Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing below deck. User adjustable above-deck mixing uses ceramic disc valve for dependability & long life Mixing handle can be removed for one time temperature setting during installation Product No.'s & Options Specifications How to Install Maintenance FAQ,s Replacement Parts M90 REV.. - - 9 PRODUCT NUMBER 09.0 09. 0.0 0. 09.0 09. 0.0 0. Certified to comply with ASME A..M 0 American Standard NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, please call -00--90 (In Canada: -00--09) (In Toronto Area only: -90-009)
Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing below deck. User adjustable above-deck mixing uses ceramic disc valve for dependability & long life Mixing handle can be removed for one time temperature setting during installation M90 REV.. PRODUCT NUMBER Certified to comply with ASME A..M 0 American Standard To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, (In Toronto Area only: -90-009) Flexible Selectronic Platform with Universal Sensor Easy installation. All electronics in the spout; nothing below deck. User adjustable above-deck mixing uses ceramic disc valve for dependability & long life Mixing handle can be removed for one time temperature setting during installation M90 REV.. For Parts, Service, Warranty or other Assistance, (In Toronto Area only: -90-009) PRODUCT NUMBER Certified to comply with ASME A..M 0 American Standard To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping.. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.. Selectronic Spout Assembly. Mounting Kit. Power Supply. Cable Extension, ". 0' Multi Extension Cable. " Deck plate (optional must be ordered separately). Mixing Valve (optional must be ordered separately). Key for vandal resistant aerator 9. Installation Instructions Less Mixing With Above-Deck Mixing PRODUCT No.s 09.0 09. 0.0 0. PRODUCT No.s 09.0 09. 0.0 0. B a s e P r o d u c t Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Product No.'s & Options Specifications How to Install - Maintenance - FAQ,s Replacement Parts 9 NOTE TO INSTALLER: Please give this manual to the customer after installation. please call -00--90 (In Canada: -00--09) DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. 09.0 09. 0.0 0. 09.0 09. 0.0 0. How to Install - Maintenance - 9 FAQ,s 9 Replacement Parts 9 Installation Instructions SELECTRONIC Hard-Wired, AC Powered Proximity Integrated Faucet with Above-Deck Mixing Product No.'s & Options Specifications 09.0 09. 0.0 0. NOTE TO INSTALLER: Please give this manual to the customer after installation. please call -00--90 (In Canada: -00--09) DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE. 09.0 09. 0.0 0. Deck Plate Mixing Valve 0P00 0XTMV 0P00 M90 REV..
Fig. FINISHED WALL OR BACKSPLASH 9mm (-/) Roughing-in Dimensions MIN. " CLEARANCE 0mm (-/) mm (-/) 9mm (-/) mm ( -/) MOUNTING SURFACE /" COMPRESSION CONNECTORS mm (-/ ) mm () ELECTRICAL BOX OR EQUIVALENT BY OTHERS mm (-/) GENERAL DESCRIPTION: Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. Operates on AC permanent power. Inlets /" compression, built-in checks, flexible stainless steel " reach inlet hoses for spout connection and In-line integral strainer for solenoid. TOOLS REQUIRED; Fig. Fig. Hex Wrench (Included) Adjustable Wrench Plumbers' Putty or Caulking Phillips Screwdriver Tape Measure 0' INSTALLATION CONNECT POWER SUPPLY; Fig.. Contractor to supply ELECTRICAL BOX (). Mount POWER SUPPLY () into ELECTRICAL BOX (). Connect White and Black power connections to POWER SUPPLY (). Fig. a. INSTALL SPOUT ASSEMBLY; Turn off hot and cold water Fig. CAUTION supplies before beginning. Make sure O-RING SEAL (9) is installed.. Installation with ESCUTCHEON () (optional). Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE (). (Only if mounting surface is uneven).. Insert supply HOSES (), SHANK () and POWER CORD (0) (if equipped) through hole in ESCUTCHEON with PUTTY PLATE () and mounting surface. Follow mounting instructions below to secure faucet to mounting surface. (Make sure PIN () is in back).. Installation less ESCUTCHEON (). IMPORTANT: Do not use putty when installing faucet without escutcheon.. Assemble RUBBER WASHER (), BRASS WASHER () and THREADED LOCKNUT () onto SHANK () from underside of sink or mounting surface. Hand tighten LOCKNUT ().. Use a screwdriver to tighten SCREWS () on LOCKNUT (). Work your way around LOCKNUT (), tightening the screws slightly each time until all are snug to ensure even pressure.. Connect the SENSOR CABLE () to the POWER SUPPLY CABLE (). FIG. a. Fig. Fig. Fig. a " ELECTRICAL BOX OR EQUIVALENT BY OTHERS BLACK & WHITE POWER CONNECTIONS 9 0 " ELECTRICAL BOX OR EQUIVALENT BY OTHERS IMPORTANT: Do not use putty when installing faucet without escutcheon. CONNECTOR NOT USED IN THIS INSTALLATION POWER SUPPLY CABLE (OPTIONAL) PUTTY (If required) MOUNTING SURFACE TIGHTEN SPIN NUTS IMPORTANT: Do not use sealent on threads M90 REV..
