3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Similar documents
3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

EA / 10 / 50 Clamp Coil Adapter. Operation Manual. Version 1.00 April 2007 All product names are trademarks of their respective companies

80PK-2A Type K Immersion Probe

ANALOG INSULATION RESISTANCE TESTER

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

SOIL RESISTIVITY TESTER

BROMAN MODEL 210 CONTACT RESISTANCE TEST SET SERIES 5

Time Electronics Ins-Cal. Insulation Tester Calibration System. Technical Manual

712 RTD Calibrator. Instruction Sheet. Introduction

BroadBand PowerShield. 20 AHr Battery. User Manual

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

HIGH VOLTAGE PROXIMITY DETECTOR

Time Electronics DC Voltage Calibrator. Technical Manual

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

Infrared Thermocouple Probe

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

IAQ-CALC TM Indoor Air Quality Meter

Tachometer. English. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Indoor Air Quality Meter

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number



IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

4-20mA DC PROCESS CLAMP METER

Go to to register your product and find more information.

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

DIGITAL EARTH RESISTANCE Model KM 2030

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Hybex Microsample Incubator

180w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-1800HC14

JANDS DD-8. Technical Manual. Version 1.0

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Auto-Off & Power Hold Function

i400s Calibration Information Introduction

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

EVERLAST SMITH BENCH EVE-890. Model EVE-890. Retain This Manual for Reference OWNER'S MANUAL

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

HIGH VOLTAGE PROVING UNIT

EVERLAST EVE-840 WEIGHT BENCH

DELUXE OLYMPIC BENCH EVE Model EVE Retain This Manual for Reference OWNER'S MANUAL

Micro-OPLC Installation Guide

DC to AC Power Inverters

PY-11 Voltage & Continuity Tester

C3000 SIGNAL TRANSMITTER. Introduction

200w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-2000HC14

WEIGHT BENCH MSS-7500

MARCY WEIGHT BENCH WM-367. Model WM-367. Retain This Manual for Reference OWNER'S MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

MARCY PLATINUM MP 1105 HOME GYM

5618B Platinum Resistance Thermometer User s Guide

Kompensator External Low Voltage Heating Cable System

362 Clamp Meter. Users Manual

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

716 Pressure Calibrator

American Power Design, Inc.

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

P5510. Users Manual. Pneumatic Comparison Test Pump

INSTRUCTIONS FOR USE

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

362 Clamp Meter. Users Manual

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

MARCY DIAMOND WEIGHT BENCH MD-844

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

IVK-2155 HOME GYM. Model IVK Retain This Manual for Reference OWNER'S MANUAL

MARCY PLATINUM MP-3500 HOME GYM

DELUXE SMITH MACHINE MSS Model MSS Retain This Manual for Reference

DC to AC Power Inverters

Marcy Diamond Home Gym

WMGG-224. GOLD S GYM Multi Purpose Bench. Model WMGG-224. Retain This Manual for Reference OWNER'S MANUAL

Users Manual. Phase Rotation Indicator

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

MARCY DIAMOND ELITE SMITH MACHINE

Maximum 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence

MARCY DIAMOND ELITE OLYMPIC BENCH MD-857. Model MD-857. Retain This Manual for Reference OWNER'S MANUAL

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

3200 Series. Electrical Test Equipment Calibrator. Operation Manual

302+/303 Clamp Meter. Users Manual

OWNERS MANUAL JANUARY 2007 ISO

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

IAQ-CALC TM Indoor Air Quality Meter

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Operator Instructions for Tension Links

MIL-24/2600Q MIL-24/3200DQ

MD-3401 HOME GYM MARCY DIAMOND ELITE. Model MD Retain This Manual for Reference OWNER'S MANUAL

A Member of the. Integrated Metering Technologies

ODY-19-1 AIR PRESSURE GAUGE

SUNTURA SOLAR TRACKER

Owner s Installation Guide

IRON GRIP STRENGTH SMITH MACHINE

This manual covers the following model:

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Transcription:

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

3000RS Series Precision Resistance Standard Operation Manual Version 1.40 September 2011 All product names are trademarks of their respective companies

Guarantee and Service Transmille Ltd. guarantees this instrument to be free from defects under normal use and service for a period of 1 years from purchase. This guarantee applies only to the original purchaser and does not cover fuses, or any instrument which, in Transmille s opinion, has been modified, misused or subjected to abnormal handling or operating conditions. Transmille s obligation under this guarantee is limited to replacement or repair of an instrument which is returned to Transmille within the warranty period. If Transmille determines that the fault has been caused by the purchaser, Transmille will contact the purchaser before proceeding with any repair. To obtain repair under this guarantee the purchaser must send the instrument in its original packaging (carriage prepaid) and a description of the fault to Transmille at the address shown below. The instrument will be repaired at the factory and returned to the purchaser, carriage prepaid. Note : TRANSMILLE ASSUMES NO RESPONSIBILITY FOR DAMAGE IN TRANSIT THIS GUARANTEE IS THE PURCHASER S SOLE AND EXCLUSIVE GUARANTEE AND IS IN LEIU OF ANY OTHER GUARANTEE, EXPRESSED OR IMPLIED. TRANSMILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS. Transmille Ltd. Unit 4, Select Business Centre Lodge Road Staplehurst Kent TN12 0QW United Kingdom Tel : +44 0 1580 890700 Fax : +44 0 1580 890711 EMail : sales@transmille.com Web : www.transmille.com Transmille Ltd. Page 2

