Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Similar documents
Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

15 kv and 25 kv Thru-Bushings

25 kv Apparatus Bushings

Zinc Oxide Surge Arrester EXLIM R

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

BUSHINGS: GENERAL INFORMATION

Transformer bushings, type GOH. Technical guide

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Zinc-Oxide Surge Arrester TEXLIM Q-C

INSTRUCTION MANUAL CRS Combined insulation bushing

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Eaton s Cooper Power Systems

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Bushings for High Voltage AC Applications

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

GENERAL. CONSTRUCTION External

PORCELAIN BUSHINGS ED Series

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

Technical Specification

: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS :

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

EE 741 Over-voltage and Overcurrent. Spring 2014

Epoxy Technology Embedded Poles

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

Energy Division. PCA Single Column Polymeric Surge Arrester

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

PRODUCT CATALOG. Peak Demand Inc.

34-SDMS-01 SPECIFICATIONS FOR

GROUP D. Switch & Protective device.

34-SDMS-02 SPECIFICATIONS FOR

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Step 1: Collection of required data

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

026-2 : 1996 CEB STANDARD

Zinc Oxide Surge Arrester PEXLIM Q

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

A 1.2 kv class externally removable secondary bushing

045 : 2000 CEB STANDARD

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Products Catalogue Cable Lugs, Crimping Tools & Bus Bar

BHATINDA CERAMICS PRIVATE LIMITED (Mfrs/Exporters of High Tension Porcelain Insulators)

Transformer bushings, type GSA-OA Technical guide

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Technical Specification for Pole Mounted Capacitor Rack

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Bushing Insulators according to DIN and UNEL Standards

Product Description: Objective and Certification: Test Samples and Test Cable:

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

a Nexans company Catalogue 2009

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

Technical Specification of GECOL. Packaged Transformers

TABLE OF CONTENTS Page

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

CP Automatic capacitor bank

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

/ I S S : / S T S I

DM Condenser bushings, kV DURESCA

CAST RESIN TRANSFORMERS

Transcription:

4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1

Introduction: ZEP Monoblock Bushings are designed for use in liquid filled transformers, pad mount, kiosk style and industrial types. The units mount directly through the tank wall. Units are manufactured in accordance with EN 50336:2002 & BS 2562:1979 for use up to 12kV. All units utilize high conductivity copper bus bars as a single conductor (no joints) electro tin plated. Silver plating is available on request. The bus bar length can be determined by the customer and drilled to customer specific requirements. The units are simple to install and offer end users the ability to easily connect multiple cables, unlike standard porcelain LV bushings where palm extensions may need to be added dependent on number and size of cables to be fitted. Applications: These Monoblock bushings are suitable for operation under the following conditions: - with both ends fully immersed in an insulating liquid - one end fully or partially immersed in an insulating liquid and with the other end in air (indoor environment) - both ends in air (indoor environment) for special applications Ratings: (refer EN50336:2002) Permitted highest rated Voltage units can be operated at is as follows - Liquid / Air = 1.1kV - Air/Air = 1.1kV - Liquid/Liquid = 12kV Units are available with Standard values of rated current Ir as given below in amperes 1600 2500 2700 3150-4000 Copper bus bar sizes used for determined current rating are as follows: 63 x 12 = 1600A 63 x 20 = 2500A 63 x 25 = 2700A 63 x 35 = 3150A 70 x 35 = 4000A 2

Ratings (continued) Units are designed with a minimum nominal creepage distance for bushing ends intended for use in air of 55mm Dielectric Characteristics of the bushings are as follows: Power-frequency withstand voltage (60s) dry Power-frequency withstand voltage (60s) dry insulating liquid = 10kV where one or both ends are in air. = 28kV where both ends are fully immersed in an Lightening impulse withstand voltage (1.2/50µs) = 20kV where one or both ends are in air Lightening impulse withstand voltage (1.2/50µs) = 75kV where both ends are fully immersed in an Insulating liquid. Tank Mounting Detail: The drawing below shows the tank mounting detail required for mounting these bushings: NOTE: It important that the tank face to which the bushing is being mounted is flat with a maximum deviation of 1.0mm on both axis across the length and height of the mounting face. 3

Tightening Sequence and Torque: ZEPWW recommends a tightening torque of 30Nm on the M12 studs during assembly of the bushing onto the transformer tank in the sequence as shown. On the first pass the nuts should be tightened to 15Nm and on the second pass tightened to 30Nm. Note: Nuts once tightened to 30Nm should not be retightened. Routine Tests: The ZEPWW range of Monoblock Bushings is routinely tested as follows: Oil Leakage Sample Test: Of each batch of units manufactured a sample of 2% of units manufactured are selected for sample testing and subjected to an oil leakage test. The oil used complies with the requirements of BS148 as is heated to 75 C and maintained for 6 hours at a pressure of 1 Bar on the transformer side of the assembly with the other side exposed to atmosphere. Air LeakageTest: Each unit manufactured is subjected to an air leakage test for 1 hour a pressure of 1 Bar on the transformer side of the assembly with the other side exposed to atmosphere. 4

Type Tests Conducted on units includes: i) Verification of dimensions ii) Dry Lightening Impulse Voltage Withstand Test iii) Dry Power frequency Voltage Withstand Test iv) Measurement of Partial Discharge quantity before Cantilever Load test v) Cantilever Load Test vi) Temperature Rise Test Should any additional information be required please contact ZEP Information correct as at 3/3/2016 5