Operation Instructions

Similar documents
Installation instruction

Service kw. Industrial Generator Sets. Models: TP /94c

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Operation 10/15/20REOD/REOZD. Industrial Generator Sets. Models: Controller: ADC 2100 Advanced Digital Control TP /05

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

SP6. Automatic Battery Charger. Model

Remote Mount Voltage Regulator Kits PA and PA SD For kw Standby Generator Sets

Models: SP3, SPSS3 Automatic Battery Charger

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

GEN 5.0 Generator Service Manual

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

Sentry Battery Charger. Installation and Operations Manual Section 75

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

A48 / A48B (base plate) BATTERY CHARGER

installation and operating instructions for the following xtreme Battery chargers:

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

User s Manual. Automatic Switch-Mode Battery Charger

NILFISK BA 500 Service Manual

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Installation. Mobile Generator Sets. Model: Paralleling Box GM88594-KP1-QS. Applicable Generator Set Models:

IMPORTANT SAFETY INSTRUCTIONS

12V Manual Battery Charger

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Installation and Operating Instructions (for chargers shown below)

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

IMPORTANT SAFETY INSTRUCTIONS

OPERATOR S MANUAL. Portable Power 950. Model No

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

STEP-BY-STEP INSTALLATION GUIDE

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

AC CONVERTER / BATTERY CHARGER

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Owner s Manual & Safety Instructions

MODEL 6017 OPERATOR'S MANUAL

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Draft. Proprietary Photo. Record Engine Information to reference when ordering parts or obtaining warranty coverage. Engine Model.

AUTO CHARGE D PUMP PLUS

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

FULLY AUTOMATIC SCR BATTERY CHARGER

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Installation and Operating Instructions (for chargers shown below)

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Installation and Operating Instructions (for chargers shown below)

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

BATTERY CHARGER CHR-1445

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Installation Instructions for Load Management Kit A051C329

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

LESTRONIC II BATTERY CHARGER MODEL 07210

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

General Precautions. Personnel Precautions

10 AMP ON BOARD BATTERY CHARGER

BATTERY 8A - 1 BATTERY CONTENTS

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

R-200A R-200B Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

TT /17 INSTALLATION INSTRUCTIONS. Introduction. Required Tools and Equipment

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

LESTRONIC II BATTERY CHARGER MODEL 19740

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Installation Operation Parts

TT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

Installation Instructions for Aux 101 Kit A044Z055

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

4.2 Component Identification

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

DC TO AC POWER INVERTER

Transcription:

Operation Instructions Standby Generator Sets Manual Paralleling Controller Kits Numbers: 326482-326576 328804-328888 For Models: 20-1600 kw

Table of Contents Safety Precautions and Instructions........ 1 Introduction.............................. 4 Service Assistance........................ 4 Specifications............................ 5 Initial Setup.............................. 6 Reactive Droop Compensation Setup....... 6 Load-Sharing Module Setup............... 7 Reverse Power Relay Test................ 7 Operation................................ 8 Features................................ 8 Single Generator Set Operation............ 9 Procedure for Paralleling Multiple Generator Sets................. 9 Procedure for Disconnecting Load from Paralleled Generator Sets.......... 9 Troubleshooting......................... 10 Table of Contents i

Safety Precautions and Instructions A generator set, like any other electromechanical device, can pose potential dangers to life and limb if improperly maintained or imprudently operated. The best way to prevent accidents is to be aware of the potential dangers and to always use good common sense. In the interest of safety, some general precautions relating to the operation of a generator set follow. Below are some general precautions relating to the operation of a generator set. SAVE THESE INSTRUCTIONS. DANGER Warning indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored. Warning indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored. CAUTION Caution indicates the presence of a hazard that will or can cause minor personal injury or property damage if the caution is ignored. NOTE Note communicates installation, operation, or maintenance information that is important but not hazard related. Safety decals are affixed to the generator set in prominent places to advise the operator or service technician of potential hazards. The decals are reproduced here to improve operator recognition. For a further explanation of decal information, refer to the safety precautions throughout this manual. Before operating or servicing the generator set, be sure you understand the messages of these decals. Replace decals if missing or damaged. 1

Accidental Starting Accidental starting. Can cause severe injury or death. Disconnect battery cables before working on generator set (negative lead first and reconnect it last). Accidental starting can cause severe injury or death. Turn generator set master switch to OFF position, disconnect power to battery charger, and remove battery cables (remove negative lead first and reconnect it last) to disable generator set before working on any equipment connected to generator set. The generator set can be started by automatic transfer switch or remote start/stop switch unless these precautions are followed. Battery Sulfuric acid in batteries. Can cause severe injury or death. Use protective goggles and clothes. Battery acid can cause permanent damage to eyes, burn skin, and eat holes in clothing. Explosion. Can cause severe injury or death. Relays in battery charger cause arcs or sparks. Locate in a well-ventilated area. Keep explosive fumes away. Explosion can cause severe injury or death. Battery gases can cause an explosion. Do not smoke or permit flame or spark to occur near a battery at any time, particularly when it is being charged. Avoid contacting terminals with tools, etc., to prevent burns and sparks that could cause an explosion. Remove wristwatch, rings, and any other jewelry before handling battery. Never connect negative ( ) battery cable to positive (+) connection terminal of starter solenoid. Do not test battery condition by shorting terminals together. Sparks could ignite battery gases or fuel vapors. Ventilate any compartment containing batteries to prevent accumulation of explosive gases. To avoid sparks, do not disturb battery charger connections while battery is being changed. Always turn battery charger off before disconnecting battery connections. Remove negative lead first and reconnect it last when disconnecting battery. Sulfuric acid in batteries can cause severe injury or death. Sulfuric acid in battery can cause permanent damage to eyes, burn skin, and eat holes in clothing. Always wear splash-proof safety goggles when working around the battery. If battery electrolyte is splashed in the eyes or on skin, immediately flush the affected area for 15 minutes with large quantities of clean water. Seek immediate medical aid in the case of eye contact. Never add acid to a battery once the battery has been placed in service. This may result in hazardous spattering of electrolyte. 2

Hazardous Voltage Electrical Shock Hazardous voltage can cause severe injury or death. Electrically ground generator set before operating. The NEC (National Electrical Code) Article 250-6 addresses portable generator set electrical grounding. Due to variations in local codes, a grounding electrode is not provided. For electrical grounding in your particular application, consult your local codes or a qualified electrician. Hazardous voltage. Backfeed to utility system can cause property damage, severe injury, or death. When generator set is used for standby power, use an automatic transfer switch to prevent inadvertent interconnection of standby and normal sources of supply. Hazardous voltage can cause severe injury or death. Whenever electricity is present, there is the hazard of electrocution. Open main circuit breaker on all power sources before servicing equipment. Electrically ground the generator set and electrical circuits when in use. Never come into contact with electrical leads or appliances when standing in water or on wet ground, as the chance of electrocution is increased under such conditions. Hazardous voltage can cause severe injury or death. Disconnect generator set from load by opening line circuit breaker or by disconnecting generator set output leads from transfer switch and heavily taping ends of leads. If high voltage is transferred to load during test, personal injury and equipment damage may result. Do not use the safeguard circuit breaker in place of the line circuit breaker. Hazardous voltage can cause severe injury or death. Short circuits can cause bodily injury and/or equipment damage. Do not contact electrical connections with tools or jewelry while adjustments are made. Remove wristwatch, rings, and jewelry that can cause short circuits. Hot Parts Hot engine and exhaust system. Can cause severe injury or death. Do not work on generator set until it is allowed to cool. Hot parts can cause severe injury or death. Avoid touching generator set field or exciter armature. Generator set field and exciter armature will become hot if shorted. Hot parts can cause severe injury or death. Do not touch hot engine parts. An engine gets hot while running and exhaust system components get extremely hot. Moving Parts Rotating parts. Can cause severe injury or death. Do not operate generator set without all guards, screens, and covers in place. Exposed moving parts can cause severe injury or death. Keep hands, feet, hair, clothing, and test leads away from belts and pulleys when generator set is running. Replace guards, screens, and covers before operating generator set. NOTE Hardware Damage! Engine and generator set may use both American Standard and metric hardware. Use the correct size tools to prevent rounding of bolt heads and nuts. 3

