MANUFACTURED IN THE UK

Similar documents
Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MANUFACTURED IN THE UK

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

LED Emergency Luminaires

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

LED emergency exit signage from Channel Safety Systems

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

UL AND CODE COMPLIANCE

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Norwich Hostry Norwich, UK. Downlight Lighting

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

Emergency lighting units EM series

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Industrial Linergy LED

RUBIX RECESSED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

6 Linergy LED+ Industrial IP20 CONTROLS

LED.Commercial 12W LED DD

Zone 1 Linear Range - Installation Guide

Specification Sheet for 2D LED Light

Installation and Operation Instructions 10/04/13

5 Linergy LED. Industrial. Mains lighting IP20

5 Linergy LED. Industrial. Mains lighting IP20

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Central Battery Systems Loadstar AC/DC Systems

DTFA Elite. Optics. IP65/54 recessed luminaire with sealed twin frame construction. Prismatic Diffuser. Cam Jacking Bracket

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

High Efficiency Lighting units

Emergency lighting units EM powerled

Lighting for: Community Housing

Emergency lighting units EM powerled

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

GDS-133-REV1 08th November 2012 FIE. Making Perfect Sense

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Emergency lighting units EM converterled

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

TRACER LED LOWBAY 2 INTRODUCTION APPLICATION PRODUCT SPECIFICATION

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

Operating Instructions

Emergency lighting units EM powerled

Emergency lighting units EM LED Light Engines

RUNWAY SURFACE/SUSPENDED

Operating Instructions

RXD. 194 Downlights & Spotlights

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

COMTEC LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

Emergency lighting units EM converterled

Emergency lighting units EM INVERTER

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

INSTALLATION & MAINTENANCE MANUAL HBL

Emergency lighting units EM converterled

Model: CF16MS / CF16CR / CF16WH CF28MS / CF28CR / CF28WH

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM powerled

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency lighting units EM powerled

Project F J Need (Foods) Ltd - Nantwich. Stormloc LED p363

light J ANATOMY or CLEAN CANTILEVER Sleek square aluminum tube cantilever arms allow integral powerfeed to an electrical junction box.

This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements.

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Quality LED Lighting. LED Bulkheads Recessed Ceiling Luminaires Emergency Lighting. Edition

A-BEAM LIGHT. Instruction & Safety Information. Design by Thomas Housden. Dimensions L1600/1800mm H77mm, W51mm. Weight 9-10 KG

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

RUNWAY WALL INTRODUCTION APPLICATION

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Emergency lighting units EM converterled

Tempo compact and consistent

DALI Emergency LED Driver - 350/700/1000mA Constant Current

Existalite ZV 4-pole self-contained emergency lighting conversion module

TANEK INTRODUCTION APPLICATION PRODUCT SPECIFICATION

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Installation & User Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

LED OYSTER & PENDANT LIGHTS

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

RIM 72" RIM 24" File Name: RIM-ROUND-PENDANT-SPEC Page: 1 / 9

PROTECTA III. Construction Tough glass reinforced polyester body

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

FULL BLEED APPLICATION SHOT RENDERING

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Emergency lighting units EM Inverter

Installation Instruction

Transcription:

The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of decorative finishes to suit every application. Utilising a common gear tray, each body size can accomodate up to fifteen lamp and gear options, which when coupled with seven body choices give over a hundred variations available! With the 425mm body also achieving a white or coloured backlit halo effect, the Galileo II range is a specifiers dream. G GE Lighting 2D lamps are fitted as standard. VERSIONS 425mm diameter spun steel bodies Choice of finishes: Electroplated Chrome Powder Coated White Polycarbonate Opal Diffuser 16W, 28W, 38W GE 2D lamp High Frequency Electronic Control Gear Hinged Gear Tray 3 Hour Maintained Emergency & Auto test Emergency (38W in 425mm only) Microwave Presence Detector Dimmable (38W only) DALI (28W & 38W only) I20 A C MANUFACTURED IN THE UK Fittings are manufactured and tested in accordance with BS EN 60598. They are also RoHS compliant. page 1 of 13

page 2 of 13

SPRING CLIP POLYCARBONATE DIFFUSER OPTIONAL COLOURED BACKLIGHT INSERTS HINGED GEAR TRAY GE 2D LAMP ALL APPROVED COMPONENTS GEAR TRAY RELEASE SCREW STEEL BODY page 3 of 13

