Signet DryLoc ph/orp Electrodes

Similar documents
Signet DryLoc ph/orp Electrodes

Signet ph/orp Electrodes

Signet ph/orp Electrodes

Signet ph/orp Electrodes

Signet 3719 ph/orp Wet-Tap Assembly

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet 4150 Turbidimeter

* * Rev. 9 01/18 Product Manual

Signet Conductivity/Resistivity Electrodes

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet 2760 DryLoc ph/orp Preamplifier

Signet Conductivity/Resistivity Electrodes

SIGNET 2760 DryLoc ph/orp Preamplifier

Signet 3719 ph/orp Wet-Tap

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors

SIGNET 3719 ph/orp Wet-Tap

Signet 2536 Rotor-X Paddlewheel Flow Sensors

SIGNET 2750 ph/orp Sensor ENGLISH

Signet 2551 Magmeter Flow Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

General Purpose ph/orp Sensors

ph/orp Sensor Model 399 ph/orp

NEW QUICK CABLE-TO-SENSOR RELEASE,

General Purpose ph/orp Sensors

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors

TUpH Retraction/Submersion/Insertion ph/orp Sensors

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Insertion/Submersion Flow Through Sensor

Signet ph/orp Transmitter

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Low Cost Submersion and In-Line ph Electrodes

JUMO tecline HD ph and JUMO tecline HD Rd

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Orbisint CPS12/CPS12D/CPS13

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

Retractable ph/orp Sensors

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

Retractable ph/orp Sensors

General Specifications

Accessories Guide ph/orp/conductivity Sensors

General Specifications

Retractable ph/orp Sensors

General Specifications

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Dissolved Oxygen, ph, and Conductivity

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

Performance Series ph/orp Sensors

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Low Cost Submersion and In-Line ph Electrodes

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

* * Rev. F 03/16 Operating Instructions

OPERATING INSTRUCTION MANUAL

Retractable ph/orp Sensors

General Specifications

Performance Series ph/orp Sensors

Analytical Instruments Two-Electrode Conductivity Sensors

Liquid Conductivity Two & Four Electrode Sensors

Signet 2517 Brass Paddlewheel Flow Sensor * *

871PH Series ph, ORP, and Fluoride Sensors and Accessories

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes

Digital ph transmitter

Product Type Manufacturer Beginning Page Conductivity Liquid Level Controls ABB SSAC 12/2

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Performance Series ph/orp Sensors

Signet Measurement and Instrumentation

Combination ph/orp Sensor

Orbipore CPS91 and CPS91D

Digital ph transmitter

PH60 Series Premium ph Testers

SIGNET Vortex Flow Sensors ENGLISH

General Specifications

Orbisint CPS11 and CPS11D

Pasve Rotary Retraction Valve

Technical Information Ceraliquid CPS41D and CPS41

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Ceraliquid CPS42/CPS42D/CPS43

8000 Series ph/orp Electrode Platform Product Instructions

Combination ph/redox (ORP) Sensors

Measurement and Instrumentation

HI 8510-HI 8512 HI 8710-HI 8711 HI 8720-HI HI HI

INTERNATIONAL METAL ENGINEERING

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Signet 2552 Metal Magmeter

Transcription:

Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature response Easy sensor replacement using DryLoc electrode connector High temperature versions available Flat Glass Protected Bulb Mounts into standard ¾ inch threads Compatible with all ph/orp and other suppliers instruments The Signet 2774-2777 ph and ORP Electrodes feature a unique foul-proof DryLoc connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive electrodes feature a PTFE double reference junction with KNO 3 in the front chamber to block various poisoning ions such as Copper (CU ++ ), Lead (Pb ++ ), Mercury (Hg ++ ), and a large reference chamber that combine to extend the service-life. Embedded positioning of the temperature element in the ph sensing tip allows the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general-purpose applications. Due to the specially designed chambers which keep electrolyte in place, all versions can be installed at any angle, even inverted. Applications Water Treatment & Water Quality Monitoring Cooling Tower and Boiler Protection Aquatic Animal Life Support Systems Pool and Spa Control Neutralization Systems *U.S. Patent No.: 6,666,701 Tel: +44 (0) 1706 869777 E mail: sales@desal.co.uk Web: www.desal.co.uk

Specifications General Compatibility Signet Models 2750 and 2760 Operating Range 2774/2776 0 to 14 ph 2775/2777 ±2000 mv (ORP) Process Connection ¾ in., for use in reducing tees up to 4 in. Reference Electrolyte KNO 3 /KCl polyacrylamide gel Element Ag/AgCl Wetted Materials Body Ryton Reference junctions PTFE Sensing surface ph Glass membrane ORP Platinum O-rings FPM Max. Temperature/Pressure Rating Operating Temperature 0 C to 85 C 32 F to 185 F Max. Operating Pressure 6.9 bar 100 psi Higher temperature and pressure sensors are available upon request. Recommended Storage Temperature The best storage temperature for the 277x ph and ORP is 0 C to 50 C 32 F to 122 F The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line/Vertical Mounting Use the electrodes ¾ inch threads to install into pipe fitting. Electrode can be mounted at any angle. Submersible Mounting Use threads on Model 2750 or 2760; requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded extension. Temperature Sensor ph 3 KΩ or PT1000 RTD ORP none Shipping Weight 0.25 kg 0.55 lb Standards and Approvals Manufactured under ISO 9001 for Quality

