Attachment "C" Fremont Classrooms PLUMBING CATALOG DATA

Similar documents
Segment Name: CAST IRON 22X18 SERVICE SINK

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

Z x 17 Countertop Lavatory

HOSE BOXES. Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL

AquaSense TM ZTS6200EV Series

Installation Instructions

EZCarry High Performance Bariatric and Specialty Water Closet Carriers

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Installation Instructions

Geberit Flushing Technologies Electronic and Manual Flush Valves

Bariatric & Specialty. Closet Systems

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Installation Instructions

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

AquaSense AV ZER Series

S Plumbing Fixtures

Installation Instructions

REQUEST FOR QUOTATION CITY OF PORT HURON 100 McMorran Boulevard Room 217 Port Huron Michigan Phone: (810) Fax: (810)

Sloan & Zurn Flush Valves

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

AquaSense ZTR Series

Installation Instructions

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaSense AV ZER Series

AquaVantage AV ZER6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

How to Specify NH-39

INSTALLATION OF OFF-THE-FLOOR FIXTURES

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

SLOAN ZURN DELANY INLET SIZE FLUSH CONNECTION ROUGH-IN

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

STUDIO S BATH ACCESSORIES TOWEL BARS

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

AquaSense ZTR Series

A. This Section includes the following domestic water piping specialties:

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

AquaVantage Z6000AV Series


Geberit Manufacturing, Inc Boone Drive, Michigan City, IN Phone: (800) Fax: (219)

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:

Installation Instructions

AquaSense AV Closet ZEMS Series Automatic Systems Sensor-Operated AquaVantage Flushometer Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Instructions Series Series

Aquaflush Z6000 Series

Installation Instructions 1662SG SG.222

Specification Drainage Products Catalog and Price List

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual

Specification Drainage Products Catalog and Price List

T&S BRASS AND BRONZE WORKS, INC.

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

AquaSense TM ZEG Series

Finish Plumbing. Effective February 1, 2017 Replaces all previous Price Lists

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

Sensor-Operated Exposed Systems ZEMS6200 ZEMS ZEMS ZEMS6201 ZEMS6203

RetroFit Kits and Flush Valves. AquaSense Battery Powered Flush. Valves/Retrofit Kits. E-Z Flush RetroFit Kits And Valves

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Finish Plumbing. FP0718 Customer Guide. Effective July 1, 2018 Replaces All Previous Price Lists

Installation Instructions 1662SG SG.224

Installation Instructions

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

PG-35AV-CH Coiled Hose and Spray Valve. PG-8WSAV-08 Lighweight Aluminum Spray Unit

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Maintenance Guide. OPTIMA Components:

Installation Instructions 7024

PLUMBING FIXTURES DESIGN AND CONSTRUCTION STANDARD

CATALOGUE Valves ~ Faucets ~ Specialties ~ Fittings & Nipples

Convert Your Manual Flush Valves To Sensor-Operated Hands-Free Flushing With The Zurn E-Z Flush

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

AquaSense AV TM ZEMS Series

Installation Instructions

AquaSense ZTR Series

Installation Instructions 1662SG SG.223

T&S BRASS AND BRONZE WORKS, INC.

Outdoor Bottle Fillers

REPLACEMENT PARTS Quick Reference Guide

Installation Instructions

Installation Instructions

AquaSpec Commercial Products

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

Bid # Plumbing Supplies RESULTS

INSTALLATION INSTRUCTIONS

MAG. Sloan Water Closets. Sloan Water Closets. Any Fixture, Any Flushometers

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

INSTALLATION INSTRUCTIONS

Sloan Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 6. SLIP JOINT GASKETS AND RINGS

ETF-600 Sensor Operated Lavatory Faucet

Hops Fixture/ Flow Rate Schedule. Fixture Model# Performan #of Total Toilets All Toilets Kelston K Average 1.28

Transcription:

Attachment "C" Fremont Classrooms PLUMBING CATALOG DATA

Fremont Classrooms PLUMBING CATALOG DATA Table of Contents Symbol Description Page No. WC-1 WATER CLOSET 1-4 WC-2 WATER CLOSET 5-8 U-1 URINAL 9-10 L-1 LAVATORY 11-17 HB-1 HOSE BIBB 18-19 TP-1 TRAP PRIMER 20-22 WHA-1 WATER HAMMER ARRESTOR 23-25 FD-1 FLOOR DRAIN 26-28

Z5655 1.28 GPF Elongated, Floor Mounted, EcoVantage Flush Valve Toilet System TAG Z5655 HET Series Zurn One HET Toilet System designed for optimal performance between Zurn fixture and Zurn flush valve to save water. 1.28 gpf (gallons per flush) 20% water savings over standard 1.6 gpf system Vitreous china Elongated front rim 2" fully glazed trapway High efficiency siphon jet flush action Zurn product system component compatibility and quality assurance Shipping Weight: 55 lbs. Z5655 Series Elongated Recommended Trim: Z5955SS-EL Elongated, standard white, open front toilet seat less cover with stainless steel check hinge. Z5972-COMB Closet bolt/wax ring kit. Note: To ensure system performance minimum running water pressure = 25 psi These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standard A112.19.2 and CAN/CSA B45 requirements. Engineering Specification: Z5655 AquaSense, EcoVantage High Efficiency Toilet System -System comes complete with exposed ZTS6200EV high efficiency flushometer valve and floor mounted, vitreous china toilet. The system is designed to perform to industry standards with as little as 1.28 gallons per flush. Valve is operated by an infrared convergence-type proximity sensor with smart technology, powered by a single 9 volt battery, furnished with a vandal resistant chrome plated cast brass valve body, chloramine resistant internal seals, manual over ride button and reversible cover. Complete with high pressure vacuum breaker, one piece hex coupling nut, adjustable tailpiece, spud coupling and flange for top spud connection. Control stop has internal siphon-guard protection, vandal resistant stop cap, sweat solder kit and a cast wall flange with set screw. Vitreous china toilet is 1-1/2 top spud with 2 fully glazed trapway and siphon jet action. Valve and toilet are an engineered system designed to provide optimal performance and 20% water savings over 1.6 gpf conventional toilets. This space is for Architectural/engineering Approval See Zurn One Systems for suggested packages. Zurn Plumbing Products Group Commercial Brass and Fixtures Operation 2640 South Work Street Falconer, NY 14733 Phone: 716-665-1132 Fax: 716-665-1135 www.zurn.com REV.B DWG. NO. 83072 DATE: 12/12/07 C.N. NO. 97831 PRODUCT NO. Z5655 Page 1 of 28

