Best Selling 30 % OFF* GC Accessories. Expires: September 27, 2013

Similar documents
GC Accessories. Solutions Guide. Liners Ferrules Cool-Lock Nut. Septa Vials Gold Seals

Choose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide

Choose for Your Instrument

AZ Chrom s.r.o.

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

Selecting The Appropriate INLET LINER

GC Supplies - Varian/Bruker Instrument Quick Pick Guide

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

APPLICATIONS TN Determining the Effects of Harmful LC Solvent Vapors on GC Analysis

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

SGE. Hamilton. Precision. Norm-Ject. NewERA SYRINGE PUMPS. Sampling glass microliter. Plastic Syringes. Stainless Steel. glass microliter.

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories

Genuine Restek Replacement Parts For Agilent 5890 GCs

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan. Phone: Page 4

Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products.

6890 Installing ¼ Glass Columns

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Agilent GCs. Genuine Restek Replacement Parts. More Parts & Accessories for More GC Systems. Innovative Chromatography Products

AZ Chrom s.r.o.

Supported Liquid Extraction (SLE)

High-Performing Restek PAL SPME Fibers

GC Inlet Maintenance:

Sample preparation Methods Analysis. Biodiesel Analysis guide.

trace samples >2µL 4.0mm 6.5mm x 78.5mm accommodates more polar solvents and lower MW solvents 5.0mm 6.5mm x 78.5mm 2.0mm 6.5mm x 78.

Biodiesel Analysis Toolkit

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

Chromatography. Research Supplies. 2014/2015 Catalog

PORTAFOLIO DE CROMATOGRAFÍA LABINS

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Analysis of Petroleum Fractions by ASTM D2887

The next level of True Blue Performance

Instrument Supplies. Instrument Supplies from the specialists in chromatography 233

Swagelok.

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Shimadzu GCs. Genuine Restek Replacement Parts

APPLICATION TN Quantitative Analysis of Cocaine Metabolites and Adulterants in Oral Fluid

Quick Reference Guide. Supplies for Waters HPLC Systems

Thermo Scientific GCs

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Agilent 6890 Gas Chromatograph

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Set Your Sights on Superior Performance

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Spare Parts Catalog. PN , Revision October 2011

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Set Your Sights on Superior Performance

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

CP-3800 GAS CHROMATOGRAPH

Techniques for Improving the Reproducibility of GC Analysis

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

HPLC Essentials Genuine Restek Replacement Parts for HPLC Systems

Agilent 7820A Gas Chromatograph

Setting up SilFlow for BackFlush in your GC

Thermo Scientific GCs

ZB-CLPesticides-1 & -2

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Installing the 6850 Direct Valve Column Connector Kit

GC AND GC/MS. Your Essential Resource for Columns & Supplies

Using the PSD for Backflushing on the Agilent 8890 GC System

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

Method Development for Capillary GC Systems. Slide 1

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Practical Steps in GC Troubleshooting

Hot Injection Adapter Kit - Installation Guide

Liquid Injection Techniques in GC and GC-MS

One-Minute Essential Oils Characterization by Gas Chromatography through Nanovolume Injection

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Technical Procedure for Gas Chromatography (GC-FID)

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

Valving Schemes for the BioLogic Duo-Flow Chromatography System

Agilent SD-1 Purification System ml/min

Agilent Multimode Inlet

HPLC TROUBLESHOOTING GUIDE

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

CHROMATOGRAPHY TIME IN CONVENTIONAL GAS THE FASTEST INJECTION-TO-INJECTION CLARUS 680 GAS CHROMATOGRAPH NEW

Installing a Cool On-Column Inlet

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Application Note. Abstract. Authors. Environmental Analysis

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

Needle OD (mm) Needle ID (mm) Needle Gauge

MET-Biodiesel Capillary GC Columns

Sample Handling Vials

Agilent Multimode Inlet for Gas Chromatography

Typical Gas Chromatographic System

RIVA 2014 COMPLETE YOUR AGILENT TOUR. Better Connections with Agilent. Ken Lynam CSD R&D/Applications Chemist, Wilmington, DE USA.

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Transcription:

Best Selling GC Accessories Liners Ferrules Cool-Lock Nut Septa Syringes Gold Seals 30 % OFF* Expires: September 27, 2013 Mention Offer Code: GACC0913 Any GC Accessories in this brochure First time purchasers only. Limit 5 packs per company.

