SHOULDER TO SHOULDER. The case for paralleling generator sets

Similar documents
POWERFUL LINEUP. Paralleling Generator Sets

SECONDS CAN COST MILLIONS

RESTORE YOUR ENGINE AND YOUR UPTIME. GAS COMPRESSION BUNDLED REPAIR SOLUTION G3516 Engine Overhaul

MARINE BUNDLED REPAIR SOLUTION 3408 Engine Overhaul CUSTOM OVERHAUL SOLUTIONS.

CAT RENTAL POWER GLOBAL SOLUTIONS

RESTORE YOUR ENGINE AND YOUR UPTIME. WELL SERVICE BUNDLED REPAIR SOLUTION 3512 Engine Overhaul

GLOBAL CAT RENTAL POWER SOLUTIONS

YOUR ENGINE OVERHAUL. YOUR CUSTOM SOLUTION.

DG175 GC to DG450 GC GAS GENERATOR SETS

INTEGRATED POWER SYSTEMS FOR MANUFACTURING AND INDUSTRIAL FACILITIES

one giant leap for electric power. The 2-4MW family of diesel generator sets powered by the C175

NEW: CG132B TAKE ADVANTAGE OF DIGITAL ASSISTANCE

Cat MINI HYDRAULIC EXCAVATORS

SHIFT INTO WORK MODE. CAT CX31 AUTOMATIC TRANSMISSION FOR CAT VOCATIONAL TRUCKS

AccuGrade Grade Control System for

Cat 3512 Diesel Generator Sets

Reasons to Choose cat. over the Competition

Cat C Diesel Generator Sets

Cat 3516B Diesel Generator Sets

ALL THE RIGHT CHOICES

Cat 3412 Diesel Generator Sets

YOUR CUSTOM SOLUTION.

NEXT GENERATION EXCAVATORS 320GC I 320 I 323

Cat 3512B Diesel Generator Sets

Cat C32 Diesel Generator Sets

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

CAT HYDRAULIC HOSE SOLUTIONS THE PREFERRED CONNECTION

Cat 3512B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat C Diesel Generator Sets

Cat C32 Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat C32 Diesel Generator Sets

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Power Generation for the Offshore Oil & Gas Industry. C175 Offshore Generator Set

Cat 3512 Diesel Generator Sets

POWER YOUR TELECOM SITE WITH CAT HYBRID POWER FOR TELECOM APPLICATIONS

CAT CG170 K. Series Gas Generator Sets

Flexible, Reliable, Connected Power

Generator Ratings: Protecting your Application. Raphael Timms

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

CAT MINI EXCAVATOR ATTACHMENT OPTIONS

ALL-ROUND VERSATILITY

Cat 3516C Diesel Generator Sets

36 Volt Reach Trucks. Capacity: 2,500-4,500 lb

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Grapple / Machine Compatibility. This matching guide is for indication only. Please contact your dealer for more information.

THE POWER YOU LIVE BY. Caterpillar Marine Generator Sets

Power Generation for the Petroleum Industry C175 Offshore Drilling Module

Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

Cat Articulated Truck Bare Chassis Application Guide

CAT UTILITY ROLLERS. Choose the one that s right for your business

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

EFFICIENT DESIGN 3,000-4,000 LB. CAPACITY ELECTRIC CUSHION TIRE LIFT TRUCKS

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

CAT CG170. Series Gas Generator Sets

EPA Tier 4 and the Electric Power Industry

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in)

C32 ACERT Generator Set Electric Power

ENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S.

LONGER LIFE. LOWER COST. D6T REBUILD OPTIONS

TH255. Super Compact Telehandler

Enclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

MOTOR GRADER. Cat C7.1 Engine meets U.S. EPA Tier 4 Final and EU Stage IV emission standards.