Z5655 1.28 GPF Elongated, Floor Mounted, EcoVantage Flush Valve Toilet System Rough-in TAG Rough-in dimensions for Z5655 Series Z5655 with top spud 1 [25] I.P.S. SUPPLY FINISHED WALL FINISHED FLOOR These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standard A112.19.2 and CAN/CSA B45 requirements. Zurn Plumbing Products Group Commercial Brass and Fixtures Operation 2640 South Work Street Falconer, NY 14733 Phone: 716-665-1132 Fax: 716-665-1135 www.zurn.com REV. B DWG. NO. 83072 DATE: 12/12/07 C.N. NO. 97831 PRODUCT NO. Z5655 Page 2 of 28

EcoVantage Model TAG Exposed ZER6200PEV-CPM Model Sensor Operated Battery Powered Flush Valve for 1.28 GPF Water Closets Flow Options -Standard Flush 1.28 Gal. Low Consumption Flush Suffix Options (Check/Specify Appropriate Options) -YJ Split Ring Pipe Support -YK Solid Ring Pipe Support -YO Bumper on Angle Stop Other ENGINEERING SPECIFICATION: ZURN ZER6200PEV-CPM Sensor Operated Battery Powered EcoVantage Piston Operated Exposed Valve for 1.28 GPF Closet - The EcoVantage valve is an exposed, quiet piston type with self cleaning bypass, chrome plated flushometer valve with a polished exterior. The valve is ADA compliant and incorporates a 6VDC motor actuator, a battery powered automatic sensor, chrome plated metal cover with manual override push button, 10 degree angled sensor, high back pressure vacuum breaker, one piece hex coupling nut, adjustable tailpiece, spud coupling and flange for top spud connection. Control stop has internal siphon guard protection. Internal seals are made of chloramine resistant materials. This space is for Architectural/engineering Approval ZURN INDUSTRIES, LLC COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone: 1-800-997-3876 Fax: 919-775-3541 World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga, Ontario L4V1L2 Phone: 905-405-8272 Fax: 905-405-1292 EcoVantage is a registered trademark of Zurn Industries, LLC. Rev. A Date: 11/12/08 Dwg. No. 81900 Product No. ZER6200PEV-CPM Page 3 of 28

Page 4 of 28

Z5654-BWL HET Elongated Floor Mounted EcoVantage Flush Valve Toilet System TAG Z5654 HET Series Zurn High Efficiency Toilets and paired performace flush valve systems are designed to exceed industry standards while using as little as 1.1 gallons of water per flush. Universal high efficiency toilet can be specified with 1.28 gpf [4.8 Lpf], 1.6 gpf [6.0 Lpf] or dual flush valves. Vitreous china Elongated front rim 2-1/8" fully glazed trapway 14" rim height High efficiency siphon jet flush action Shipping Weight: 55 lbs. Z5654 Series Elongated Recommended Trim: Engineering Specification Z5654-BWL EcoVantage High Efficiency Toilet System - Vitreous China, 1.1 gpf [4.16 Lpf] or greater high efficiency, 14 height, floor mounted, bottom outlet toilet with siphon jet flushing action and elongated front rim with 1-1/2 top spud. This bowl is designed to perform to industry standards with as little as 1.1 gallons per flush. Z5955SS-EL Elongated, standard white, open front toilet seat less cover with stainless steel check hinge. Z5972-COMB Closet bolt/wax ring kit Note: To ensure system performance: Minimum Running Water Pressure = 25 psi. These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standard A112.19.2, CAN/CSA B45, and Texas Accessibility Standards (TAS) requirements. This space is for Architectural/Engineering Approval EcoVantage is a registered trademark of Zurn Industries See Zurn One Systems for suggested packages. ZURN INDUSTRIES, LLC. COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone: 1-800-997-3876 Fax: 919-775-3541 World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga, Ontario L4V1L2 Phone: 905-405-8272 Fax: 905-405-1292 EcoVantage and AV are trademarks of Zurn Industries, LLC. REV. A DATE: 7/4/13 DWG. NO. 303029 PRODUCT NO. Z5654-BWL Page 5 of 28

Z5654-BWL HET Elongated Floor Mounted EcoVantage Flush Valve Toilet System TAG Rough-in Rough-in dimensions for Z5654 Series Z5654 with top spud, shown with Z6000AV-HET manual valve These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standard A112.19.2, CAN/CSA B45, and Texas Accessibility Standards (TAS) requirements. EcoVantage is a registered trademark of Zurn Industries ZURN INDUSTRIES, LLC. COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone: 1-800-997-3876 Fax: 919-775-3541 World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga, Ontario L4V1L2 Phone: 905-405-8272 Fax: 905-405-1292 EcoVantage and AV are trademarks of Zurn Industries, LLC.. REV. A DATE: 7/4/13 DWG. NO. 303029 PRODUCT NO. Z5654-BWL Page 6 of 28

EcoVantage Model TAG Exposed ZER6200PEV-CPM Model Sensor Operated Battery Powered Flush Valve for 1.28 GPF Water Closets Flow Options -Standard Flush 1.28 Gal. Low Consumption Flush Suffix Options (Check/Specify Appropriate Options) -YJ Split Ring Pipe Support -YK Solid Ring Pipe Support -YO Bumper on Angle Stop Other ENGINEERING SPECIFICATION: ZURN ZER6200PEV-CPM Sensor Operated Battery Powered EcoVantage Piston Operated Exposed Valve for 1.28 GPF Closet - The EcoVantage valve is an exposed, quiet piston type with self cleaning bypass, chrome plated flushometer valve with a polished exterior. The valve is ADA compliant and incorporates a 6VDC motor actuator, a battery powered automatic sensor, chrome plated metal cover with manual override push button, 10 degree angled sensor, high back pressure vacuum breaker, one piece hex coupling nut, adjustable tailpiece, spud coupling and flange for top spud connection. Control stop has internal siphon guard protection. Internal seals are made of chloramine resistant materials. This space is for Architectural/engineering Approval ZURN INDUSTRIES, LLC COMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone: 1-800-997-3876 Fax: 919-775-3541 World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga, Ontario L4V1L2 Phone: 905-405-8272 Fax: 905-405-1292 EcoVantage is a registered trademark of Zurn Industries, LLC. Rev. A Date: 11/12/08 Dwg. No. 81900 Product No. ZER6200PEV-CPM Page 7 of 28

Page 8 of 28

Model F-4000 Specifications Description The Falcon model F-4000 is a vitreous china wall hung, wall outlet waterfree urinal. It requires no flush valve or water supply, and plumbs to standard drain connections. The F-4000 utilizes a replaceable sealed locking cartridge, with bayonet tabs, is made of recyclable ABS plastic and utilizes a 100% biodegradable liquid sealant. Specifications Vitreous china fixture Housing (H-1, Mod. 3) Cartridge kit* One piece wall bracket with anchors Uni-coupler Drain line test cap Instruction sheet *Additional cartridges sold separately Colors Standard white; available in other colors Nominal Dimensions (W x H x D) 15.375 x 22.625 x 14 inches [ 391 x 575 x 356 mm ] Waterfree Urinal Vitreous China Sealed Cartridge Approximate Weight 35 lbs. [ 15.8 kg ] Compliance Certifications Meets ANSI/ASME A112.19.19-2006 for vitreous china non-water urinals. Meets the American Disabilities Act guidelines and ANSI A117.1 for accessible and usable buildings and facilities. Complies with International Plumbing Code and National Standard Plumbing Code. Housing The factory installed housing is comprised of a bowl with a tailpiece and a mounting flange of 316 Stainless Steel. It is sealed into the bowl drain opening by a profile gasket made of a synthetic rubber. The housing and gasket are compressed into the drain opening by the installation of a retaining nut, and a friction washer. Cartridge kit The patented cartridge is engineered to last an average of three to four months in typical installations and to receive urine through drain holes. Urine passes through an immiscible layer of biodgradable sealant, continues through a siphon trap system, and flows out through a baffle to prevent the loss of sealant. A discharge tube in the housing directs the flow of urine into the building drain system. The cartridge is designed as a replaceable component when its function has been exhausted. Drain Coupler The housing is connected to the building drain system by means of the Falcon Uni-coupler. The coupler conforms to NSF 14 for plastic pipes and fittings. It is designed to be used in both retrofit and new installations. It offers a variety of configurations which allow it to couple to most existing drain openings. Drain Connection and Material Installs on standard 2-inch drain connections with spud flange or threaded nipple. Suitable DWV materials include cast iron, galvanized steel, ABS, and PVC. Waterfree urinals are not recommended for installation on copper DWV due to copper s susceptibility to corrosion. The information in this document is subject to change without notice. Page 9 of 28

Model F-4000 Specifications A 14" [356] 2" [50] 7 7/8" [200] 2 1/4" [58] 22 5/8" [575] 9 1/2" [240] A FRONT VIEW 15 3/8" [391] 5 7/8" [150] SECTION A-A SCALE 1 : 9 10 5/8" [270] BACK VIEW HANGER BRACKET TOP VIEW 31 1/4" [ 794 ] 14 1/4" [362] Drain nipple should be 2 diameter and exposed 1/2 to 3/4 beyond the finished wall. EXISTING SPUD FLANGE 24" [ 610 ] 17" [ 432 ] Rough-Hieght For 24" Lip New Drain Rough-In Hieght Should Be 10" For A Lip Height Of 17" For ADA Compliance FLOOR LINE UCII CONNECTION ROUGH-IN & BRACKET LOCATION Revised 12/19/05 The information in this document is subject to change without notice. Falcon Waterfree Technologies, LLC Tel: 866.275.3718 (toll-free) Fax: 616.954.3579 info@falconwaterfree.com www.falconwaterfree.com Page 10 of 28 Copyright 2008 Falcon Waterfree Technologies, LLC. All rights reserved. 010 (07/08)

Ceco - Enameled and Cast Iron Plumbing Fixtures http://www.cecosinks.com/catalog/printer.lasso?c=33073 Page 11 of 28 2 of 3 1/3/2011 2:32 PM

U MANUAL 3400-ABCP Deck Mounted Faucet - 4" Centers PRODUCT TYPE MeterMix Deck Mounted Single Inlet Metering Faucet FEATURES &SPECIFICATIONS Polished chrome plated finish ECAST design provides durable brass construction with total lead content less than 0.25% by weighted average Single water inlet 4 3/4" C-C Integral spout.5 GPM (1.9 L/min) pressure compensating vandal resistant spray outlet, catalog #E2805 Metal handle with color coded indexing and concealed vandal resistant screw, catalog #3400-002 MVP push button, adjustable self closing metering cartridge, catalog #671-X 0.25 Gal/Cycle Max. 1 2" NPSM supply inlet with coupling nut for 3/8" or 1 2" flexible riser Mounting hardware included Job Name Item Number Section/Tag Model Specified Architect Engineer Contractor Submitted as Shown Submitted with Variations Date PERFORMANCE SPECIFICATION Rated Operating Pressure: 20-125 PSI Rated Operating Temperature: 40-140 F WARRANTY Lifetime Limited Faucet Warranty 5-Year Limited Cartridge Warranty 1-Year Limited Finish Warranty COMPLIANT TO California Lead Plumbing Law (AB1953) NSF 61, Sec. 9 ASME A112.18.1 CSA B125 ADA.. S M 10/08 G R E E N C O U N C E M B U B I L E I L D R I N G 2100 South Clearwater Drive Des Plaines, IL 60018 P: 847/803-5000 F: 847/803-5454 Technical: 800/TEC-TRUE www.chicagofaucets.com Page 12 of 28

3400-ABCP Deck Mounted Faucet - 4" Centers ARCHITECT/ENGINEER SPECIFICATION Chicago Faucets No. 3400-ABCP, Polished chrome plated solid brass body and spout. ECAST construction with less than 0.25% lead content by weighted average. Integral shanks, 4 3/4" C-C integral spout..5 GPM pressure compensating vandal resistant spray outlet. Metal handle with concealed vandal resistant screw. 0.25 Gal/Cycle push button self closing metering valve with adjustable cycle time feature. 1/2" NPSM supply inlet with coupling nut for connection to 3/8" or 1/2" flexible riser. All mounting hardware is included. This product meets ADA requirements and is tested and certified to industry standards: ASME A112.18.1, NSF 61, Sec. 9, CSA B125 and California Lead Plumbing Law (AB1953). OPERATION AND MAINTENANCE Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning this product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at www.chicagofaucets.com. ECAST, from Chicago Faucets, is the line of durable, high quality brass faucets and fixtures that are designed and manufactured with less than one quarter of one percent (0.25%) total lead content by weighted average. These products are intended for installation where state laws and local codes mandate lead content levels or in any location where lead content is a concern. C US 10/08 Product specifications subject to change without notice. 2100 South Clearwater Drive Des Plaines, IL 60018 P: 847/803-5000 F: 847/803-5454 Technical: 800/TEC-TRUE www.chicagofaucets.com Page 13 of 28

U MANUAL 1017-ABCP Angle Service Stop Fitting PRODUCT TYPE Angle Service Stop Fitting FEATURES &SPECIFICATIONS Polished chrome plated finish ECAST design provides durable brass construction with total lead content less than 0.25% by weighted average 2 1/4" loose key handle, catalog #293-6 Loose key cap with plug button Slow compression renewable cartridge that closes with water pressure with square broach to facilitate handle removal, catalog #217-XTLH 1/2" NPT female inlet 3 8" O.D. x 12" flexible supply riser Loose wall flange with tangs Job Name Item Number Section/Tag Model Specified Architect Engineer Contractor Submitted as Shown Submitted with Variations Date PERFORMANCE SPECIFICATION Rated Operating Pressure: 20-125 PSI Rated Operating Temperature: 40-140 F WARRANTY Lifetime Limited Faucet Warranty 5-Year Limited Cartridge Warranty 1-Year Limited Finish Warranty COMPLIANT TO California Lead Plumbing Law (AB1953) NSF 61, Sec. 9 ASME A112.18.1 CSA B125.. S M 10/08 G R E E N C O U N C E M B U B I L E I L D R I N G 2100 South Clearwater Drive Des Plaines, IL 60018 P: 847/803-5000 F: 847/803-5454 Technical: 800/TEC-TRUE www.chicagofaucets.com Page 14 of 28

1017-ABCP Angle Service Stop with Supply Tube ARCHITECT/ENGINEER SPECIFICATION Chicago Faucets No. 1017-ABCP, Polished chrome plated solid brass body and spout. ECAST construction with less than 0.25% lead content by weighted average. 2 1/4" loose key handle. Slow compression renewable cartridge designed to close with water pressure with square tapered broach feature to help facilitate handle removal. 1/2" NPT female inlet. 3 8" O.D. x 12" flexible supply riser. This product is tested and certified to industry standards: ASME A112.18.1, NSF 61, Sec. 9, CSA B125 and California Lead Plumbing Law (AB1953). 3/8" [9.5mm] O.D. x 12" [305mm] LG. NOMINAL FLEXIBLE SUPPLY RISER 1/2 " [13mm] 2-1/4 " [57mm] 2-1/4 " [57mm] 2-1/2 " DIA. [64mm] 1-7/16 " [37mm] 3-1/2 " [89mm] 1/2" NPT FEMALE THREAD INLET OPERATION AND MAINTENANCE Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning this product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at www.chicagofaucets.com. ECAST, from Chicago Faucets, is the line of durable, high quality brass faucets and fixtures that are designed and manufactured with less than one quarter of one percent (0.25%) total lead content by weighted average. These products are intended for installation where state laws and local codes mandate lead content levels or in any location where lead content is a concern. C US 10/08 Product specifications subject to change without notice. 2100 South Clearwater Drive Des Plaines, IL 60018 P: 847/803-5000 F: 847/803-5454 Technical: 800/TEC-TRUE www.chicagofaucets.com Page 15 of 28

Page 16 of 28

Page 17 of 28

Hose & Supply Boxes 8101 Series Lumaloy Recessed Hose Box (Single Temperature) 8104 Fixture May Show Some Available Options Lumaloy Recessed Hose Box (Single Temperature) Lumaloy, Recessed Hose Boxes are designed for attractive service in both interior and exterior walls not subject to freezing. Recessed design prevents accidents which are common to surfacemounted or protruding hose valves. Hose Box is a one piece cast construction and is furnished with two stainless steel angles for anchoring to the wall construction. Hose box has a built-in drip lip. Wall flange is cast aluminum with prime coat finish. Door is an exclusive wedgelock design with recessed cam lock. When in the fully opened position, it will remain up and out of the way. Valve and Stop Body is cast bronze with exposed parts chrome-plated. Valve and Stop feature tamper-resistant lockshield bonnet and replaceable cartridge containing all wearing parts including the seat. The body casting is gasketed where it joins the box and is securely anchored with stainless steel tamper-resistant screws. Supply inlet is 3/4 NPT female. Outlet is 3/4 male hose thread. Screwdriver Stop in supply permits servicing the control valve without shutting down the water supply. Vacuum breaker models prevent contamination of the potable water supply. Vacuum breakers are atmospheric type and conform to the requirements of ASSE Standard 1011. Check local code authority for vacuum breaker requirements. GUIDE SPECIFICATION Please visit www.acorneng.com for most current specifications. Provide and install an Acorn Lumaloy, Recessed Hose Box (specify model number) with wall flange and built-in drip lip. Box shall be one piece cast construction, fabricated from Lumaloy with plain finish. Frame and door shall have a prime coat finish. Door shall have a recessed cam lock. Door shall remain up and out of the way when in the fully opened position. Valve shall be a replaceable cartridge type with vandal-resistant lockshield bonnet, removable loose key wheel handle and screwdriver operated stop. Page # H.8101 Revised: 9/9/03 Acorn Engineering Company 15125 Proctor Avenue P.O. Box 3527 City of Industry, CA 91744-0527 U.S.A. Tel: (800) 488-8999 (626) 336-4561 Fax: (626) 961-2200 www.acorneng.com E-mail: info@acorneng.com Page 18 of 28

Hose & Supply Boxes 8101 Lumaloy Recessed Hose Box (Single Temperature) BASE MODEL NUMBER (Must Specify) HOSE BOX LESS DOOR AND FRAME -8101 Single Temperature Less Vacuum Breaker -8102 Single Temperature With Vacuum Breaker HOSE BOX WITH DOOR AND FRAME -8103 Single Temperature Less Vacuum Breaker -8104 Single Temperature With Vacuum Breaker Product Options - * None Available Please visit www.acorneng.com for most current specifications. Important: Installation instructions and current rough-in are furnished with each fixture. Do not rough in without certified dimensions. Dimensions are subject to manufacturer s tolerance of plus or minus 1/4 and change without notice. Acorn assumes no responsibility for use of void or superseded data. Copyright 2003 Acorn Engineering Company Selection Summary Model No. & Option Quantity Approved for Manufacturing Company Title Signature Date Page # H.8101 Revised: 9/9/03 Acorn Engineering Company 15125 Proctor Avenue P.O. Box 3527 City of Industry, CA 91744-0527 U.S.A. Tel: (800) 488-8999 (626) 336-4561 Fax: (626) 961-2200 www.acorneng.com E-mail: info@acorneng.com Page 19 of 28

Location: STAINLESS STEEL FILTER SCREEN SPECIFICATION: MIFAB model MR-500 pressure drop activated brass trap seal primer, with inlet opening of ½ (13) male N.P.T. and outlet opening of female ½ (13) N.P.T. Complete with four view holes and removable filter screen. Serves up to 6 floor drain traps and requires no adjustments and no air pre-charge. SPECIFICATION: MIFAB model M1-500 pressure drop activated brass trap seal primer, with inlet opening of ½ (13) male N.P.T. and outlet opening of female ½ (13) N.P.T. Complete with four view holes and removable filter screen. Serves up to 10 floor drain traps and requires no adjustments and no air pre-charge. SPECIFICATION: MIFAB model M2-500 pressure drop activated brass trap seal primer, with inlet opening of ½ (13) male N.P.T. and outlet opening of female ½ (13) N.P.T. Complete with four view holes and removable filter screen. Serves up to 3 floor drain traps and requires no adjustments and no air pre-charge. SUFFIX -NPB -BA OPTIONAL VARIATIONS: Lead Free Material* Buy American Act compliant product *The wetted surface of the -NPB Series of water hammer arrestors contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. FUNCTION AND DESCRIPTION: MIFAB s M-500 Series of pressure activated trap seal primers (MR-500, M1-500 and M2-500) can be connected to any cold water line, and will be automatically activated when a valve or faucet, that is on the line, is opened. A pressure drop of three p.s.i. will activate all of the trap seal primers. MIFAB s M-500 Series of trap seal primers can be disassembled in the field. Their unique design permits filter replacement without affecting the performance of the primer. The O ring seals are tested for reliability at a temperature range of -40 degrees to 450 degrees F. The M-500 Series of trap seal primers do not require adjustment. The opening range for all of MIFAB s M-500 Series of trap seal primers is 20 to 125 p.s.i. All three models are listed with I.A.P.M.O. and C.S.A. and are tested and certified to the A.S.S.E. Standard 1018 and are so marked. U.S. Patent # 6,152,164. 2013-01-30 Page 20 of 28

Location: INSTALLATION INSTRUCTIONS: An 1 1/8 open end wrench should be used to install the M-500 Series of trap seal primers to the line by using the flats on the top of the trap seal primer. Water lines must be flushed before installing MIFAB s M-500 Series of trap seal primers. The trap seal primers should be cycled at least six times to ensure optimum performance. Ensure that all flux and other debris is removed. Use only teflon tape around threads. Do not use pipe dope. Do not solder fittings directly onto the inlet or outlet of the primer. Failure to follow these instructions will negatively affect performance of the product. MIFAB s primers have a unique design which allows the primer to be taken apart and cleaned before re-assembly. Do this in the event of excess water discharge. Do not install the trap seal primers closer than forty feet apart when using the same potable water supply line. The device should be located within 20 of the valve or faucet for optimal discharge. Trap seal primers should be mounted one foot above the finished floor for every twenty feet of floor drain trap make-up water line. For easy access to the trap seal primer, install a union connection above it. Install a line shut off valve upstream of the trap seal primer in order to shut off the water supply when performing maintenance on the trap seal primer. INSPECTION INSTRUCTIONS: After installing and pre-cycling the trap seal primer, use any of the four holes to view water discharge from the orifice. A light can be placed opposite the observed view hole to improve clarity in this inspection. MAINTENANCE INSTRUCTIONS: In order to replace the filter screen, remove the trap seal primer by using an open end wrench on the top set of flats. Grasp the top of the filter screen with fingers, squeeze and remove the filter. Insert the new filter screen by squeezing and pushing it firmly down into the top of the trap seal primer. Re-install the trap seal primer using the top set of flats. In regions that experience heavy residual deposits such as calcium in the water supply, MIFAB s M-500 Series of trap seal primers can be field refurbished by removing the bottom end of the primer and replacing the cartridge. 2013-01-30 Page 21 of 28

Location: Trap Seal Primer Troubleshooting Following are some things to trouble shoot when it comes to our M-500 Series of Trap Seal Primers (M1-500, M2-500, M-500). 1) What is the line pressure for the Installation? The M-500 Series will work in 35-80psi. 2) How far away is the trap seal primer from the source of the pressure drop? Anything farther away than 20 feet is an issue, as the farther the primer is away from the source of the pressure drop, the less likely it will sense it and work. 3) What is the pressure drop where the primer is? MIFAB s M-500 Series of primers will work with as little as 3 psi in pressure drop. With today's low flow and consumption faucets, there is less pressure drop being created when the faucets and toilets are used. 4) Water hammer arrestors on the line can also affect pressure drop in the line. It would be best to get a pressure reading where the trap primer is installed. The M-500 series needs a fast, sharp pressure drop to activate. The long pipe run to the trap primer and the water hammer arrestor may not be allowing the trap primer to function properly. 5) Look at the gauge fluctuation Is it a quick and sharp pressure drop? Or did it gradually drop? The trap primers need a quick pressure drop to activate. A slow gradual pressure drop may not be enough to activate the M-500. That is why we state that they should be as close to the pressure drop source as possible. The M1-500 has the most buoyant cartridge and should perform the best. If the trap primer looked good and was filled with water then it is the rate of the pressure drop that is causing the issue. Also refer to the copy in the Trap Seal Primer section in the MPB-2012-USA List Price book. 2013-01-30 Page 22 of 28

WATER HAMMER ARRESTORS SIZED IN ACCORDANCE WITH SERVICE PIPE DIMENSION PPP Water Hammer Arrestors are engineered to permit the impact or attaching end to match the internal cross sectional area of piping in which it is to be installed. This design assures that 100% of the surge or shock will be arrested on initial impact. A maintenance-free installation is assured when using this type of arrestor... the only moving part is the free-moving piston furnished with "O" ring seals which have been tested for reliability in excess of normal operating ranges. PPP WATER HAMMER ARRESTORS SPECIFIED FOR MANY INSTALLATIONS! Water Hammer Arrestors are specified for both commercial and residential uses... for commercial laundrys, restaurants, motels.. and for dish washers and laundry equipment in the home. FLUID HAMMER IN FLUID TRANSMISSION LINES Fluid Hammer is a series of hydraulic shock waves generated within the confines of a piping system due to the sudden stopping of fluid flow. This condition is caused by fast closing of positive valves incorporated within the system. The effects of fluid hammer is damaging if allowed to exist for any length of time and will result in broken pipes and damage to other components in the system. Page 23 of 28

SYSTEM-RATED WATER HAMMER ARRESTORS SPECIFICATIONS & INSTALLATIONS DIMENSIONAL AND AIR- LOADING DATA INSTALLATION: May be installed in new or existing plumbing systems with a standard pipe tee. PPP SIZING AND SELECTION TABLE PPP CROSS SIZE UNITS REF.PDI 1/2" 1-11 A 3/4" 12-32 B 1" 33-60 C 1 61-113 D 1/4" 1 114-154 E A B O.A.L. N.P.T. AIR Preload PSI PART NUMBER 5" 1/2" 60 SC-500 6" 3/4" 60 SC-750 6 3/4" 1" 60 SC-1000 8 3/8" 1 1/4" 60 SC-1250 10 1 1/2" 60 SC-1500 SIZING INFORMATION MAINTENANCE: Maintenance free - the piston is the only moving part. TEST PRESSURE: Tested in excess of 500 PSI TEMPERATURE RANGE: -40 F to +212 F (-54 C to +100 C) For equipment and fixtures not listed below, size in accordance with load values (WSFU) assigned to same. TYPE OF WEIGHT IN FIXTURE - UNITS FIXTURE SUPPLY Public Private CONTROL C.W. H.W. C.W. H.W. Water Closet Flush Valve 10-6 - Water Closet Flush Tank 5-3 - RECOMMENDED ROUGH-IN OF PPP WATER HAMMER ARRESTORS Page 24 of 28

RECOMMENDED ROUGH-IN OF PPP WATER HAMMER ARRESTORS Copyright 2000 PPP Inc. All rights reserved. Design by 3D Access.com Page 25 of 28

DRAWN BY: CHECKED BY: APPROVED BY: DATE: SCALE: SIZE DRAWING NUMBER 2005 PJ TD TD 5-17-85 NONE A S2005 R DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA SMITH CUSTOMER DRIVEN SINCE 1926 LOCATION FLOOR OR SHOWER DRAINS WITH ADJUSTABLE STRAINER HEADS FUNCTION: General service floor drain for use in showers, toilets, kitchens and other finished areas where foot traffic is expected. The round top strainer head is used for all types of poured finished floors. The square top is particularly adaptable to floors that are finished in material of square or straight line pattern. Reversible flashing collar permits adjustment of the strainer to meet finished floor level. Low Position XX-MIN MAX JAY R. SMITH MFG. CO. MEMBER OF MORRIS GROUP INTERNATIONAL POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com 1 1/4 (32) Trap Primer Connection (When Specified) NO-HUB OUTLET Fig. 2005Y (A) ROUND TOP Fig. 2005Y. (B) SQUARE TOP Outlet Size 02(50) 03(75) 04(100) 9 (230) DIA B DIA or SQ **6 3/4 (170) Nickel Bronze Strainer Head 05(125) DIA or SQ 06(150) DIA or SQ 08(205) DIA or SQ This dimension to internal stop of speedi-set gasket. Add 3/8"(10) to all min/max dimensions for round strainers. * Collar is reversible to obtain extreme high and low strainer positions. Not available for 5"(125) size strainer. ** MIN 6 3/4"(170) hole required for core drilled application. REGULARLY FURNISHED: Duco Cast Iron Body with Flashing Collar and Adjustable Strainer Head as Indicated by Suffix Letter Selected. NOTE: Dimensions shown in parentheses are in millimeters. Meets ASME Standard A112.6.3-2001 02(50), 03(75) or 04"(100) sizes only. A ASPE A (Pipe Size) = 02(50), 03(75), 04(100), 05(125) or 06(150) MEMBER OF: High Position X-MIN MAX Low Position XX-MIN MAX 4(100) 1 1/4 (32) Seepage Openings SANITARY E N G I N E E R I N G Prevention Rather Than Cure Trap Primer Connection (When Specified) Strainer Size B DIA or SQ 05 (125) 06 (150) 07 (180) 08 (205) 09 (230) 10 (255) VARIATIONS: Flapper Type Backwater Valve -V Hinged Grate -H L Speedi-Set Service Weight 2(50), 3(75) & 4"(100) only LXH Speedi-Set Extra Heavy 2(50), 3(75) & 4"(100) only Sediment Bucket -B Trap Primer Connection -P050 1/2" (13) & -P075 3/4" (19) Vandal Proof Screws -U Wide Flanged Strainer (Specify Fig. DX2005) T Threaded Outlet Heelproof Grate -HP -AHP (Round) or -BHP (Square) Quad Close Trap Seal (Specify Fig. 2692) SPEEDI-SET OUTLET Fig. 2005L (A) ROUND TOP Fig. 2005L (B) SQUARE TOP *Collar In High Position X MIN MAX 9 (230) DIA B DIA or SQ **6 3/4 (170) *Collar In Low Position XX MIN MAX 1 1/4(32) 2 1/4(57) 3/4(19) 1 5/8(41) 1 1/4(32) 2 1/4(57) 3/4(19) 1 5/8(41) 1 1/4(32) 2 1/4(57) 7/8(22) 1 7/8(48) 1 1/2(38) 2 1/2(64) 1 1/2(38) 2 3/8(60) 1 1/2(38) 2 3/8(60) 1(25) 1(25) 1(25) 1 7/8(48) 1 7/8(48) 1 7/8(48) A High Position X-MIN MAX 2 5/8"(67) Free Area SQ IN (SQ CM) 4(100) Seepage Openings ROUND SQUARE 7(45) 6.5(42) 9(58) 12.5(81) 14(90) 11(71) 17(110) 14(90) 18(116) 16(103) 23(48) 16(103) OPTIONAL Bronze Body -BB Chrome Plated Strainer -CP Galvanized Cast Iron Body -G Nickel Bronze Strainer -NB Polished Bronze Strainer -PB Stainless Steel (Specify Fig. 9700-A) SEE PM0457 FOR OPTIONAL STRAINER HEADS. FIGURE NUMBER R 6-10-15 Revised Variations TBW CL Q 11-18-11 Rev. Dwg., Var. TBW CR P 11-20-09 Revised Variations RN BW N 12/18/08 Addition to Variations JJ BW REV. DATE DESCRIPTION BY CKD. BY WEIGHT POUNDS VOLUME CUBIC FEET FIGURE NUMBER 2005 Page 26 of 28

DRAWN BY: CHECKED BY: APPROVED BY: DATE: SCALE SIZE DRAWING NUMBER PJ TD TD 5-17-85 NONE PM0457 SH 1 of 2 G A 2010 SERIES OPTIONAL STRAINER HEADS FIGURE NUMBER DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE ASSUME NO RESPONSIBILIT OR USE OF SUPERSEDED OR VOID DATA SMITH CUSTOMER DRIVEN SINCE 1926 B SUFFIX -A H ROUND STRAINER Chrome Plated -CP Polished Bronze -PB LOCATION OPTIONAL STRAINER HEADS VARIATIONS: *Hinged Grate (Specify Suffix -AH) Sediment Bucket -B Vandal Proof Screws -U B DIA 05 (125) 06 (150) 07 (180) 08 (205) 09 (230) 10 (255) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) 2 1/2 (64) 2 3/4 (70) MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) X MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 2 1/2 (64) 2 3/4 (70) B SUFFIX -B Specify Type, Size & Finish eg: A05NB *Not available for 05" (125) size SQUARE STRAINER Chrome Plated -CP Polished Bronze -PB H VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -BV) 05 (125), 06 (150), 07 (180) or 08" (205) sizes only *Hinged Grate (Specify Suffix -BH) Sediment Bucket -B Vandal Proof Screws -U B DIA 05 (125) 06 (150) 07 (180) 08 (205) 09 (230) 10 (255) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) 2 1/4 (57) 2 1/4 (57) MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) X MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 2 1/4 (57) 2 3/8 (60) SUFFIX -C Specify Type, Size & Finish eg: B05NB *Not available for 05" (125) size REINFORCED ROUND STRAINER FUNCTION: Used in finished floors where light wheeled loads are anticipated. B H Chrome Plated -CP Polished Bronze -PB B DIA 05 (125) 06 (150) 08 (205) 10 (255) H 2 (51) 2 (51) 2 1/2 (64) 2 3/4 (70) MIN 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) 1 7/8 (48) MAX 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) 2 3/4 (70) VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -CV) Sediment Bucket -B Vandal Proof Screws -U Specify Type, Size & Finish eg: C06NB TILE FLANGE FUNCTION: Provides integral flange set 5/32" (4) below rim to receive floor covering. Flange may have option of tapped holes for securing pan and gasket. 7 1/27 1/2 (190) 6 6 (150) JAY R. SMITH MFG. CO. MEMBER OF MORRIS GROUP INTERNATIONAL POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com 5/32 (4) 2 (51) Chrome Plated -CP Polished Bronze -PB X MIN MAX 1 1/4 (32) 2 1/8 (54) SUFFIX -F Specify Type, Size & Finish eg: F06NB G 10-4-01 Revised Suffix-BS RN E 8-24-99 Revised TBW F 6-11-99 Revised Tables CMD E 11-4-97 Added Nickel Bronze EMB REV. DATE DESCRIPTION BY CKD. BY NOTE: Dimensions shown in parentheses are in millimeters. ASPE MEMBER OF: VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -FV) Holes in Flange -SH Sediment Bucket -B Vandal Proof Screws -U SUFFIX -AV SUFFIX -BS STRAINER HEAD w/square HINGED COVER 6 (150) 6 SUFFIX -F37-F38 3 1/8 3 1/8(79) Chrome Plated -CP Polished Bronze -PB VARIATIONS: Gasketed Water Tight Cover -GC Secured Cover -SC Secondary Strainer Grate-SG Specify Type, Size & Finish eg: BSNB ADJUSTABLE STRAINER HEAD FUNCTION: Used in a non-traffic area when a funnel type strainer head is required and space does not allow use of the 3500 series funnel. The extended rim allows use as an anti-flood and anti-splash drip pan. B B FLAPPER TYPE BACKWATER VALVE H H FUNCTION: Provides backwater protection at point where protection is needed. Chrome Plated -CP Polished Bronze -PB B DIA 05 (125) 06 (150) 07 (180) 08 (205) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) X MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) Specify Type, Size & Finish eg: AV05NB *Not available for 05" (125) size VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -F37V or F38V) SUFFIX -F37 -F38 B DIA 07 (180) 09 (230) H 3 1/4 (83) 3 1/2 (89) MIN X MAX 2 5/8 (67) 3 1/2 (89) 2 3/4 (70) 3 1/2 (89) VARIATIONS * Hinged Grate (Specify Suffix -AH) Vandal Proof Screws -U REINFORCED TRACTOR STRAINER FUNCTION: Used in finished floors where medium weight wheeled loads are anticipated and loose set non-tilt tractor grate is desired. Cast Iron -CI VARIATIONS: Flapper Type Backwater Chrome Plated -CP Valve (Specify Suffix -DV B Polished Bronze -PB or -EV) Sediment Bucket -B H Vandal Proof Screws -U SUFFIX B H X DIA MIN MAX -D 07 (180) 3 1/4 (83) 2 5/8 (67) 3 1/2 (89) -E 09 (230) 3 1/2 (89) 2 3/4 (70) 3 1/2 (89) SUFFIX -D-E Specify Type, Size & Finish eg: D09PB E09PB CL BS BS SANITARY E N G I N E E R I N G Prevention Rather Than Cure Cast Iron -CI Chrome Plated -CP Galvanized Cast Iron -G Polished Bronze -PB Specify Type, Size & Finish eg: F37NB F38CP FIGURE NUMBER 2010 SERIES OPTIONAL STRAINER HEADS 1 0f 2 Page 27 of 28

