Float switch For industrial applications, with temperature output Model RLS-3000

Similar documents
Float switch For horizontal installation, miniature design Model HLS-M

Pressure switch, high adjustability of switch differential

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

Differential pressure switch Model DPS40

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Compact temperature switch Model TCS

Electronic flow switch With display, for liquid media Model FSD-3

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Compact differential pressure switch Models DC, DCC

Insertion thermometer With connection lead Model TF45

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Compact pressure switch Model PCS

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Mini pressure switch Stainless steel switch enclosure Model PXS

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Duct thermometer Model TF40

Resistance thermometer with digital display Model TR75, battery operation

Diaphragm seal with threaded connection Plastic version Model

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Reed sensor For bypass level indicators Model BLR

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Magnetic float switch For vertical installation Model FLS

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Mechatronic pressure measurement. Applications. Special features. Description

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Diaphragm seal with sterile connection For homogeniser machines Model

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Bimetal thermometer Model 52, industrial series

Measuring insert for process resistance thermometer

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Mini temperature switch Stainless steel switch enclosure Model TXS

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Surface thermocouple Model TC50

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

Differential pressure gauge Model , copper alloy Model , stainless steel version

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Measuring probe For ventilation and air-conditioning Model A2G-FM

Thermowell For sanitary applications Model TW61, for orbital welding

Diaphragm seal with flange connection For the pulp and paper industry Model

Resistance thermometer with digital indicator Model TR75, battery operation

Bimetal thermometer Model 52, industrial series

Screw-in thermometer with connection lead Model TF37

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

Thermowell For sanitary applications Model TW61, for orbital welding

Machine glass thermometers Model 32, V-Form

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Differential pressure gauge with electrical output signal Model A2G-15

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Model TR10-B, for additional thermowell

Temperature multi-function calibrator Model CTM

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Cable resistance thermometer Model TR40

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Magnetic switch For bypass level indicators Model BGU

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Thermowell For sanitary applications Model TW22

Resistance thermometer Model TR10-E, for additional thermowell

Cable resistance thermometer Model TR40

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Cable resistance thermometer Model TR40

Thermowell For sanitary applications Model TW61, for orbital welding

Gas-actuated thermometer Model 73, stainless steel version

Tubeskin thermocouple assembly Model TC59-W

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Thermowell For sanitary applications Model TW61, for orbital welding

Pressure Transmitters for Sanitary Applications Model SA-11

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Tubeskin thermocouple assembly Model TC59-V

Transcription:

Level measurement Float switch For industrial applications, with temperature output Model RLS3000 WIKA data sheet LM 50.06 Applications Combined level and temperature measurement of liquids in machine building Control and monitoring tasks for hydraulic power packs, compressors and in cooling systems Special features Media compatibility: Oil, water, diesel, refrigerants and other liquids Level: Up to 3 switching outputs, freely definable as normally open, normally closed or changeover contact Temperature: 1 bimetal temperature switch or, accuracy: Class B Potentialfree switching reed contacts Description Fig. left: With cable outlet and spherical float Fig. right: With circular connector M12 x 1 and cylindrical float The model RLS3000 float switch with temperature output combines the recording of the level and temperature of liquids in a single measuring point. The stainless steel used is suitable for a multitude of media, such as, for example, oil, water, diesel and refrigerants. Measuring principle A permanent magnet built into the float triggers, with its magnetic field, the potentialfree reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contactfree and thus free from wear. Depending on customer wishes, the switching functions of normally open, normally closed or changeover can be realised for the defined liquid level. The additional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a resistance signal. Page 1 of 7 Data sheets showing similar products: Float switch; model RLS1000; see data sheet LM 50.03 Float switch, plastic version; model RLS2000; see data sheet LM 50.04 Float switch, intrinsic safety Ex i; model RLS4000; see data sheet LM 50.07

