File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

Similar documents
File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

COVER PAGE FOR TEST REPORT

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

Max. Input Power (W) Inrush Current (A pk /µs)

UL TEST REPORT AND PROCEDURE

File E Vol 1 Auth. Page 1 Issued: Revised: Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS

SPECIFIC TECHNICAL CRITERIA

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT

UL TEST REPORT AND PROCEDURE

Certificate of Compliance

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

COVER PAGE FOR TEST REPORT

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

SolidMatrix 1206 Fast Acting Surface Mount Fuses

UL TEST REPORT AND PROCEDURE

InMate. Design Guide. Socket Mount, Up to 100 A Using Vicor s Maxi, Mini, Micro Series Modules

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 01ME August 14, 2001 REPORT

Bussmann series Quik-Spec Power Module Switch elevator disconnect

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Engineering Product Specification C310T-SC Series Ceramic tube, Time delay

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

C B. Operating up to 5000m altitude 5 year product warranty Models

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly.

Procedure And/Or Report Material

ZWD100PAF Series Instruction Manual

MS Application. Features. Proportional Valve Actuator General Instructions

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

UL TEST REPORT AND PROCEDURE

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters


RUZ- _/_ Protection (3) Isolation Option (4)

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS


1 Phase electronic contactor (SC 1)

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

Features. Samples. Units Continous: Steady State Applied Voltage: DC Voltage Range (VM(DC)) 150 to 970 V AC Voltage Range (V M(AC)RMS

Subject: SPF 25A and 30A Product Update. Date: May 1, 2017

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

4.4. Rockers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

ZWD225PAF Series Instruction Manual

Non-Spring Return EconoDrive Floating Actuator

Full range of small dimension fast-acting and time-delay fuses. 5x15 mm 5x20 mm IEC 5x20 mm UL 1/4 x 5/8 1/4 x 7/8 1/4 x 1 1/4 x 1-1/4

MOV Transient Voltage Suppressors

S24SP15004 series 60W Single Output DC/DC Converter

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

SolidMatrix 1206 Fast Acting Surface Mount Fuses

Input Voltage Range ±10% Output Voltage Accuracy Line Voltage Regulation RSS, RSS8, RSD, RSD10 1.2%/1% of Vin typ.


LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Full range of small dimension fast-acting and time-delay fuses

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

T75S5D Product Details

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

NTA Series Isolated 1W Dual Output SM DC/DC Converters

Investigation into UK socket-outlets incorporating USB charging points

PG02S Series 2W DC/DC CONVERTER, SIP-Package

Design Standards NEMA

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

FME EMI Input Filters

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Selection Guide Motor Control Device Solutions

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Switches Unlimited Phone: * Fax:

HPS Fusion General Purpose Enclosed Transformer

Page 2-4 Page 2-8. Page Page 2-13

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

File E Project 00SC June 22, 2000 REPORT POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

KCA Series A-Type Breaker (Thermal Cutoff Device)

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

MEE1 Series Isolated 1W Single Output DC/DC Converters

SCXI Power Supply/Float Charger Installation Guide

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

Type MTS Miniature Test Switches

Consumer Aftermarket Product Catalog Glass and Ceramic Tube Fuses

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

LISTING REPORT/INSPECTION PROCEDURE

GMA GDB/GDA MDL MDA. Fuses SMALL DIMENSION. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price

SCR Power Controllers

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Quik-Spec Coordination Panelboard Specifications

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

Power Switching Devices

NKE Series. Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES

S24SP series 40W Single Output DC/DC Converter

Transcription:

File E135493 Project 92ME10175 February 6, 1992 REPORT on COMPONENT - POWER SUPPLIES For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL Vicor Corp. Andover, MA Copyright 1992 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above-named company to reproduce that portion of this Report consisting of this Cover Page through Page 2.

File E135493 Vol. 3 Sec. 1 Page 1 Issued: 1992-02-06 and Report Revised: 2011-02-01 DESCRIPTION PRODUCT COVERED: USR, CNR: Component Power Supplies, Models VI-IAM, VI-AIM, VI-ARM, FiltMod, IAM, FIAM and FARM Series. All models may be followed by additional suffixes as indicated below. GENERAL CHARACTER AND USE: These products are non-isolating power supplies incorporating semiconductor components. They are provided with input and output terminals for connection to the end use equipment. *The power supplies have been investigated for compliance with the Standard for Information Technology Equipment Including Business Equipment, UL60950-1-2007 and CAN/CSA C22.2 No. 60950-1-07, Second Edition, dated March 27, 2007. ELECTRICAL RATINGS: Refer to Ill. 8B, 8C, 8D.

