General Purpose ph/orp Sensors

Similar documents
General Purpose ph/orp Sensors

NEW QUICK CABLE-TO-SENSOR RELEASE,

ph/orp Sensor Model 399 ph/orp

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

TUpH Retraction/Submersion/Insertion ph/orp Sensors

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Insertion/Submersion Flow Through Sensor

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Conductivity Sensors. Applications

General Purpose Toroidal Conductivity Sensors

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

COMBINATION ph SENSOR

Endurance TM Conductivity Sensors

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

Retractable ph/orp Sensors

Triple Junction Sensor

Combination ph/orp Sensor

ENDURANCE. Sanitary Flange Conductivity Sensors. Models 403 and 403VP. Product Data Sheet PDS /rev.A June 2005

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

Combination ph/orp Sensor

Retractable ph/orp Sensors

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

Model 385+ Instruction Manual PN February ph/orp Sensor

Retractable ph/orp Sensors

Toroidal Conductivity Sensor

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Rosemount 402 and 402VP

Signet DryLoc ph/orp Electrodes

Retractable ph/orp Sensors

Signet DryLoc ph/orp Electrodes

Triple Junction ph/orp Sensor

Instruction Manual PN /rev.H March Model 385+ ph/orp Sensor

Dissolved Oxygen, ph, and Conductivity

Signet ph/orp Electrodes

381+ Rebuildable ph Sensor. Instruction Manual LIQ_MAN_381+ January 2013

Signet 3719 ph/orp Wet-Tap

PN /rev. B April Liquid Division. Mounting Solutions

* * Rev. 9 01/18 Product Manual

SIGNET 2760 DryLoc ph/orp Preamplifier

PN October Liquid Division. Mounting Solutions

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Pasve Rotary Retraction Valve

Signet ph/orp Electrodes

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Signet ph/orp Electrodes

Dissolved Oxygen Measurement System with Air Blast Cleaner

Model Q45H/ Residual Chlorine Monitor...

For additional information, please visit our website at SENSOR SPECIFICATIONS

Signet 2760 DryLoc ph/orp Preamplifier

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 3719 ph/orp Wet-Tap

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

Accessories Guide ph/orp/conductivity Sensors

Signet 3719 ph/orp Wet-Tap Assembly

Instruction Manual PN /rev.D September 2009 Model 385. Retractable ph/orp Sensor

Instruction Manual PN /rev.G March 2012 Model 381+ ph/orp Sensor

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

Analytical Instruments Two-Electrode Conductivity Sensors

ENDURANCE Conductivity Sensors

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

Measurement and Instrumentation

Signet Conductivity/Resistivity Electrodes

8000 Series ph/orp Electrode Platform Product Instructions

Low Cost Submersion and In-Line ph Electrodes

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes

Signet Conductivity/Resistivity Electrodes

Liquid Conductivity Two & Four Electrode Sensors

871PH Series ph, ORP, and Fluoride Sensors and Accessories

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors

Performance Series ph/orp Sensors

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

High Purity ph Sensor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

Rosemount 385. ph/orp Sensors. Instruction Manual LIQ-MAN-385 Rev. E April 2017

Instruction Manual PN /rev.C June Models 140, 141, 142. Conductivity Sensor Assemblies

Digital ph transmitter

Rosemount Orifice Series Differential Pressure Flow

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Signet ph/orp Transmitter

Digital ph transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

FIELD DEVICES ANALYTICAL

General Specifications

OPERATING INSTRUCTION MANUAL

Low Cost Submersion and In-Line ph Electrodes

CANADA SENSORS TECHNOLOGY INC.

Performance Series ph/orp Sensors

Baumann 24000S Stainless Steel Control Valve

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Rosemount TM 242 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-242 Rev. F June 2017

Transcription:

General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double junction reference. Enhanced performance and increased life with minimized glass cracking provided by field-proven AccuGlass ph glass formulations. VP8 quick cable-to-sensor release, provided by the watertight VP8 multiple-pin connector, eliminates cable twisting. Maximum chemical resistance provided by rugged polyphenylene sulfide body, completely sealed to eliminate sensor leakage. NEW 3/4 and 1 mounting solutions to meet a variety of application installation requirements. Optimum versatility with various mounting options provided by one-piece construction with process threads in two places. Operates in sub-zero temperatures down to -10 C (14 F). 3900 Insertion/Submersion Sensor Features and Applications General purpose ph/orp 3900/3900VP sensor. The double junction reference aids in the sensor s resistance to harsh environments and helps prolong sensor life. The 3900 and 3900VP are provided with a double junction reference, which protects the reference element from poisoning ions such as ammonia, chlorine, cyanides, and sulfides in the process. Both models are made with porous Teflon junction positioned near the ph/ ORP-sensitive membrane. The SMART preamplifier option becomes enabled when used with the 56, 1056, 1057 analyzers and on the 6081P wireless transmitter. The ph-loop capabilities include auto-recognition of the SMART sensor, automatic upload of calibration data and associated time stamp, historical recording of ph diagnostics (slope, offset, reference impedance, glass impedance). This trending data allows technicians to predict frequency of maintenance and estimate sensor life for a particular process condition. Additional SMART features include factory calibration, resetting SMART sensor calibration data, user menus, and manufacturing information. The AccuGlass ph glass formulations exceed industry standards. The AccuGlass ph glass is a result of many years of glass research resulting in a formulation which has been found to increase the life of the sensor. Unlike other ph glasses presently on the market, this glass resists cracking especially at higher temperatures and reduces sodium ion error commonly found in high ph applications. Overall, the AccuGlass formulation enhances the sensor performance to measure ph more accurately and have a longer sensor life than ever before.

General Purpose ph/orp Sensors September 2013 Features and Applications (cont.) The 3900VP is offered with a watertight sensor-to-cable connector which eliminates re-wiring and cable twisting when replacing sensors. The Variopol VP multiple pin connector is an integral part of each sensor model and uses a mating VP cable. Once the cable is installed and wired to the analyzer, sensors are easily replaced without replacing the cable and without rewiring the analyzer. Also the cable can be disconnected from the sensor before removal from the process which eliminates cable twisting. The 3900 and 3900VP are housed in a molded PPS body, making each sensor virtually indestructible and chemically resistant. Complete encapsulation eliminates leakage or high humidity problems traditionally found in other ph/orp designs. The simplified construction, designed with user convenience in mind does not require electrolyte (KCl) replenishment or any high maintenance troubleshooting procedures. Installation is easily achieved through the wide variety of mounting configurations. Both models feature 1 and ¾ inch (MNPT) front facing connections for insertion, submersion, or flow-through ph and ORP applications. Both models are combination sensors (ph, reference, and temperature within sensor body) and measure ph or ORP (Oxidation/Reduction Potential) of aqueous solutions in pipelines, open tanks, or ponds. The 3900 and 3900VP are suitable for virtually all applications and are compatible with Rosemount Analytical and other manufacturers instruments. Physical Performance and Specifications Sensor Type: General purpose 3900 Measured Range: ph: AccuGlass 0-14 ORP: -1500 to +1500 mv Percent Linearity Over ph Range: Range Operating Temperature: -10 to 100 C (14 to 212 F) Automatic temperature compensation -10 to 100 C (14 to 212 F) Maximum Pressure: 790 kpa [abs] (100 psig) at 100 C (212 F) CRN rating: 60 psig up to 100 C (212 F). Materials of Construction: stainless steel, glass, Teflon, polyphenylene sulfide (PPS), EPDM and silicone Materials of ORP: Platinum Process Connections: Front facing: 3/4 and 1 MNPT Rear facing: 1 MNPT Integral Cable: 32 ft (10m) cable with integral preamp; 15 ft (4.7m) cable without preamp sensor VP8 Cable: use 24281-XX, 2.5 ft (.8m) to 100 ft (31m) Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb) Hazardous Location Approvals: Linearity 0-7 97% 1-7 98% 4-7 98% 7-10 99% 7-12 97% 7-13 96% 7-14 95% 2 RosemountAnalytical.com

September 2013 General Purpose ph/orp Sensors Dimensional drawing for the 3900 and 3900VP 3900 3900VP RosemountAnalytical.com 3

General Purpose ph/orp Sensors September 2013 Installations and Accessories Specifications Typical Flow Through insertion installation using PN 2002011 Pipe Tee (sensor must be installed at least 10 above the horizon) Horizontal Pipe Tee (PN 2002011) Pressure/Temperature Ratings psig (kpa [abs]) F ( C) 150 (1136) 150 (65) 128 (984) 160 (71) 102 (805) 170 (77) 80 (653) 180 (82) 57 (494) 200 (93) 48 (432) 210 (99) Low Flow Cell PN 24091-00 Inlet and outlet connections are stainless steel and take 1/4-inch OD tubing. Flow cell is polycarbonate with 1/4-inch FNPT fittings. MILLIMETER INCH WETTED MATERIALS: BODY & NUT - POLYESTER/ POLYCARBONATE FITTINGS - 316 SST SEALS - SILICONE FLOW CELL RATINGS TEMPERATURE: 32-158 F (0-70 C) MAX. PRESSURE: 90 PSIG (721 kpa [abs]) FLOW RATE: 2-5 GPH (7.6-18.9 LPH) Flow-through tee (2 inch) (PN 915240-03, -04, -05) The following Flow-through Tee s are available for the 3900: 915240-03 915240-04 915240-05. For a new installation use the appropriate tee (915240-xx) and add the S10283-LQD adapter. When replacing an existing 399 with a 3900 sensor, add the S10283-LQD adapter to convert the tee to accept the 3900 sensor. MILLIMETER INCH Adapter 4 RosemountAnalytical.com

