Installation & Operation Manual

Similar documents
RAY TYPE 1 PRODUCT MANUAL

USER MANUAL MPS 1-5KW SERIES

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

Operating Instructions BNT-40 Automatic Rebar Tying Machine

MODEL SPS, SR7X SERIES

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

2 Water + Additives kg/h Steam, 4-6 barg kg/h Carbon Black pellets kg/h 9540

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

SPEEDRIVE INSTRUCTIONS MANUAL

Bucket Elevator Belt Bucket Conveyor

PNL-MS Belt Conveyor with Metal Detector

PART7. Trouble Shooting

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Differential Pressure Transmitter

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

GES-80 Series Conveyors Operating Manual

GES-50 Series Conveyors Operating Manual

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

Rotary vane air compressors for industry. Industry s advantage. with Hydrovane.

BRUSHLESS BLOWER 60DCF DCF DCF-478. Instruction Manual

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

Operating Manual for the models

maintenance of the winch. All information in this publication is based on the latest production information available at the time of printing.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

Welding Positioner Model: LD-60R/150R/300R

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

PURE SINE WAVE DC TO AC POWER INVERTER

ECONOMISER SERIES E2T USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

EX Series. Electric Actuators for Ball and Butterfly Valves

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Industry s advantage. with Hydrovane. aircarecompressors.co.uk. Rotary vane air compressors for industry

ALWAYS SAVE THIS BOOK FOR FURE REFERENCE.

Owners Manual for TPMS plus GPS

3KW Off-grid Solar Power System LFP Battery

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SYSTEM 4000 TRIMMER DBM-400T

GAL-80 Series Conveyors Operating Manual

58kHz AM Deactivator DB104 Instruction Manual V1.0

INTELEPOWER CXS SWITCHING SYSTEMS

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

MOTOR CITY ROCKERZ INSTALLATION MANUAL Part # ROCKRHYD[... ] ROCKRELE[... ] (ALL COLORS)

ROGERS MACHINERY COMPANY, INC

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

G861 Series Integrated Function. Direct Spark Ignition Control

OPERATING INSTRUCTION

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

1600 PSI ELECTRIC PRESSURE WASHER

GE.PK.022/020.SS+0_all

Signature Series. Duplex Softener Service Manual

Safety Design of CHAdeMO Quick Charging System

ROTARY Point Level Measurement for Inventory Control

XS400 Load Bank. Read all instructions before using the load bank. Contents

Linear Commutated Meat Filler IMC-CMF100 INTERNATIONAL MACHINE CONCEPTS WELCOMES YOU TO YOUR NEW MACHINE

Filterpack FR-BFP2-(H)0.4K to (H)15K

OPERATION MANUAL M185. MIG/flux wire feeder welder. Serial Number: Where Purchase: Date of purchased:

Electric Vehicle Charging Station

Semi-automatic Thermal Sealer

General Precautions. Personnel Precautions

DL (AZD1) Mini Limit Switches

PO W ERCO N H A N D LIN G SYST EM S (PT Y) LT D.

BRAVER UPS. (Uninterruptible Power System) User s Manual

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Pure sine wave charger inverter Product Manual

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Pure Water. Anytime, Anywhere. Marine Desalination Systems

V1504 Vertical Platform Lift OWNER S MANUAL

INSTRUCTION MANUAL. NTN Bowl Feeder Type K10/K14/K16/K20. PMPH001E-f. Before use. Introduction. 1. Before Use. Contents

SNMP dedicated to ORVALDI Solar Infini

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Quick Start Guide TS 910

CA 6550 Owner s Guide

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

1 / Genset general description

1 / Genset general description

WASH SYSTEM. Instructions for Use

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

F3S-TGR-KM15/-KM16/-KH16

230V 60Hz LINE FUSES AM CLASS:

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

FIELD POWER 190 DIESEL WELDING GENERATOR. Operation Manual

G72x Series Direct Spark Ignition Controls

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

Transcription:

GFR30 ROTARY TYPE POWDER FILLING & CAPPING MACHINE Installation & Operation Manual

1. Summarize GFR30 rotary type powder filling machine is arranged the container by conveyor belt and send to station for below operation. Powder filling (filling volume is controlled by a set of servo motor, it all set on touch screen) 2,Main Parameters Capacity Hopper bulk Auger servo motor 20-40 bottles/min(100g) 30L 0.75KW Stirring motor 250W 1:20 Star wheel motor 550W 1:40 1:20 Conveyer motor 180W 1:30 transducer timing Power supply 380V 3PH 10A Weight 550Kg 3 Installation & adjustment 3.1 Placement Select an indoor place which should be flat and dry. Adjust the 4 bottom legs to place the machine steadily. The machine should be away from strong interference source such as welding machine, strong signal source, etc. 3.2 Working condition: 5-30. None dew. 3.3 Preparative work 3.3.1 Connect to compressed air supply Connect the self-provided 5Kg/cm2, 0.3m³/min gas to the air supply input mouth on the backside of the main machine. Regulating valve has been adjusted before sold. Check it before use. 3.3.2 Power supply: This machine use 3 phase 380V 50Hz power. User self-provided 20A switch as main power supply switch. Make sure the earth wire is reliable and meets the demand of electric devices, otherwise the safety of the machine and personal will not be guaranteed. 4. Introduce for operation panel& touch screen

4.1 Panel 1.Vibrating switch; 2. Vibrating adjusting; 3. Start button; 4. Emergency button; 5. Touch screen ; 4.2. Touch screen 4.2.1 Enter menu Note:press and switch to main menu 4.2.2.;

4.2.2. Main menu 1--------Press and switch to AUTO menu 4.2.3.; 2------- Press and switch to MANUAL menu 4.2.5.; 3------- Press and switch to parameter menu 4.2.6.; 4.2.3.AUTO menu 1----------- Input filling volume you need. 2------------Press and increase filling volume. 3------------Press and decrease filling volume. 4------------Input fact filling volume; 5------------Confirm the fact filling volume; 6------------Display current filling volume; 7------------ Press and switch to output clear menu 4.2.4. 8------------ Alarm display 9------------ Start to auto running. 10----------- Stop auto running. 11----------- Press and switch to manual menu 4.2.5. 12-----------Press and switch to parameter menu 4.2.6.

4.2.4. Output clear menu 1---------- Confirm to clear current output,and turn off current menu; 2---------- Turn off current menu; 4.2.5.Maunal menu 1------------ Once filling button; 2-------------Star wheel step motor; 3-------------Leak proof; 4-------------Press and switch to AUTO menu 4.2.3.; 5------------- Press and switch to PARAMETER menu 4.2.6.; 4.2.6. Parameter Menu

1---------Set the speed of filling servo motor; 2-------- Set the speed of star wheel servo motor; 3---------Press and switch to Auto menu 4.2.3.; 4--------- Press and switch to Parameter save menu 4.2.7.; 5--------- Press and switch to Manual menu4.2.5.; 4.2.7 Parameter save menu 1------------Input parameter number; 2------------Press and switch to confirm menu 4.2.8.; 3------------ Press and switch to confirm menu 4.2.8.; 4------------ Press and switch to parameter save menu 4.2.7.; 4.2.8. Confirm menu 1------------Confirm to save or transfer parameter 2------------Cancel save or transfer menu, and close menu. 5.Alarm content & solution 5.1. STARWHEEL OVERLAOD!

Instruction:Star wheel is overload. Solution: Clean up the foreign matter in star wheel and rotary star wheel to reposition; Check does the manual handle fail to be moved away; Check the star wheel overload or not and check the manual handle detecting sensor; 5.2. AIR LOW! Instruction:Compressed air pressure lower than machine allowed. Solution: Check compressed air; Check compressed air pipe for any leak; Check compressed air sensor; 5.3. NO BOTTLE! Instruction:No enough bottle at inlet 1#. Solution:Check conveyor belt running; Check 1# bottle supply; Check 1# in-feed sensor; 5.4.BOTTLE BLOCK! Instruction:Too many bottle jam in outlet Solution:Check conveyor belt; Check back end machine; Check the out feeding sensor; 5.5. CONVEYOR FALSE! Instruction:Conveyor belt abnormal. Solution:Check conveyor belt for any foreign matter; Check conveyor belt transducer; Contact with manufacturer; 5.6. DOOR FAULT! Instruction: Door alarm. Solution:Check the door open or not. Check the door detecting sensor ; 6. Precautions and daily maintenance 6.1.This machine is connected to power according to the ensured power that customers ordered. Please notice the power sign at the back of the machine. The earth connection must be reliable, otherwise it may cause danger. 6.2. The use and operation shall be in accordance with the operating sequence. 6.3. The maintenance and service should be operated by professional.

6.4. The machine box must not be opened after the machine starts to run. The power must be cut off when doing maintenance or Check. 7.Transportation and Conservation 7.1. Never tumble the machine or expose the machine to wet environment during transportation. 7.2. The storage humidity of the machine is below 80% and the machine must not be placed outdoor. 8. Open-Box inspection and Guaranteed 8.1. When users open the box to Check before acceptance. If the transportation is fine and the package is intact, users find the parts and the components don't conform to the packing list. They are advised to contact the department of supply and marketing in our company. 8.2. Users are strongly recommended to get a full knowledge of the installation, environment, adjustment and operation that are referred to in the operation manual so that losses and accidents can be avoided. 8.3. Under the condition that the transportation, installation, usage and maintenance are well done, if there are quality problems of the product, please contact the quality inspection department in our company during guaranteed time. The guaranteed duration for free repair of our company for this product is one year.