VLF-275 Visible Laser Fault Locator Operating Manual

Similar documents
VFL-280. Visible Fault Locator. Operating Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation Power Management Unit Battery Cables and Battery Harness

PVI 60KW, PVI 82KW, PVI 95KW

Raydot LLC 24 Actuator (115 VOLT)

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

HR-20P Pneumatically Controlled Pressure Regulator

Broadband PowerShield. CP27U Models. User Manual

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Type Maxi Mix III Rotary Shaker

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

Web Volume Control Model WV220

20250 Module Installation Guide

WEB CONTROL PRODUCTS

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

XLR-IR850 Long-Range Infrared Illuminator

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Female Plug. connecting to Fuel Quantity

30100 Module Installation Guide L

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Installation Guide. Marine Filter SURT023M SURT024M

Thermaltake Warranty / Support Information

Power. On Your Terms.

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

15100 Module Installation Guide Mercedes EPA07 w/dpf

FADE Series Wall Axial Fans

10 Year Limited Warranty

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

2015 & 2018 Fender Brace Installation Instructions

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Instruction Manual. Backup Sensor Reversing System RVS-RS103

Transmission Guardian

II DISTRIBUTION & SUBSTATION TYPE C

FCB-450, LCB-600, MCB-800

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

JDCR2000 Module Installation Guide

ActuLink ABS Module - ABS-MOD-400

SOLAR DASH CHARGING SYSTEM USER GUIDE

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

DAP-625S and DAP-875S

JD2800 Module Installation Guide

4-Ton Electric Log Splitter

Installation Instructions

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

Installation and Operation Instructions Safety Director Arrow

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Straight-Bore Clutch LSCC-32, 44, 54

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Installation Instructions

DC to AC Power Inverters

CU6703 Module Installation Guide

Premium Pond Pump 330 Gallons Per Hour

PSC-301 Pump Stroke Counter

Installation Instructions

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

ADI-125/750 ADI-125/1500 ADI-125/2500

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

MM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges

600 Amp Battery Jumper with Air Compressor

Do not install and/or operate this safety product unless you have read and understand the safety information contained

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

ml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Natural Fiber Planter Fountain

SHOTLOCK OWNER S MANUAL TABLE OF CONTENTS -3-

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Installation Instructions

Digital Clock model 75100C

EAGL 1-Touch Laser Level

THIS IS OPTIMA S EXCLUSIVE WARRANTY. NO PARTY IS GRANTED EXPRESS OR IMPLIED AUTHORITY TO CHANGE OR ANNUL THIS WARRANTY IN ANY MANNER.

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation Instructions

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Owner s Guide. Dumbwaiter. Series DUMBWAITER OWNER S GUIDE 1

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Installation Instructions

Premium Waterfall Pump 1200 Gallons Per Hour

Installation Instructions

Frekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual

TECHNICAL INFORMATION

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019

Thermo-Anenometer Model Owner s Manual

INW Panel Meter Reading an INW PT12 Sensor

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

Transcription:

VLF-275 Visible Laser Fault Locator Operating Manual Terahertz Technologies Inc. 169 Clear Road Oriskany, New York 13424 TEL: (315) 736-3642 January 2004

Topic GENERAL INFORMATION Table of Contents Page Introduction...2 Unpacking and Inspection...2 Power Requirements...2 Specifications...3 OPERATING INSTRUCTIONS Operation...4-5 Operating Considerations...6-7 WARRANTY INFORMATION Repair Information...8 Limited Warranty... 8

