PK Installation Instructions for the 2CPS Series Cable Pull Switch Without Broken Cable Detection ISSUE 3. Sensing and Control

Similar documents
EQUIVALENT BASIC CIRCUIT

VL Series. General Purpose Compact Limit Switches. Sensing and Control

onlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control

10260S Series Actuators Auto-Manual Switch Replacement Instruction

Installation and Service Instructions for EX Series Explosion-proof Switches

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet

Load Accessories. Test & Measurement Sensors DESCRIPTION TONGUE SHACKLE FEATURES PULL PLATE FEATURES YOKE SHACKLE FEATURES LOAD BUTTON FEATURES

Installation Instructions for the ISSUE 2 Explosion-proof Limit Switches LSX Series PK 81181


11280A HercuLine Series Actuator. Specification. Non-Contact Position Sensing and Variable Speed Motor Control. Overview. Features. Actuator Operation

MICRO SWITCH Compact Limit Switches NGC Series Issue 7. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

LED SEMI-FLUSHMOUNT CEILING FIXTURE

MICRO SWITCH Compact Limit Switches NGC Series Issue 9. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION

Microcontroller Unit (MCU) LCD Hour Meters/Counters. LM Series. Datasheet

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Safety rope switches with reset for emergency stop

F-Series General Specifications

LK Position Switches TECHNICAL DATASHEET.

MICRO SWITCH Compact Limit Switches NGC Series Issue 8. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

4-LIGHT VANITY FITTER

MICRO SWITCH Weather-Sealed, Explosion-Proof Switches. CX Series. Datasheet

Cable (Rope) Pull Switches Lifeline 4

Safety rope switch with reset for emergency stop

Safety rope switch without reset for simple stop

Motorized Tempering Valves with Transformers for

Speed Sensors Line Guide

Switches with manual reset

F3S-TGR-KHL1/-KHL3/-KHL3R

Mid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106

HercuLine 2000 Series Gear Kit Replacement Instructions

ZB0050 / ZB0051 ZB0070 / ZB0071

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page

- Wiring Brochure Universal Reset Module 422

Series 9210 High Performance Butterfly Valves for ANSI

Compact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

CAMBELT TENSION GAUGE

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation

The Da-Lite Difference.

SG-B1 SERIES / SG-A1 SERIES

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation

THE 4481 ADJUSTABLE TIMED OUTPUT MACHINE CONTROL

EN REV.

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

Honeywell. Series 9130 Mixing/Diverting Seated 3-Way Valves for ANSI DIN/BS 4504 PN10-PN40

Active Controlled Cooling System

Applications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

1) ALTERNATOR REMOVAL:

2-Way Motorized Valves

- Wiring Brochure Universal Reset Module 422e

Position switches FR series

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

MICRO SWITCH INSTALLATION SHEET

Edison single-phase capacitor switch

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

Heavy Duty Industrial Foot Switches

General purpose relays 6-10 A

Sequence of Operation. Installation. Commissioning. Testing and replacement of dampers and actuators. Troubleshooting. Maintenance

the Interactive Catalog

Miniature Circuit Breaker

EZ-LIGHT Indicators 4-Color, Multi-Function

Powers TM Controls EA 338 Electronic Actuator

580RK SERVICE GUIDELINES For coupling models: 580 & 580J

M7410E SMALL MODULATING LINEAR VALVE ACTUATOR

SENTRON Switching and Protection Devices Switch Disconnectors

M7410E SMALL MODULATING LINEAR VALVE ACTUATOR

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

CRD610 Automatic Fitting Inserter

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Safety Sentry Electronic Breakaway Switch

Position switches FR series

MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

LED FLUSHMOUNT CEILING FIXTURES

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

G7150D, 3-Way, Diverting Flanged Globe Valve

Installation Instructions: K-Safe-T-Drift

Rope safety switches with reset for emergency stop

P70, P72, and P170 Controls for Low Pressure Applications

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

the Interactive Catalog

The Da-Lite Difference.