Cool-Lock Nut ~exclusive~ Avoid burning your fingers again cools with the oven Increased reproducibility locks insertion depth before installation No more Wite-Out, Tipp-Ex, or septa pieces! Quick and Easy! U.S. Patent No. 8,062,516 How to Select a Cool-Lock Nut for your Agilent GC System Decide on The Style of Cool-Lock Nut Needed Short Style (AG0-8319) Long Style (AG0-8320) Recommended for use with standard short Recommend for use with standard long style style ferrules. ferrules. Also, use for both the inlet and detector configurations on Agilent 6890, 5890, and 7890 GC systems (Short ferrules provide a robust seal and typically remain tight over time). 1 2 Determine How Many Cool-Lock Nuts Needed Per System Detector Number of Nuts MS 1 FID, ECD, Other 2 Cool-Lock GC Capillary Nut For Agilent GC Systems* Part No. Description Unit Price AG0-8319 Cool-Lock GC Capillary Nut For Use With ea $ 79 Short-Style Ferrules AG0-8320 Cool-Lock GC Capillary Nut For Use With Long-Style Ferrules ea 79 * Guaranteed fit for Aglilent 5850, 5890, 6850, 6890, 7890 GC systems Ferrules Cool-Lock Nut Installation Gauge for Agilent GC Systems Part No. Description Unit Price AG0-8349 Cool-Lock Nut Installation Gauge ea $ 73 Long Ferrules Composition GC Column ID (mm) Ferrule ID (mm) Mfr. No.* Part No. Preconditioned Unit Price 0.10-0.25 0.4 20200 AG0-4698 N 10/pk $ 41 100 % Graphite 0.28-0.35 0.5 72635 AG0-4701 N 10/pk 41 0.45-0.53 0.8 82636 AG0-4704 N 10/pk 41 0.10-0.25 0.4 07663 5062-3508 AG0-8677 Y 10/pk 44 85 % Vespel / 072654 0.28-0.35 0.5 15 % Graphite 5062-3506 AG0-8678 Y 10/pk 44 0.45-0.53 0.8 072655 5062-3538 AG0-8679 Y 10/pk 45 0.10-0.25 0.4 20211 AG0-4707 10/pk 45 Y 20229 AG0-4708 50/pk 157 60 % Vespel / 20212 AG0-4710 10/pk 45 40 % Graphite 0.28-0.35 0.5 Y 20231 AG0-4711 50/pk 157 0.45-0.53 0.8 20213 AG0-4713 Y 10/pk 45 * Similiar to but not always an exact equivalent to the original manufacturer's product. Cool-Lock Nut and gauge also available for Shimadzu 2010 and 2014 GC Systems. Please inquire or visit www.phenomenex.com/gc Short Ferrules Composition GC Column ID (mm) Ferrule ID (mm) Mfr. No.* Part No. Preconditioned Unit Price 0.10-0.25 0.4 500-2114 AG0-8929 N 10/pk $ 42 100 % Graphite 85 % Vespel / 15 % Graphite 0.28-0.35 0.5 0.45-0.53 0.8 0.10-0.25 0.4 0.28-0.35 0.5 0.40-0.53 0.8 * Similiar to but not always an exact equivalent to the original manufacturer's product. 072635 5080-8853 AG0-7513 Y 10/pk 43 072636 500-2118 AG0-8676 Y 10/pk 35 5181-3323 AG0-7318 N 10/pk 69 5181-3322 AG0-7321 Y 10/pk 69 5062-3514 AG0-7319 N 10/pk 63 5062-3513 AG0-7322 Y 10/pk 63 5062-3512 AG0-7320 N 10/pk 63 5062-3511 AG0-7323 Y 10/pk 63 All ferrules are 1 /16 in. Preconditioned for lower bleed. All Vespel containing ferrules should be pre-shrunk in an oven at 250 C for at least 4 hours prior to use. 2