Introduction TheVLF-275 Visible Laser Fault Locator is battery operated, stabilized, visible laser diode optical source with provision for coupling the laser output to a connectorized fiber. It is intended to allow the precise location of a break or severe microbend in a fiber or cable under test by viewing the emission of visible light at the fault. An optional connection for external AC power is included. Unpacking and Inspection Prior to shipment this instrument was inspected and found to be free of mechanical and electrical defects. Upon acceptance by the carrier he assumes responsibility for its safe arrival. After unpacking, examine the unit for any evidence of shipping damage. Should you receive this instrument in a damaged condition, apparent or concealed, it must be noted on the freight bill or express receipt and signed by the carrier s agent. Failure to do so could result in the carrier refusing to honor the claim. Upon filing a claim TTI should be notified. Power Requirements This instrument is equipped for operation with a 9 Volt Alkaline primary battery. Replacement of the battery may be effected by removal of the battery compartment door located at the lower rear of the unit. Replace only with an equivalent battery. Acceptable replacements include: Duracell MN1604, Eveready EN22, or Rayovac AL-9V. The external wall mount supply does not charge the battery Do not attempt to power the unit from other power supply sources. To do so may result in severe damage to the unit. 2

Specifications Output Power... Wavelength... 0.5-1mW(single-mode) 1.0-2.0mW(multimode) 650 nm +/- 5nm Power Stability... +/- 5% Battery... Battery Life... Pulse Rate... 9 V Alkaline 100 hrs pulsed 7 Hz Duty Cycle... 0.33 Emission Indicator... Standard F/O Connector... Size... Weight... Operating Temperature... Storage Temperature... LED, on insync with laser Universal 2.5 mm ferrule 6.5 L x 3.25 W x 1.125 D 7.5 oz. -10 to 50 C -30 to 60 C 3

Operation The VLF-275 is a hand-held battery powered stabilized fiber optic laser source with optional external AC power adapter that emits visible (red) light at 650 nm. Its intended function is to allow an operator to identify the exact location of a break, microbend, or other discontinuity in a fiber optic cable. As the radiation is visible, light emanating from a break or microbend enables the user to locate the exact position of a fault even at very short distances that would not be detectable by conventional means such as an Optical Time-Domain Reflectometer, (OTDR). It is also useful for identifying a particular fiber in a cable by exciting the fiber to be located with visible radiation. The fiber to be tested is connected to the source by means of a standard fiber optic connector such as an FC, D-4, Biconic, or ST. The source may be used in one of its two modes, Pulsed or Continuous. In the Pulsed Mode the laser is turned on and off at a 7 Hz rate. The laser is on for approximately one third of the cycle. This mode is helpful in permitting the user to identify the source radiation in the presence of high levels of ambient light. It also aids in conserving battery life. The Continuous Mode is intended to be used to measure fiber loss with the aid of an accompanying optical power meter. The operation of the unit is quite simple as there is only one control, namely the power switch. The power switch is a slide switch. Moving the switch to the right, (the FLASH position) selects the mode that generates pulsed laser light. Throwing the switch to the left, (the CONTINU- OUS position) selects that mode which causes the laser to be on continuously. 4

Normal operation is as follows: 1. Ensure that the power switch is in the center, or OFF position. 2. Remove the dustcap from the fiber optic connector. Attach the connector of the fiber to be tested to the unit. 3. Energize the unit by selecting either the pulsed or continuous mode. 4. Light will be coupled out of the fiber under test at a break or a region of high microbending loss. It is at this point that the fiber fault is located. 5. If testing a long fiber, it is recommended that the ambient light level be reduced so that the operator may more easily distinguish the laser light from room light. 6. Use of the CONTINUOUS mode is mainly intended for use with an optical power meter to measure fiber or splice loss. As this mode consumes current continuously, the battery will require more frequent replacement as compared with Pulsed mode. 5

Operating and Safety Considerations Never look directly into the fiber optic connector or the end of a fiber attached to the unit while it is energized. To do so will expose you to laser radiation which is in excess of Class I safety limits. This unit is classified as a Class II laser system and must be used with all commensurate safety precautions. 6

