NETSIAN TECHNOLOGY VALVE SCHEDULE

Similar documents
Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Non-Spring Return EconoDrive Floating Actuator

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

3-Way Ball Valve Assemblies Using TAC DuraDrive Actuators

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

TAC DuraDrive Product Guide Direct Coupled Actuators

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

MS Application. Features. Proportional Valve Actuator General Instructions

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P1000 Series Pressure Independent Valves

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Features Globe Valve 2-Way & 3-Way Assembly Features:

MF4E MF4E

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

TAC TM Butterfly Valve Assemblies

Application. Features

VRN Dynamic Pressure-Regulating Control Valves and Actuators

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies

3-way 1/2-2 Globe Valves

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

MAx1-720x Two Position Series MFx Floating Series MSx Proportional Series

NV Direct Coupled Globe Valve Actuator

Product Announcement Connected Products PA-00637

Zone Valves and Parts (Honeywell)

Powermite 599 Series MT Series Terminal Unit Two-way Valves

STEAM INJECTION HUMIDIFIER LIVESTEAM. Submittal Drawings

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

Electronic Globe Valves

Powermite 599 Series MT Series Terminal Unit Three-way Valves

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

High Pressure 2-way 2 1/2-6 Globe Valves

VE VVG Series Electronic Two-way Valves Normally Closed

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

2-Way & 3-Way Non Spring Return Characterized Ball Valves

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

Characterized Port -CP Three-Way Ball Valves

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

MS Series MS Series MS Series

MA-5200 Series MA-5300 Series

MA40-704X Series MA41-707X Series MA41-715X Series

ELECTRICALLY ACTUATED DOUBLE SEATED IRON - 1 1/2-2

pressure independent characterized control tm

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Control, Performance and Flexibility

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

599 Series Zone Valve Bodies:

Product Cross Reference

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Type A - PICV Actuator Series

G3 (D) 3-way Globe Valve, Bronze Trim

Accessories/Kits Ball Valve Bracket Kit (includes bracket, mounting screws, shaft and handle)

Introduction. Ball Valves. Valves D

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

599 Series 2-Way Ball Valves

Electronic Ball Valve Guide Specifications

B2 Series Characterized Control Valve, Non-Spring Return Actuator

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

VBB/VBS Series Ball Valve Assemblies

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Commercial Actuator Selection Chart Non-Spring Return

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

Erie VT/VS PopTop Series Two Position Spring Return Valves

Minimum 18 in-lb Torque

SAV Electronic Valve Actuator

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

VB-7000 Series 1/2 to 2 Globe Valves

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

M9203-xxx-2(Z) Series Electric Spring Return Actuators

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

Control, Performance and Flexibility

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

VA9208-xxx-xx Series Electric Spring-Return Actuators

Minimum 27 in-lb Torque

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

M9208-xxx-x Series Electric Spring-Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

FlowCon Energy FIT System

Transcription:

NETSIAN TECHNOLOGY VALVE SCHEDULE JOB NAME: St. Joe's Hospital - Sonntag Academic Pavilion Date: 10-19-11 1911 CALC. Cv FLOW @ VALVE CAPACITY 14 1.4 ACTUAL PRESS. VALVE SIZE GPM or PSI PRESS VALVE DROP MODEL MARK (in) TYPE QTY. #/hr DROP Cv (psi) MANUF. NO. 1-1/2" 1/2 2-Way,, NSR, 24V, 70 PSI, w/ms4d- AH-1 1 1-1/2" 11/2 6083-150, CV=41.3 3 1 55 46.48 41.3 1.77 DuraDrive VS-2213-847-9-52 S 9 Page 1 of 1