ENTER ENTER Dimensions 38.6mm (1.52 in.) 38.6mm (1.52 in.) 35.5mm (1.4 in.) 35.5mm (1.4 in.) 29.2mm (1.15 in.) 29.2mm (1.15 in.) 128.3mm (5.05 in.) 128.3mm (5.05 in.) 32mm (1.3 in.) 3/4 in. NPT 0.64 mm (0.25 in.) insertion depth, typical 43mm (1.7 in.) 3/4 in. NPT 22.8mm (0.9 in.) 0.64 mm (0.25 in.) insertion depth, typical 22.1mm (0.87 in.) Flat Electrode 22.1mm (0.87 in.) Bulb Electrode Panel Mount Signet Instruments 8750 with 2760 Preamplifier 8900 9900 with 2750 Electronics Field Mount - Pipe, Tank, Wall Signet Instruments 9900 with 2750 Electronics and 3-8050 Universal Mount kit 4 to 20 ma Input 3-2750 Sensor Electronics and customer supplied Chart Recorder or Programmable Logic Controller System Overview OR Signet 2774-2777 DryLoc ph/orp Electrodes + + PLC All sold separately Fittings- Customer supplied for in-line installs Submersible Installation - Customer supplied pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads and pipe assembly** *Refer to the Signet Submersion brochure located in the K-Factors Fittings and More Kit (3-0000-709) for installation suggestions and options. See Technical Reference section for assistance in choosing the correct sensor.

Electrode Key Features and Benefits: Ryton body for chemical compatibility to most harsh chemicals. Also able to withstand high temperatures. Porous PTFE reference junctions are highly chemically resistant; resists fouling and dirt buildup. First reference chamber with KNO 3 protects Ag/ AgCl wire for a prolonged sensor life. Capillary TC (temperature sensor) embedded in tip of ph electrode for quicker temperature response. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Reference Ag/AgCl Wire Double Porus PTFE Reference Junctions DryLoc Connector Ryton Body Reference Electrolyte Chamber 1 st Reference Chamber with KNO 3 ph/orp Electrode Capillary TC Application Tips Use the flat glass electrodes for in-line ph sensor applications when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. Model 2774-2777 Ordering Notes 1) ph and ORP sensors require connection to model 2750 or 2760. 2) Conduit and mounting brackets for submersible installation must always be used (customer supplied). 3) All of these sensors can be installed upside-down. 4) Special order options may have longer delivery time. Consult your local Georg Fischer sales representative for lead times.

Operating Temperature/Pressure Graph Note: The pressure/temperature graphs are specifically for the Signet sensor. During system design the specifications of all components must be considered. In the case of a metal piping system, a plastic sensor will reduce the system specification. (psi) 150 125 100 (bar) 10.3 8.6 6.9 -HT Special Electrodes only Standard Electrodes 75 5.2 50 3.4 25 1.7 0 C -40-20 0 20 40 60 80 100 120 F -40-4 32 68 104 140 176 212 248 Please refer to Wiring, Installation, and Accessories sections for more information.

Ordering Information Mfr. Part No. Code Tip design Temperature Element ph Electrodes 3-2774 159 000 955 Flat 3K Ω RTD* 3-2776 159 000 959 Bulb with Protection 3K Ω RTD* 3-2774-1 159 000 956 Flat PT1000 RTD** 3-2776-1 159 000 960 Bulb with Protection PT1000 RTD** ORP Electrodes 3-2775 159 000 957 Flat 10 K ID resistor¹ 3-2777 159 000 961 Bulb with Protection 10 K ID resistor¹ 3-2775-1 159 000 958 Flat No T.C² 3-2777-1 159 000 962 Bulb with Protection No T.C² *3K Ohm RTD for connection to 8750 or 5700 instruments when used with the 2760 preamplifier. The 2760 preamplifier is used for connection directly to Signet 5700 Monitor or 8750 transmitter. **PT1000 RTD for connection to the 8900 or 9900 when used with the 2750 sensor electronics. The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. ¹10 K ID resistor for connection to the 8750 and 5700 when used with the 2760 preamplifier or the 8900 when used with the 2750 sensor electronics ²for use with other suppliers instruments when used with the 2760 connector Special Order Options - Please consult the factory for ph and ORP Electrodes - Options -HT and -C can only be used with the 3-2721 Preamplifier. These options cannot be used with the 2750 or 2760. -HT High Temperature and Pressure options, up to 110 C (230 F) @ 150 psig; DryLoc connector is removed and replaced with a 4.6 m (15 ft) cable. -C Remove DryLoc connector and add 4.6 m (15 ft) cable. Other cable lengths are available. -ISO ISO 7/1-R 3/4 Threaded electrodes are available. Accessories and Replacement Parts Mfr. Part No. Code Description 3-2700.395 159 001 605 Calibration kit: includes 3 polypropylene cups, box used as cup stand, 1 pint ph 4.01, 1 pint ph 7.00 3822-7115 159 001 606 20 gm bottle quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) 3-0700.390 198 864 403 ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) 3822-7004 159 001 581 ph 4 buffer solution, 1 pint (473 ml) bottle 3822-7007 159 001 582 ph 7 buffer solution, 1 pint (473 ml) bottle 3822-7010 159 001 583 ph 10 buffer solution, 1 pint (473 ml) bottle 3-2759 159 000 762 ph/orp system tester 3-2759.391 159 000 764 Adapter cable for use with 2750/2760 3-2721 198 864 610 Remote mount ph/orp preamplifier 3-2774.099 Rev C (6/13) Georg Fischer Signet LLC 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 e-mail: signet.ps@georgfischer.com Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.