File E135493 Vol. 3 Sec. 1 Page 2 Issued: 1992-02-06 and Report Revised: 2011-02-01 ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE): General - For use only in equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. Special Considerations -The following items are considerations that were used when evaluating these products. *USR - Indicates investigation to the U.S. Standards of Safety of Information Technology Equipment, Including Electrical Business, UL60950-1, Second Edition, for building in, Class I, (Earthed). Conditions of Acceptability - Where installed in the end-use equipment, the following are among the considerations to be made. *1. This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 60950-1-07 / UL60950-1, Second Edition, dated March 27, 2007. 2. The power supply should be installed in compliance with the enclosure, mounting, spacing, casualty and segregation requirements of the ultimate application. 3. Consideration should be given to measuring the temperatures on power electronic components, coils and transformer windings when the power supply is installed in the end-use equipment. 4. Output circuits are not isolated and provide operational insulation only. 5. The unit should be located within an overall enclosure so that live parts are suitably enclosed. 6. The input/output connectors have not been evaluated for field-wiring applications. They are intended only for factory-wiring connections within an end-product. 7. Units were tested with an external fuse. See Table 1 for details. If an alternate external fuse is employed additional testing may be performed in the end product.

File E135493 Vol. 3 Sec. 1 Page 2A Issued: 1992-02-06 and Report Revised: 2009-10-06 Table 1. Product Type Model Fuse VI-IAM VI-A11-CU AGC-20A / 32V VI-AWW-CU AGC-20A /36V VI-A33-CQ 3AB-20A / 60V VI-ANN-CQ 3AB-20A / 80V VI-A66-CQ Buss PC-Tron 5A/250V VI-AIM VI-AIM-xx Buss GDB-6.3A / 250V Buss GDB-7A / 250V Littlefuse 7A 314 series *FIAM FIAM1xyy-aa Bussmann-ABC-10A * FIAM2xyy-aa Bussmann-ABC-20A FARM FARM1xyy-aa Bussmann-ABC-10A FARM2xyy-aa Bussmann-ABC-15A FARM3xyy-aa Bussmann-ABC-10A ARM ARM1-xyzz-aa Bussmann-ABC-10A ARM2-xyzz-aa Bussmann-ABC-15A

File E135493 Vol. 3 Sec. 1 Page 3 Issued: 1992-02-06 and Report Revised: 2011-02-01 CONSTRUCTION DETAILS: General - The design, shape and arrangement of parts shall be as illustrated except where variations are specifically described. Labels - All required labels are Recognized Component (PGDQ2), suitable for the surface involved. Marking - Recognized Company's name or trade name or File Number, E135493, model number and optional electrical ratings. Mechanical Assembly - Unless otherwise stated, all enclosure parts and component mounting assemblies are secured by welding or thread forming screws or machine screws provided with nuts and lockwashers. Soldered Connections - All soldered connections are secured before soldering. When hand soldered, leads on printed circuit boards are bent over prior to soldering. Exception - Printed circuit board assemblies that are wave soldered. *Printed Wiring Boards - Unless otherwise specified, all boards are Recognized Components (ZPMV2), suitable for the solder time and temperature used by the manufacturer, and having a flame rating of V-0 and an operating temperature rating of at least 130 C.

VI-ARM / FARM Family Tree Vin = 115 / 230 Vac (90-132, 180-264), 15 A Max Vout = 375 Vdc Max VI-ARMw-xyzz-aa w = B (Optional, non-safety related) x = Product Grade C = -20 to +100 H = -40 to +100 E= -10 to +100 T = -40 to +100 M = -55 to +100 y = Product Type (Output Power Level) 1 = 500 / 750 W 2 = 750 / 1500 W zz = Pin Style and Baseplate Designator aa = Customer Special Designator FARMwxyy-aa w = Product Type (Output Power Level) 1 = 500 / 750 W 2 = 750 / 1000 W 3 = 500 / 600 W x = Product Grade E = -10 to +100 T = -40 to +100 M = -55 to +100 C = -20 to +100 H = -40 to +100 yy = Pin Style and Baseplate Designator aa = Customer Special Designator

VI-IAM / VI-AIM Model Numbers VI = VI for Standard Product VI = VE for RoHs compliant Model Product Type Input Voltage Output Power VI-A11-CU IAM 24 Vdc 200 W VI-AWW-CU IAM 24 Vdc 200 W VI-A33-CQ IAM 48 Vdc 400 W VI-ANN-CQ IAM 48 Vdc 400 W VI-A66-CQ IAM 300 Vdc 400 W VI-AIM-C1 AIM 85-264 Vac 250W C = Product Grade, C may be replaced by E, I, or M C = -25 to +85/+100 (AIM/IAM) E = -10 to +85/+100 (AIM/IAM) I = -40 to = +85/+100 (AIM/IAM) M = -55 to +85/+100 (AIM/IAM) FIAM Model Numbers FIAMwxyy-aa Input voltage = 48Vdc (36-75) w = Product Type 1 = 10 A 2 = 20 A x = Product Grade C = -20 to +100 T = -40 to +100 H = -40 to +100 M = -55 to +100 yy = Pin Style & baseplate Style (non safety related) aa = Customer Special Designator