2-Way Ball Valve Assemblies Using TAC DuraDrive Actuators Note: All valve sizes ANSI Class IV (0.01% of C v ) shut-off Table-6 Selection Chart 2-Way Ball Valve Assemblies with Tac DuraDrive Actuators. a Vx-2213-81x-9-P Vx-2213-82x-9-P Vx-2213-83x-9-P Vx-2213-84x-9-P Valve Assembly Part Number VF-2213-880-9-P Valve Size (in.) P Code b Actuator Models (Actuator Codes) 24 Vac 24 Vac 24 Vac Floating MF4D-6083 MS4D-6083 (841) to (849) Floating MF4E-60830-100 (880) Close-Off Pressure, psi (kpa) Two-Position MA4D-7033 (N.O.) (821) MA4D-8033 (N.C.) (831) Floating MF4D-7033 (N.O.) (821) MF4D-8033 (N.C.) (831) MS4D-7033 (N.O.) (821) to (829) MS4D-8033 (N.C.) (831) to (839) 120 Vac Two-Position MA4D-7030 (N.O.) (815) MA4D-8030 (N.C.) (817) 230 Vac Two-Position MA4D-7031 (N.O.) (816) MA4D-8031 (N.C.) (818) 1/2 1, 2, 3, 4, 5, 6, 7 130 (896) 130 (896) 130 (896) 3/4 11, 12, 13, 14, 15, 16, 17, 18 130 (896) 130 (896) 130 (896) Ball Valve Assembly Vx-2213-8xx-9-P c 1 1-1/4 21, 22, 23, 24, 25, 26, 27 41. 42, 43, 44, 45, 46 100 (689) 100 (689) 100 (689) 70 (482) 70 (482) Valve/Linkage Assembly VB-2213-500-9-P 1-1/2 51, 52, 53, 54 70 (482) 70 (482) 2 2-1/2 61, 63, 65, 66, 67 71, 72, 73, 74, 75, 76 70 (482) 70 (482) 70 (482) 70 (482) 3 82, 85 70 (482) 70 (482) a Non-spring return 2-way ball valve assemblies are shipped open, voltage rise to close. b To find the corresponding flow coefficients for these port codes, refer to "Port Codes for TAC DuraDrive Ball Valve Assemblies" on page 6. c To determine a specific part number, identify the actuator s control signal type ( A, F, or S ), actuator code, and P code. Refer to "Part Numbering System" on page 5. 10 Copyright 2006 TAC All Rights Reserved. F-27086-6

Ball Valve Specifications Table-3 Specifications for TAC Ball Valve Assemblies. Valve Assembly Series 2-Way 3-Way Mixing Vx-2213-505-9-P Vx-2213-506-9-P Vx-2213-5xx-9-P Vx-2313-505-9-P Vx-2313-506-9-P Vx-2313-5xx-9-P Ball Valve Assemblies using TAC DuraDrive Actuators VF-2213-880-9-P Vx-2213-81x-9-P Vx-2213-82x-9-P Vx-2213-83x-9-P Vx-2213-84x-9-P VF-2313-880-9-P Vx-2313-81x-9-P Vx-2313-82x-9-P Vx-2313-83x-9-P Vx-2313-84x-9-P Applications Chilled or Hot Water, up to 50% Glycol Solution Type of End Fitting NPT Screwed Size 1/2 in. through 3 in. 1/2 in. through 2 in. Valve Assembly Series Vx-2213-xxx-9-P Vx-2313-xxx-9-P Flow Type Equal Percentage Body Forged Brass (ASTM B283) Ball Nickel/Chromium-Plated Brass Characterizing Insert Glass-filled Noryl Material Stem Brass Ball Seals Reinforced Teflon Seals with EPDM O-Rings Stem Seals EPDM O-Rings Mounting Plate Glass-filled Polymer Maximum Static Pressure 360 psig (25 bar) Maximum Operating Differential Pressure Fluid (water) Temperature a Same as close-off pressures shown in Table-4 or Table-6. Refer to "Cavitation Limitations on Valve Pressure Drop" on page 30. Seat Leakage ANSI Class IV (0.01% of C v ) Minimum a Maximum Freeze protection required. 20 F (-7 C) 250 F (121 C) Same as close-off pressures shown in Table-5 or Table-7. Refer to "Cavitation Limitations on Valve Pressure Drop" on page 30. ANSI Class IV (0.01% of C v ), piped coil-side outlet to A only F-27086-6 Copyright 2006 TAC All Rights Reserved. 7

Port Codes for TAC DuraDrive Ball Valve Assemblies Table-1 2-Way TAC Ball Valve Assemblies Sizes, Port Codes, and Cv s. Table-2 3-Way TAC Ball Valve Assemblies Sizes, Port Codes, and Cv s a b 2-Way Size Port Code a C v a k vs 01 0.38 0.33 02 0.68 0.59 03 1.3 1.1 1/2" 04 2.6 2.2 05 4.7 4.1 06 8.0 6.9 07 11.7 b 10.1 11 0.31 0.27 12 0.63 0.54 13 1.2 1.0 3/4" 14 2.5 2.2 15 4.3 3.7 16 10.1 8.7 17 14.7 b 12.7 18 28.6 b 24.7 21 4.4 3.8 22 9.0 7.8 23 15.3 13.2 1" 24 26.1 22.6 25 28.4 b 24.6 26 43.9 b 38.0 27 54.2 b 46.9 41 4.4 3.8 42 8.3 7.2 1-1/4" 43 14.9 12.9 44 36.5 31.6 45 41.1 b 35.6 46 102.3 b 88.5 51 22.8 19.7 1-1/2" 52 41.3 35.7 53 73.9 b 63.9 54 171.7 b 148.5 61 41.7 36.1 63 71.1 61.5 2" 65 108 b 93.4 66 210 181.7 67 266 b 230.1 71 45 38.9 72 55 47.6 2-1/2" 73 72.3 62.5 74 101 87.4 75 162 140.1 76 202 b 174.7 3" 82 63 54.5 85 145 b 125.4 gpm C v = ----------- ΔP (where ΔP is measured in psi) k vs = C v / 1.156 m 3 h k vs = -------------- ΔP (where ΔP is measured in bar; 1 bar = 100 kpa) Denotes a full port valve, without the characterized insert. 3-Way Size Port Code a A Port C b v a k vs 01 0.33 0.28 02 0.59 0.51 1/2" 03 1 0.86 04 2.4 2.1 05 4.3 3.7 06 8.0 c 6.9 11 0.40 0.35 12 0.66 0.57 3/4" 13 1.3 1.1 14 2.4 2.1 15 3.8 3.3 16 11 cd 10.9 21 0.40 0.35 22 0.65 0.56 23 1.3 1.1 24 2.3 2.0 25 3.5 3.0 1" 26 4.5 3.9 27 8.6 7.4 28 10 c 8.6 29 14.9 12.9 30 22.3 c 19.3 31 30.8 c 26.6 41 4.1 3.5 43 8.7 7.5 1-1/4" 44 12.7 11.0 45 19.4 c 16.8 46 34.1 c 29.5 51 4 3.5 52 8.3 7.2 1-1/2" 53 13.4 11.6 54 23.5 20.3 55 32 c 27.7 56 61.1 c 52.8 61 23.9 20.7 2" 62 38.2 33.0 63 56.7 c 49.0 64 108.5 c 93.8 a gpm C v = ----------- (where ΔP is measured in psi) ΔP k vs = C v / 1.156 m 3 h k vs = -------------- ΔP (where ΔP is measured in bar; 1 bar = 100 kpa) b B port Cv is 80% of A port Cv. c Denotes a full port valve, without the characterized insert. d Previously Cv was 12.6, kvs was 10.9. 6 Copyright 2006 TAC All Rights Reserved. F-27086-6

Valve Assemblies with MF4D-608x and MS4D-608x TAC DuraDrive Actuators Actuator Specifications Inputs Control Signal and Power Requirements All 24 Vac circuits are Class 2 Part Number Control Signal Voltage MF4D-6083-000 MF4D-6083-100 MS4D-6083-000 MS4D-6083-100 MS4D-6083-020 MS4D-6083-120 MS4D-6083-030 MS4D-6083-130 MS4D-6083-050 MS4D-6083-150 MS4D-6083-060 MS4D-6083-160 a Floating 2 to 10 Vdc a 0 to 3 Vdc 6 to 9 Vdc 2 to 10 Vdc 4 to 20 madc 4 to 20 madc with field-installed 500 Ω resistor. 24 Vac ±20% or 20 to 30 Vdc Actuator Power Input Running Holding 50/60 Hz DC 50/60 Hz VA W Amps W 5.9 3.6 0.13 1.6 5.2 2.7 0.10 1.4 Connections Motor Type Outputs Electrical Mechanical Environment Temperature Limits Humidity Locations Agency Listings (Actuator) UL Mx4D-6083-0x0: 3 ft. (0.9 m) long, appliance cable, 1/2 in. (13 mm) conduit connector. For M20 Metric conduit, use AM-756 adaptor. Mx4D-6083-1x0: 10 ft. (3.05 m) long, plenum cable, 1/2 in. (13 mm) conduit connector. For M20 Metric conduit, use AM-756 adaptor. Brush DC. Timing: Approx. 85 sec. at 70 F (21 C), measured with no load applied to actuator. Position Feedback Voltage: For 0 to 3 Vdc, 6 to 9 Vdc, and 2 to 10 Vdc proportional actuators, the feedback signal is the same voltage range as the input signal. The 4 to 20 ma proportional actuators and floating actuators have a 2 to 10 Vdc feedback signal. The feedback signal can supply up to 0.5 ma to operate up to four additional slave actuators. Stroke: 93 nominal. Manual Override: Allows positioning of valve shaft, using a manual crank. Output torque rating: 70 lb-in (6.6 N-m). RA/DA Jumper ( Models): Permits selection of reverse acting or direct acting control. Position indicator: Visual indicator. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -22 to 140 F (-30 to 60 C) ambient. 15 to 95% RH, non-condensing. NEMA 1. NEMA 2, UL Type 2 (IEC IP54) with customer-supplied watertight conduit connectors. Enclosure is air plenum rated. UL 873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). Plenum rated. European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). This product fits into Installation Category (Overvoltage Category) II per EN 61010-1. cul Canadian Standards C22.2 No. 24-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. F-27086-6 Copyright 2006 TAC All Rights Reserved. 15