SpecSizer. Krishnan Pandiaraj/Jonathan Swathwood IPSD/GPSD

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

SOUND ATTENUATED ENCLOSURES

DECISION-MAKER PARALLELING SYSTEM. for Industrial Power Systems

CAT 336E HYBRID EXCAVATOR NOW THERE S A HYBRID THAT MAKES BUSINESS SENSE

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

Microgrid Technology. Paul Newman Microgrid Sales Manager North America - West

Microgrid solutions Delivering resilient power anywhere at any time

WHAT S YOUR STANDARD? REASONS TO CHOOSE CAT 10 OVER THE COMPETITION

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

Generator Set Specifications 100 ekw (125 kva)

Walkie End Riders WR 30/40 series Capacity: ton

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

SNOW AND ICE ATTACHMENTS

Electric Pneumatic Tire Lift Trucks. Capacity: 3,000-4,000 lb

EPA TIER 4 AND THE ELECTRIC POWER INDUSTRY. Tim Cresswell Tier 4 Product Definition Manager Electric Power Division

3508 B Industrial Engine

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

DIESEL GENERATOR SET FEATURES

Power Solutions Manager Generac Power Systems, Inc.

Draglines. Product Line

Scoops. Product Line

LISTEN TO THE LIFEBLOOD OF YOUR MACHINE

PARALLELING SWITCHGEAR

3516 B Industrial Engine

DP80N - DP90N - DP100N - DP120N DP135N - DP150N - DP160N Specifications

Telehandler TH C Series

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

REMANUFACTURED PRODUCTS. Cat Reman Products for Engines

Transcription:

SHOULDER TO SHOULDER The case for paralleling generator sets

Your operation. Your decision. Cat expertise. Your Cat Dealer knows when multiple units make more sense than one. Power systems requirements are changing in the digital age. The growing need for clean, reliable power for critical loads can quickly outpace a facility s system. In today s world, facility managers have to design flexibility and reliability into their electric systems and plan for future growth and expansions. Trust your Cat Dealer to provide the knowledge and support you ll need to handle any power challenge, from the simplest backup to the most complex integrated systems.

Scaling for Growth When you identify potential growth on site, your options are limited unless you ve planned for it. Installing a smaller unit now and adding an extra unit when it is needed allows you and your Cat Dealer more flexibility in tackling those challenges. If the variation in load demand between peak demand and off-peak is great, then the ability to drop units off-line will help optimize your fuel consumption, giving you more available hours of operation for your tank size. With a parallel system, you ll have the choice between simple, advanced and custom methods to integrate units that meet your expansion needs. Critical Load and Redundancy Using multiple small units to cover the total peak power demand can allow for critical load redundancy, maximizing your operation s efficiency.

Keep your project moving Using paralleled multiple units gives you more flexibility in sourcing the size of standard generator sets, which may be more readily available than larger custom systems. This means faster turnaround time so you get the power distribution portion of your project done sooner.

Paralleling Options: OPTION 1: On-Package Paralleling Generator Set package controller with paralleling features Supports simple island mode operation only Low voltage application (600V or less) OPTION 2: Paralleling Controls Only (off-package) OPTION 1: On Package Paralleling Remote mounted paralleling controls (wall mounted or floor standing) Includes system-level controls and operator interface Supports more complex applications than Option 1 Low voltage application (600V or less) Load add/shed and generator priority controls are available Can make use of cost effective package-mounted circuit breakers Scalable and flexible design OPTION 3: Traditional Floor Standing Generator Paralleling Controls/Switchgear (off-package) Paralleling controls are combined with switchgear Designs provide complex system-level controls and graphical operator interface Various configurations support applications ranging from simple to the most complex (including paralleling with multiple utility sources) Low and medium voltage variations (600V or less through 15kV and higher) Standard, configurable, and fully customized designs Includes generator paralleling breakers and can provide electrical distribution schemes that closely integrate with site electrical systems Full site monitoring and communications capability are available OPTION 2::Off Package Paralleling Note: While the products noted are available from your Cat Dealer, not all of them can be sourced from Caterpillar Inc. or their affiliated companies; consult your Cat Dealer for full details. OPTION 3: Off Package Paralleling with Switchgear

Single source for sales and service It s simple: The more one source can provide, the more integrated your system can be. Your Cat Dealer offers the expertise and equipment to keep your operation running smoothly. With complete integration of Caterpillar products and support, your Cat Dealer ensures that your electric power needs are met. Call your local Caterpillar Dealer for more information.

LEDE7505-01 2007 Caterpillar All Rights Reserved Printed in U.S.A. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow and the POWER EDGE trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.