LED FLUSHMOUNT CEILING FIXTURES (SET OF 4)

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

McCANNA Actuation Systems B

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Service/Installation Manual Full Wall Slide Systems

Safety Limit Switch

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Transcription:

ISSUE 3 Installation Instructions for the 2PS Series able Pull Switch Without roken able Detection PK 80169 WRNING IF USED IN PPLITIONS ONERNING HUMN SFETY Only use N direct opening ( positive opening / positive break ) contacts, identified by the symbol. Do NOT use flexible/adjustable actuators. Only use actuators designed for safety applications. Do NOT defeat, tamper, remove, or bypass this switch. Hazardous voltage, disconnect power before servicing Strictly adhere to all installation and maintenance instructions. onsult with local safety agencies and their requirements when designing a machinecontrol link, interface and all control elements that affect safety. WRNING IMPROPER USE Use the 2PS able Pull Switch Without roken able Detection in stop applications only. WRNING IMPROPER SYSTEM PERFORMNE The 2PS able Pull Switch Without roken able Detection provides only the front end switching/sensing function. The machine, its external machine interfaces, and the safety monitoring of the machine and its interfaces, are the responsibility of the machine safety control system. The user is SOLELY RESPONSILE for determining the appropriate level of risk. The 2PS able Pull Switch Without roken able Detection must be installed in a fashion that complies with all codes and standards that are applicable to the particular application of the device. EN 1050 and NSI TR3 Risk ssessment and Risk Reduction provide assistance on how to perform risk assessment. GENERL INFORMTION The 2PS able Pull Switch Without roken able Detection is available in either single actuator or dual actuator versions. The maximum cable length in a single direction is 76 m [250 ft] for a combined length of 152 m [500 ft] in dual directions. The direct acting switch contacts are held closed when the reset knob is set to. When the actuating cable is pulled, a cam positively opens the N (Normally losed) switch contacts. The snap action, trip operation causes the switch contacts to change state and mechanically latch almost simultaneously when the cable is pulled. The N switch contacts remain open until the 2PS able Pull Switch Without roken able Detection is reset by properly tensioning the cable and manually rotating the reset knob. When the direct acting switch contacts open, the auxiliary contacts also actuate (open contacts close and closed contacts open). The auxiliary contacts are electrically isolated from the direct acting switch contacts. These NO (Normally Open) contacts may be used for monitoring or signaling. removable contact block version is available for robust and easy termination. ccessory packets are available separately (see Table 2 on page 4). STEP 1: MOUNT, WIRE ND SEL SWITH WRNING IMPROPER OPERTION Locate the 2PS such that the installed cable is visible from the 2PS reset OR inspect the length of the cable whenever a stop is signaled. Ensure no barriers or physical obstructions prevent the operator from actuating the 2PS able Pull Switch Without roken able Detection.. Refer to pages 3-6 for: Specifications (Table 1). ccessories available separately (Table 2). Wiring configurations and travel distances (Figure 1). Mounting dimensions (Figure 2). Installation drawings (Figures 3, 4, 5).. Mount switch using four M6, 1/4-28 UNF or 1/4-20 UN screws or bolts. Torque: M6 to 6,1 N m 7,5 N m [54 in lb 66 in lb]. 1/4-28 UNF to 8,6 N m 10,4 N m [76 in lb 92 in lb]. 1/4-20 UN to 7,3 N m 9,0 N m [65 in lb 79 in lb].. Refer to the circuit diagram on the switch cover. The diagram depicts the switch contacts when the cable(s) is (are) at proper tension and the reset knob is in the position. D. Remove the cover plate. Sensing and ontrol

