AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Similar documents
PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables


SERIES 9000 Double Offset HP Butterfly Valves

SOARER TT BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

SERIES 2100 Resilient Seated Butterfly Valves


SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

SERIES 2200 Replaceable Seat Butterfly Valves

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

HOW TO INSTALL YOUR BOV

PVI 60KW, PVI 82KW, PVI 95KW

TBM Series 3-Way Ball Valve

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

HOW TO INSTALL YOUR BOV

Models P420A-3100 & P420A-5100

Type Flexair Pneumatic Pressure Control Valves


Universal Bevel Drives Service Manual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Electric Actuator Installation, Operation & Maintenance Manual

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

SOLAR DASH CHARGING SYSTEM USER GUIDE

Model. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual SP100W/SP351W

Full View Flow Indicator

INSTALLATION AND OPERATION MANUAL

All products subject to this warranty must be returned for examination, repair or replacement to:

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

MULTIPOSITION AIR CYLINDER

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

SERIES Way Divert Valve Assembly, 2-inch to 4-inch

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

STC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves

DAP-625S and DAP-875S

SERIES 7400 THREE PIECE BALL VALVES

USER S OPERATING AND INSTRUCTION MANUAL

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

TOOLS REQUIRED General mechanic tools

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Operating and Installation Instructions

SERIES 7100 STANDARD PORT BALL VALVES

USER S OPERATING AND INSTRUCTION MANUAL

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

User Guide IGD Series

20250 Module Installation Guide

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Tri-Clover Manual and Air Actuated Fractional Valves

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

Operator s Safety and Service Manual

EWS FLUID END PARTS LIST

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

MODEL 200 MULTI-JET FLOW METER

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SERIES 1000 ELECTRIC ACTUATORS

Female Plug. connecting to Fuel Quantity

STC 2W Series Solenoid Valves

CU6703 Module Installation Guide

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

Utility Controller Hand Air Operated

Crestron MMK-G1-CBF-T Mud Ring Mount Kit for Cameo Installation Guide

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

OWNERS MANUAL JANUARY 2007 ISO

BroadBand PowerShield. 20 AHr Battery. User Manual

SERIES 7200 FULL PORT BALL VALVES

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

ActuLink ABS Module - ABS-MOD-400

Installation and Maintenance Instructions

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Ambient Collection System AT-3000

FCB-450, LCB-600, MCB-800

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Operators Manual. Recirculating Chiller /06/08

MIL-24/2600Q MIL-24/3200DQ

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

PowerMax Diesel Upgrade For Cummins Engines

Model LP200, LP250 & LP250W-MT

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Installation and Maintenance Instructions

A Member of the. Integrated Metering Technologies

L DODGE CUMMINS MK-2 + BLK APPS Mount

Installation Instructions

STC 2L Series Solenoid Valves

Transcription:

AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual NLS Series Pneumatic Level Sensors Rev. A1, 4/07 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com

NLS Series Rev. A1, 4/07 Table of Contents Warranty...3 Specifications...4 Installation...5 Wiring...7 Adjustment Procedure...7 Maintenance...8 Life Expectancy...9 Spare Parts...9 2

Rev. A1, 4/07 NLS Series Warranty and Warranty Restrictions APG warrants its products to be free from defects of material and workmanship and will, without charge, replace or repair any equipment found defective upon inspection at its factory, provided the equipment has been returned, transportation prepaid, within 24 months from date of shipment from factory. THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT EXPRESSLY SET FORTH HEREIN, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No representation or warranty, express or implied, made by any sales representative, distributor, or other agent or representative of APG which is not specifically set forth herein shall be binding upon APG. APG shall not be liable for any incidental or consequential damages, losses or expenses directly or indirectly arising from the sale, handling, improper application or use of the goods or from any other cause relating thereto and APG s liability hereunder, in any case, is expressly limited to the repair or replacement (at APG s option) of goods. Warranty is specifically at the factory. Any on site service will be provided at the sole expense of the Purchaser at standard field service rates. All associated equipment must be protected by properly rated electronic/ electrical protection devices. APG shall not be liable for any damage due to improper engineering or installation by the purchaser or third parties. Proper installation, operation and maintenance of the product becomes the responsibility of the user upon receipt of the product. Returns and allowances must be authorized by APG in advance. APG will assign a Return Material Authorization (RMA) number which must appear on all related papers and the outside of the shipping carton. All returns are subject to the final review by APG. Returns are subject to restocking charges as determined by APG s Credit Return Policy. 3

NLS Series Rev. A1, 4/07 Specifications Operational Versions NLS-1A: NLS-1S: NLS-3: Standard media Corrosive media Economic, light duty Characteristics Detection Range: 8-200 in. (200-5000 mm) Operating Point 1 : 80 ± 10 mm (NLS-1A) (SG = 1.0) 70 ± 10 mm (NLS-1S) (SG = 1.0) 65 ± 10 mm (NLS-3) (SG = 1.0) Release Point 2 : 60 ± 15 mm (NLS-1A) (SG = 1.0) 50 ± 15 mm (NLS-1S) (SG = 1.0) 50 ± 15 mm (NLS-3) (SG = 1.0) Max. Viscosity: 10 P (1/2 in. pipe); 30 P (1 in. pipe); 100 P (2 in. pipe); 250 P (5 in. pipe). Switch Rating: 250 V 10 A AC; 115 V 0.5 A DC; (Resistive Load) 230 V 0.05 A DC Physical Attributes Enclosure Protection: Material: Housing Cover: Housing: Chamber: Diaphragm; Cable Entry: Mounting: Pipe Coupling: IP23 (NLS-1A); IP20 (NLS-1S; NLS-3) ADC (NLS-1A; NLS-1S); SS41 (NLS-3) ADC (NLS-1A; NLS-1S); phenolic (NLS-3) ADC (NLS-1A); SCS13 (NLS3); phenolic (NLS-3) Neoprene (NLS-1A); NLS-3); Viton (NLS-1S) G 3/4 (NLS-1A); rubber bushing: (6 mm dia. hole) G1 male R 1/2 female Notes: 1 Operating point means the position whereat the switch assumes ON as a result of rise of level, such position being represented by dimensions from the pipe end. 2 Returning point means the position whereat the switch assumes OFF as a result of fall of level, such position being represented by dimensions from the pipe end. 4