GC Inlet Liners Column Installs This End for Agilent Technologies (HP) GC Systems Liners Description Benefits / Uses GC Model No. Split / Splitless Liner with wool Splitless Single Taper Liner with wool Cup Splitter / Split Liner* Cup Splitter / Split Liner with wool* Splitless Liner Straight Liner Splitless Straight Liner* Split / Splitless, Single Taper Liner Split / Splitless, Single Taper Liner* Direct Liner Split / Splitless, Recessed Gooseneck Liner with wool Single Taper Direct Connect with Side Hole (top) Single Taper Direct Connect with Side Hole (bottom) Split Liner with wool Split / Splitless, Double Taper/Gooseneck Liner Split / Splitless FocusLiner with wool Split / Splitless, FocusLiner Single Taper with wool Split / Splitless, Single Taper with wool High and low MW compounds and large volume injections Large volume injection of dirty Small injection, trace Small injection, trace Injection < 1 μl or Purge & Trap/ Headspace Large injection of dirty Great recovery and linearity for trace of active compounds Great recovery and linearity for trace of active compounds General use or dirty of active compounds Trace of dirty General use or dirty General use or dirty Dimensions ID x L x OD (mm) Units Mfr. No.** Part No. Unit Price 4 x 78.5 x 6.45 ea Supelco 2 x 78.5 x 6.45 not deactivated ea 4 x 78.5 x 6.45 ea 2 x 78.5 x 6.45 ea 1.5 x 78.5 x 6.45 ea 4 x 78.5 x 6.45 ea ea 19251-60540 5183-4691 5183-4692 5062-3587 5183-4693 5183-4694 HP 18740-80190 5183-4699 5183-4700 18740-60840 5183-4697 5183-4698 2048205 HP 18740-80220 5181-8818 5183-4703 5183-4704 210-3003 210-3003-5 5181-3316 5183-4695 5183-4696 18740-80200 5183-4709 5183-4710 19251-60540 5183-4647 5183-4691 5183-4692 G1544-80730 20782 20783 22405 22406 22407 20709 20710 20712 20713 20714 20772 20773 20774 20798 20799 20800 20795 20796 20797 20972 20973 22408 22409 22410 G1544 21054 21055 20998 5183-4647 5183-4701 5183-4702 5181-3315 5183-4705 5183-4706 20756 20771 21032 21033 20784 20785 20786 210-4004 21022 21023 20979 5183-4711 5183-4712 5183-4713 20994 20995 20996 AG0-4655 AG0-4656 AG0-4657 AG0-4658 AG0-4647 AG0-4648 AG0-7853 AG0-4649 AG0-4650 AG0-4651 AG0-4652 AG0-7516 AG0-7640 AG0-4653 AG0-4654 AG0-4659 AG0-4660 AG0-4661 AG0-4662 AG0-7850 $ 99 329 134 525 195 799 185 109 389 84 315 119 450 139 549 94 375 125 455 299 AG0-7851 299 AG0-8172 AG0-8173 AG0-7515 AG0-7582 AG0-4680 AG0-7514 149 155 94 355 139 565 4 x 78.5 x 6.3 092003 22406 AG0-8175 129 Double Gooseneck with Bottom Hole Splitless, Single Taper Liner with wool Great recovery and linearity for trace of active compounds 4 x 78.5 x 6.3 G1544-80700 20989 20954 5183-4693 5183-4694 AG0-8430 285 AG0-8499 AG0-9170 109 495 Split / Splitless Liner with wool 4 x 78.5 x 6.3 5183-4691 5183-4692 AG0-8653 AG0-8654 83 335 Split / Splitless Liner with wool Small injection, trace of dirty 2.3 x 78.5 x 6.3 210-4022 AG0-8379 135 Note: Large injection 2 μl. Small injection 2 μl *Liner is not deactivated ** but not always an exact equivalent to the original manufacturer s product. Injection port inlet liners also available for PerkinElmer, Shimadzu, Thermo Scientific and Varian GC Systems. Please inquire or visit phenomenex.com 3