DRAWN BY: CHECKED BY: APPROVED BY: DATE: SCALE SIZE DRAWING NUMBER PJ TD TD 5-17-85 NONE PM0457 SH 2 of 2 J A 2010 SERIES OPTIONAL STRAINER HEADS FIGURE NUMBER DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE ASSUME NO RESPONSIBILIT OR USE OF SUPERSEDED OR VOID DATA SMITH CUSTOMER DRIVEN SINCE 1926 LOW DOME STRAINER B DIA 05 (125) 06 (150) 08 (205) H 2 (51) 2 (51) 2 1/2 (64) MIN 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) MAX 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) Specify Type, Size & Finish eg: G08PB SUFFIX -G REINFORCED SQUARE STRAINER FUNCTION: Used in finished floors where some light wheeled traffic is anticipated. Chrome Plated -CP Polished Bronze -PB B B SQ 05 (125) 06 (150) 07 (180) 08 (205) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) X MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) Specify Type, Size & Finish eg: K07CP SUFFIX -K JAY R. SMITH MFG. CO. MEMBER OF MORRIS GROUP INTERNATIONAL POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com FUNCTION: Used in gutters and recessed areas where excessive debris build-up is expected. Dome insures drainage even when partly covered. Chrome Plated -CP B Polished Bronze -PB H VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -GV) Sediment Bucket -B Vandal Proof Screws -U H EXTENSION ADAPTOR FUNCTION: Used when a strainer head must be raised to accommodate deeper floor fill. 3 3/4-12 3 (95) 3/4-12 MIN 2 1/2 (64) 3/4 MAX 3 3/4 (95) REGULARLY FURNISHED: Duco Cast Iron -CI Cast Bronze -CB Galvanized Cast Iron -G NOTE: Extension can be stacked for increased maximum adjustment. SUFFIX -X 4 (100) DIA 4 1/4 (110) VARIATIONS: Flapper Type Backwater Valve(Specify Suffix -KV) Sediment Bucket -B Vandal Proof Screws -U LOCATION OPTIONAL STRAINER HEADS B DIA 05 (125) 06 (150) 07 (180) 08 (205) H 2 (51) 2 (51) 2 1/4 (57) 2 1/2 (64) X MIN 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/2 (38) MAX 2 1/4 (57) 2 1/4 (57) 2 1/4 (57) 2 1/2 (64) SUFFIX -H SOLID HINGED COVER FUNCTION: Used in areas where intermittent drain use is required. Solid cover prevents intrusion of chips, saw-dust, etc., which are swept up before cover is opened for washdown. The secondary strainer prevents debris from entering the waste line. B H SUFFIX -Y-Z Specify Type, Size & Finish eg: H05CP OVERFLOW WITH STANDPIPE FUNCTION: Used as overflow drain in decorative pools, fish ponds or similar areas. Dome prevents floating objects from entering drain line. 4 1/2 4 (115) 1/2 Chrome Plated -CP Polished Bronze -PB A 6 DIA (150) ASPE RECTANGULAR STRAINER FUNCTION: Used in finished floors where light wheeled loads and or heavy foot traffic are anticipated. Chrome Plated -CP Polished Bronze -PB B x B' H 6 6(150) 2 (51) SUFFIX A X SIZE MIN MAX -Y 2 (51) 3/4 (19) 2 1/8 (54) -Z 3 (76) 3/4 (19) 2 1/8 (54) VARIATIONS: Sediment Bucket -B Vandal Proof Screws -U SUFFIX L M N P R T B x B' 4 1/2(115)x8(205) 4(100)x12(305) 5(125)x9(230) 5(125)x13(330)6(150)x10(255) 5(125)x17(430) H 2 1/4 (57) 2 1/2 (64) 2 1/4 (57) 3 (76) 2 1/4 (57) 3 (76) X MIN 1 3/8 (35) 1 7/8 (48) 1 3/8 (35) 2 1/8 (54) 1 3/8 (35) 2 1/4 (57) MAX 2 3/8 (60) 2 3/4 (70) 2 3/8 (60) 3 (76) 2 3/8 (60) 3 1/8 (79) SUFFIX -L-M-N-P-R-T 4 1/4 (110) Fig. 3580 Fig. 3581 Fig. 3590 2 1/2 2 1/2 (64) (64) J 1-17-12 Rev. Variations of Suffix -J TBW AM H 8-24-99 Revised TBW BS G 6-11-99 Revised Tables CMD F 1-22-99 T Strainer was S Strainer TBW BS E 11-4-97 Added Nickel Bronze EMB BS REV. DATE DESCRIPTION BY CKD. BY MEMBER OF: Cast Iron -CI Chrome Plated -CP Polished Bronze -PB SANITARY E N G I N E E R I N G Prevention Rather Than Cure VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -GV) Vandal Proof Screws -U Specify Type,Size & Finish eg: LNB VARIATIONS: Less Dome -LD Standpipe Height other than 6" (150) (Specify Height) Specify Type, Size & Finish eg: YCP, ZCP 6 x 2 1/2 Oval (150) x (64) 5 x 2 1/2 (125) x (64) 1 (25) SPANNER WRENCH COVER FUNCTION: Solid gas tight, vandal proof, threaded cover for areas where intermittent drain use is required. Chrome Plated -CP Polished Bronze -PB 6(150) X MIN MAX 2 (51) 3 (76) Specify Type, Size & Finish SUFFIX -J eg: J06NB ANGLE STRAINER FUNCTION: Shower room drain set at wall and floor junction. Vertical grate openings prevent drain stoppage should flat surface become covered. D Cast Iron -CI Chrome Plated -CP B C Polished Bronze -PB 2 1/2 (64) VARIATIONS: Vandal Proof Screws -U SUFFIX B C D X MIN MAX -V 3 1/2 (89) 3 1/2 (89) 4 1/2 (115) 1 5/8 (41) 2 5/8(67) -W 6 3/4 (170) 6 3/4 (170) 6 1/2 (165) 1 5/8 (41) 2 5/8(67) SUFFIX -V -W Specify Type, Size & Finish eg: VPB, WNB HEAVY DUTY ADJUSTABLE FUNCTION: Used in finished floors where light wheeled loads and or heavy foot traffic are anticipated. 6 (150) 6 SUFFIX -69 Fig. 3591 3(76) 2 3/16 (56) 5 x 2 1/2 (125) x (64) VARIATIONS: Flapper Type Backwater Valve (Specify Suffix -JV) Sediment Bucket -B 8 1/4 x 3 1/4 Oval (210) x (83) Polished Bronze -PB Rough Bronze -RB VARIATIONS: Flapper Type Backwater Valve(Specify Suffix -69V) Sediment Bucket -B Vandal Proof Screws -U eg: A06NB-69 4 1/2 (115) FIGURE NUMBER 2010 SERIES OPTIONAL STRAINER HEADS 2 of 2 NOTE: Dimensions shown in parentheses are in millimeters. Page 28 of 28