ELECTRONIC FLUORESCENT BALLASTS

Similar documents
ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

Performance and Efficiency

HIGH FREQUENCY ELECTRONIC BALLASTS

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Lighting Electronics Atlas

Reduce Maintenance Costs *

ELECTRONIC FLUORESCENT BALLASTS

High performance for high ceilings

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

Electronic Fluorescent Ballasts

ELECTRONIC FLUORESCENT BALLASTS

EnergyCalc. Saving energy with sustainable lighting solutions from Grainger

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

Electronic Ballast Update. Schaedler/YESCO EXPO 2008 Presented by Rock Weinrich, Joseph E. Biben Sales Corporation

The right components for your application

ICN2S40N35I Ele Ballast (2) F40T V

INSTANT START BALLASTS

LED Linear Lamp. 2, 3, 4, 5 lamps. Performance Specifications. LED T8 and T12 lamps

Input Power (Watts) (min/max)

The power behind today s lighting designs

SuperDim Analog Dimming

Table of Contents T8 Instant Start Ballasts

Input Power (Watts) (min/max)

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

ELECTRONIC HID BALLASTS

RZT2S54 Electr DMMG Ballast

SuperDim Analog Dimming Technical Product Information

Input Power (Watts) (min/max)

RELB2S40N35I (2)F40T12 120V Ele BLST

Compact SE Overview. High-Performance Dimming. Ballast

Input Power (Watts) (min/max)

Input Power (Watts) (min/max)

Compact SE Overview. High-Performance Dimming. Ballast

Most reliable standard, energy-efficient solution

Lighting The Way. Ballast Specification Guide

Input Power (Watts) (min/max)

2001 TMT Associates 1

Emerging Lighting Technologies IEEE - March 21, 2001

Ballasts For High Intensity Discharge Lamps

Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps. Philips T8 Collection

SubstiTUBE IPS LED T8

Input Power (Watts) (min/max)

56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof

Troubleshooting & Maintenance for Linear Fluorescent Lighting

1992 Energy Policy Act A Pacific Energy Center Factsheet

ELECTRONIC FLUORESCENT BALLASTS

FDBT S 32W120V DM Bal

ELECTRONIC FLUORESCENT BALLASTS

Induction lamps and control gear

MAGNETIC HID BALLASTS

Metalux SNLED LENSED LED

LED LINEAR TUBE AFFORDABLE

Lessons Learned in Lighting Equipment Testing in the Philippines

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

HOW IS LIGHT PRODUCED

The right components for your application

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

LE Fluorescent Ballast

HIGH INTENSITY DISCHARGE BALLASTS

LED T8 GLASS 3WAY TUBE

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

SEQUOIA KUMHO ELECTRIC USA, INC. New T8 Lamp Outlasts and Outperforms any T8 in the Market. Huge Energy Savings

Input Current (Amps) Input Power (ANSI Watts)

Metalux SNLED LENSED LED

PrevaLED Line High Flux

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

14W Linear 2' LED Light Lumens - IP66 - UL 1598A - Stainless Steel Mounting Brackets/Hardware

Ballast Compatibility List and Guide Eco-Fit T8 Tube Lamps

Solar Powered Explosion Proof LED Lighting - C1D1-2ft, Dual Lamp Fixture - Day/Night Sensor

Understanding Electronic UltraMax HID Ballasts

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW

Product Description. MASTER PL-S 2 Pin

Specification Sheet: Uni-Fit T8 LED Tubes. Indoor. 177 Broad Street, 12th Floor, Stamford, CT T rvlti.com

Understanding Electronic UltraMax HID Ballasts

Lithium Polymer Battery Packs for RC Use FAQ s By Chris Nicastro 3/9/2012

Specification Sheet: EcoPark LED Parking Garage Fixture. Indoor/Outdoor

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting

4' Planar Suspended and Surface LED Light Level Outputs. Lumens Delivered. Efficacy (LPW)

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

and Refrigeration Institute). CNX Special Purpose Contactors

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW

EcoSystemR Multiple Control Input Ballasts

Solar Powered 10 Watt LED Light - 12 Hour Run Time - Day/Night Photocell or Motion Sensor

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

*RENTAL* 12/24 Volt Explosion Proof LED light - Class 1 Div 1 & Class 2 Div 1 - Paint Spray Booth

ELECTRONIC HID BALLASTS

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

HSN, HSM, HIS, IC, TN, CC and IW Series

Transcription:

ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1

ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic ballasts for a broad range of T5 and T8 lamps Optanium ballasts for T5 and T8 lamps are part of our effort to promote environmental responsibility through Smart Solutions - energy efficient products, lighting systems, services and expertise through Philips dvance branded products. They are also one of the charter products of the NEM Premium allast Program. ll of this makes these ballasts part of an overall high-efficiency lighting system that may help you achieve LEED certification, meet SHRE standards, become compliant with California Title 24 Energy Efficiency Standards, or any other local energy code you or your customers need to be in compliance. Optanium ballasts will help you and your customers meet a variety of application challenges including luminaire design, installation, maintenance, and evolving lamp technology. Optanium ballasts are available in a standard light output, low-watt, and a high light output design. lso these ballasts come in options with cold-starting capability down to -20 F (with standard fluorescent lamps). These two features combined make it ideal for just about any T5 or T8 fixture design and application. These ballasts are available in either instant start or programmed start ignition for extended lamp life in frequent switching applications such as those where occupancy sensors or motion detectors are being used. Optanium ballasts are also available in program start with parallel wiring. Setting Industry Standards for allast Efficiency s a charter product in the NEM Premium allast Program, Optanium ballasts are recognized as supporting energy-efficient lighting objectives. The National Electrical Manufacturers ssociation (NEM) has created this program to help lighting professionals and end users recognize the market s highest-performing ballast products. For more information on the NEM Premium allast Program, visit www.philips.com/advance and click on the Sustainability tab. Striation-reduction technology Reduces the likelihood of striation often associated with energy-saving lamps, for consistent light output Cold temperature lamp ignition down to -20 F for instant or program start ballasts rings energy-efficient T5 and T8 performance to a variety of new applications such as parking garages, warehouses, and cold storage areas rc-reduction technology UL Type CC UL Type CC* (on certain ballasts) Program start parallel (P) Program start ballasts with parallel wiring delivers independent lamp operation preventing premature lamp shut down ultimately reducing maintenance High efficiency design Maximize energy savings with improved ballast efficiency The following ballasts are NEM Premium : IOP-1P32-SC IOP-1P32-LW-SC IOP-2P32-SC IOP-2P32-LW-SC IOP-2P32-HL-SC IOP-1P32-SC IOP-1P32-LW-SC IOP-2P32-SC IOP-2P32-LW-SC IOP-2P32-HL-SC s a licensee in the NEM Premium allast Program, Philips Lighting s has determined that these products meet the NEM Premium specification for premium energy efficiency. 1-4