Septa 1 2 3 How to choose the correct Septa Find the correct size for your GC inlet (See Septa Sizes chart) Choose the appropriate temperature stability at or above the maximum temperature of your inlet If using narrow gauge needles, select an option with GuideRight hole Septa Sizes by GC Instrument Manufacturer Instrument Model Septa Diameter Agilent (HP) 5850, 5880, 5890, 6850, 6890, 7890 7/16 in. (11 mm) 5700 series, 5880A 3/8 in. (9.5 mm) Antek All 3/8 in. (9.5 mm) Thermo Scientific Finnigan 9600 3/8 in. (9.5 mm) GOW-MAC All 3/8 in. (9.5 mm) HNU Portable GC 3/8 in. (9.5 mm) PerkinElmer Sigma series, 900, 9900, 8000, Autosampler 7/16 in. (11 mm) Shimadzu All plug Tracor 540 550, 560 11/24 in. (11.5 mm) 3/8 in. (9.5 mm) Varian Packed column injectors SPI 3700 / Vista capillary injectors Saturn GC/MS 3/8 in. (9.5 mm) 7/16 in. (11 mm) 7/16 in. (11 mm) or 11/24 in. (11.5 mm) Temperature Type Stability Durability PhenoGrey -250 250 ºC Best PhenoBlue -300 350 ºC Better Available with GuideRight hole PhenoRed -400 400 ºC Good 4 PhenoGreen -400 400 ºC Good 4 GuideRight Injection Hole Septa Part No. Description Unit Price Part No. Description Unit Price PhenoGreen 3 /8 in. (9.5 mm) Diameter 400 C PhenoGreen 7 /16 in. (11 mm) Diameter 400 C AG0-7874 PhenoGreen 400 Injector Septa 50/pk $ 73 AG0-7875 PhenoGreen 400 Injector Septa 50/pk 73 PhenoRed 3 /8 in. (9.5 mm) Diameter 400 C PhenoRed 7 /16 in. (11 mm) Diameter 400 C AG0-7916 PhenoRed 400 Injector Septa 50/pk 73 AG0-7917 PhenoRed 400 Injector Septa 50/pk 79 Silicone Rubber Septa Part No. Description Unit Price Part No. Description Unit Price PhenoGrey 3/8 in. (9.5 mm) Diameter PhenoGrey 7/16 in. (11 mm) Diameter AG0-4686 PhenoGrey-250 Injector Septa 50/pk $ 45 AG0-4692 PhenoGrey-250 Injector Septa 50/pk $ 51 AG0-4687 PhenoGrey-250 Injector Septa 100/pk 73 AG0-4693 PhenoGrey-250 Injector Septa 100/pk 73 PhenoBlue 3/8 in. (9.5 mm) Diameter PhenoBlue 7/16 in. (11 mm) Diameter AG0-4688 PhenoBlue-300 Injector Septa 50/pk 73 AG0-4694 PhenoBlue-300 Injector Septa 50/pk 73 AG0-4689 PhenoBlue-300 Injector Septa 100/pk 119 AG0-4695 PhenoBlue-300 Injector Septa 100/pk 119 PhenoRed 3/8 in. (9.5 mm) Diameter PhenoRed 7/16 in. (11 mm) Diameter AG0-4690 PhenoRed-400 Injector Septa 50/pk 73 AG0-4696 PhenoRed-400 Injector Septa 50/pk 73 AG0-4691 PhenoRed-400 Injector Septa 100/pk 134 AG0-4697 PhenoRed-400 Injector Septa 100/pk 145 PhenoGreen 3/8 in. (9.5 mm) Diameter PhenoGreen 7/16 in. (11 mm) Diameter AG0-8572 PhenoGreen-400 Injector Septa 50/pk 73 AG0-8573 PhenoGreen-400 Injector Septa 50/pk 73 Shimadzu Injector Septa Plug Part No. Description Unit Price AG0-7517 Septa Plug for Shimadzu Injectors 50/pk $ 84 (9A, 14, 15A, 16, 17A, 2010) Rated to 350 C AG0-8802 Septa BTO Plugs, Rated to 400 C 50/pk 75 4

Inlet Base Seals ~exclusive~ Easy Seals for Agilent GCs Soft surface eliminates need for washer Minimal torque required to form tight seal Increase column lifetime with tight seal Easy, Washerless, and Leak-Tight! s Easy Seals make a tight seal without the need to apply high torque. These seals eliminate the need to use a washer and reduce breakdown and adsorption of active compounds, such as acids, bases, and pesticides. Easy Seals Part No. Description Unit Price Standard, single groove for splitless applications, 0.8 mm dia. inlet hole AG0-8619 Easy Seal Inlet Base Seal, Gold Plated, for Agilent GCs 2/pk $ 56 AG0-8620 Easy Seal Inlet Base Seal, Gold Plated, for Agilent GCs 10/pk 255 Gold Inlet Base Seals for Agilent GCs Traps non-volatile residues, septum fragments, and other contaminants Exceptional inertness Gold Inlet Base Seals Part No. Description Mfr. No.* Unit Price Standard, single groove for splitless applications, 0.8 mm dia. inlet hole AG0-7518 Gold Inlet Base Seal, splitless (single groove), 0.8 mm 18740-20885 2/pk $ 79 AG0-7519 Gold Inlet Base Seal, splitless (single groove), 0.8 mm 18740-20885 10/pk 315 High Split Flow, cross groove for split applications, 0.8 mm dia. inlet hole AG0-7520 Gold Inlet Base Seal, split (double groove/cross), 0.8 mm 5182-9652 2/pk 83 AG0-7521 Gold Inlet Base Seal, split (double groove/cross), 0.8 mm 5182-9652 10/pk 315 Standard, single groove for splitless applications, 1.2 mm dia. inlet hole AG0-8581 Gold Inlet Base Seal, splitless (single groove), 1.2 mm 21305 2/pk 79 AG0-8582 Gold Inlet Base Seal, splitless (single groove), 1.2 mm 21306 10/pk 315 High Split Flow, cross groove for split applications, 1.2 mm dia. inlet hole AG0-8583 Gold Inlet Base Seal, split (double groove/cross), 1.2 mm 21009 2/pk 84 AG0-8584 Gold Inlet Base Seal, split (double groove/cross), 1.2 mm 21010 10/pk 319 Replacement Inlet Seal Washers AG0-8397 Inlet Seal Washers Gold Plated, for Agilent GC injection port 12/pk 53 Stainless Steel Inlet Base Seals for Agilent GCs Lower cost alternative Ideal for hydrocarbon Due to different replacement frequencies, inlet seal washers are sold separately from inlet base seals. Stainless Steel Inlet Base Seals Part No. Description Mfr. No.* Unit Price Standard, single groove for splitless applications, 0.8 mm dia. inlet hole AG0-8393 Stainless Steel Inlet Base Seal, splitless (single groove), 0.8 mm 18740-20880 2/pk $ 48 AG0-8394 Stainless Steel Inlet Base Seal, splitless (single groove), 0.8 mm 18740-20880 10/pk 200 High Split Flow, cross groove for split applications, 0.8 mm dia. inlet hole AG0-8395 Stainless Steel Inlet Base Seal, split (double groove/cross), 0.8 mm 2/pk 59 AG0-8396 Stainless Steel Inlet Base Seal, split (double groove/cross), 0.8 mm 10/pk 210 Replacement Inlet Seal Washers AG0-7522 Inlet Seal Washers, Stainless Steel, for Agilent GC injection port 5061-5869 12/pk 37 * but not always an exact equivalent to the original manufacturer's product. 5