1. The light coupled out of the fiber under test is proportional to the loss incurred at the fault. Severe microbends or breaks will allow light to be viewed through the jacketing of a 3 mm fiber optic cable. This assumes that the fiber jacketing is not completely opaque. If the fiber is inside a completely opaque loose tube buffer, the unit will obviously not be usable for its intended purpose. 2. The unit may be used as a fiber identifier by exciting the fiber to be identified and seeing which fiber at the opposite end of the cable is illuminated. Note: Never view the light emanating from the fiber directly. Place a white piece of paper at the end of the fiber and look for the presence of a red spot on the paper. 3. The usable range for fault location depends on the fiber, the jacketing of the cable and the loss incurred at the fault. Several hundred meters to 1 or 2 Km are typical for singlemode fiber. 4. Certain fibers are more susceptible to microbending losses than others. For example, depressed cladding fiber such as those made by AT&T resist microbends to a greater extent than conventional matched-cladding fibers. Multimode fiber has a much higher resistance to bending loss than does singlemode fiber. 5. Battery replacement is called for when the laser and/or the emission indicator LED on the front panel no longer produce light. Replace with a 9 volt alkaline cell only. Ensure that the power switch is in the off position during battery replacement. Optionally, use the external wall mount power adapter. 7

Warranty And Repair Information REPAIR INFORMATION Products manufactured by Terahertz Technologies Inc. are designed and fabricated to provide reliable performance. However, in the event that service is required, both telephone technical assistance and factory repair services are available. Call (315) 736-3642 for information. For IN-WARRANTY REPAIRS, call us to obtain a Returned Material Authorization number, (RMA Number). All products are to be returned to TTI with freight charges prepaid. Those products sent under warranty will be returned to our customers prepaid. We cannot be responsible for returned products that do not reference the TTI RMA number. For OUT-OF-WARRANTY repairs, services are billable for both time and materials. LIMITED WARRANTY TERAHERTZ TECHNOLOGIES INC. (TTI) WARRANTS THAT TO THE FIRST PURCHASER, FOR A PERIOD OF TWO YEARS FROM THE DATE OF RECEIPT, THAT THIS PRODUCT (THE PRODUCT) WILL BE FREE FROM DEFECTS IN MATERIALS AND MANUFACTURING. THE FORE- GOING WARRANTY IS THE ONLY WARRANTY, EXPRESS OR IMPLIED, GIVEN BY TTI, I.E., THERE IS NO WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. TTI HEREBY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OTHER THAN THE WARRANTY IN THE FIRST SENTENCE TO THE FULLEST EXTENT PERMITTED BY LAW. THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY IS REPAIR OR REPLACEMENT AT TTI S OPTION OF ANY PRODUCT THAT PROVES TO BE DEFECTIVE IN MATERIALS OR MANUFACTURING WITHIN TWO YEARS OF RECEIPT OF THE PRODUCT. NOTE: THIS WARRANTY DOES NOT APPLY TO ANY PRODUCT WHICH HAS BEEN SUBJECT TO MISHANDLING, MISUSE, OR SERVICE BY UNAUTHORIZED PERSONNEL OR TO ANY PRODUCT WHICH HAS BEEN DAMAGED, MODI- FIED, ALTERED OR TAMPERED WITH. TO THE FULLEST EXTENT OF THE LAW, TTI DISCLAIMS ALL LIABILITY FOR ANY OTHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ALLEGED TO BE CAUSED BY A DEFECTIVE PRODUCT, I.E., TTI WILL NOT BE RESPON- SIBLE FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OTHER THAN THE COST OF REPLACING THE PRODUCT OR ANY OTHER MONETARY DAMAGE SUCH AS LOST WAGES OR PROFITS CAUSED BY ANY USE, ATTEMPTED USE OR INABILITY TO USE THE PROD- UCT. NOTE: BY USING THE PRODUCT, YOU AGREE THAT REPAIR OR REPLACEMENT AT TTI S OPTION WILL FULLY SATISFY TTI S WARRANTY OBLIGATION TO YOU, WHETHER IN CONTRACT, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHER APPLICABLE LAW. 8