AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Similar documents
IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G G2080I

AUTOMATION FOR STREET BARRIERS GARD 4 SERIES INSTALLATION MANUAL G G4041I

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BK SERIES INSTALLATION MANUAL BK-1200P

AUTOMATION WITH PRATICO SYSTEM FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-P

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES

AUTOMATION FOR SWING GATES SERIES FERNI INSTALLATION MANUAL FE4024. English

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ

E R A I GATE AUTOMATION DIVISION

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG A24 / FROG A24E. English

VER KIT. Installation Instructions TECHNICAL HELPLINE

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety

unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC

BULL 424 ESA BULL 624 ESA

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Ditec PWR25H/35H Automation for hinged gates

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

BISON 20 OM BISON 25 OTI

OPERATORS FOR GARAGE DOORS FA00045-EN INSTALLATION MANUAL VER10 - VER12. English

Ditec PWR50H/HV/HR Automation for swing gates

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

INDUSTRIAL DOOR OPERATOR 119CT54EN INSTALLATION MANUAL C-BX_C-BXK_CBXE_CBXEK C-BXT_C-BXET_C-BXE24. English

TECHNICAL DATA HYDRAULIC UNIT

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

AUTOMATION FOR SLIDING GATES INSTALLATION MANUAL BK BKE

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Ditec CUBIC Swing gates automation

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Typical Installation Schematic

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Ditec LUXO Swing gates automation (Original instruction)

SDN4 / SDN6 / SDN8 / SDN10

ARACHNE 230V 24V- 12V

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec BOX Balanced up and over doors

SWING GATE OPENERS 24V DC GEAR MOTOR

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

INSPECTIONS AND MAINTENANCE

INSTRUCTIONS FOR INSTALLATION

AUTOMATION SYSTEMS FOR SLIDING GATES INSTALLATION MANUAL BX-246. English

Ditec PWR Automation system for swing gates with wings up to 5 metres

AUTOMATION SYSTEMS FOR SLIDING GATES BX SERIES INSTALLATION MANUAL BX-243. English

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

TURBO 40 TURBO 80 TURBO 120 TURBO 160

Automation Swing Gate Opener

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

FITTING AND CONNECTION INSTRUCTIONS

USER INSTRUCTIONS FOR SLIDING DOORS

USE AND MAINTENANCE MANUAL

GB Instructions Manual

INSTALLATION MANUAL GB

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

Cross14, Cross14E, Cross14VE, Cross15V

AUTOMATION FOR STREET BARRIERS 119GU44EN GARD 8 SERIES INSTALLATION MANUAL G2081Z. English

OPERATOR FOR STREET BARRIERS 119G56EN. Barrierline SERIES GARD INSTALLATION MANUAL G English

INSTALLER AND USER S MANUAL. v4.0 REV. 01/2019

Oil-hydraulic operator for swinging gates

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

Cable Temperature QAP... Sensor. Use

ASW-400. Installation Manual. Downee

CONTROL PANEL FOR 24V GEARMOTORS 319U33EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N. English

CP-LIFT. Plazma lift 1. LIST OF ITEMS: 2. INSTALLATION and ADJUSTMENTS: Dimention of the lift: L: 1375 mm W: 965 mm D: 236 mm

BIG Series. D_MNL0BIG Rev.18. IT - Istruzioni originali

INSTALLATION MANUAL (cod )

Ditec DOD Industrial sectional door automations

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

Cross Automations for sliding gates

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

CHECKING AND MAINTENANCE:

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

TITANO 400V SLIDING GATE OPENER

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

ASR WORMWHEEL UNLOCK DEVICE. ASR - Worm Speed Reducers types RS and RT

AUTOMATION FOR SWING GATES 119D49EN INSTALLATION MANUAL A 3000/3006/3100/3106 A 5000/5006/5100/5106. English

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080Z - G2080IZ. English

FEATURES AND SPECIFICATIONS

Transcription:

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS 1 Legend 4 Description This symbol indicates sections to be read with particular care. This symbol indicates sections concernig safety. This symbol indicates notes to communicate to users. 2 Destination and limits of use 2.1 Intended use The SUPERFROG automation system has been engineered to operate swing gates of up to 1500 kg. The use of this product for purposes other than as described above and installation executed in a manner other than as instructed in this technical manual are prohibited. 2.2 Limits to use Length of gate leaf < 4 m 4 m 5 m 6 m 7 m 8 m Weight of gate leaf 1500 kg 1200 kg 1000 kg 800 kg 700 kg 600 kg 3 Reference standards This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453. 4.1 Automation SUPERFROG was designed and manufactured by CAME CANCELLI AUTOMATICI S.p.A. and is compliant with the safety regulations in force. Guaranteed 24 months if not tampered with. The automation system is composed of a foundation box, a gearmotor and a series of arms. The foundation box is made of steel and is 1.5mm thick on the sides and 4mm thick on the bottom. It houses the gearmotor which is made of a die-cast iron case, inside of which operates an worm-screw and helical worm gear based irreversible reduction system, which is lubricated with a SINCAT type oil and features a transmission arm. 4.2 Technical specifications SUPERFROG Power supply panel: 230/400V A.C. triphase 50/60Hz Motor power supply: 230/400V A.C. triphase 50/60Hz Max. draw: 2,5 A Rated power: 600 W Max. torque: 100 kgm Opening time: 45 s (max. 95 ) Reduction ratio: 1/1800 Arm revolutions: 0.35 rmp Operative intermittence: 50% Protection level: IP67 Weight: 189 kg Insulation class: 2

4.3 Description of the parts 1 GEARMOTOR UNIT 1) Tie rod 2) Motor support assembly 3) Gearmotor 4) Cover 5) Foundation box 6) Upper arm assembly 7) Arm assembly 8) Sleeve bearing 9) Hole cover for case 10) Bracket for case 4.4 Dimensions Measurements in mm 6 7 8 9 10 2 3 5 4 3

5 Installation The installation must be carried out by export, qualified personnel in total compliance with the norms in effect. 5.1 Preliminary checks Before proceeding with the installation, it is necessary to: Provide for a suitable omnipolar disconnection device with contacts more than 3 mm apart, and independent (sectioned off) power supply; Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as compared to the other conductive parts inside; Set up a tube to serve as a draining system to prevent water build up and oxidation; Make sure that any connections inside the container (made for the continuity of the protection system) are provided with additional insulation compared to the other conductive parts inside; Make sure that the structure of the gate is sufficiently sturdy, that the hinges are in good working order and that there is no friction among any of the moving parts; Make sure there is a mechanical stop for both the opening and closing phases. 5.2 Tools and materials Make sure all tools and materials necessary are within reach to install the edge in total safety, and in compliance with the regulations in force. The following figure illustrates the minimum equipment needed by the installer. 4

5.3 Cable list and minimum thickness Connections Type of cable Length of cable 1 < 10 m L. of cable 10 < 20 m L. of cable 20 < 30 m 230/400V 3F power supply 4G x 1,5 mm 2 4G x 2,5 mm 2 4G x 4 mm 2 230/400V 3F motor power supply 4G x 1 mm 2 4G x 1,5 mm 2 4G x 2,5 mm 2 Flashing lamp FROR CEI 2 x 0,5 mm 2 2 x 1 mm 2 2 x 1,5 mm 2 20-22 Photocell transmitters 2 x 0,5 mm 2 2 x 0.5 mm 2 2 x 0,5 mm 2 CEI EN Photocell receivers 50267-2-1 4 x 0,5 mm 2 4 x 0,5 mm 2 4 x 0,5 mm 2 power supply to accessories 2 x 0,5 mm 2 2 x 0,5 mm 2 2 x 1 mm 2 Control and safety devices 2 x 0,5 mm 2 2 x 0,5 mm 2 2 x 0,5 mm 2 Antenna connection RG58 max. 10 m N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1. For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and distances. When connecting products other than those mentioned in this manual please see the documents provided with the products themselves. 1) Right-hand gearmotor unit (MD gearmotor + CD foundation box) 2) Left-hand gearmotor unit (MS gearmotor + CS foundation box) 3) Cable box for connections 4) Control panel 5) Tuned antenna 6) Movement-indicating fl ashing lamp 7) Key-switch selector 8) Safety photocells 9) Branching pit 10) Drainage pit 11) Mechanical stops 8 4 5 6 7 3 2 11 1 8 3 11 11 9 10 5

5.4 Preparing the foundation box The following applications are only examples, as the space required for unit installation and the accessories vary depending on dimensions and therefore it is up to the installer to select the best solution. Note: the following sketches show how to install the right-hand foundation box (CD). - Dig a pit to place the foundation box into, set up the required cable boxes and corrugated conduits for the connections coming from the branching pit and the drainage tube. Note: the number of cables depends on the type of system and the accessories installed. - Level the foundation box with the ground and position the pinion of the foundation box in line with the top hinge of the gate. - Fill the pit with concrete and sink the foundation box into it, making sure that the corrugated and drainage tubes pass through the proper holes. 6

- Lubricate the pinion of the foundation box, the sleeve bearing, the arm assembly and the upper arm assembly. Follow the diagrams to assemble properly. Arm assembly Pinion Sleeve bearing Upper arm assembly - Place the gate leaf above the upper arm assembly making sure that the hinge is secured properly. Properly weld the gate leaf to the upper arm assembly. 7