Syringes Autosampler Syringes Syringes for Agilent GC 7673, 7683, and 6850 Autosampler Systems Hamilton Syringes Volume (μl) / Connection Gauge Length Style Model Mfr. No Microliter Syringes 5 ASRN 23s 1.71 in. Agilent 75 87957 24793 ea AS0-8834 $ 69 5 ASN 23s 1.71 in. Agilent 75 87987 9301-0892 20168 ea AS0-4386 69 5 ASN 23s 1.71 in. Agilent 75 87990 20170 6/pk AS0-7641 359 5 ASRN 26s 1.71 in. Agilent 75 87958 24792 ea AS0-8833 79 5 ASN 26s 1.71 in. Agilent 75 87989 21230 6/pk AS0-8683 385 5 ASRN 23s-26s 1.71 in. Agilent 75 87959 21211 ea AS0-8831 82 5 ASN 23s-26s 1.71 in. Agilent 75 87993 24593 ea AS0-8380 75 10 ASRN 23s 1.71 in. Agilent 701 80357 24795 ea AS0-8836 55 10 ASN 23s 1.71 in. Agilent 701 80387 9301-0713 20167 ea AS0-4387 46 10 ASN 23s 1.71 in. Agilent 701 80390 9301-0725 20169 6/pk AS0-4388 240 10 ASRN 23s 1.71 in. Agilent 701 80358 24794 ea AS0-8835 54 10 ASN 26s 1.71 in. Agilent 701 80389 24599 6/pk AS0-4389 240 10 ASN 23s-26s 1.71 in. Agilent 701 80393 24596 ea AS0-8684 47 10 ASRN 23s-26s 1.71 in. Agilent 701 80359 21213 ea AS0-8832 56 10 ASN 23s-26s 1.71 in. Agilent 701 80391 24600 6/pk AS0-8685 249 Teflon Tip Gastight Syringes 5 ASN 23s 1.71 in. Agilent 175 80074 24893 ea AS0-8686 54 10 ASN 23s-26s 1.71 in. Agilent 701 80079 n/a ea AS0-8837 54 SGE Syringes Volume / (μl) Connection Gauge Length Style Model Mfr. No Microliter Syringes 5 F 23 42 mm Cone 5F-HP-0.63C 001810 24781 ea AS0-8839 $ 72 5 F 23 42 mm Cone SK-5F-HP-0.63 001814 24783 6/pk AS0-8687 385 5 R 23 42 mm Cone 5R-HP-0.63C 001815 24793 ea AS0-8843 72 5 F 26 42 mm Cone 5F-HP-0.47C 001800 24780 ea AS0-8838 62 5 F 26 42 mm Cone SK-5F-HP-0.47 001804 24782 6/pk AS0-8688 409 5 R 26 42 mm Cone 5R-HP-0.47C 001805 24792 ea AS0-8842 83 5 F 23s-26s 42 mm Cone SK-5F-HP-0.63/0.47 001822 21214 6/pk AS0-8689 355 5 F 23-26 42 mm Cone 5F-HP-0.63*0.47 001821 5181-1273 21210 ea AS0-5208 69 5 R 23-26 42 mm Cone 5R-HP-0.63/0.47C 001825 21211 ea AS0-8840 86 10 F 26 42 mm Cone SK-10F-HP-47 002804 24786 6/pk AS0-7637 245 10 R 23 42 mm Cone 10RHP-0.63 002815 24795 ea AS0-8690 73 10 F 23 42 mm Cone 10F-HP-0.63 002810 24785 ea AS0-8691 51 10 F 26 42 mm Cone SK-10F-HP-0.47 002804 24786 6/pk AS0-7637 245 10 R 26 42 mm Cone 10R-HP-0.47C 002805 24794 ea AS0-8844 56 10 F 23 42 mm Cone SK-10F-HP-0.63 002814 24787 6/pk AS0-8692 249 10 F 23s-26s 42 mm Cone 10F-HP-0.63/0.47 002821 21212 ea AS0-8693 51 10 F 23s-26s 42 mm Cone SK-10F-HP-0.63/0.47 002822 21215 6/pk AS0-8694 265 10 R 23-26 42 mm Cone 10R-HP-0.63/0.47C 002825 21213 ea AS0-8841 57 Teflon Tip Gastight Syringes 10 F 23 42 mm Cone HF-HP-GT-0.63 002812 24789 ea AS0-8695 63 10 R 23-26 42 mm Cone 10R-HP-GT-0.63/0.47 002829 21220 ea AS0-8696 75 10 F 23-26 42 mm Cone 10F-HP-GT-0.63/0.47 002826 5181-1267 ea AS0-5209 62 10 F 23-26 42 mm Cone SK10F-HP-FT-0.63/0.47 002827 5181-3361 6/pk AS0-5210 345 Syringes for Varian 8000 Series GC System SGE Syringes Volume (μl) / Connection Gauge Length Style Model Mfr. No Microliter Syringes 10 R 25 53 mm Side Hole 10R-VA8X-II 002924 24852 ea AS0-8699 $ 235 10 F 26 50 mm Cone 10F-C/F-5/0.47C 002980 24922 ea AS0-8700 42 10 F 26 50 mm Bevel 10F-VA8400-5/0.47 002950 21202 ea AS0-8701 35 * but not always an exact equivalent to the original manufacturer's product. 6

