FAN-STOP INSTRUCTION MANUAL

Similar documents
SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

MOTORTRONICS Solid State AC Motor Control

SCR Power Controllers

WARRANTY INFORMATION...

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

L I M I T E D L I F E T I M E W A R R A N T Y

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Mechanical Spiral Sensor

Generator Start Control Module

SPC-PANEL Simplex, Single Phase Pump Control Panel

Generator Start Control Module

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

The Da-Lite Difference.

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Pump Installation and Service Manual HRS Hydromatic Retractable System

Installation Manual TWM Performance 2010 Mazda 3 short shifter 5 and 6 speed non-mazdaspeed

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

AUTO CHARGE LPC SERIES

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

AUTO CHARGE D PUMP PLUS

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Operation and Installation Manual

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Read this entire manual before operation begins.

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

LAYCOCK SYSTEMS, INC N. 43 rd Street Tampa, FL

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

BATTERY SAVER LOW RIPPLE HO

Emergency Response Trailer 14

S&S. S&S Oil Supply Line Installation Kit PN (For Harley-Davidson Dyna Models) PN (For FLT Models)

Tower Dryer. Wiring Diagrams Manual PNEG-554r09

LEV/Wn Building A Connected World

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

Special Features. Specifications Motor Types: Sensored Motor Limit: 2.5T (on 2S) Input Voltage: 2-3S LiPo Direction: Forward, Brake, Reverse

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

RVS-AX Instruction Manual

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

GL-235 Solar Pool Controller

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Active Controlled Cooling System

S&S. Installation Instructions for S&S VFI Knock Sensor Kit for 2001-'07 Delphi Style VFI Module (with USB) Instruction

INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Superchips Model 1725 MAX MicroTuner 4.6L Ford Automobiles Vehicle Programming Instructions

The Da-Lite Difference.

Superchips Model 2704 MAX MicroTuner GM Trucks with 6.6L Duramax Diesel Engines Vehicle Programming Instructions

IMPORTANT! 09 to Current Straight Up Electric Billet Center Stand. Dealer and/or Customer must complete the following items: Center Stand Checklist

Installation Instructions Compressor Kit Harley Davidson Dyna Glide Important Notice

Instruction Manual MODEL: AC TRACKTECH T Rev. C. World s First Portable, Remote-Control Aircraft Tugs

The Da-Lite Difference.

The Da-Lite Difference.

INSTRUCTIONS FOR HEAVY DUTY AUTOMATIC STOP COIL WINDING MACHINE CROWN MODELS 2015 & 2016

MIL-24/2600Q MIL-24/3200DQ

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

VW Shift Paddle Kit Installation Instructions

AD-7 THERMAL INDICATING AMMETER

Read this entire manual before operation begins.

Fan Coil Unit (FCU) Fan Motor Control

Thermoelectric Cooling System. Model 5473

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

TECHNICAL INFORMATION

High Velocity Series Air Curtains

AXIJET LEADLAG EXHAUST FAN CONTROL SYSTEM

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Transfer Switch GPTS 30

1.1 Caution Statements

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

Airpax Dimensions, Inc.

SOLSTART Instruction Manual

Timer. TipTop Timers. Installation and Operation Manual

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

BP1204 INSTALLATION/OWNER'S MANUAL

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

Integrated Heating System

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Transcription:

Form 1289 FAN-STOP INSTRUCTION MANUAL IMPORTANT Read these instructions fully BEFORE INSTALLING. Equipment damage and personal injury may result from improper installation and/or use. 1. Instructions 1. 2 Fan Stop The Fan Stop anti-windmilling motor brake, senses when a start is attempted and performs an electronic braking cycle first. The fan is decelerated before it can be started to prevent starting from a reverse direction. 2. Installation and Wiring 2. 1 Mounting Since heat is produced in the Fan Stop control unit, it is important that the device be mounted in a manner to best be able to dissipate heat. If the Fan Stop is supplied as a module, the enclosure should be large enough to allow free circulation of air past the heat sinks. 2. 2 Control Wiring Wires connected to Terminals 3, 4, 7, S, and W will be required to carry control currents only. These may be of the same gauge as those connected to the existing motor starter coil.

