UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Similar documents
UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

DECOUPLING MODULE. Input to output voltage drop

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 24V, 10A, DC-UPS 1/21.

DC-UPS CONTROL UNIT SHORT-FORM DATA MARKINGS

MS General Information Extended Product Type: MS

General_technical_data Series

RX 3 M.C.B A up to 63 A

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

RX 3 M.C.B A up to 63 A

up to 63 A (1 module per pole)

DX³ RCCBs - ID 4P up to 100 A

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Bulletin 1606 Switched Mode Power Supplies

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

CS5.241, CS5.241-C1, CS5.241-S1

DC-UPS CONTROL UNIT SHORT-FORM DATA

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Switching DC Power Supply

SHORT-FORM DATA MARKINGS

INDUSTRIAL POWER SUPPLIES SFL-SERIES

POWER SUPPLY CS5.241-S1 CS5.244

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

(1,5 modules per pole)

POWER SUPPLY CS S1 CS10.481

TX³ RCCBs 2P up to 100 A

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Electronic overload relay EF65, EF96 and EF146

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

Phase + Neutral, neutral on left side

Industrial Power Supplies

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

AF40... AF96 3-pole contactors Technical data

Viking 3 - Screw connection Disconnect terminal blocks

Model DS1000/DT20 System

Cat N 3. OVERALL DIMENSIONS

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Multi-Mover Charger for model L25

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

SHORT-FORM DATA MARKINGS

Manual motor starter MS116

SBC / 2140 / Stage Battery Charger User Manual

Direct Coupled Damper Actuator Model MY6050A1001

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Compact System NRGS 11-2 NRGS Original Installation Instructions English

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SCCP PWM Charge Controller/Load Manager Owner s Manual

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 1/23 PRELIMINARY. UB-Series Related products

Thermal overload relay TF65 and TF96

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Electronic overload relays EF205 and EF370

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Direct Coupled Damper Actuator Model MY9050A1001

Solid State Relays contactor with Integrated Fuse Type RGC1F

SOLSTART Instruction Manual

c-go 24V/6A 24V/8A 24V/12A

Galaxy VM. Battery Breaker Box Installation 09/

DC Master 24/ A

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

POWER SUPPLY SHORT-FORM DATA MAJOR AGENCY APPROVALS

B Mini Contactor V Hz

Powerware Vdc Extended Battery Cabinet User s Guide.

Control Circuit Protection

DBL distribution blocks 3x1 pole

Installation and Operations Manual

SHORT-FORM DATA MARKINGS

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Manual motor starter MS132

ASL09..S 3-pole Contactors - Spring Terminals

Gavita HortiStar 1000 DE EU/US

Mini contactors B6, BC6 with 3 pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

2-channel analog input module; Pt100 / RTD; for resistance sensors

Phase + Neutral, neutral on right side

General notes. Operating conditions

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Bulletin 1606 Switched Mode Power Supplies

Operating Instructions

General technical data. Ambient conditions

Manual motor starter magnetic only MO325

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Dimensions WxHxD [mm] Weight [kg]

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

WATERFLUX 3070 Quick Start

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

Phoenix Inverter

Pneumatic Isolation Module

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Differential Pressure Transmitter

Transcription:

BATTERY MODULE Two Mounting Options: DIN-Rail or Panel/ Wall Mounting IP00 Open Type Protection Level Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included UZK12.071 With Installed Battery UZO12.07 Only Bracket Without Installed Battery 1. GENERAL DESCRIPTION The UZK12.071 battery module utilizes one nonspillable maintenance-free lead-acid battery that is assembled in one package with all the required wiring included. The UZK12 battery module is available in two different options. It can be ordered with assembled batteries or as a battery bracket without batteries, allowing for different battery options. The mounting bracket option also allows the batteries to be assembled just in time, avoiding outdated batteries due to limited shelf life. 2. DATA Battery type VRLA Lead-acid Battery design life 3 to 5 years acc. EUROBAT Battery voltage DC 12V Battery capacity 7Ah Battery current max. 30A for discharging max. 1.8A for charging Battery fuse 30A ATO fuse Temperature sensor not included Charging voltage 13.9V 13.75V 13.6V 13.45V at 10 C at 20 C at 30 C at 40 C Self-discharge rate 3%/month at 20 C Temperature range -10 C to +40 C for charging -15 C to +50 C for discharging -20 C to +50 C for storage Dimensions 155x124x112mm WxHxD Weight 3200g / 7.6lb 550g / 1.21lb UZK12.071 UZO12.07 3. ORDER NUMBERS 4. MARKINGS Battery Module UZK12.071 UZO12.07 Battery module with assembled batteries Battery module without assembled batteries Marine LVD Replacement UZB12.071 Battery replacement 12V, 7Ah 1/9