Syringes (cont d) Manual Syringes Hamilton Manual Syringes Syringes Volume (μl) / Connection Gauge Length Style Model Mfr. No Microvolume Syringes 5 N 26s 2 in./51 mm 2 75N 87900 24938 ea AS0-4390 $ 42 5 RN 26s 2 in./51 mm 2 75RN 87930 24617 ea AS0-8702 57 10 N 26s 2 in./51 mm 2 701N 80300 20174 ea AS0-0077 30 10 N 26s 2 in./51 mm 2 701N 80366 20175 6/pk AS0-0016 141 10 RN 26s 2 in./51 mm 2 701RN 80330 24530 ea AS0-0100 51 25 N 22s 2 in./51 mm 2 702N 80400 24531 ea AS0-0078 38 10 N 26s 2 in./51 mm 5 701NPT5 80339 24967 ea AS0-0094 58 Positive Displacement Syringes 0.5 KH 25 2.75 in./70 mm 2 7000.5 86259 24545 ea AS0-8715 91 1.0 KH 22 2.75 in./70 mm 2 7101 86211 24549 ea AS0-8716 73 1.0 KH 25s 2.75 in./70 mm 2 7001 80135 24547 ea AS0-1918 74 1.0 KH 25s 2.75 in./70 mm 3 7001 80100 24548 ea AS0-8717 74 2.0 KH 25 2.75 in./70 mm 2 7002 88411 24551 ea AS0-8718 89 5.0 KH 24 2.75 in./70 mm 2 7105 88011 24555 ea AS0-8719 82 Teflon Tip Gastight Syringes 10 N 26s 2 in./51 mm 2 1701 80000 24557 ea AS0-4391 45 10 RN 26s 2 in./51 mm 2 1701 80030 24558 ea AS0-1898 58 25 N 22s 2 in./51 mm 2 1702 80200 24559 ea AS0-8720 57 25 RN 22s 2 in./51 mm 2 1702 80230 24560 ea AS0-1899 58 50 N 22s 2 in./51 mm 2 1705 80900 24561 ea AS0-0061 51 50 RN 22s 2 in./51 mm 2 1705 80930 24562 ea AS0-1900 58 100 N 22s 2 in./51 mm 2 1710 81000 24563 ea AS0-0062 58 100 RN 22s 2 in./51 mm 2 1710 81030 24564 ea AS0-1901 69 250 N 22s 2 in./51 mm 2 1725 81100 24567 ea AS0-0063 58 250 RN 22s 2 in./51 mm 2 1725 81130 24568 ea AS0-1902 63 500 LTN 22 2 in./51 mm 2 1750 81217 24571 ea AS0-0064 58 500 RN 22 2 in./51 mm 2 1750 81230 24572 ea AS0-1903 69 1 ml LTN 22 2 in./51 mm 2 1001 81317 24575 ea AS0-0065 62 1 ml RN 22 2 in./51 mm 2 1001 81330 24576 ea AS0-8721 68 1 ml TLL w/o slots 1001 81320 24578 ea AS0-1907 45 2.5 ml TLL w/o slots 1002 81420 24584 ea AS0-1908 54 2.5 ml RN 22 2 in./51 mm 2 1002 81430 24582 ea AS0-8722 77 2.5 ml N 22 2 in./51 mm 2 1002 81417 24581 ea AS0-8723 57 5 ml TLL w/o slots 1005 81520 20178 ea AS0-8724 67 10 ml TLL w/o slots 1010 81620 20179 ea AS0-1910 79 SGE Syringes Volume (μl) / Connection Gauge Length Style Model Mfr. No Microvolume Syringes 5 F 26 50 mm 2 5F 001000 24700 ea AS0-8725 $ 45 5 R 26 50 mm 2 5R 001050 24701 ea AS0-8726 61 10 F 26 50 mm 2 10F 002000 24702 ea AS0-8727 30 10 R 26 50 mm 2 10R 002050 24703 ea AS0-8729 54 Positive Displacement Syringes 0.5 R 23 70 mm 2 0.5BR-7BV 000311 24771 ea AS0-8737 165 1.0 R 23 70 mm 2 1BR-7BV 000506 24775 ea AS0-8738 82 1.0 R 26 70 mm Cone 1BR-7/0.47 000570 24776 ea AS0-8739 82 5.0 R 23 70 mm 2 5BR-7BV 000803 24779 ea AS0-8740 91 Teflon Tip Gastight Syringes 10 F 26 50 mm 2 10F-GT 002200 24725 ea AS0-8741 40 10 R 26 50 mm 2 10R-GT 002250 24726 ea AS0-8742 61 25 F 25 50 mm 2 25F-GT 003200 24727 ea AS0-8743 50 50 F 25 50 mm 2 50F-GT 004200 24729 ea AS0-8744 50 50 R 25 50 mm 2 50R-GT 004250 24730 ea AS0-8745 61 100 F 25 50 mm 2 100F-GT 005200 24734 ea AS0-8746 59 100 R 25 50 mm 2 100R-GT 005250 24735 ea AS0-8747 63 250 F 25 50 mm 2 250F-GT 006200 24738 ea AS0-8748 57 250 R 25 50 mm 2 250R-GT 006250 24739 ea AS0-8749 63 500 F 25 50 mm 2 500F-GT 007200 24742 ea AS0-8750 57 500 R 25 50 mm 2 500R-GT 007250 24743 ea AS0-8751 63 1 ml RN 23 50 mm Bevel 1MDR-GT 008100 24750 ea AS0-8845 69 1 ml LL 1MDF-LL-GT 008025 24752 ea AS0-0120 73 2.5 ml R 23 50 mm Bevel MDR-GT 008500 ea AS0-8752 82 5 ml LL 5MDR-LL-GT 008760 24757 ea AS0-0121 82 10 ml LL 10MDR-LL-GT 008960 24759 ea AS0-0122 82 25 ml LL 25MDR-LL-GT 009462 24760 ea AS0-8755 185 7