Fig. Unit # Unit # Unit # Unit # ELECTRICAL BOX OR EQUIVALENT BY OTHERS FOR AC-VERSION (MULTI HOOK-UP); Fig., a. Contractor to supply ELECTRICAL BOX (). Mount POWER SUPPLY () into ELECTRICAL BOX (). Connect White and Black power connections to POWER SUPPLY (). Fig., a.. Connect the SENSOR CABLE () to the SPLITTER (). FIG. b.. Connect the POWER CABLE () to the SPLITTER (). FIG. b.. Connect the 0' MULTI EXTENSION POWER CABLE () to the top of the SPLITTER () and to the bottom of the next SPLITTER and so on. FIG., b. Fig. a Fig. b BLACK & WHITE POWER CONNECTIONS Unit # " ELECTRICAL BOX OR EQUIVALENT BY OTHERS CONNECTOR NOT USED IN THIS INSTALLATION ELECTRICAL BOX OR EQUIVALENT BY OTHERS M90 REV..
Certified to comply with ASME A..M MAKE WATER SUPPLY CONNECTIONS; Fig.. Turn off hot and cold water supplies before beginning. Fig.. Connect FLEXIBLE SUPPLIES (, ) directly to wall supplies. Connection on fitting supplies are /" compression. Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten.. Faucet supplies are " long from faucet base. Note; If additional supply length is required, installer must purchase those parts separately. Important; If SUPPLY HOSES (, ) are too long, loop as illustrated to avoid kinking. HOT COLD IMPORTANT: Do not use sealent on threads INSTALL OPTIONAL MIXING VALVE; Fig. For 09.0 & 09. Faucets. Note; For complete detailed installation and operating instructions see installations instructions supplied with mixing valve. No. M90 Fig. No. M90 Installation Instructions SELECTRONIC Thermostatic Mixing Valve 0XTMV 00 American Standard M90 Specifications Installation Adjust Temperature Service Replacement Parts NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call -00--90 (In Canada: -00--09) (In Toronto Area only: -90-009) MAINTENANCE HAND WASH SENSOR OPERATION; Fig. REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE. When the Sensor detects a user, the water immediately starts to flow. Water flow will stop two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for 9 seconds. The water will stay off until the blockage is removed from the detection zone. Detection Zone: " - 0" (0.mm - mm) Default: Set at Factory " (.mm) Fig. DETECTION ZONE PROTECTIVE FILM M90 REV..
HOW TO CHANGE SENSOR RANGE; (Factory set at ") Fig.,, &.. Setting the Detection Zone (Distance): Remove the FAUCET COVER () by unthreading the LEVER SCREW () and pulling off the LEVER HANDLE (). Unthread the FAUCET COVER SCREW () at the back of the FAUCET. Pull FAUCET COVER () up and off. Fig... Disconnect the BLACK POWER SUPPLY CONNECTOR () and reconnect. Fig.. Fig. REPLACE REMOVE. While the SENSOR CONTROL LED () is blinking slowly, place your hand - in. (.-0.mm) in front of the sensor. Fig... When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. a.. Once the SENSOR CONTROL LED () begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set. Fig.. Replace FAUCET COVER () and LEVER HANDLE (). Install LEVER HANDLE SCREW (), FAUCET COVER SCREW () and tighten. Fig.. Fig. Fig. a "-" (.mm- 0.mm) UP TO 0" (mm) BLINKING LED BLINKING LED M90 REV..