2PS Without roken able Detection ISSUE 3 PK 80169 E. Wire the switch (use 90 [194 F] wire when the ambient temperature is over 75 [167 F]): Standard wiring version: onnect 0,75 mm 2 1,5 mm 2 (18 WG 16 WG) stranded wire or 0,75 mm 2 2,5 mm 2 (18 WG 14 WG) solid wire to the terminals. Torque: Switch terminal screws to 0,8 N m 1,0 N m [7 in lb 9 in lb]. Ground screw to 1,0 N m 1,8 N m [9 in lb 16 in lb]. Heavy duty wiring removable contact block version: onnect 3,5 mm 2 (12 WG) or smaller stranded or solid wire to the terminals. Torque: Switch terminal screws and ground screw to 1,0 N m 1,8 N m [9 in lb 16 in lb]. F. OPTIONL: Wire the LED indicator. Wrap the wire clockwise around the terminal screws. Ensure all wire strands are secured under the screw heads. Torque the terminal screws to 0,8 N m 1,0 N m [7 in lb 9 in lb]. For dc indicators, ensure the positive lead wire is attached to the terminal with the + sign. (There is no polarity requirement for ac indicators.) G. Seal the conduit opening according to the instructions in PK 80112 (included). H. Reassemble the cover plate. Torque the cover screws to 1,5 N m [13 in lb]. STEP 2: INSTLL J-HOOK TURNUKLE ND TUTING LE. Ensure you have the following: Red plastic-coated aircraft cable 3,18 mm [1/8 in] diameter to 4,76 mm [3/16 in] diameter in desired length, not to exceed 76 m [250 ft] per each actuator. J-hook turnbuckle with locknuts. Thimbles to fit all terminations. able clamps to fit all terminations.. ttach the hook end of the J-hook turnbuckle to the actuator.. ttach the eye end of the J-hook turnbuckle to the cable using one thimble and one cable clamp by fitting the cable in the thimble groove and placing the cable clamp as close to the thimble as possible. D. Tighten the cable clamp according to the manufacturer s instructions. (The torque for the cable clamp in the accessory packet is 7,3 N m 9,0 N m [65 in lb 79 in lb].) NOTIE If improved cable visibility is needed, install labels, markers or flags to the cable or adjacent to the cable. STEP 3: INSTLL LE SUPPORTS (EYEOLTS) WRNING IMPROPER OPERTION Do not allow excessive side loads to occur that could bend the switch actuator shaft so as to defeat the broken cable shutdown. Failure to comply with these instructions could NOTIE The first cable support should be in line with, and no farther than, 0,46 m [18 in] from the end of the actuator shaft. When changing the actuating cable direction, i.e., around a corner, ensure the cable runs freely through a pulley or cable supports.. Ensure you have cable supports to fit the cable.. Install a cable support as close to the end of the actuator shaft as possible without interfering with the switch operation.. Install the cable supports at intervals of no greater than 2,4 m [8 ft] along the cable span. D. Thread the cable through the cable supports. STEP 4: SEURE THE LE TO FIXED SUPPORT. Ensure you have the following: Thimbles to fit all terminations. able supports to fit the cable. Fixed support to fit all terminations.. ttach the cable end to a fixed support in the same manner as Steps 2. and 2.D. STEP 5: DJUST LE TENSION. Tighten the turnbuckle until the cable is at the desired tension. Ensure that the cable is tight enough so that the J-hook turnbuckle can t disengage.. Tighten the turnbuckle locknuts.. Periodically check and adjust the cable tension. STEP 6: VERIFY INSTLLTION Y PERFORMING FUNTIONL TESTS UTION SWITH DMGE Do not attempt to rotate the reset knob from to unless the switch is under proper tension. Failure to comply with these instructions may result in product damage.. Ensure the cable actuates freely. Ensure the installation elements are not subject to mechanical damage due to positioning or location.. Turn the reset knob to.. PULLED LE STTE: Pull the cable. Ensure the reset knob rotates to. D. Turn the reset knob to. 2 Honeywell Sensing and ontrol