5.5 Installing the motor unit N.B. the diagrams that follow show an outer view so as to make the (MD) right-hand gearmotor installation more intuitive. - Place the gearmotor into the foundation box and fasten it with nuts and washers using the crow s foot wrench supplied and the proper ratchet wrench. UNI 5588 M12 UNI 6592 Ø12 - Fasten the tie rod between the motor support and the arm assembly with nuts and bolts in the proper holes. UNI 7474 M12 UNI 5739 M12x80 UNI 5739 M20x50 Note: the arms are fi tted with several holes to enable different gate-leaf opening angles. OPENING 90 OPENING 95 8

- When the gate leaf is in the closed position, adjust the box bracket until it stops against with the motor arm assembly and fasten it. - Rest the cover on top of the foundation box, fi x the hole cover into place and insert the cap into the cover. Hole cover for case 5.6 Manual release of the gearmotor Cover - Remove the cap, loosen the motor arm assembly screw by turning it counterclockwise to move the gate leaf manually. UNI 5933 M6x12 Cap 9

6 Connecting up to the control panel Electrical connection for 400V gearmotor. ZA2S Control panel Power rating 400V A.C. triphase 50/60Hz Power rating 230V A.C. triphase 50/60Hz BROWN BLACK BLUE Connection for the delayed opening 400V A.C. gearmotor Electrical connection for 230V gearmotor. ZA2S Control panel BLUE BLACK BROWN BROWN BLACK BLUE Connection for the delayed opening 230V A.C. gearmotor When performing electrical connections, it is always advisable to do so using the branching pit or the cable boxes. For further guidance on functions and settings, read the technical documentation of the control panel. T Connection for the delayed closing 400V A.C. gearmotor T R R BLACK BLUE BROWN S S BLACK BLUE BROWN BLUE BLACK BROWN 10 Connection for the delayed closing 230V A.C. gearmotor

7 Maintenance The unit does not require specific maintenance. Only as a precautionary measure and in case of intensive use, we recommend periodically checking (every 6 months) on the state of the electric wire connected to the motor, the tightness of the nuts and the proper oiling of the sliding points between fixed and mobile parts. All checks must be recorded (in a dedicated record-book). 8 Demolition and disposal In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certified in compliance with the UNI EN ISO 14001 standard to ensure environmental protection. Please continue our efforts to protect the environment which CAME considers one of the cardinal elements in the development of its operational and market strategies simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING The packaging components (cardboard, plastic, etc.) are all classifiable as solid urban waste products and may be disposed of easily, keeping in mind recycling possibilities. Prior to disposal, it is always advisable to check specific regulations in force in the place of installation. PLEASE DISPOSE OF PROPERLY! PRODUCT DISPOSAL Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c recyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, etc.), however, may contain polluting substances. They should therefore be removed and given to qualified service companies for proper disposal. Prior to disposal, it is always advisable to check specific regulations in force in the place of disposal. PLEASE DISPOSE OF PROPERLY! 9 Manufacturer s warranty CAME Cancelli Automatici S.p.A. via Martiri della Libertà, 15 31030 Dosson di Casier - Treviso - ITALY tel (+39) 0422 4940 - fax (+39) 0422 4941 internet: www.came.it - e-mail: info@came.it Declares under its own responsibility that the equipments for automatic garage doors and gates listed below: DRIVERS FOR SWING GATES FROG-MD / FROG-CD / FROG-MS / FROG- CS comply with the National Law related to the following European Directives and to the applicable parts of the following Standards. 98/37/CE - 98/79/CE MACHINERY DIRECTIVE 98/336/CEE - 92/31/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 73/23/CEE - 93/68/CE LOW VOLTAGE DIRECTIVE 89/106/CEE CONSTRUCTION PRODUCTS DIRECTIVE EN 13241-1 EN 12635 EN 61000-6-2 EN 12453 EN 12978 EN 61000-6-3 EN 12445 EN 60335-1 EN 60204-1 Reference code to request a true copy of the original: DDF B EN A003 ver.1.0 MANUFACTURER S DECLARATION OF CONFORMITY Pursuant to annex II B of the Machinery Directive 98/37/EC IMPORTANT WARNING! Do not use the equipment specified here above, before completing the full installation In full compliance with the Machinery Directive 98/37/EC MANAGING DIRECTOR Mr. Andrea Menuzzo 11

CAME UNITED KINGDOM LTD UNIT 3, ORCHARD BUSINESS PARK TOWN STREET, SANDIACRE NOTTINGHAM - NG10 5BP - U.K. Tel 0044 115 9210430 Fax 0044 115 9210431 Cod. 119AU03 ver. 0.1 07/06 CAME CANCELLI AUTOMATICI