INSTALLATION AND OPERATING INSTRUCTIONS THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition of the IEE Electrical Regulations. Information regarding Part Number, Description, Voltage, Frequency, IP Rating and Lamp type is shown on the label affixed to the box containing the luminaire. Pre-installation ALWAYS TURN OFF THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION Make sure that the mains supply is compatible with the fitting. If IP rating has to be retained a cable gland of the correct IP rating must be used and any fixing holes must be filled with a proprietary silicon sealing compound. High voltage insulation test equipment MUST NOT be used on High Frequency, Emergency or Dimming luminaires. The luminaire is suitable for use within ambient temperature range of -10º C to +25º C ONLY. PIR and electronic time switches are not recommended for these luminaries. If used, ensure that there is no Leakage Current when in the Off position and an On time of not less than 20 minutes. Failure to ensure this could potentially impair the performance of the luminaire. Lamp Switching Cycles / Lamp Life CONSTANT SWITCHING REDUCES LAMP LIFE Typical switching cycles should achieve 100% of the manufacturers stated lamp life, however, switching every 5 minutes would reduce this to 20%. Installation Take out the base moulding. Drill out the cable entry and any other Cut Outs required. If cut outs are required for conduit fixing (Not BESA) make sure that the hole is drilled high enough in the side of the base to allow the inside nut to be fitted. Feed the incoming mains through the cable entry gland and secure the base to the mounting surface required using the mounting points provided (failure to do this will cause the fitting to distort) with fixings suitable to support the fitting and for the material to which the base is being attached Put the gear tray into the Hinge position, tighten the two screws and allow the Gear tray to hinge open. Make sure that the incoming mains cable is long enough to allow the Gear Tray to be completely opened. Connect the incoming mains to the terminal block. If using stranded cables, make sure that no stray wires are omitted from the terminal connection. page 4 of 13

Flying lead or Direct Wiring Standard TB Wiring Incoming Supply Neutral Blue or Black Earth Line Brown or Red N L Blue Gn / Y Brown White Gn / Y White Luminaire Wiring Emergency TB Wiring Incoming Supply Neutral Earth Un-switched Line Switched Line Blue or Black Brown or Red Yellow N 1 2 Blue Gn / Y Brown White Luminaire Wiring Close the Gear Tray (make sure that all cables are clear of the Gear Tray components) and secure with the screw provided. Fit the lamp making sure that it is securely clipped in. Screw on the diffuser making sure that it is correctly tightened to locate in the seal. ADDITIONAL NOTES FOR EMERGENCY LUMINAIRES THIS PRODUCT IS APPROVED FOR SURFACE MOUNTING ONLY These instructions are for non-maintained, maintained and sustained emergency light fittings, which incorporate a fluorescent lamp(s). The ballast is electronic, consisting of a high frequency inverter, battery charger, charge indicator, and battery deep discharge protection circuit. These fittings are self-contained without Rest Mode facility. All emergency versions are 3 hour duration. The Mains supply and the Battery connection must be disconnected before servicing or maintenance. VERY IMPORTANT To make the fitting Non Maintained leave out the Switched Line The battery connections must be left disconnected during installation if the site supply is switched off at the end of the day. Failure to do this will damage the fitting. page 5 of 13

Circuits The emergency mains supply must be connected to a direct source via a Key Switch (for test purposes only). The switched line must be wired so that it disconnects from the luminaire if the Key Switch is switched off (no power to the fitting). NOTE: The incoming supply earth MUST be connected. NOTE: - Both luminaire supplies must be broken simultaneously (switched and unswitched) when testing. Connections into the ballast must not exceed 2.5mm 2. After connecting the mains supply, check that the charge indicator lamp (LED) is illuminated. The fluorescent lamp should operate when the luminaire is switched on (maintained and sustained only). An initial uninterrupted minimum charge period of 36 hours should always be allowed before testing the module for its rated duration. The recommended maximum battery storage period of one year should not be exceeded. If batteries have been left in a discharged state, one or more full charge / discharge cycles may be necessary to restore them to their normal capacity. Stick the supplied rating label to the luminaire where it can be seen. i.e. On the base, if surface mounted. On the gear tray, if not practical to stick on the base. MUST not be fitted on the diffuser. page 6 of 13

Routine maintenance Routine maintenance must be carried out in compliance with the requirements of the British Standards Institute Code of Practice BS5266: Part 1 - Emergency Lighting of Premises. The following tests assume a three-hour system Daily: Monthly: 1 Check that any recorded faults have been rectified. 2 Check that the emergency lamp is operative. 3 Check that the charge indicator light is illuminated. 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for three minutes. 2 After reverting back to mains supply check the charge indicator light is illuminated. Six monthly: Three years: 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least one hour. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 24 hours to recharge before becoming fully operational. 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least 3 hours. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 36 hours to recharge before becoming fully operational. It is recommended that battery packs and lamps are replaced every 4 years or sooner if the unit performance requirements fail to be met. To maintain optimum unit performance, only approved replacement battery packs and lamps must be used. All routine maintenance checks must be recorded on the unit Test Record / Installation sheet and must be made available for inspection at all times. INSTALLATION / COMMISSIONING AND TEST RECORD Routine Test Record Model No Type Installed By Commissioned By Location SAMPLE Serial No (on gear tray) First Year Second Year Third Year Fourth Year Fifth Year Monthly Test Signed Date Signed Date Signed Date Signed Date Signed Date 1 Hour Duration 1 Hour Duration Full Duration Date Date page 7 of 13