Introduction These instructions cover the general operation of the manual paralleling controller. Read through these instructions and carefully follow all procedures and safety precautions to ensure safe and efficient generator operation. Keep these instructions with the generator set for future reference. All information found in this publication is based on data available at time of printing. Kohler Co. reserves the right to make changes to this literature and the products represented at any time without notice and without incurring obligation. Service Assistance For service or information, check the yellow pages of the telephone directory under the heading GENERATORS ELECTRIC for an authorized service distributor/dealer. KOHLER CO., Kohler, Wisconsin 53044 U.S.A. Phone: 414-565-3381 Fax: 414-459-1646 (North American Sales) 414-459-1614 (International) For Sales and Service in U.S.A. and Canada Phone: 1-800-544-2444 Model No. Specification No. Serial No. Engine No. Accessory Nos. In any communications regarding your generator set, please include the MODEL, SPEC, and SERIAL numbers found on the nameplate attached to the generator set and the ENGINE number found on the engine nameplate. In addition, add part nos. of ACCESSORIES when available. A nameplate located inside the junction box identifies factory-installed accessories. Enter numbers in spaces provided. This information will enable your authorized service distributor/dealer to supply the correct part or data for your generator set. Part numbers do not appear in this manual due to variations in this series of generator set models. 4

Specifications The manual paralleling controller meets the need for an economical method of manually paralleling two generator sets. It also provides the reliability of the proven Kohler Decision Maker microprocessor controller. Large switchgear-style cubicles are unnecessary. An oversized controller box mounted on the generator set encloses the syncronizer controls. When two generator sets are parallel, the manual paralleling controller allocates the load between the generator sets based on their power ratings. Kohler designed the manual paralleling controller to parallel similar generator set families (20-300 kw or 350-1600 kw). The manual paralleling controller cannot parallel two generator sets from different manufacturers. The manual paralleling controller can parallel only generator sets with the same rotor pitch, electronic governor, and voltage regulator. If the need to parallel two dissimilar generator sets arises, ask your local distributor for information on the complete line of Kohler paralleling switchgear. 5

Initial Setup Accidental starting. Can cause severe injury or death. Disconnect battery cables before working on generator set (negative lead first and reconnect it last). Accidental starting can cause severe injury or death. Disconnect battery cables (remove negative lead first and reconnect it last) to disable generator set before working on any equipment connected to generator set. The generator set can be started by the remote start/stop switch unless this precaution is followed. Hazardous voltage. Moving rotor. Can cause severe injury or death. Do not operate generator set without all guards and electrical enclosures in place. Hazardous voltage can cause severe injury or death. Whenever electricity is present, there is the hazard of electrocution. Open main circuit breaker on all power sources before servicing equipment. Electrically ground the generator set and electrical circuits when in use. Never come into contact with electrical leads or appliances when standing in water or on wet ground, as the chance of electrocution is increased under such conditions. Hazardous voltage can cause severe injury or death. Short circuits can cause bodily injury and/or equipment damage. Do not contact electrical connections with tools or jewelry while adjustments are made. Remove wristwatch, rings, and jewelry that can cause short circuits. Reactive Droop Compensation Setup For reactive droop compensation adjustment of 350-1600 kw generator sets refer to TP-5579. To test and adjust the reactive droop compensator for 20-300 kw generator sets proceed as follows. Read entire procedure before beginning. 1. Set the reactive droop rheostat at minimum (full counterclockwise position [ccw]). 2. Move the voltage sense lead inside the controller from terminal V7 to terminal V9. 3. Start the generator set and adjust the voltage using the voltage-adjusting potentiometer to rated system voltage. 4. Check droop compensation on each generator set as follows: a. With the first generator set operating at rated speed and voltage, apply a resistive load (1.0 pf) until rated current is obtained. b. Adjust the reactive droop rheostat to obtain 6-8% droop in voltage. 5. Remove the load from the generator set. 6. Shut the generator set down by placing the RUN/OFF-RESET/AUTO switch in the OFF-RESET position. 7. Move the voltage sense lead inside the controller from terminal V9 to terminal V7. Repeat steps 1-7 for any additional generator sets. After adjusting all generator sets, parallel the generator sets. See procedure for paralleling generator sets. 6