2-Way Ball Valve Assembly Dimensions Valve Assembly Part Number Valve Size in. P Code a Valve Dimensions in inches (millimetres) (Refer to Figure-3) A B C D 1/2 3/4 1, 2, 3, 4, 5, 7 2-3/8 (60) 6-7/8 (175) 8 (203) 2-3/4 (69) 6 3-11/32 (85) 7 (178) 8-3/16 (208) 2-7/8 (72) 11, 12, 13, 14, 15, 17 2-5/8 (67) 6-7/16 (163) 8 (203) 2-3/4 (69) 16, 18 2-5/8 (67) 6-5/8 (168) 8-3/16 (208) 2-7/8 (72) 21, 23 3-1/16 (78) 7 (178) 8-1/2 (216) 3 (76) 2-Way VF-2213-841-9-P VS-2213-841-9-P thru VS-2213-849-9-P 1 1-1/4 22, 25 3-3/4 (95) 7-3/8 (188) 8-3/16 (208) 2-7/8 (72) 24, 26 4-5/16 (110) 7-5/8 (194) 9-1/8 (231) 3-1/4 (82) 27 3-1/16 (78) 7-13/16 (200) 8-1/2 (216) 3 (76) 41, 42, 43, 45 3 (76) 5-13/32 (112) 8-7/16 (215) 3-1/8 (79) 44, 46 3-5/8 (92) 7-3/32 (180) 9-1/8 (231) 3-1/4 (82) 1-1/2 51, 53 4-11/16 (119) 7-13/16 (198) 9-1/8 (231) 3-1/4 (82) 52, 54 4-1/16 (103) 7-11/32 (186) 9-5/8 (244) 3-3/4 (95) 2 61, 65 4-21/32 (118) 7-3/4 (196) 9-5/8 (244) 3-3/4 (95) 63, 66, 67 4-15/16 (125) 7-5/8 (195) 10-3/8 (264) 4-1/16 (103) 2-1/2 71, 72, 76, 73, 74, 75 4-3/4 (121) 7-7/8 (200) 10-3/8 (264) 4-1/16 (103) 3 82, 85 5-1/16 (129) 8 (203) 10-9/16 (268) 4-1/16 (103) a To find the corresponding flow coefficients for these port codes, refer to "Port Codes for TAC DuraDrive Ball Valve Assemblies" on page 6. 3-1/2 (89) C D A B Figure-3 MF4D-608x, MS4D-608x with 2-Way Ball Valve. 16 Copyright 2006 TAC All Rights Reserved. F-27086-6

3-Way Ball Valve Assembly Dimensions Valve Assembly Part Number Valve Size in. P Code a Valve Dimensions in inches (millimetres) (Refer to Figure-4) A B C D E 1/2 1, 2, 3, 4, 5, 6 2-5/8 (67) 6-3/4 (171) 9-5/16 (237) 2-7/8 (72) 2 (51) 3/4 11, 12, 13, 14, 15, 16 21, 22, 23, 24, 25, 28 2-5/8 (67) 6-7/8 (175) 9-5/16 (237) 2-7/8 (72) 2 (51) 3-3/4 (95) 7-1/2 (191) 9-1/2 (238) 2-7/8 (72) 2-1/16 (52) 1 27, 30 3-1/16 (78) 7 (178) 9-7/8 (251) 3 (76) 2-7/16 (62) 3-Way VF-2313-841-9-P VS-2313-841-9-P thru VS-2313-849-9-P 1-1/4 1-1/2 26, 29, 31 4-5/16 (110) 7 (178) 10-7/8 (275) 3-1/4 (82) 3-1/8 (80) 45 3 (76) 7 (178) 9-7/8 (251) 3 (76) 2-7/16 (61) 41, 43, 44, 46 3-5/8 (92) 7-3/8 (188) 10-1/2 (267) 3-1/4 (82) 2-13/16 (72) 51, 52, 53, 55 4-1/2 (114) 7-3/4 (197) 10-3/8 (264) 3-1/4 (82) 2-3/4 (69) 54, 56 4-1/16 (103) 7-1/4 (184) 11-3/8 (288) 3-3/4 (95) 3-3/16 (81) 2 61, 63 3-15/16 (100) 8-7/16 (214) 11-1/4 (287) 3-3/4 (95) 3-1/8 (79) 62, 64 5 (127) 7-1/2 (191) 12-1/4 (314) 4-1/16 (103) 3-7/8 (98) a To find the corresponding flow coefficients for these port codes, refer to "Port Codes for TAC DuraDrive Ball Valve Assemblies" on page 6. 3-1/2 (89) C D E A B Figure-4 MF4D-608x, MS4D-608x with 3-Way Ball Valve. F-27086-6 Copyright 2006 TAC All Rights Reserved. 17