30 % OFF* Expires: September 27, 2013 GC Accessories in this brochure *Terms and conditions apply PRSRT STD U.S. POSTAGE PAID TORRANCE, CA PERMIT NO. 185 Australia t: 02-9428-6444 f: 02-9428-6445 auinfo@phenomenex.com Austria t: 01-319-1301 f: 01-319-1300 anfrage@phenomenex.com Belgium t: 02 503 4015 (French) t: 02 511 8666 (Dutch) f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: (800) 543-3681 f: (310) 328-7768 info@phenomenex.com Denmark t: 4824 8048 f: +45 4810 6265 nordicinfo@phenomenex.com Finland t: 09 4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: 01 30 09 21 10 f: 01 30 09 21 11 franceinfo@phenomenex.com Germany t: 06021-58830-0 f: 06021-58830-11 anfrage@phenomenex.com India t: 040-3012 2400 f: 040-3012 2411 indiainfo@phenomenex.com Ireland t: 01 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: 051 6327511 f: 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: 001-800-844-5226 f: 001-310-328-7768 tecnicomx@phenomenex.com The Netherlands t: 030-2418700 f: 030-2383749 nlinfo@phenomenex.com New Zealand t: 09-4780951 f: 09-4780952 nzinfo@phenomenex.com Norway t: 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Puerto Rico t: (800) 541-HPLC f: (310) 328-7768 info@phenomenex.com Sweden t: 08 611 6950 f: +45 4810 6265 nordicinfo@phenomenex.com United Kingdom t: 01625-501367 f: 01625-501796 ukinfo@phenomenex.com United States t: (310) 212-0555 f: (310) 328-7768 info@phenomenex.com All other countries: Corporate Office USA t: (310) 212-0555 f: (310) 328-7768 info@phenomenex.com BR83400313_us_2 www.phenomenex.com products are available worldwide. For the distributor in your country, contact USA, International Department at international@phenomenex.com Terms and Conditions *This offer is not transferable and is intended for the recipient of this brochure only. Customer must be a first-time purchaser of GC accessories, limit 5 packs per company. Discount offer applies only to GC accessories listed in this brochure. Discount must be specified at time of order and/or appear on the original purchase order, without exception. Subject to Standard Terms and Conditions, which may be viewed at www.phenomenex.com/termsandconditions. Trademarks Cool-Lock, Easy Seals, GuideRight, PhenoGrey, PhenoBlue, PhenoRed, and PhenoGreen are trademarks of. Wite-Out is a registered trademark of BIC Corp. USA Inc. Tipp- Ex is a registered trademark of Tipp-Ex GmbH & Co KG. SGE is a registered trademark and FocusLiner is a trademark of SGE. Vespel and Teflon are registered trademarks of E.I. Du Pont de Nemours and Co. Varian is a registered trademark of Varian Medical Systems Technologies, Inc. Agilent and Agilent Technologies are registered trademarks of Agilent Technologies, Inc. Shimadzu is a registered trademark of Shimadzu Corporation. Septa BTO is a registered trademark of Chromatography Research Supplies, Inc. Hamilton and Gastight are registered trademarks of Hamilton Co. Cool-Lock Nut is patented by. U.S. Patent No. 8,062,516 2013, Inc. All rights reserved. 411 Madrid Avenue Torrance, CA 90501-1430 USA