In addition to steps 1-7, use the following procedure to ensure the units are sharing the reactive load correctly: 1. Parallel the units at one-half to full load. Check the wattmeters to determine that each generator set is carrying equal kw load or a load proportional to its capacity. If the loads are incorrect, adjust and recheck the governor throttle control to balance loading. Engine speed will determine load-sharing ability. 2. With the load balanced, check the ammeters to verify equal current and that the current is proportional according to capacity. If the currents are incorrect, adjust the reactive droop rheostat to reduce the highest reading. Load-Sharing Module Setup Use the following procedure to calibrate the load-sharing module for a 3% droop. 1. With the droop adjustment pot in the fully counterclockwise position, calibrate the 8000 governor as described in the DYNA 8000 technical manual (F-23721). 2. Set no-load speed to rated frequency. 3. Adjust the AC line voltage for rated value. 4. Start the first generator set and apply 100% load. 5. While monitoring the frequency adjust the droop set potentiometer clockwise to achieve 3% droop. 6. Unload the generator and repeat steps 1 through 4 on the remaining generator sets. 7. After adjusting all the generators for equal droop, parallel the generator sets. See procedure for parallel generator sets. 8. If the governors are unstable when the generator sets are paralleled, repeat steps 4-7 and gradually increase the percentage of droop until stable. NOTE If there is unequal loading of the phases, the droop will not be linear but the units will share load proportionally. Reverse Power Relay Test To test the reverse power relay, proceed as follows. Read the entire procedure before beginning: 1. Start the generator set and adjust the voltage using the voltage-adjusting potentiometer to rated system voltage. 2. Close the generator set s circuit breaker. 3. Press the PUSH TO TEST switch on the reverse power relay module. 4. The generator set s circuit breaker will open and the reverse-power relay shutdown lamp will illuminate. 5. Press the reverse-power reset button to reset the relay. Repeat steps 1-5 for any additional generator sets. 7

For identification of manual paralleling controller components and an explanation of their function, refer to Figure 1 and the following descriptions. Operation 2 1 3 7 6 5 4 A-328388 1. Reverse Power Shutdown Lamp 2. Reverse Power Reset Pushbutton 3. Wattmeter 4. Sync Lights 5. Syncroscope Switch OFF/ON 6. Speed Adjustment Potentiometer 7. Voltage Adjustment Potentiometer Figure 1. Manual Paralleling Component Features NOTE For an explanation of the functions of all controller components not identified, refer to the generator set operation manual. Sync Lights. Lights used for manual paralleling operation. Syncroscope Switch OFF/ON. Switch controls the operation of the synchroscope lights. Reverse Power Reset Pushbutton. Pushbutton resets reverse power shutdown circuit. Reverse Power Shutdown Lamp. Lamp illuminates when reverse power shutdown occurs. Speed Adjustment Potentiometer. Potentiometer adjusts frequency of generator set. Voltage Adjustment Potentiometer. Potentiometer adjusts output voltage of generator set. 8