2.2.1 Interlock - Terminals 3 and 4 This part of the installation MUST be done before the main power wiring described in section 2.3 The purpose of the interlock is to electrically isolate i.e., lock out the starter contactor during the Fan Stop mode. MAXIMUM CONTROL VOLTAGE IS 240 VAC This is the most important part of the installation. Please read the instructions CAREFULLY! If the interlock is not connected properly, it may be possible to engage the run contactor during the Fan Stop mode, which will damage the unit. Terminals 3 and 4 must be placed in SERIES with the common return wire of ALL starter contactors in the system. NEVER CONNECT TERMINALS 3 AND 4 ACROSS (IN PARALLEL WITH) THE CONTACTOR COIL, OR ACROSS THE POWER LINE! Some common connection points for terminals 3 and 4 include placement in series with the motor overload protection contracts or in series with the control system stop button. Refer to Page 5, Figures 2.4 2.6, for some typical control systems with the interlock Terminals 3 & 4 wired properly. After making the interlock connections, the following test must be performed to insure that the wiring is indeed correct. [ ] With main power off, lift wire from terminal 4 [ ] Apply control (main) power and attempt to start the motor. IF THE MOTOR STARTS, YOUR WIRING IS NOT CORRECT. Turn power off, re-read the material in this section, revise your wiring and try again. If the motor does not start, reconnect terminal 4 and continue with the installation procedure. DO NOT PROCEED UNTIL YOU HAVE SELECTED THE CORRECT WIRES TO PASS THIS TEST. CALL THE FACTORY FOR ASSISTANCE IF NECESSARY. 2.2.2 Wiring of Option Terminals [ ] Autotime-out sensor: connect a wire from T2 on the starter contactor to terminal 7. [ ] Make available from each starter in the system, a DRY, normally open auxiliary contact. Wire all contacts in parallel and connect to terminals S & W. Terminals S & W are located on the right side of the logic circuit board. 2

2.3 Power Wiring Fuses within the Fan Stop are provided for the protection of the internal semiconductors only. The user must provide additional fusing (in accordance with NEC standards) for the protection of the wiring and motor. Connections are to be made in accordance with installation diagram and should conform to national and local electrical codes. In general, the wires connected to Terminals 1, 2, 5, and 6 must be the same gauge as the motor wires. Before installing the Fan Stop, be certain that the power is turned off and locked out. Power should only be applied after all work has been checked, all connections tightened, and all safety features reinstalled. Connect motor Terminals 5 and 6 to the motor. Terminal 5 connects to T3 and terminal 6 to T1. Connect power Terminals 1 and 2 to the motor power source, down stream from a suitable positive disconnect as required by the National Electric Code. Terminal 1 should be connected to L1 and terminal 2 to L3. Refer to Page 5, Figures 2.1 2.3, for some typical power wiring arrangements. 3. Adjustments 3.1 Torque An attempt to engage the starter contactor will result in a transfer into the Fan Stop Mode. The Fan Stop will decelerate the fan to zero speed, and then allow it to start. The rate of deceleration may be adjusted via the FAN TORQUE control, located on the top circuit board. [ ] Adjust the Fan Torque control to mid-position. [ ] Apply main power and wait 30 seconds. [ ] Actuate the motor start control. [ ] The fan will be decelerated to zero speed and then the motor will be allowed to start. NOTE: if the fan has not reached zero speed before the starter contactor was allowed to engage, increase the Fan Torque control. The time between when the start command is issued and the motor actually starts will vary depending upon the windmill and deceleration rates. An automatic timeout circuit disengages the brake at zero speed to keep the delay as short as possible at all times. (The maximum wait time in the Fan Stop Mode is 60 seconds) 3

4. Limitations and Special Characteristics 4.1 System Rest Mode If the start command is canceled before the fan reaches zero speed, the unit will revert to the Rest Mode; both the red and green LED s on the middle circuit board will be out. (In this mode, no current is output to the motor.) The next time a start command is issued, the motor will start directly without the Fan Stop deceleration. Switching the main power off for several seconds, and then on will reset the unit. 4.2 Power or Fuse Failure Loss of power means loss of braking, regardless of whether power is disconnected by a switch, line or internal fuse. This also applies to the Fan Stops internal fuses. 4.3 Power Factor Capacitors Power factor capacitors may NOT be used across the load. Move any such capacitors to the LINE side of the starting contactor. 4.4 Holding Against a Load. The Fan Stop cannot be used as a holding brake. 5. Warranty Each Ambi-Tech product is warranted by the factory for one year to be free from defects in materials and workmanship. Repairs or replacement will be made at the factory, after return authorization, on products returned prepaid. The warranty is VOID if the unit has been tampered with, if fuses of an incorrect type or size have been used, if power has been incorrectly applied to the interlock Terminals 3 and 4, for any other type of misuse. Aside from the above statement of warranty, Ambi-Tech, its agents employees and dealers assume NO LIABILITY, and specifically assume NO LIABILITY FOR ANY CONSEQUENTIAL DAMAGE due to malfunction, failure to function, or improper application of it s products. THE USER ASSUMES FULL APPLICATIONS RESPONSIBILITY. No allowance can be made for removal or installation costs, machine downtime, transportation costs, etc. 4

6. Figures Figure 2.1 Figure 2.2 Figure 2.4 Figure 2.3 Figure 2.5 Figure 2.6 5