Rev. A1, 4/07 NLS Series Installation Unpacking When unpacking, do not damage the sensor with mechanical shock. After unpacking, make sure that products you ordered are complete. If any part is missing, wrong or damage, please contact APG. Installation Install the sensor in an area which meets the following conditions: The ambient temperature range is 0 to +70 C (32 to 160 F). Humidity and vibration are low. The NLS sensor should be installed in an area which meets the following conditions: The ambient temperature range: 32 to 160 F (0 to 70 C). Located away from splashing liquid. No corrosive gases (such as NH 3, SO 2, CL 2, etc.) present. Low humidity and vibration. Open container in nonhazardous area. Ample space for maintenance and inspection. Install the NLS vertically from the container top. Provide a G 1 in. female boss on the container top. Be sure to use a suitable gasket, O-ring, or thread tape. 5

NLS Series Rev. A1, 4/07 Notes: When the liquid is not SG = 1.0, divide the switch operating position or switch release position with the actual SG. Example: NLS-1A for SG = 0.8 Switch operating position: 80/0.8 = 100 mm Switch release position: 60/0.8 = 75 mm When the detecting pipe is wider than 1/2 in., the switch operating position drops. To ensure proper operation, the following steps should be followed: Determine switch operation: High level operation Low level operation Determine where the actuation level should be: Distances are measured from the inner surfaces of the mounting plug to the end (inlet) of the detecting pipe. For high level operation: [actuation level] = [switch operating position] + 20 mm (screw length) For low level operation: [actuation level] = [switch release position] + 20 mm (screw length) For example, consider a type NLS-1A needing 200 mm actuation levels (low and high): The pipe must be 300 mm for high level operations. 200 mm + 80 mm + 20 mm = 300 mm The pipe must be 280 mm for low level operation. 200 mm + 60 mm + 20 mm = 280 mm Select the proper material which is compatible with the liquid. Install the detecting pipe into the R 1/2 in. coupling of the NLS. This is coupling must be airtight to insure reliable operation. Use a paste form sealing compound on the coupling. Make sure the diaphragm is mounted in horizontal alignment. 6

Rev. A1, 4/07 NLS Series Wiring Wiring should be in accordance with all local codes. The control cable should be 0.75 mm 2 minimum. The terminal screw is M3.0. The cable gland is JIS F 20a. Switch rating (resistive) 250 V 10 A AC Adjustment Procedure The microswitch position should be adjusted if the switch operating position is changed or the microswitch does not release. If the switch operating position is higher than the desired level, lower the microswitch a little. If the switch operating position is lower than the desired level, raise the microswitch a little. The NLS is designed to use a connecting pipe. Switch operating position and release position in water (SG = 1.0) with 1/2 in., 300 mm length pipe are shown below. Model NLS-1A NLS-1S NLS-3 Switch operating 80±10 70±10 65±10 position (mm) Switch release 60±15 50±15 50±15 position (mm) 7

NLS Series Rev. A1, 4/07 Maintenance As a rule, there is no need to inspect periodically. However, pay attention to the following points. In case of low level detection, if the detecting pipe soaks long in liquid, pressurized air in the detecting pipe is dissolved into liquid. Consequently, actuating level may raise. To prevent it, the NLS must be pulled out and purged at adequate intervals. Replace the diaphragm about once every three year period. Except damaged by corrosive vapor, the diaphragm degradation cannot be checked vertically. Check the microswitch operation. Life of the microswitch is 50,000 actuations or more. Check that the silicon sealant is applied onto the connecting part between the NLS and the detecting pipe. If the seal tape is used, compressed air will leak and switch will not operate properly. 8

Rev. A1, 4/07 NLS Series Life Expectancy Life expectancy of the NLS varies with applications such as corrosive vapor, temperature, microswitch s load, etc. Since the NLS is not in contact with the liquid, it can be used for a long time. Replace expendable diaphragms and microswitches. Spare Parts Model Description Part Number NLS-ACC1 Neoprene diaphragm for NLS-1A 22907-0022 NLS-ACC2 Viton diaphragm for NLS-1S 22907-0023 NLS-ACC3 Neoprene diaphragm for NLS-3 22907-0024 NLS-ACC4 Microswitch assy for NLS-1A 22907-0085 NLS-ACC5 Microswitch assy for NLS-1S 22907-0086 NLS-ACC6 Microswitch assy for NLS-3 22907-0087 9

AUTOMATION P R O D U C T S GROUP, INC. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 1/435/753-7300 Fax: 1/435/753-7490 e-mail: sales@apgsensors.com www.apgsensors.com 1025 W. 1700 N. Logan, UT 84321