Single Generator Set Operation Start the first generator set as described in the generator set operation manual. When the generator set is at rated voltage and frequency close the circuit breaker to the load. The first generator can operate from no load to full load as described in the generator set operation manual. Procedure for Paralleling Multiple Generator Sets Parallel two or more generator sets if the load is expected to be greater than the full-load rating of the first generator set. Perform the following steps to parallel additional generator sets: NOTE Do not parallel two or more generator sets without load. A reverse power condition can shut down one of the generator sets. If the load is less than 10% of the full-load rating of the first generator set, shut down all additional generator sets. 1. Start the first generator set according to the procedure in the generator set operation manual. 2. After the generator set is at rated voltage and frequency, close the first generator set s circuit breaker. 3. When the load is at approximately 80% of maximum rated load for the first generator set start an additional generator set. 4. After the incoming generator set is at rated voltage and frequency, place the sync light switch in the ON position. 5. Use the speed pot to adjust the frequency of the incoming generator set until the sync lights darken from full illumination to being dark in a minimum of 20 seconds. 6. After the sync lights are dark for a minimum of 2 seconds close the incoming generator set circuit breaker. 7. Observe the kilowatt meters of the paralleled generator sets. Adjust the speed pot of the second generator to share the load proportionally with the first generator set. Follow the above procedure for paralleling any additional generator sets. Procedure for Disconnecting Load from Paralleled Generator Sets Disconnect a generator set when the total system load drops to less then 50% of the lowest single generator set rating. Open the circuit breaker of the desired generator set to remove it from the load. Allow the generator set to run for an additional five minutes unloaded for a cooldown period, then place the engine control switch in the OFF/RESET position to shut down the generator set. 9

Troubleshooting When troubles occur, do not overlook simple causes which might seem too obvious to be considered. A starting problem, for example, could be attributed to an empty fuel tank. As a general aid to diagnosing common problems, refer to the troubleshooting table below. If the trouble cannot be corrected through routine servicing, contact an authorized service distributor for assistance. Problem Possible Cause Corrective Action Unit will not crank Weak or dead battery Recharge or replace; check charger operation Reversed or poor battery connections Check connections Fuse blown in controller Replace fuse Emergency stop switch activated (local or remote) Fault shutdown Reset controller and emergency stop switch (remote) and air damper (Detroit Diesel Powered) Correct fault and reset controller Unit cranks but will Improper fuel Replace fuel not start No fuel Add fuel; check fuel control circuit Air in fuel system Bleed air from system Air cleaner clogged Clean or replace filter element No AC output Line circuit breaker in the OFF position Return to the ON position Generator problem such as defective Contact authorized service distributor voltage regulator or other internal fault Low output or excessive Unit overloaded Reduce load drop in voltage Engine speed too low Contact authorized service distributor Faulty voltage rheostat or voltage Contact authorized service distributor regulator Unit stops suddenly Low oil pressure shutdown Check oil level. If low, check for leaks High temperature shutdown Check for cooling air restrictions or poor belt tension Low coolant level shutdown (if equipped) Check coolant level. If low, check for leaks Out of fuel Add fuel Overcrank shutdown Reset if overcrank fault reoccurs, contact authorized service distributor Fuse blown in controller Replace fuse if fuse blows again, contact authorized service distributor Engine malfunction Contact authorized service distributor Overspeed shutdown Reset if unit overspeeds again, contact authorized service distributor High oil temperature shutdown Check oil level and type. If shutdown reoccurs, contact authorized service distributor Overvoltage shutdown (if equipped) Contact authorized service distributor Unit stops suddenly Generator master switch in OFF/RESET position Move switch to RUN or AUTO position Emergency stop switch activated (local or remote) Check reason for emergency shutdown; Reset switch 10

Problem Possible Cause Corrective Action Sync Lights do not Syncronizer not turned on Turn syncronize switch to the ON position illuminate Burned-out sync lights Replace sync light bulbs Reverse power shutdown lamp illuminates when the Generator sets not adjusted for paralleling Verify operating voltage of both generator sets is the same circuit breaker is closed Verify that the frequencies of both generators are within.5 Hz of each other Load is below the recommended kw Shut down one of the paralleled generator sets Circuit Breaker trips when Generator sets not syncronized Syncronize generator sets. See it is moved to the closed procedure for paralleling generator sets position Generator set overloaded Reduce load on generator set before closing circuit breaker 11

PRINTED IN U.S.A.