2PS Without roken able Detection ISSUE 3 PK 80169 TLE 1 Designation and Rated Operational urrent Ie () at Rated Operational Voltage Ue (V) Utilization ategory 24 V 120 V 240 V 15 300 -- 6 3 D13 Q300 2,8 0,55 0,27 Rated thermal current (Ith) 10 Rated impulse withstand (Uimp) 2500 V Usable gold-plated current 10 μ to 10 m, 1 V to 50 V Sealing IP67; NEM 1, 4, 12, 13 Operating temperature range -40 to 80 [-40 F to 176 F] Shock 15 g Vibration 10 Hz - 500 Hz, 5 g Mechanical life 1,000,000 operations omplies with: Low Voltage Directive 73/23/EE, as amended by directive 93/68/EE. Machinery Directive 98/37/EE only as the directives relate to the components being used in a safety function. IE/EN60947-1, IE/EN60947-5-1. FIGURE 1 mm/[in] 2N/2NO 13 14 13 14 13-14 13-14 0 *9,9 (0.39) 3,8 (0.15) 7,9 (0.31) (0.50) D 3N/1NO 13 14 11 12 13-14 11-12 0 *9,9 (0.39) 3,8 (0.15) 7,9 (0.31) (0.50) Left switch Right switch Pulled cable D able tension = 178 N [40 lb] ontact closed ontact open * Positive Opening to IE/EN60947-5-1 D Honeywell Sensing and ontrol 3

2PS Without roken able Detection ISSUE 3 PK 80169 FIGURE 2 mm[in] 40,4 [1.60] 67,8 [2.63] 79,8 [3.14] 92,9 [3.66],1 [0.75] 298,45 [11.75] 152,4 [6.00] 52,1 [2.05] [0.50] 18,3 [0.72] 152,4 [6.00] 34,9 [1.38] 104,8 [4.13] 2X 8,9 [0.35] 2X 6,9 [0.27] 81,3 [3.20] 40,5 [1.60] 2X D 2X 6,4 [0.25] 2X 31,75 [1.25] [0.50] 57,2 [2.25] 139,7 [5.50] 2X D 2X 6,9 [0.27] 3X,5 [0.85] 231,9 [9.13] ll drawings are for reference only. Fully extended Optional indicator onduit thread (3 total) D Mounting pad (4 total) TLE 2 Listing LSZ1 LSZ2 LSZ3 LSZ4 LSZ5 LSZ7 LSZT PSZK1 PSZT PS-RKET PSLED24 PSLED120 ccessory (vailable Separately) 7,6 m [25 ft] cable 15,2 m [50 ft] cable 30,5 m [100 ft] cable 45,7 m [150 ft] cable 61,0 m [200 ft] cable 76,2 m [250 ft] cable (2) Thimbles (2) Low-profile duplex cable clamps (1) J-hook turnbuckle with lock nuts (2) Thimbles 2) Low-profile duplex cable clamps (1) J-hook turnbuckle with lock nuts (1) Mounting bracket (1) 24 Vdc multicluster LED (1) 120 Vac multicluster LED (16) Sets of cable supports (16 1/4-20 eye bolts, 32 1/4-20 nuts, 32 flat washers, 16 lock washers) Honeywell Sensing and ontrol 4

2PS Without roken able Detection ISSUE 3 PK 80169 FIGURE 3 mm[in] 2N/2NO M3 #6-32 UN 3N/1NO 11 12 11 12 Standard Wiring Version Ground screw Heavy Duty Wiring Removable ontact lock Version Ground screw FIGURE 4 mm[in] SLK SLK 0,46 m [18 in] maximum 2,4 m [8 ft] maximum 76 m [250 ft] maximum Honeywell Sensing and ontrol 5

2PS Without roken able Detection ISSUE 3 PK 80169 FIGURE 5 mm[in] D D E F G H I J D E J-hook turnbuckle Thimble able clamp able support (eyebolt) Tension indicator line is in center of indicator window left cable is properly tensioned F Reset knob G Tension indicator line is in center of indicator window right cable is properly tensioned H Thimble I able clamp J able WRRNTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. ontact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is uyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest uthorized Distributor, check the Honeywell web site or call: 1-800-537-6945 US 1-800-737-3360 anada 1-815-235-6847 International FX 1-815-235-6545 US INTERNET www.honeywell.com/sensing info.sc@honeywell.com Sensing and ontrol Honeywell 11 West Spring Street Freeport, Illinois 61032 PK 80169-3-EN IL50 NM 1003 Printed in US opyright 2003 Honeywell International Inc. www.honeywell.com/sensing