TABLE OF CONTENTS GUARANTEE AND SERVICE...2 3000RS PRECISION RESISTANCE STANDARD...4 MAIN FEATURES...4 DESIGN NOTES...5 FEATURES...5 OPERATING NOTES...6 CONNECTING TO THE 3000RS...6 CONNECTION RECOMMENDATIONS...7 SPECIFICATIONS...9 CARE & MAINTENANCE...10 Transmille Ltd. Page 3

3000RS Precision Resistance Standard The 3000RS is a dedicated precision resistance standard. The standards do not require temperature controlled air or an oil bath making the 3000RS suitable as working standards, transfer standards as well as calibration support for the 3000 series range of multi product calibrators. The stability and temperature co-efficients of the 3000RS is designed for a working environment of 18-23 C and the standard is supplied complete with a calibration certificate. Main Features 1 Ohms Reference (4 Wire connections) 10 Ohm Reference (4 Wire connections) 100 Ohm Reference (4 Wire connections) 1 kohm Reference (4 Wire connections) 10 kohm Reference (4 Wire connections) 100 kohm Reference (4 Wire connections) 1 MegaOhm Reference (2 Wire connections) 10 MegaOhm Reference (2 Wire connections) Separate Earth terminal to case ground Transmille Ltd. Page 4

Design Notes The 3000RS is built using oil filled hermetically sealed ultra high precision foil resistors from 1 Ohm to 100kOhm, and oil filled hermetically sealed ultra high precision wire wound for the 1 /10 MOhm no adjustable resistors are used within the design of this reference. Features Functions of the terminal post connections : 3000RS Terminal Post CURRENT HI CURRENT LO VOLTAGE HI VOLTAGE LO EARTH Function Input for the current source from an ohmmeter Input for the current source from an ohmmeter Measurement point for a four-wire ohmmeter Measurement point for a four-wire ohmmeter Connected to the case Transmille Ltd. Page 5

Label Reference Model Number Serial Number Information Model number reference for product Unique serial number for product Operating Notes This section details operational and environmental considerations for the 3000RS precision resistance standard. Follow these instructions when operating or storing the resistance standard. CAUTION Connecting to the 3000RS Do not apply voltages above the maximum ratings detailed below. Excessive voltage can cause permanent damage and affect the nominal resistance values of the reference. VALUE MAXIMUM VOLTAGE RATING 1 Ohm 0.5V 10 Ohms 1V 100 Ohms 10V 1kOhm 10V 10kOhms 50V 100kOhms 100V 1MOhm 100V 10MOhm 300V Transmille Ltd. Page 6

The specifications for connections with CURRENT and VOLTAGE (SENSE) require four wire connections as standard. Use these terminal posts are detailed in the section below. For the case to act as a shield the EARTH terminal must be connected to earth ground or instrument guard at some point in a calibration configuration. When connecting two or more instruments with guards, the use of a single common earth point avoids earth loops. Connection Recommendations For optimum results use two sets of low thermal test leads which are designed to reduce errors caused by thermal EMFs. Fig. 1 : 4-Wire Connection Example Transmille Ltd. Page 7

Fig. 2 : 2-Wire Connection Example Fig. 3 : Earth Connection Example Transmille Ltd. Page 8

GENERAL SPECIFICATIONS DESCRIPTION Precision decade resistance reference OUTPUTS Decade resistances from 1 Ohm to 10MOhm separate terminals for each resistor DIMENSIONS 45cm x 44cm x 9cm Specifications PERFORMANCE SPECIFICATIONS VALUE T/C STABILITY/YEAR CONNECTION (ppm/ C) (ppm) 1 Ohm 0.5 10 4-Wire 10 Ohms 0.6 5 4-Wire 100 Ohms 0.1 5 4-Wire 1kOhm 0.1 5 4-Wire 10kOhms 0.1 5 4-Wire 100kOhms 0.1 5 4-Wire 1MOhm 0.6 5 2-Wire 10MOhm 3 10 2-Wire Transmille Ltd. Page 9

Care & Maintenance The only maintenance instructions for the 3000RS precision resistance reference is periodic cleaning. See below for details on the cleaning procedure and precautions for handling. Cleaning the 30000RS To keep the external enclosure of the 3000RS in good condition, clean the outer case with a soft cloth. Do not use any liquids in cleaning the enclosure removal of surface dust is all that is recommended. CAUTION Do not use cleaning fluids or solvents for cleaning as these may damage the enclosure and affect the plastic materials used in the precision resistance standard. Handling Precautions The 3000RS is designed for mechanical stability, but should not be subjected to excessive shock or be dropped. Transportation is recommended using the original packaging with avoidance of extreme changes of temperature. Servicing Information The 3000RS is provided certified from the factory, and uses high precision nonadjustable resistance standards and are not user repairable. If the instrument is damaged it should be returned to the factory for repair and recalibration. Transmille Ltd. Page 10