GENERAL ROUTINE MAINTENANCE At commissioning and handing over of the installation, ensure that a copy of this data is presented to the authority responsible for the operation, maintenance and repair of Luminaires. Cleaning of the Luminaire or lamp replacement must only be carried out after the fitting has been isolated from the electrical supply. ALWAYS check before servicing. Cleaning should be carried out at regular intervals to ensure that contaminants do not accumulate to an extent that will impair the thermal safety of the Luminaire, or degrade the optical performance of the lamp. DO NOT use Spirit based cleaners. Failed lamps must be replaced immediately, with Lamps of the same type, if a Starter Switch is fitted, this should be changed at the same time. Undetected or unattended failed lamp replacement will result in the Ballast unit overheating and ultimately will cause its failure, rendering the fitting useless. Notes: This luminaire should not be modified or repaired by any persons other than those nominated by the manufacturer. Any unauthorised modification or repair may render the luminaire unsafe and will invalidate the warranty and conformance to any safety or safety standards that may apply. The company will accept no responsibility for any modified fittings or for any damage caused as a result of modifications. All details are given as guidance only and do not constitute a contract. We reserve the right to change or withdraw products without notice. Performance and Warranty This product is warranted for twelve months from the date of installation, provided that the installation is carried out within two months of purchase, subject to the following conditions. This warranty will only be valid if the fittings have remained unmodified and used as per this instruction leaflet and our literature. Fern - Howard Ltd. shall not be liable for any consequential loss or damage caused directly or indirectly by any defective or otherwise. Battery packs are guaranteed for 12 months but are expected to have a life of at least four years if used within the specified temperature limits. Disposal The disposal of any electrical equipment, including this fitting may be subject to Local Authority Regulations and therefore should be consulted for specific guidance. The batteries within this fitting are Nickel Cadmium and must be disposed of as per Local Authority Regulations for the disposal of toxic waste. page 8 of 13

2 PIN LAMP SWITCH START 4 PIN LAMP SWITCH START DIMMING HIGH FREQUENCY page 9 of 13

EMERGENCY MAINTAINED EMERGENCY DIMMING EMERGENCY MAINTAINED DALI EMERGENCY MAINTAINED AUTO TEST page 10 of 13

Lamp Lumen Output (Mains- Mode) Approx Lamp Life (Hrs) Nominal Lamp Current A MAGNETIC HF EM Parallel Correction Capacitor Corrected Lamp Current A Circuit Watts Corrected HF Current A Circuit Watts BLF HF BLF Emergency Normal BLF Emergency EM Mode 16W 1050 10,000 0.195 2uf 0.09 27.83 0.121 18.0 0.960 0.950 0.180 28W 2250 15,000 0.320 4uf 0.15 34.5 0.130 28.7 0.960 0.750 0.120 38W 3000 15,000 0.430 4uf 0.200 46.0 0.180 39.7 0.960 0.950 0.065 Lamp Weight Weight HF Weight EM 16W 2.6 2.25 2.8 28W 2.84 2.31 3.09 38W 3.17 2.46 3.24 Lumen Output In Emergency Mode Lamp Mains EM 1Hr EM 2Hr EM 3Hr 16W 1050 146 143 134 28W 2250 196 196 171 38W 3000 190 186 154 150 o 180 o 150 o Size 425mm Dia x 115 Deep Cable Entry Centre Rear BS Style Body Material Painted or Plated Steel 120 o 120 o Diffuser Material Polycarbonate Gear Tray Material Polycarbonate Lamp GE 2D 3500K Wiring TB 2 x 2.5mm 2 90 o 90 o Diffuser Fixing Spring Located 20 Control Voltage 240V 50Hz 60 o 30 o C0 / C180 40 60 60 o 80 100 0 o 30 o cd / 1000 im C90 / C270 LOR = 0.43 SHR MAX = 1.48 SHR NOM = 1.25 Room Reflectances Room Index C W F 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0.20 0.22 0.26 0.29 0.31 0.34 0.36 0.37 0.39 0.40 0.30 0.18 0.22 0.25 0.28 0.31 0.33 0.35 0.37 0.39 0.10 0.16 0.20 0.23 0.25 0.29 0.31 0.33 0.36 0.37 0.50 0.50 0.20 0.20 0.24 0.26 0.28 0.31 0.33 0.34 0.36 0.37 0.30 0.17 0.21 0.24 0.26 0.29 0.31 0.32 0.34 0.36 0.10 0.15 0.19 0.22 0.24 0.27 0.29 0.31 0.33 0.35 0.30 0.50 0.20 0.19 0.22 0.24 0.26 0.29 0.30 0.31 0.33 0.34 0.30 0.16 0.20 0.22 0.24 0.27 0.29 0.30 0.32 0.33 0.10 0.14 0.18 0.21 0.23 0.25 0.27 0.29 0.31 0.32 0.00 0.00 0.00 0.13 0.16 0.18 0.20 0.22 0.24 0.25 0.27 0.28 FIGURES BASED ON 38W CORRECTED SWITCHSTART FITTING page 11 of 13