ELECTRONIC FLUORESCENT LLSTS allast Fundamentals The job of a ballast In all fluorescent lighting systems, the ballast s basic tasks include: Providing the proper voltage to establish an arc between the two electrodes. Regulating the electric current flowing through the lamp to stabilize light output. In some fluorescent lighting systems, the ballast also provides a controlled amount of electrical energy to preheat or maintain the temperature of the lamp electrodes at levels specified by the manufacturer. This is required to prevent electrode filaments deteriorating prematurely and shortening the lamp life. s For many years there were only three types of lighting systems: preheat, rapid start and slimline instant start. With the introduction of electronic ballasts, two additional types of lighting system circuits have been added: instant start for T8 lamps and programmed start. Each requires a special ballast design to operate the lamps in the circuit properly. Instant start electronic ballasts start lamps without delay (<0.1 seconds) or flicker by providing a starting voltage that is sufficiently high to start a discharge through the lamps without the need for heating lamp electrodes. For F32T8 systems, the starting voltage is about 600V. The elimination of electrode heating maximizes energy savings typically saving 2W per lamp compared to rapid start ballasts. Instant start ballasts are best suited for applications with limited switches each day. operated by instant start ballasts typically operate,000 to 15,000 switch cycles before failure. Rapid start electronic ballasts start lamps quickly (0.5 1.0 seconds) without flicker by heating the lamp electrodes and simultaneously applying a starting voltage. The starting voltage of about 500V for F32T8 systems is sufficient to start a discharge through the lamps when the electrodes have reached an adequate temperature. Electrode heating continues during operation and typically consumes 2W per lamp. operated by rapid start ballasts typically operate 15,000 to 20,000 switch cycles before failure. Programmed start electronic ballasts also start lamps quickly (1.0-1.5 seconds) without flicker. Programmed start ballasts are designed to maximize lamp life in frequent lamp starting applications such as in areas where occupancy sensor controls are used. Programmed start electronic ballasts precisely heat the lamp electrodes, tightly controlling the preheat duration before applying the starting voltage. This enhancement over rapid start ballasts minimizes electrode stress and depletion of emitter material, thereby maximizing lamp life. operated by programmed start ballasts typically operate up to 50,000 switch cycles before failure. Circuits Series vs. Parallel. Lighting systems are typically wired in a series or parallel circuit. When a ballast is operating multiple lamps in a series circuit, if one lamp fails, the circuit is opened and all the lamps will extinguish. When a ballast operates multiple lamps in a parallel circuit, the lamps operate independently of each other so, if one lamp fails, the others can keep operating as the circuit between them and the ballast remains unbroken. s a general rule, rapid start ballasts are wired with the lamps in series. Programmed start ballasts are also typically wired with lamps in series. However, some three- and four-lamp ballasts feature series-parallel operation; so that when a single lamp in one branch fails, the lamp(s) in the parallel branch will continue to operate. Instant start ballasts are typically wired with the lamps in parallel. The Language of allasts Voltage (dedicated vs. multi). Most ballasts are designed to operate at specific voltages. Newer electronic ballasts, including Philips dvance models that use IntelliVolt technology, offer much greater flexibility and other advantages such as inventory reduction. Today s increasing demands on electrical utilities can cause wide voltage variations during load demand changes which in turn cause light output from lamps operated on dedicated electronic and electromagnetic ballasts to vary with the input voltage changes. With IntelliVolt technology, many Philips dvance ballasts maintain constant light output through nominal input voltage ranges of 120 to 277 volts, thereby compensating for any change in input voltage. Some ballasts operate from 277 to 480 volts or 347 to 480 volts. Watts/NSI Watts. watts published by ballast manufacturers are the total watts consumed by both the ballast and the lamps it operates. NSI watts are the rating given for a ballast measured under the strict testing procedures specified by NSI standards and are a dependable measure of this lamp/ballast performance. Energy savings can be determined by comparing the input watts of different lighting systems. watts may be affected by tolerance build-up from the ballast, lamp, input voltage and ambient temperature. The input watts published in this catalog are for nominal conditions only. allast (F) is the ratio of light output from a lamp operated on a commercial ballast to the light output of that same lamp operated on a reference ballast as specified by NSI standards. Light output ratings published by lamp manufacturers, are based on this reference ballast. F = light output of lamp operated on commercial ballast light output of lamp operated on reference ballast F is a measure of light output best thought of as a multiplier. Multiplying the F times rated lumens will determine actual light output of a given system operated on commercial ballasts. allast Efficacy (EF) is the ratio of ballast factor to input watts. This measurement is generally used to compare the efficiency of various lighting systems higher numbers being more efficient. allast Efficacy = allast x 0 Watts This comparison is only valid, however, for ballasts operating the same number and type of lamps. In order to compare different types of lighting systems, the lumen output of the lamps must also be used. Fluorescent allasts 1-7

ELECTRONIC FLUORESCENT LLSTS T8/ES Fluorescent allasts For 25W-48" 3 4 F32T8/ES (25W - 48") IOP-3S32-LW-SC IOP-3S32-SC 120-277 Optanium 70-69 0.97 0.59-0.26 OP-3P32-LW-SC 58 0.77 0.17 347 Optanium OP-3P32-SC 64 0.88 0.19 IOP-4S32-LW-SC IOP-4S32-SC 120-277 Optanium 124-122 1.19 1.05-0.45 allast 347 Optanium NSI 74 allast 0.81 0.95 58-57 0.77-64 0.87 95-93 1.20 62-61 0.85 1-0 1.27 TD 0.71 70 0.88 57-56 0.71 67-66 0.89 77-75 0.77 87-85 0.87 TD 0.71 74-73 0.71 90 0.88 87-85 0.87 78 0.78 89 0.88 HIH POWER FCTOR (mps) 0.49-0.21 0.55-0.24 0.79-0.35 0.52-0.22 0.85-0.37 TD 0.59-0.26 0.48-0.21 0.56-0.25 0.19 0.21 0.-0.28 0.73-0.31 TD 0.75-0.33 0.73-0.31 0.22 0.26 TD 66 66 Refer to page 1-41 and 1-42 for dimensions Refer to page 1-47 and 1-48 for wiring diagrams 1-50

