Fast Charge Option (IEC 335) MegaPulse Surge Testers

Similar documents
MegaPulse 1.2x50-8 PV

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

TESTLINK COMPLIANCE WESTUSA. Remote Actuation Cable Set. Instruction Manual

GFM-200A. Instruction Manual

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

MegaPulse. Antenna Surge PF 65

MegaPulse. IMPULSE TESTER Implantable Test 1. Instruction Manual

HT-25kVdc Dielectric Withstand Tester Volts DC Output

HT Dielectric Withstand Tester Volts AC Output Volts DC Output COMPLIANCE WESTUSA. Instruction Manual

HI-POT/CONTINUITY TESTER Model PLEP01

HT-2000 Dielectric Withstand Tester Volts AC Output

Dielectric Withstand Tester

CM 5000D IN A HURRY?

Sunwize Power Ready Express Quick Start

Notice Regarding this Upgrade. WARNING! Danger Potential

Installing Power Components

Troubleshooting 3Z8 038 Rev B

Sunwize Water Pumping Kit Quick Start

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500B MOTOR CONTACTOR WITH THERMAL PROTECTION 115VAC COIL

Smart Switch Basic Kit - 24 volt ( ) Wiring Instructions

DTC P0A04 - Open Wiring Fault

SBC / 2140 / Stage Battery Charger User Manual

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

EXCOUNT-I. User s manual

POLARIS 4500 HD WINCH KIT

AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500C MOTOR CONTACTOR WITH THERMAL PROTECTION 220VAC COIL

EXTENSIVELY READ THE MANUALS AND HAVE SOME TRAINING. THIS TYPE OF CONNECTION IS NOT EVEN LISTED IN THE TM

Hydro-Sync Slide-Out System

PRO LAUNCH INSTALLATION INSTRUCTIONS

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Installation and Operation Guide for PD5100 Automatic Transfer Switch

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Installation Instructions QUICKSILVER CONSOLE SHIFTER Fits: Chevelle / El Camino

120 LED DUAL HEAD SOLAR MOTION LIGHT

Thunder Power Tarp Kit Operation

WATERFLUX 3070 Quick Start

Coachstep OWNER'S MANUAL

ComfortPoint Programmable Lon, VAV/Unitary Controllers

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

SMART-B SERIES Microprocessor Controlled Chuck Control

INSTALLATION MANUAL FOR PILOT WORKSTATION

Electrical network protection VIP30, VIP35. User s manual 12/2008

DIAMOND & WHITE SAPPHIRE TESTER

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M

Foreword

Troubleshooting Bosch Proportional Valves

INSTALLATION INSTRUCTIONS

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Assembly, Mounting And Operating Manual

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

INSTALLATION INSTRUCTIONS

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

Fan Coil Unit (FCU) Fan Motor Control

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

CS WINDOW CONTROL MODULE

1.Safe testing IMPORTANT:

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

ASL09..S 3-pole Contactors - Spring Terminals

Installation Instructions

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Item Description Qty. C Mounting Bracket Support 1 D* ECU Mount 1

945 SERIES SERVICE MANUAL

INSTALLATION INSTRUCTIONS

XpressFill XF4400/XF2200

INSTALLATION INSTRUCTIONS

PRO-M 3 MOISSANITE TESTER WITH NEW ADVANCED PATENTED UV-F1 IDENTIFICATION TECHNOLOGY

Hydraulic Through Frame Slide-out SERVICE MANUAL

Grounding Systems. Equipment Grounding & Grounded Conductors

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Electrical Installation

MODEL ELC-12/60-D BATTERY CHARGER

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

Installation Instructions

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

slotcar racing controller FAQ / Technical Info Version 1.5 How do I connect the ACD pro to an unknown track?

WF-5110R True Sine Wave Inverter

AK85B INSTRUCTION MANUAL

Product Manual MNX10015 / REV B MODEL SB142, SB242. Dual Output Series Switch Boxes

Electric Actuator Instructions

Owner's Manual. Remote Switch: Outdoor agricultural sprayer kit used to remotely turn On/Off the boom. Read this manual.

EPS/ELA-Series User Manual EPS/ELA 250W

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Igniter Unit Test ACCORD AND PRELUDE WITH HITACHI DISTRIBUTOR. See Figure 2

BREAK-SAFE Load Break & Pick-up Tool

GOMINIGO Third Brake Light Pulsar Kit. Installation Instructions

Transcription:

Fast Charge Option (IEC 335) MegaPulse Surge Testers Instruction Manual COMPLIANCE WESTUSA

Dear Customer: Congratulations! Compliance West USA thanks you for purchasing the Fast Charge option for our MegaPulse family of surge testers. Connection of this option will allow the MegaPulse to charge within the minimum time constraints as dictated by relevant Standards pertaining to the MegaPulse you have purchased. In order to use this option safely, we urge you to carefully review this manual before connection to your MegaPulse tester. Both line voltage and high voltage secondary circuits could be contacted if this option is improperly connected, and contact with either of these circuits pose the risk of serious injury or death. Compliance West USA stands by your instrument with a full oneyear warranty and free lifetime technical support. If the need arises, please don't hesitate to call on us. Thank you for your trust and confidence. Rev. 1.0 May 12, 2005 i

Table of Contents MegaPulse Fast Charge Option (IEC 335)...1 General Information...1 Description...3 Installation...7 Testing for Proper Operation...7 Removal of the Fast Charge Option...7 Technical Assistance...9 Table of Figures Figure 1 Fast Charge Option (IEC 335) Front Panel... 4 Figure 2 MegaPulse Fast Charge Option Connector... 5 Figure 3 MegaPulse Option Connector Cover... 6 Table of Tables Table 1 Fast Charge Option (IEC 335) Front Panel... 4 Table 2 MegaPulse Fast Charge Option Connector... 5 ii

iii

Section 1 MegaPulse Fast Charge Option (IEC 335) General Information The MegaPulse Fast Charge Option allows the host MegaPulse tester to charge quickly enough to satisfy minimum repetition times for tests within particular Standards. In this case, IEC 335 requires multiple surges to be applied to the EUT with a minimum pause time of 3 seconds between pulses, and the Fast Charge Option designed to allow recharging to the full capabilities of the tester within that time. There are no adjustments or controls on the Fast Charge Option (IEC 335). If the option is connected to the MegaPulse tester, the Fast Charge Option is operational. Operation of the MegaPulse is the same whether the Fast Charge Option (IEC 335) is connected or disconnected. Set the voltage knob for the voltage desired, press Charge, then press Trigger. See the MegaPulse Tester manual for more information on its operation. Connection of the Fast Charge Option (IEC 335) is simple and straightforward, but for operator safety during installation, the Installation Instructions in Section 3 must be followed. It is imperative that ALL connections between the Fast Charge Option (IEC 335) and the MegaPulse tester be made, and the Connection Cover secured, before the MegaPulse is connected to line voltage. If the Fast Charge Option (IEC 335) is disconnected, please disconnect the MegaPulse from line voltage first. Once connected, the Fast Charge Option does not pose the risk of shock. However, both line voltage and high voltage secondary circuits exist in the connections between the two enclosures. Exercise care with these wires and inspect them for damage periodically. This manual contains a general description of the option (above), installation and removal instructions, and support information. For further information regarding operation of the MegaPulse Tester, please see the MegaPulse Tester Manual. 1

Section 2 Description The Fast Charge Option (IEC 335) contains an auxiliary AC power supply which allows the MegaPulse it is connected to to charge within 3 seconds as required for the minimum rest time between repetitive cycles. MegaPulse operation is identical whether the Fast Charge Option (IEC 335) is connected or not. Charge times to 12kV are approximately 12 seconds without the Option, and approximately 2-1/2 seconds with the Option installed. Connection points on the Fast Charge Option (IEC 335) front panel are noted in Figure 1 and Table 1. All cables are supplied with the Option, and cable use is also documented in Table 1. MegaPulse testers are supplied with a covered connection terminal enclosure on its rear panel. A photo of this enclosure and connection points on the MegaPulse rear panel are noted in Figure 2 and Table 2. After connection or disconnection of the Fast Charge Option (IEC 335), the Connector Cover on the rear panel of the MegaPulse must be replaced using the four provided screws before the MegaPulse is energized. Fig. 3 shows the cover correctly installed. 3

Figure 1 Fast Charge Option (IEC 335) Front Panel ITEM NAME FUNCTION AND CONNECTION MEANS 1 Low Voltage Connection A Line Voltage A connection from MegaPulse: Separate BLACK lead 2 Low Voltage Connection B Line Voltage B connection from MegaPulse: Separate RED lead 3 Ground Lug Ground Connection point (from MegaPulse ground): Green wire terminated in closed loop connectors 4 High Voltage Connection 1 High Voltage connection 1 to MegaPulse: Pigtail from Fast Charge Option (IEC 335) 5 High Voltage Connection 2 High Voltage connection 2 to MegaPulse: Pigtail from Fast Charge Option (IEC 335) Table 1 Fast Charge Option (IEC 335) Front Panel 4

Figure 2 MegaPulse Fast Charge Option Connector ITEM NAME FUNCTION AND CONNECTION MEANS 1 High Voltage Connection 1 High Voltage 1 connection from Option: Pigtail 1 from Option 2 High Voltage Connection 2 High Voltage 2 connection from Option: Pigtail 2 from Option 3 GROUND Grounding connection point: Connect green wire from Option ground here 4 Low Voltage Connection A Line Voltage A connection: Use separate BLACK lead 5 Low Voltage Connection B Line Voltage B connection: Use separate RED lead Table 2 MegaPulse Fast Charge Option Connector 5

Figure 3 MegaPulse Option Connector Cover 6

Section 3 Installation This section describes how to install and remove the Fast Charge Option (IEC 335) from the MegaPulse surge tester. We recommend that you read the entire section carefully before beginning, as the potential for serious injury or death exists. Please be careful, we want you to be our customer far into the future. 1. Remove line voltage from the MegaPulse by unplugging the power cord from the AC power inlet on the rear panel. If this step is completed correctly, the rear panel of the MegaPulse will not have any cords connected to it. 2. Using an appropriate screwdriver, remove the cover of the Fast Charge Connector on the rear panel of the MegaPulse Surge tester. See Fig. 3 above for details. 3. Find the green with yellow stripe bonding jumper that was supplied with the Fast Charge Option. Connect it between the ground lugs on the MegaPulse and the Fast Charge option using a suitable wrench. Tighten the connections until they are snug. 4. Find the loose BLACK and RED jumper wires that were supplied with the Fast Charge Option. They are color keyed to the Low Voltage Connections on the Fast Charge Option and the rear panel of the MegaPulse. Connect them, being aware to match colors throughout the connection process. 5. Connect the High Voltage jumper wires connected to the Fast Charge Option to the appropriate terminals on the rear panel of the MegaPulse. It is imperative that polarity be observed when connecting. Connect 1 to 1 and 2 to 2. 6. Recheck all connections for polarity and make sure they are firmly connected. 7. Replace the cover of the Fast Charge Connector on the rear panel of the MegaPulse surge tester using the supplied screws. 8. Connect the power cord to the MegaPulse. Testing for Proper Operation If the Fast Charge Option is correctly connected, the full voltage on the MegaPulse front panel meter should be achieved in approximately three seconds. Please refer to the MegaPulse manual for Operation Procedures. Removal of the Fast Charge Option Should you wish to remove the Fast Charge Option from the MegaPulse tester, please follow these steps noted below. 1. Remove line voltage from the MegaPulse by unplugging the power cord from the AC power inlet on the rear panel. If this step is completed correctly, the rear panel of the MegaPulse will not have any cords connected to it. 2. Using an appropriate screwdriver, remove the cover of the Fast Charge Connector on the rear panel of the MegaPulse Surge tester. See Fig. 3 above for details. 3. Remove all connections from the rear panel of the MegaPulse Surge Tester. 4. Remove the bonding conductor and the Low Voltage cables from the Fast Charge Option (IEC 335). 5. Store these three cables in a safe place, for use when the Fast Charge Option (IEC 335) 7

is reconnected to the MegaPulse Surge Tester. 6. Replace the cover of the Fast Charge Connector on the rear panel of the MegaPulse surge tester using the supplied screws. 7. Connect the Power Cord to the MegaPulse.. 8

Section 4 Technical Assistance For Technical Assistance Phone: (800) 748-6224 Technical Assistance is available from Compliance West USA between the hours of 8:30 AM and 5:00 PM Pacific Time. Compliance West USA 2120 Jimmy Durante Blvd., Suite 124 Del Mar, CA 92014 Phone: (858) 860-0277 FAX: (858) 860-0279 info@compwest.com 9

10