U-Series INDEX Page 1. General Description...1 2. Data...1 3. Order Numbers...1 4. Markings...1 5. Intended Use...2 6. Instructions for Disposal of the Battery...2 7. Warranty...2 8. Instructions for Battery Storage...3 9. Installation Instructions...3 10. Replacing Batteries...4 Page 11. Environment... 4 12. Terminals and Wiring... 5 13. Protection Features... 5 14. Approvals... 5 15. Physical Dimensions and Weight... 6 16. Wall/ Panel Mounting... 7 17. Recommendations for a Long Battery Life... 8 18. Mounting Orientations... 9 The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. 5. INTENDED USE This module is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this module in equipment, where malfunction may cause severe personal injury or threaten human life. 6. INSTRUCTIONS FOR DISPOSAL OF THE BATTERY Always dispose the batteries through a recycling organization. Batteries must be completely discharged before recycling. 7. WARRANTY 3 Year limited warranty except batteries which are considered a service part. 2/9

8. INSTRUCTIONS FOR BATTERY STORAGE - Do not store batteries or battery modules at temperatures higher than 25 C or performance and lifetime might change. - Do not store discharged batteries. Keep batteries fully charged! Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster then charged batteries. - Do not store batteries or the battery module longer than nine months without supplementary charging or performance and lifetime might change. PULS charges every battery before shipment from the factory. - Recommendation for supplementary charge: Every 9 months or whenever the open circuit voltage (OCV) falls below 12.6V, the battery module should be charged. Apply a charging voltage of 13.8V (at 25 C) for 72 hours. Batteries with an OCV below 12V must not be charged anymore and must be disposed. 9. INSTALLATION INSTRUCTIONS This device may only be installed and put into operation by qualified personnel. For storage, installation and operation, the requirements of the EN 50272-2 as well as other national regulations must be observed. Place the battery module in a cool area inside a cabinet and ensure sufficient ventilation for the battery. The battery module should be securely mounted on a flat surface or on a DIN-Rail. If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for inspection. The last step is to insert the battery fuse and to store the spare fuse in the designated holes of the plastic cover. WARNING Risk of electrical shock, fire, personal injury or death. - Do not short-circuit the battery poles - Observe correct battery polarity - Disconnect battery fuse before working on the battery or on the DC-UPS. Protect against inadvertent re-powering. - Make sure that the wiring is correct by following all local and national codes. - Do not modify or repair the unit. - Do not use in wet locations or in areas where moisture or condensation can be expected. Fig. 9-1 Wiring scheme Power Supply Load + - Input + - Output Battery Module DC-UPS Battery + - (+) (-) Fuse + 12V - BATTERY UZK12.071 3/9

U-Series 10. REPLACING BATTERIES Disconnect battery fuse before replacing the battery. Always dispose the battery through a recycling organization. Batteries must be completely discharged before recycling. Batteries can also be returned to PULS or the battery manufacturer. Battery replacements can be acquired through PULS. PULS also offers a list with recommended batteries in case batteries need to be acquired elsewhere. Fig. 10-1 Replacing the battery To replace battery: 1) Loosen screws (1) with only one turn. 2) Slide the mounting bracket (2) sideways. 3) Tilt the mounting bracket to the front and take it off. 4) Unplug the battery terminals. 5) Remove the battery. 6) To insert the new battery use same procedure vice versa. 11. ENVIRONMENT Operational temperature *) -10 C **) to +40 C (14 F to 104 F) for charging -15 C to +50 C (5 F to 122 F) for discharging Storage temperature -20 C to +50 C (-4 F to 122 F) for storage and transportation Humidity 5 to 95% r.h. IEC 60068-2-30 Do not energize while condensation is present Vibration sinusoidal Shock ±4mm at 16.7Hz fixed frequency for 1hour free fall from 20cm onto a wooden floor Vibration in vertical mounting orientation according to IEC/EN 61056-1 Shock with bottom down orientation according to IEC/EN 61056-1 Altitude 0 to 6000m (0 to 20 000ft) without any restrictions Degree of pollution 2 IEC 62103, EN 50178, not conductive LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for use in paint shops. *) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit. **) Frequently charging below +5 C (41 F) reduced the lifetime of the battery 4/9