ELECTRONIC FLUORESCENT LLSTS T8/ES Fluorescent allasts For 28W-48" allast NSI allast HIH POWER FCTOR (mps) F32T8/ES (28W - 48") 3 4 120-277 Optanium IOP-3S32-LW-SC IOP-3S32-SC IOP-4S32-LW-SC IOP-4S32-SC 64-63 0.77 72-71 0.87 99-97 1.20 69-68 0.85 79-78 0.97 7-6 1.24 TD 0.71 75 0.88 62-61 0.71 72-71 0.89 62 0.77 70 0.88 70 0.81 79 0.97 84-82 0.77 96-94 0.87 120-277 Optanium 1-129 1.19 1.-0.47 TD 0.71 80-79 0.71 97 0.88 97-96 0.88 0.54-0.23 0.61-0.26 0.83-0.36 0.58-0.25 0.66-0.28 0.90-0.39 TD 0.51-0.22 0.60-0.26 0.18 0.20 0.71-0. 0.81-0.35 TD 0.67-0.29 0.81-0.35 0.82-0.35 0.24 0.28 OP-3P32-LW-SC 347 Optanium OP-3P32-SC 347 Optanium 84 96 0.78 0.88 0.20 0.23 TD 66 66 Refer to page 1-41 and 1-42 for dimensions Refer to page 1-47 and 1-48 for wiring diagrams 1-52

ELECTRONIC FLUORESCENT LLSTS T8/ES Fluorescent allasts For W-48" allast NSI allast HIH POWER FCTOR (mps) F32T8/ES (W - 48") 2 120 277 120-277 Optanium RCN-2S32-SC VCN-2S32-SC ICN-2M32-MC ICN-2P32-LW-SC ICN-2P32-N ICN-3P32-LW-SC ICN-3P32-SC IOP-2P32-LW-SC IOP-2P32-LW-SC IOP-2P32-SC IOP-2P32-SC IOP-2P32-HL-SC IOP-2P32-HL-SC IOP-2S32-LW-SC IOP-2S32-SC 60 0.88 60 0.88 54 0.88 47-46 0.77 54 0.88 52 0.83 61 1.01 45 0.77 52-51 0.87 72-70 1.19 51 0.85 59-58 1.00 78-77 1.31 44-43 0.71 52 0.88 46 0.78 51 0.88 50 0.86 57 1.00 0.51 0.22 0.45-0.20 0.39-0.17 0.45-0.20 0.44-0.19 0.51-0.22 0.38-0.17 0.44-0.19 0.60-0.26 0.43-0.19 0.50-0.21 0.-0.29 0.36-0.16 0.44-0.19 0.13 0.15 OP-2P32-LW-SC 347 Optanium OP-2P32-SC OP-3P32-LW-SC OP-3P32-SC 0.15 0.17 2 21 64 * 64 * 21 64 * Refer to page 1-41 and 1-42 for dimensions Refer to page 1-55 and 1-56 for wiring diagrams 1-54

T8 ELECTRONIC FLUORESCENT LLSTS For 32W allast F32T8, FO31T8, F32T8/U6 (32W) 3 120 277 120-277 mbistar Optanium RE-4P32-SC RCN-3S32-SC VCN-3S32-SC ICN-3P32-LW-SC ICN-3P32-SC ICN-4P32-LW-SC ICN-4P32-SC IOP-3S32-LW-SC IOP-3S32-SC OP-3P32-LW-SC OP-3P32-SC NSI allast 80 0.84 125 91 0.88 91 0.88 74-73 0.77 85 0.88 80-79 0.82 93 1.00 73-71 0.77 82-80 0.87 1-7 1.18 80-79 0.84 90-88 0.97 120-119 1.26 TD 0.71 85 0.88 71-70 0.71 83-81 0.88 74 0.77 84 0.88 77 0.81 89 0.96 HIH POWER FCTOR (mps) 1.36 0.78 0.34 0.71-0.31 0.67-0.29 0.78-0.33 0.70-0. 0.91-0.39 0.67-0.29 0.75-0.32 1.02-0.44 TD 0.71-0.31 0.59-0.21 0.70-0. 0.21 0.24 0/-18 32/0 0/-18-20/-29 0/-18 347 Optanium 0.23-20/-29 0.26 The above mbistar ballasts are normal power factor and labeled For Residential Use Only TD Fluorescent allasts See pages 1-3 and 1-4 for specific SKU s that meet the NEM Premium Standard LINE LK/WHT WHITE LUE LUE LLST LINE LCK WHITE LLST LUE LUE Diag. 20 Diag. 21 Refer to page 1-41 for dimensions Refer to page 1-60 for additional wiring diagrams LINE LUE/WHITE LUE/WHITE LCK WHITE LLST Diag. LUE LUE 1-59