High Frequency FHE430-16-BR FHE430-16-CH FHE430-16-SC FHE430-16-W FHE430-28-BR FHE430-28-CH FHE430-28-SC FHE430-28-W FHE430-38-BR FHE430-38-CH FHE430-38-SC FHE430-38-W GALILEO II 430 16W BRASS HF GALILEO II 430 16W CHROME HF GALILEO II 430 16W SATIN CHROME HF GALILEO II 430 16W WHITE HF GALILEO II 430 28W BRASS HF GALILEO II 430 28W CHROME HF GALILEO II 430 28W SATIN CHROME HF GALILEO II 430 28W WHITE HF GALILEO II 430 38W BRASS HF GALILEO II 430 38W CHROME HF GALILEO II 430 38W SATIN CHROME HF GALILEO II 430 38W WHITE HF Emergency Maintained FHE430-16-BR-EM FHE430-16-CH-EM FHE430-16-SC-EM FHE430-16-W-EM FHE430-28-BR-EM FHE430-28-CH-EM FHE430-28-SC-EM FHE430-28-W-EM FHE430-38-BR-EM FHE430-38-CH-EM FHE430-38-SC-EM FHE430-38-W-EM Auto Test FHE430-28-BR-AT FHE430-28-CH-AT FHE430-28-SC-AT FHE430-28-W-AT FHE430-38-BR-AT FHE430-38-CH-AT FHE430-38-SC-AT FHE430-38-W-AT Dimmable FHE430-38-BR-DIM FHE430-38-CH-DIM FHE430-38-SC-DIM FHE430-38-W-DIM DALI Emergency FHE430-28-BR-DAEM FHE430-28-CH-DAEM FHE430-28-SC-DAEM FHE430-28-W-DAEM FHE430-38-BR-DAEM FHE430-38-CH-DAEM FHE430-38-SC-DAEM FHE430-38-W-DAEM GALILEO II 430 16W BRASS EM GALILEO II 430 16W CHROME EM GALILEO II 430 16W SATIN CHROME EM GALILEO II 430 16W WHITE EM GALILEO II 430 28W BRASS EM GALILEO II 430 28W CHROME EM GALILEO II 430 28W SATIN CHROME EM GALILEO II 430 28W WHITE EM GALILEO II 430 38W BRASS EM GALILEO II 430 38W CHROME EM GALILEO II 430 38W SATIN CHROME EM GALILEO II 430 38W WHITE EM GALILEO II 430 28W BRASS AUTO TEST GALILEO II 430 28W CHROME AUTO TEST GALILEO II 430 28W SATIN CHROME AUTO TEST GALILEO II 430 28W WHITE AUTO TEST GALILEO II 430 38W BRASS AUTO TEST GALILEO II 430 38W CHROME AUTO TEST GALILEO II 430 38W SATIN CHROME AUTO TEST GALILEO II 430 38W WHITE AUTO TEST GALILEO II 430 38W BRASS DIMMABLE GALILEO II 430 38W CHROME DIMMABLE GALILEO II 430 38W SATIN CHROME DIMMABLE GALILEO II 430 38W WHITE DIMMABLE GALILEO II 430 28W BRASS DALI EM GALILEO II 430 28W CHROME DALI EM GALILEO II 430 28W SATIN CHROME DALI EM GALILEO II 430 28W WHITE DALI EM GALILEO II 430 38W BRASS DALI EM GALILEO II 430 38W CHROME DALI EM GALILEO II 430 38W SATIN CHROME DALI EM GALILEO II 430 38W WHITE DALI EM page 12 of 13

Dimmable Emergency FHE430-38-BR-EMD FHE430-38-CH-EMD FHE430-38-SC-EMD FHE430-38-W-EMD GALILEO II 430 38W BRASS DIMMABLE EM GALILEO II 430 38W CHROME DIMMABLE EM GALILEO II 430 38W SATIN CHROME DIMMABLE EM GALILEO II 430 38W WHITE DIMMABLE EM page 13 of 13