U-Series 12. TERMINALS AND WIRING The terminals are IP20 Finger safe constructed and suitable for field- and factory wiring. Type Screw terminals Solid wire 2.5-4mm 2 Stranded wire 2.5-4mm 2 American Wire Gauge AWG12-10 Max. wire diameter 3.5mm (including ferrules) Wire stripping length 7mm / 0.28inch Screwdriver 3.5mm slotted or cross-head No 2 Recommended tightening torque 0.49Nm, 4.3lb.in Instructions: a) Use appropriate copper cables that are designed for minimum operating temperatures of: 60 C for ambient up to 45 C and 75 C for ambient up to 60 C minimum b) Follow national installation codes and installation regulations! c) Ensure that all strands of a stranded wire enter the terminal connection! d) Ferrules are allowed. 13. PROTECTION FEATURES Degree of protection IP 00 EN/IEC 60529 Class of protection III EN/IEC 61140 Internal input fuse 30A DC-Fuse (ATO blade type) Isolation voltage between power to chassis 1100Vac 14. APPROVALS EC Declaration of Conformity Marine The CE mark indicates conformance with the low-voltage directive (LVD) 2006/95/EC GL (Germanischer Lloyd) classified Environmental category: A Marine and offshore applications 5/9

U-Series 15. PHYSICAL DIMENSIONS AND WEIGHT Width 155mm / 6.1 Height 124mm / 4.88 Depth 112mm / 4.41 for DIN-Rail mounting; The DIN-rail height must be added to the unit depth to calculate the total required installation depth. Depth 106mm / 4.17 for wall mounting without DIN-Rail fixture Depth 116mm / 4.57 for bottom mounting with DIN-Rail fixture Weight 3200g / 7.6lb UZK12.071 550g / 1.21lb UZO12.07 Bracket material Cover: zinc-plated steel Fig. 15-1 Front view Fig. 15-2 Side view Fig. 15-3 Isometric view 6/9

16. WALL/ PANEL MOUNTING Panel/ wall mounting is possible by detaching the DIN-Rail brackets Fig. 16-1 Panel/ wall mounting Removing the aluminium brackets and plastic slide Detach the two aluminum brackets by removing the two screws with a Torx screwdriver (Torx 10). Remove the plastic lock mechanism by using a flat-blade screwdriver to move the lock downwards while pushing the plastic slide upwards at the same time. Detach the plastic slide. Panel/ wall mounting is possible by using either the four holes on the rear or on the bottom of the unit. Fig. 16-2 Hole pattern for wall mount Fig. 16-3 Hole pattern for bottom mount 7/9

17. RECOMMENDATIONS FOR A LONG BATTERY LIFE Temperature: The temperature has the most impact on the service life. The hotter the temperature, the earlier the wear-out phase of the battery begins. The wear-out results in a degradation of battery capacity. Place the battery module in a cool location, E.g. near the bottom of the control cabinet. Do not place the battery module near heat generating devices. Do not overcharge batteries! Fig. 17-1 Service life vs. ambient temperature, typ. Service Life in Years 10 9 8 7 Design Life of Battery A: 3-5 Years C B: 6-9 Years C: 10-12 Years 6 B 5 4 A 3 2 1 Ambient Temperature 20 C 25 C 30 C 35 C 40 C 45 C Number of discharge cycles and depth of discharge: Do not discharge batteries more than necessary. Set buffer time limiter to the required buffer time. The number, as well as the depth of discharging cycles is limited. A replacement of the battery might be necessary earlier. When choosing the battery capacity, always try to get the next higher capacity than required. The depth of discharge reduces the service life of the battery and limits the number of cycles. Fig. 17-2 Battery degradation vs. discharging cycles, typ. Cell Capacity 120% 100% 80% 60% 40% 20% A B C Depth of discharge A: 100% B: 50% C: 30% Number of Discharging Cycles 0 200 400 600 800 1000 1200 8/9

18. MOUNTING ORIENTATIONS The standard mounting orientation is the vertical installation onto a flat surface. Fig. 18-1 Standard mounting orientation The following mounting orientations are also allowed: Fig. 18-2 Allowed mounting orientation Do not use the battery module in an upside down position: Fig. 18-3 Forbidden mounting orientation 9/9