HOW TO REPLACE SENSOR; Fig., &.. Remove the FAUCET COVER () by unthreading the LEVER SCREW () and pulling off the LEVER HANDLE (). Unthread the FAUCET COVER SCREW () at the back of the FAUCET. Pull FAUCET COVER () up and off. See Fig. in this section.. Disconnect both WIRE CONNECTIONS. Fig... Untighten SENSOR SCREW () with a.mm HEX WRENCH. Remove SENSOR ASSEMBLY () from FAUCET BODY (). Remove SENSOR (a) from CARRIER () and replace with new SENSOR (a). Install SENSOR ASSEMBLY () into FAUCET BODY (). Tighten SENSOR SCREW (). Fig.,.. Replace FAUCET COVER () and LEVER HANDLE (). Install LEVER HANDLE SCREW (), FAUCET COVER SCREW () and tighten. See Fig. in this section. Fig. Fig. DISCONNECT WIRE CONNECTIONS.mm HEX WRENCH Fig. a M90 REV..
HOW TO CLEAN FILTER SCREEN ON SOLENOID VALVE; Fig. & 9. Remove the FAUCET COVER () by unthreading the LEVER SCREW () and pulling off the LEVER HANDLE (). Unthread the FAUCET COVER SCREW () at the back of the FAUCET. Pull FAUCET COVER () up and off. See Fig. in this section.. Disconnect WIRE CONNECTION () to SOLENOID VALVE (). Fig... Unthread SOLENOID VALVE () from VALVE BODY (). Fig. 9.. Remove FILTER SCREEN () from base of SOLENOID VALVE (). Rinse clean and replace. Fig. 9. Fig. DISCONNECT WIRE CONNECTION DISCONNECT WIRE CONNECTION. Thread SOLENOID VALVE () into VALVE BODY () and hand tighten. Reconnect WIRE CONNECTION (). Fig... Replace FAUCET COVER () and LEVER HANDLE (). Install LEVER HANDLE SCREW (), FAUCET COVER SCREW () and tighten. See Fig. in this section. Fig. 9 HOW TO REPLACE DIVERTER CARTRIDGE; Fig. 0 &. Remove the FAUCET COVER () by unthreading the LEVER SCREW () and pulling off the LEVER HANDLE (). Unthread the FAUCET COVER SCREW () at the back of the FAUCET. Pull FAUCET COVER () up and off. See Fig. in this section. Fig. 0 9. Pull out LIMITER STOP () from the VALVE STEM (). Unthread COLLAR NUT () from VALVE BODY (). Fig. 0.. Pull DIVERTER CARTRIDGE () out and replace with new DIVERTER CARTRIDGE (). NOTE: Make sure the two ALIGMENT PINS () in the base of the DIVERTER CARTRIDGE () are facing upward. Fig.. Fig.. Replace FAUCET COVER () and LEVER HANDLE (). Install LEVER HANDLE SCREW (), FAUCET COVER SCREW () and tighten. See Fig. in this section. Fig. M90 REV..
CHANGE HOT LIMIT SETTING FROM 9% TO %; Fig.. Remove the FAUCET COVER () by unthreading the LEVER SCREW () and pulling off the LEVER HANDLE (). Unthread the FAUCET COVER SCREW () at the back of the FAUCET. Pull FAUCET COVER () up and off. See Fig. in this section. 9. Replace LEVER HANDLE and rotate counter-clockwise to its stop position (00% cold). Remove HANDLE.. Pull out LIMITER STOP () from the VALVE STEM (). SLOT. Rotate LIMITER STOP () 0 degrees and insert back onto VALVE STEM (). ROTATE 0. Replace FAUCET COVER () and LEVER HANDLE (). Install LEVER HANDLE SCREW (), FAUCET COVER SCREW () and tighten. See Fig. in this section. Fig. SLOT GENERAL CLEANING; Fig.. For general cleaning use a damp, soft cloth to clean the spout and the sensor.. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth. CAUTION Do not scratch the sensor when cleaning. Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor. Fig. FAQ'S Q: How will I know if battery needs to be replaced? A: Valve does not open and sensor blinks times interrupted by pause for up to days. Q: Why has the flow rate of the faucet reduced significantly? A: Check and clean aerator and strainer. Q: There is no flow out of faucet when I'm in the sensor range? A: Check sensor. If sensor blinks times interrupted by pause, replace battery, or call 00--90. Q: What is the normal operating pressure range? A: Faucet will operate with supply pressures ranging from 0-0 psi. M90 REV..