K63F003UP cam changeover switch - 3-pole A - screw mounting

Similar documents
K50F003UP cam changeover switch - 3-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

XACA871 pendant control station XAC-A - 8 pushbuttons

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XACA871 pendant control station XAC-A - 8 pushbuttons

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

Screw limit switches XRBA and XR2. Catalogue

VW3A4552. Product datasheet Characteristics. Main 1 / 5

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

Limit switches 3. Page 92. Page 92

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

Pendant control stations 6

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Limit Switch - Prewired Type Metal Body

AF40... AF96 3-pole contactors Technical data

Compact plastic limit switches with positive opening mechanism

BSH0553T11A2A AC servo motor BSH N.m rpm - keyed shaft - without brake - IP50

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

BSH1001P31A2A AC servo motor BSH N.m rpm - keyed shaft - without brake - IP65

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Compact plastic limit switches with positive opening mechanism

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Square D General Purpose Relays

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

BSH0553P11A1A AC servo motor BSH N.m rpm - keyed shaft - without brake - IP50

Modular contactors and relays

BSH0702P12A2A AC servo motor BSH N.m rpm - keyed shaft - without brake - IP50

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Limit Switches - Limit Type (PS21L) Metal Body IP66

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Components for safety applications

Vistop TM isolating switches 63 to 160A

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Limit Switches - Limit Type Plastic Body IP65

PRODUCT SPECIFICATION. Foot Switches. Series.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Limit Switch

3 - Protection components Motor circuit-breakers

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Safety detection solutions


cor Long Run Experience

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

MANUALLY OPERATED CHANGEOVER SWITCHES

2NC (slow-action) Direct. Model. opening

Rotary limit switches FCR FGR series

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

D4NH CSM_D4NH_DS_E_7_1

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

For Info: Phone: Fax:

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

SWITCHGEAR. 4G cam switches

Limit Switches - Limit Type Plastic Body IP65

Safety Limit Switch

Pendant control stations

Cylindrical fuse-link

Cat N 3. OVERALL DIMENSIONS

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

250V 24V, 30V, 48V, 100 / 110V, 125V, 200 / 220V DC. 11mA. 2,000V AC / 1min. ±4.5kV, 3 times for each pole (1.2 / 50μs)

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Transcription:

Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam switch head type Type of operator Rotary handle padlocking Presentation of legend Cam switch function Return Switching angle 60 Off position Poles description Harmony K Complete cam switch K63 63 A Front mounting 4 holes With front plate 64 x 64 mm Black handle Without With metallic legend, 1-0 - 2 black marking Changeover switch Without With Off position 3P Switching positions Left: 0-300 Right: 0-60 IP degree of protection IP40 conforming to NF C 20-010 IP40 conforming to IEC 529 [Ui] rated insulation voltage 690 V degree of pollution 3 conforming to IEC 60947-1 690 V degree of pollution 3 conforming to EN 60947-1 Short-circuit current Short circuit protection 10000 A 80 A by cartridge fuse, type gg [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 947-1 6 kv conforming to EN 947-1 Contacts operation Positive opening Electrical connection Tightening torque Switching capacity in ma Mechanical durability CAD overall width Slow-break With Captive screw clamp terminals solid, 2 x 16 mm² Captive screw clamp terminals flexible, 2 x 10 mm² 2.5 N.m 63000 ma DC at 95 V 2 contact(s) for resistive load (T = 1 ms) 63000 ma DC at 70 V 3 contact(s) for resistive load (T = 1 ms) 63000 ma DC at 70 V 3 contact(s) for inductive load (T = 50 ms) 63000 ma DC at 48 V 2 contact(s) for resistive load (T = 1 ms) 63000 ma DC at 48 V 2 contact(s) for inductive load (T = 50 ms) 63000 ma DC at 48 V 1 contact(s) for resistive load (T = 1 ms) 63000 ma DC at 24 V 1 contact(s) for resistive load (T = 1 ms) 63000 ma DC at 24 V 1 contact(s) for inductive load (T = 50 ms) 63000 ma DC at 140 V 3 contact(s) for resistive load (T = 1 ms) 55000 ma DC at 90 V 3 contact(s) for inductive load (T = 50 ms) 55000 ma DC at 60 V 2 contact(s) for inductive load (T = 50 ms) 55000 ma DC at 30 V 1 contact(s) for inductive load (T = 50 ms) 30000 ma DC at 60 V 1 contact(s) for resistive load (T = 1 ms) 30000 ma DC at 180 V 3 contact(s) for resistive load (T = 1 ms) 30000 ma DC at 120 V 2 contact(s) for resistive load (T = 1 ms) 20000 ma DC at 95 V 2 contact(s) for inductive load (T = 50 ms) 20000 ma DC at 48 V 1 contact(s) for inductive load (T = 50 ms) 20000 ma DC at 140 V 3 contact(s) for inductive load (T = 50 ms) 300000 cycles 64 mm The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 11, 2017 1

CAD overall height CAD overall depth Product weight 64 mm 132 mm 0.59 kg Environment Standards EN/IEC 60947-3 Product certifications Protective treatment Ambient air temperature for operation -25...55 C Ambient air temperature for storage -40...70 C CULus 240 V 7.5 hp 1 phase CULus 480 V 25 hp 3 phases CULus 240 V 10 hp 3 phases CULus 120 V 3 hp 1 phase Class of protection against electric shock Class II conforming to NF C 20-030 Class II conforming to IEC 60536 TC 2

Dimensions Drawings Dimensions Front Mounting e support panel thickness 0.5 to 5.5 mm / 0.02 to 0.22 in in. a b c D1 mm in. mm in. mm in. mm in. 92.8 3.65 66 2.60 64 2.52 5.4 0.21 3

Mounting and Clearance Panel Cut-Out Front Mounting D2 D3 G1 mm in. mm in. mm in. 4.5 0.18 10 0.39 48 1.89 4

Technical Description Link Positions (Factory Mounted) Diagram for 1 to 4-pole Switches Select the number of poles according to the product characteristics I1 Input 1 I2 Input 2 Marking Angular Position of Switch Switching Program (1) 1-pole (2) 2-pole (3) 3-pole (4) 4-pole Convention Used for Switching Program Representation Contact closed Contact closed in 2 positions and maintained between the 2 positions 5

Sealed assembly for auto-maintain control Overlapping contacts contacts). Example: Spring return position: for a switching angle of 90, spring return is over 30 after the last position (for a maximum of 3 simultaneous 6

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schneider Electric: