Safety Switches with Separate Actuator SKC

Similar documents
Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Installation and Operating Instructions

Installation and Operating Instructions

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Technical data. Standards: IEC/EN BG-GS-ET-15

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

AZM 161SK 12/12RKED/TU 024

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Safety door-handle system STS

Safety switches for hinged doors

Single foot switches PX and PA series

Floor and fine adjustment switches

Single foot switches PX and PA series

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Position switches FR series

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Safety switches / Position switches / Command devices

SIGUARD Safety Systems Safety Integrated

3SE3 2 SIGUARD Position Switches

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

3SE3 1 SIGUARD Position Switches

SFS-UFS Single Foot Switches

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Safety switches for hinges

BETA Switching Switches and Light Indicators

Position Switches Series 8070/2

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Position Switches Series 8074/2

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Safety switches with separate actuator

Safety switches with separate actuator

Operating instructions Solenoid interlock EX-AZM About this document. Content

SERIES MINIATURE SNAP-ACTION SWITCHES

FL series position switches

Position Switches Series 8060/2

Load disconnect switch Series 8146/5-V11

Miniaturized limit switches

Special Purpose Fuses

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

Thermal Overcurrent Circuit Breaker 3120-F...

Position switches FR series

Microswitches MK series

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Safety switches for hinged doors

Position switches FC series

Microswitches M series

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Switches with manual reset

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Fuse switch disconnectors

Pre wired limit switches

LR-LX-LK-LW Safety Switches with separate actuator

Prewired position switches FF series

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Safety rope switch without reset for simple stop

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Thermal Overcurrent Circuit Breaker 3120-F...

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Safety rope switches with reset for emergency stop

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

Fuse switch disconnectors

Position switches FD series

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Application Mini Contactors for Motors and Resistive Loads

Safety Switches with Separate Actuator, Plastic Housing

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Limit Switch - Prewired Type Metal Body

Gross Automation (877)

Microswitches MK series

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Thermal Overcurrent Circuit Breaker 3120-F...

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

LK Position Switches TECHNICAL DATASHEET.

W Datasheet: DIN Rail Contactors, series AMPARO

NHP SAFETY REFERENCE GUIDE

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

K50H004UP cam changeover switch - 4-pole A - screw mounting

Emergency pull-wire, Belt-alignment, Slack-wire switches. Automation. Catalogue // SYSTEMATIC CONTROL SWITCHGEAR

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Transcription:

Safety Switches with Separate Actuator SKC In terms of lengths, the SKC safety position switch is the 15 mm shorter variant of the SK. This makes it the right choice for confined installation conditions. 2 The SKC otherwise offers the same advantages as the SK: Industrial standard with particular emphasis on safety, personal protection, variable actuator head with two actuator openings. Other decisive advantages include: l Different actuating forces: Corresponding to your specific application, in addition to the standard 10 N, you can also choose an actuating force of 5, 20, 30 or 50 N. Actuating forces from 30 to 100 N can be realised with the aid of additional components that are mounted on the outside of the switch. l Anti-tamper facility: The switching system is protected by multiple coding to ensure enhanced safety of your application. l Outstanding handling: With the two slots you can easily adjust the SKC safety switch and lock it in position by means of the two holes accessible from the top or the two holes accessible from the front. The switch can be wired from three different sides. A transparent cover prevents foreign particles from entering the contact space while connecting the power supply cable. Cap R min 150 mm (5.9") Actuator: Metal Technical data Electrical data Rated insulation voltage i max. 250 V AC Rated operating voltage e max. 2 V Conventional thermal current I the 5 A tilization category AC-15, e /I e 2 V / 1.5 A data frequency 30/min. 1 x 10 6 switching cycles B10d (up to) 1 2 Mill. Short-circuit protection Protection class II, Insulated Ambient temperature -30 C... +0 C Protection class IP65 conforming to IEC/EN 609 Type of connection Screw connections Conductor cross sections Single-wire 0.5-1.5 mm 2 or Stranded wire with ferrule 0.5-1.5 mm 2 Enclosure Thermoplastic, glass fibre-reinforced (L94-V0) Cable entry 3 x M16 x 1.5 Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 1 Depending on switching system. See Table on Pages 76-79.

SK The SK safety position switch is an industry standard and can be used in virtually any application. Thanks to design safety features conforming to VDE 0660 T200, IEC 60947-5-1 and the test regulations GS-ET 15, the SK is particularly suitable for personal protection applications. Its versatility is enhanced by the variable actuator head and two actuator openings. Other decisive advantages include: l Different actuating forces: Corresponding to your specific application, in addition to the standard 10 N, you can also choose an actuating force of 5, 20 or 30 N. Actuating forces from 30 to 100 N can be realised with the aid of additional components that are mounted on the outside of the switch. l Anti-tamper facility: The switching system is protected by multiple coding to ensure enhanced safety of your application. l Outstanding handling: With the two slots you can easily adjust the SK safety switch and lock it in position by means of the two holes accessible from the top or the two holes accessible from the front. The switch can be wired from three different sides. A transparent cover prevents foreign particles from entering the contact space while connecting the power supply cable. 50 mm to direction of adjustment Actuator: metal Technical data Electrical data Rated insulation voltage (up to) 1 i max. 0 V AC Rated operating voltage e max. 2 V Conventional thermal current (up to) 1 I the 10 A tilization category AC-15, e /I e 2 V / 1.5 A data frequency 30/min 1 x 10 6 switching cycles B10d (bis zu) 1 2 Mill. Short-circuit protection (up to) 1 Fuse 10 A gl/gg Protection class II, Insulated Ambient temperature -30 C... +0 C Protection class IP65 conforming to IEC/EN 609 Type of connection Screw connections Conductor cross sections Single-wire 0.5-1.5 mm 2 or Stranded wire with ferrule 0.5-1.5 mm 2 Enclosure Thermoplastic, glass fibre-reinforced (L94-V0) Cable entry 3 x M20 x 1.5 Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 1 Depending on switching system. See Table on Pages 76-79. 3