Specifications Float switch, model RLS3000 Measuring principle Measuring range Output signal Switching function Switch position Distance between switch points 2) Switching power Level Potentialfree switching reed contacts are triggered by a magnet in the float Guide tube length L: 60... 1,500 mm (2.5... 59 in), other lengths on request Up to 3 switch points, depending on the electrical connection: LSP1, LSP2 1), LSP3 1) Alternatively normally open (NO), normally closed (NC) or changeover (SPDT) contact 1) on rising level Temperature Bimetal switch or measuring resistor in pipe end Bimetal switch: 30... 150 C (86... 302 F) Bimetal switch Pt100, 2wire Pt1000, 2wire Specified in mm, starting from the upper sealing face (LSP1... LSP3) At the end of the guide tube 45 mm ( 1.8 in) cannot be used for switch positions. Alternatively normally open (NO) or normally closed (NC) Minimum distance LSP1 to the upper sealing face: 50 mm (2.0 in) Minimum distance between the switch points: 50 mm (2.0 in), for floats with outer diameter D = 44 mm (1.7 in), 52 mm (2.0 in) 30 mm (1.2 in), for floats with outer diameter D = 25 mm (1.0 in), 30 mm (1.2 in) Minimum distance with 3 switch points: 80 mm (3.1 in), either between LSP1 and LSP2 or LSP2 and LSP3 Floats with outer D = 44 mm (1.7 in), 52 mm (2.0 in) Normally open, normally closed: AC 230 V; 100 VA; 1 A DC 230 V; 50 W; 0.5 A Changeover contact: AC 230 V; 40 VA; 1 A DC 230 V; 20 W; 0.5 A Floats with outer D = 25 mm (1.0 in), 30 mm (1.2 in) Normally open, normally closed: AC 100 V; 10 VA; 0.5 A DC 100 V; 10 W; 0.5 A Changeover contact: AC 100 V; 5 VA; 0.25 A DC 100 V; 5 W; 0.25 A Normally open, normally closed: AC 250 V; 2 A ( 50 ma) DC 60 V; 1 A ( 50 ma) Accuracy ±3 mm switch point accuracy incl. hysteresis, nonrepeatability Bimetal switch: ±5 C switch point accuracy, ±20 C hysteresis Pt100, Pt1000: Class B per DIN EN 60751 Mounting position Vertical ±30 Process connection Material Wetted Nonwetted Permissible temperatures Medium Ambient Storage G 1, installation from outside G 1 ½, installation from outside G 2, installation from outside Flange DN 50, form B per EN 10921 (DIN 2527), PN 16, installation from outside Process connection, guide tube: Stainless steel 1.4571 (316Ti) Float: See table on page 3 Case: Stainless steel 1.4571 (316Ti) Electrical connection: See table on page 3 30 +80 C (22 +176 F) 30 +120 C (22 +248 F) 4) 30 +150 C (22 +302 F) 5) 30 +80 C (22 +176 F) 30 +80 C (22 +176 F) G ⅛, installation from inside 3) G ¼, installation from inside 3) G ⅜, installation from inside 3) G ½, installation from inside 3) 1) For medium temperatures > 80 C (> 176 F) switch points only with float outer diameter D = 44 or 52 mm 2) Smaller minimum distances on request 3) Only for versions with cable outlet 4) Not with cable material: PVC, PUR; not with float outer diameter D = 25; not with connection housing 58 x 64 x 36 mm 5) Only with cable material: Silicone or connection housing 75 x 80 x 57 mm; not with float outer diameter D = 25 mm Page 2 of 7

Electrical connections 1) Circular connector M12 x 1 (4pin) Cable outlet Cable outlet Cable outlet Connection housing standard Dimensions: 75 x 80 x 57 mm (3.0 x 3.1 x 2.2 in) For cable diameter: 5... 10 mm (0.2... 0.4 in) Connection housing compact Dimensions: 58 x 64 x 36 mm (2.3 x 2.5 x 1.4 in) For cable diameter: 5... 10 mm (0.2... 0.4 in) Level Max. switch point definition Ingress protection per IEC/EN 60529 2) Protection class Material Cable length 1 NO/NC IP65 SK II TPU, brass 3 SPDT 3 SPDT 1 NO/NC + 1 SPDT 3 SPDT 1 NO/NC + 1 SPDT IP67 SK II PVC 2 m (6.5 ft) 5 m (16.4 ft) IP67 SK II PUR other lengths on request IP67 SK II Silicone IP66 SK I Aluminium, glands from polyamide, brass, stainless steel IP66 SK I Float Form Outer diameter D Height H Operating pressure Medium temperature Density Material Cylinder 3) 6) 44 mm (1.7 in) 52 mm (2.0 in) 16 bar ( 232 psi) 150 C ( 302 F) 750 kg/m³ (46.8 lbs/ft³) 316Ti H Cylinder 4) 30 mm (1.2 in) 36 mm (1.4 in) 10 bar ( 145 psi) 150 C ( 302 F) 850 kg/m³ (53.1 lbs/ft³) 316Ti D Cylinder 4) 25 mm (1.0 in) 17 mm (0.7 in) 16 bar ( 232 psi) 80 C ( 176 F) 750 kg/m³ (46.8 lbs/ft³) Buna / NBR Sphere 5) 6) 52 mm (2.0 in) 52 mm (2.0 in) 40 bar ( 580 psi) 150 C ( 302 F) 750 kg/m³ (46.8 lbs/ft³) 316Ti H D 1) Versions with protective conductor on request 2) The stated ingress protection (per IEC/EN 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection. 3) Not with process connection G 1, guide tube length L 100 mm (L 3.94 in) 4) Guide tube length L 1,000 mm (L 39.37 in), switch points for level max. 2 NO/NC or 1 SPDT definable 5) Not with process connection G 1, G 1 ½, guide tube length L 100 mm (L 3.94 in) 6) Not with process connection G ⅛ Connection diagram Circular connector M12 x 1 (4pin) Level Temperature Normally open/normally closed (NO/NC) Bimetal switch Platinum measuring resistor LSP1 TSP Platinum measuring resistor 1 2 3 4 3 4 + Page 3 of 7

