58.7 A Corresponds to overall length acc. to EN558, series 20 H Overall height of valve from centre of pipe * Dimension for actuator connection from centre of pipe Overall height of valve and actuator = Valve installation height (J*) from middle of pipe + Installation height of SQL35/85... actuator incl. ASK35... mounting kit = 168 mm (DN40... DN125) + Installation height of SQL36E60... actuator = 158 mm (DN150... DN200) + Installation height of SQL36E100... actuator = 228 mm (DN250... DN400) + Minimum clearance (> 200 mm) from ceiling or wall for mounting, connection, operation, service etc. 7/8

ASK46.1 ASK46.2 ASK46.3 A 00316 B X C Y D Type DN A B C D X Y Wt [mm] ø [kg] ASK46.1 40... 65 155 68,5 67,5 5,5 11 42 0.11 ASK46.2 80... 125 195 79,5 72,5 6,5 14 50 0.16 ASK46.3 150... 200 276 98 90 9,0 17 70 0.50 ASK46.4 A B 00317 G I H J F E C D X Y Type DN A B C D E F G H I J X Z Wt [mm] ø [kg] ASK46.4 250... 400 252 67 200 129 60 29 137 150 60 62 22 100 3.38 8/8 2000 Siemens Building Technologies Ltd. Subject to change