Safety Switches with Separate Actuator SKT SKI operation Standard High actuating force Radius actuation Standard High actuating force Radius actuation 1 NC / 1 NO contact 6016419059 SKT-1Z M3 6016190 SKI-1Z M3 601619139 SKI-1Z FI50 M3 601619123 SKI-1Z MR 1 NC 2 NC 6016469066 SKT-A2Z M3 601669056 SKI-A2Z M3 601669122 SKI-A2Z MR 1 NC / 1 NO contact Overlapping 60166905 SKI-V15Z M3 601669145 601669131 SKI-V15Z FI50 M3 SKI-V15Z MR Approvals 3112503 Standard 3112503 High actuating force 3112503 Radius actuation 39115 4

SKC SK (0.32") 30 (01.1") 7.9 Ø5.1 (0.20") 27 (1.06") (1.14") 30 (1.1") 7.9 Ø5.1 (0.20") 27 (1.07") (1.14").1 (01.15") (1.15") 1.1 (0.71") 5.5 (0.22") 7 (0.2") 75 (2.95") 1.1 (0.71") 5.5 (0.22") 7 (0.2") 90 (3.54") 33 (1.30") M16x1.5 33.5 (1.32") M20x1.5 Standard High actuating force Radius actuation Standard High actuating force Radius actuation 6016119016 SK-1Z M 6116119109 SK-1Z F30 M 601611904 SK-1Z MR 6016169039 SKC-A1Z M 6116169016 SKC-A1Z F30 M 601616907 SKC-A1Z MR 6016169036 SK-A2Z M 6016169053 SK-A2Z F30 M 601616905 SK-A2Z MR 6016169026 SK-V15Z M 6016169061 SK-V15Z F30 M 601616906 SK-V15Z MR z 50 N and 100 N actuating force on request Standard 39114116 High actuating force 3911451914 Radius actuation 39115 z 100 N actuating force on request Standard 39114116 High actuating force 3911451914 Radius actuation 39115 5

Electrical data Type 1 switches function D B10d Normally-closed contact 2NC A2Z 0 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 10 x 10 6 20 mill. Changeover contact 1NC/1S 1Z 0 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 10 x 10 6 20 mill. Changeover contact, overlapping 1NC/1S V1Z 0 V 16 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 10 x 10 6 20 mill. Normally-open contact 2S E2 0 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 10 x 10 6 Snap-action contact D function B10d Normally-closed contact 2NC SA2Z Changeover contact 1NC/1S S1Z 0 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 10 x 10 6 20 mill. Normally-open contact 2S SE2 Type 2 switches SKT function B10d i I the Normally-closed contact 1NC A1Z Normally-closed contact 2NC A2Z 250 V 10 A Changeover contact 1NC/1S 1/1Z 250 V 10 A AC-15 e /I e 2 V/3 A DC-13 e /I e 250V / 0.27 A AC-15 e /I e 2 V/3 A DC-13 e /I e 250V / 0.27 A A* 1 x 10 6 B* 1 x 10 5 2 mill. 250 V 10 A A* x 10 6 B* 1 x 10 5 2 mill. 250 V 10 A Changeover contact, overlapping 2NC/1S V15Z 250 V 5 A 250 V 5 A *A = Standard; B = Increased actuating force SK function B10d i I the Normally-closed contact 1NC A1Z Normally-closed contact 2NC A2Z 250 V 10 A AC-15 e /I e 2 V/3 A 1 x 10 6 2 mill. Changeover contact 1NC/1S 1/1Z 250 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 1 x 10 6 2 mill. 250 V 10 A Changeover contact, overlapping 2NC/1S V15Z 0 V 5 A AC-15 e /I e 2 V/1.5 A 1 x 10 6 0,2 mill. ENM2 function B10d i I the Normally-closed contact 1NC A1Z Normally-closed contact 2NC A2Z 0 V 10 A AC-15 e /I e 2 V/3 A 1 x 10 6 2 mill. 0 V 6 A Changeover contact 1NC/1S 1/1Z 0 V 10 A AC-15 e /I e 2 V/3 A Fuse 10 A gl/gg 1 x 10 6 2 mill. 0 V 10 A Changeover contact, overlapping 2NC/1S V15Z 250 V 5 A AC-15 e /I e 2 V/1.5 A 1 x 10 6 2 mill. i I the Rated insulation voltage Conventional thermal output from devices in enclosure 7