Cable outlet 1) Level Temperature Normally open/normally closed (NO/NC) Bimetal switch Platinum measuring resistor 3 switch points LSP1 GN YE LSP2 GY PK LSP3 BU RD TSP + Changeover contact (SPDT) Bimetal switch Platinum measuring resistor 3 switch points LSP1 YE GY LSP2 BU RD LSP3 VT GYPK TSP + PK BK RDBU Aluminium case Standard Level Temperature Normally open/normally closed (NO/NC) Bimetal switch Platinum measuring resistor 3 switch points LSP1 LSP2 LSP3 W7 TSP1 0 0 + W2 W8 Changeover contact (SPDT) Bimetal switch Platinum measuring resistor 2 switch points LSP1 LSP2 LSP3 W7 TSP1 0 0 + W2 W8 W3 W6 W9 Compact 2) Normally open/normally closed (NO/NC) Bimetal switch Platinum measuring resistor 1 switch point LSP1 TSP1 + W2 Changeover contact (SPDT) Bimetal switch Platinum measuring resistor 1 switch point LSP1 TSP1 + W2 W3 1) For combinations of different switching output functions the PIN assignment is marked on the product label. 2) In variants with 2 or 3 switching outputs for level, the deviating pin assignment is noted on the product label Legend SP1 SP3 s GY Grey BK Black White PK Pink VT Violet Brown BU Blue GYPK Grey/Pink GN Green RD Red RDBU Red/Blue YE Yellow Page 4 of 7

Electrical safety Insulation voltage DC 2,120 V Dimensions in mm (in) with circular connector M12 x 1 with cable outlet with connection housing Compact Standard Legend L Guide tube length T Nonusable range for switch positions Page 5 of 7

Process connection Installation from outside Installation from inside G L 1 G 1 16 mm (0.63 in) G 1 ½ 18 mm (0.71 in) G 2 20 mm (0.79 in) G L 1 G ⅛ B 12 mm (0.47 in) G ¼ B 12 mm (0.47 in) G ⅜ B 12 mm (0.47 in) G ½ B 14 mm (0.55 in) Flange DN 50, form B per EN 10921 (DIN 2527), PN 16 Accessories Circular connector M12 x 1 with moulded cable Description Temperature range Cable diameter Cable length Order no. Straight version, cut to length, 4pin, PUR cable, UL listed, IP67 20... +80 C (4... +176 F) 4.5 mm (0.18 in) 2 m (6.6 ft) 14086880 5 m (16.4 ft) 14086883 10 m (32.8 ft) 14086884 Angled version, cut to length, 4pin, PUR cable, UL listed, IP67 20... +80 C (4... +176 F) 4.5 mm (0.18 in) 2 m (6.6 ft) 14086889 5 m (16.4 ft) 14086891 10 m (32.8 ft) 14086892 Page 6 of 7

Approvals Logo Description Country EU declaration of conformity Low voltage directive RoHS directive European Union Manufacturer s information and certificates Logo Description China RoHS directive Approvals and certificates, see website Ordering information Model / Level and temperature output signals / Switching function / Electrical connection / Process connection / Guide tube length L / Medium temperature 11/2017 EN 01/2017 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 7 of 7 WIKA Alexander Wiegand SE & Co. KG AlexanderWiegandStraße 30 63911 Klingenberg/Germany Tel. +49 9372 1320 Fax +49 9372 132406 info@wika.de www.wika.de