September 2013 General Purpose ph/orp Sensors Jet Spray Cleaner PN 12707-00 The Jet Spray Cleaner eliminates routine, manual sensor maintenance by cleaning the sensor with water or compressed air. Flow through the cleaner can be controlled by a solenoid valve. Jet Spray Cleaner shown with 3900VP ph sensor NOTE: The Jet Spray Cleaner can be used with Handrail Mounting Assembly (PN 11275-01, not shown) or can be mounted through conduit as shown above. Low Flow Panel PN SQP10077-LQD Low Flow Panel Specifications Inlet flow Inlet pressure Temperature 3-80 gph (11.4-304 L/hr) 3 65 psig (122 549 kpa abs)* 32-122 F (0-50 C) *The minimum inlet pressure is required to open a check valve, which prevents the flow cell from draining if sample flow is lost. Removing the check valve lowers the inlet pressure requirement to a few feet of water head. RosemountAnalytical.com 5

General Purpose ph/orp Sensors September 2013 3900/3900VP ph/orp Sensor The 3900/3900VP ph/orp Sensor is housed in a PSS plastic body with built-in solution ground for advanced diagnostics. A Pt-100 RTD is offered for temperature compensator. The sensor is available with an integral cable or VP8 connector. Integral preamplifier (-01) is the standard SMART preamplifier option, and is compatible with the XMT, 56, 5081, 6081, 54e and 1056 analyzers/transmitters. Junction box kits with preamplifiers can be ordered separately if an analyzer/ transmitter with an integral preamplifier is not located within 15 ft. of the sensor. 3900 ph/orp Sensor - New Generation general purpose sensor CODE Preamplifier Option 01 SMART Preamplifier, 32 cable 02 No preamplifier, 15 cable CODE Measuring Electrode 10 General Purpose Low resistivity GPLR ph Glass (0-14pH) 12 Platinum ORP Example 3900-01- 12 3900VP ph/orp Sensor - New Generation general purpose sensor with VP CODE Preamplifier option 01 *SMART Preamplifier 02 No preamplifier CODE Measuring Electrode 10 General Purpose Low resistivity (GPLR) ph Glass (0-14pH) 12 Platinum ORP Example 3900-02- 10 * A mating VP connector cable is required for all first time installations of 3900VP sensors. See accessories listing on next page. 3900VP Insertion/Submersion Sensor with VP connector and mating VP cable 6 RosemountAnalytical.com

September 2013 General Purpose ph/orp Sensors Accessories Other Accessories Part Number VP Connector Cables-Use for 1st time Installation of a 3900 VP Sensor 24281-00 15 ft. cable with mating VP8 connector 24281-01 25 ft. cable with mating VP8 connector 24281-02 2.5 ft. cable with mating VP8 connector 24281-03 50 ft. cable with mating VP8 connector 24281-04 100 ft. cable with mating VP8 connector 24281-05 4 ft. cable with mating VP8 connector 24281-06 10 ft. cable with mating VP8 connector 24281-07 20 ft. cable with mating VP8 connector 24281-08 30 ft. cable with mating VP8 connector Mounting Accessories 12707-00 Jet Spray Cleaner 23242-02 Insertion adapter 24091-00 Low flow cell 23555-00 Junction Box with Preamplifier for the 54e, 3081, 4081, 5081, XMT, 1055, 1056 2002011 CPVC flow through Tee, 1-1/2 in. NPT process connection 11275-01 Sensor handrail assembly 9200273 Extension cable, gray 9200348 Extension cable, blue 915240-03 PVC flow through Tee, 3/4 in. NPT process connection 915240-04 PVC flow through Tee, 1 in. NPT process connection 915240-05 PVC flow through Tee, 1-1/2 in. NPT process connection Calibration Accessories 9210012 Buffer solution, 4.01 ph, 16oz 9210013 Buffer solution, 6.86 ph, 16oz 9210014 Buffer solution, 9.18 ph, 16oz R508-8oz. ORP solution, 460mV ±10 @ 20 C SQP10077-LQD Low Flow Control Panel RosemountAnalytical.com 7

LIQ_PDS_3900 Rev. E September 2013 facebook.com/emersonrosemountanalytical AnalyticExpert.com twitter.com/raihome youtube.com/user/rosemountanalytical 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 RosemountAnalytical.com 2013 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.