Installation Instructions Models LGH-F300, F470, F600RX5-E

Similar documents
The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.

CEILING CONCEALED LOSSNAY LGH-80RX3

CEILING CONCEALED LOSSNAY LGH-50RX3

CEILING CONCEALED LOSSNAY LGH-25RX3

20 C (68 F) 16 C (60.8 F)

Air duct switching damper

/ LOSSNAY / LGH-RS2-E2

VL-100U5-E (pull cord type) VL-100EU5-E (wall switch type)

HEAVY DUTY POWER RELAYS FEATURES

Heat Recovery Ventilation

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

POWER REGULATOR LD -40PSU

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

PANcharge1k Battery Charger User's Manual

SCC-MPPT Solar Charge Controller

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

DC Master 24/ A

SCC-MPPT Solar Charge Controller

Solar Charge Controller

CH5000 Heat Recovery Ventilator

SCC-MPPT Solar Charge Controller

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Product specifications

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

Infinity Burnout Furnaces

HS6B Series Subminiature Interlock Switch

Safety & Installation Instructions

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

ARTICLE BEGINNING SERVICE PRECAUTIONS

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

ENGINE COOLING SYSTEM

SOLAR CHARGE CONTROLLER

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

1.Safe testing IMPORTANT:

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

O W N E R ' S M A N U A L

Hot-Shot Operating Instructions

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

Model 8144NC Fresh Air Ventilator

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Lumitester PD-20 Control Kit

11. Installation Instruction

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 PRECAUTION... 3 PREPARATION... 5 SYSTEM DESCRIPTION...

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

General Precautions. Personnel Precautions

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 SYSTEM DESCRIPTION... 3 PRECAUTION... 6 PREPARATION...

230VAC Power Inverter 400W Owner s Manual

SERVICE MANUAL (2)

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

ION JET NOZZLE NIH-55

Operating Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

SG-B1 SERIES / SG-A1 SERIES

Power Inverter 400 MW Owner s Manual

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

TOWA SEIDEN INDUSTRIAL CO., LTD.

INSTALLATION MANUAL. PRVC2 is available only for the Multi-V IV model (PRVC2 can not be installed for the previous Multi-V IV model)

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Instruction Book for. ContouR ElECtRol

- Wiring Brochure tekmarnet 4 Thermostat 545

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

400 Watt Backup Power System Owner s Manual

INSTRUCTION & INSTALLATION

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Battery Unit BHM60PC/BHM100PC Instruction Manual

Florham Park, NJ USA Call (ASCO) for sales or service

No Operation of air conditioner Explanation

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 FUNCTION DIAGNOSIS... 3 PRECAUTION... 6 PREPARATION...

C3 Operating Instructions

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Measurements are expressed in millimeters.

ATD WATT INVERTER

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

WARNING Risk of property damage, injury, or death.

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

c-go 24V/6A 24V/8A 24V/12A

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Compact System NRGS 11-2 NRGS Original Installation Instructions English

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

Transcription:

0H0 Energy Recovery Ventilator Models: LGH-F300RX-E, LGH-F0RX-E, LGH-F00RX-E, LGH-F00RX-E (For use by dealer/contractor) Installation Instructions Models LGH-F300, F0, F00RX-E Model LGH-F00RX-E ontents Safety precautions... Outline drawings... Standard installation examples...3 Installation method...3 Function settings... 0 Trial operation... heck points after installation work... This product needs to be installed properly in order to ensure maximum functionality as well as safety. Please make sure to read this installation manual before starting the installation. Installation must be performed by a dealer or installation contractor. Please note that improper installation may cause malfunction or accident. Separate booklet Operating Instructions is provided for the customer. The booklet and this manual must be handed over to the customer after completing the installation. English Safety precautions The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below. Do not disassemble Prohibition of use in bath or shower room onnect the grounding wire. Prohibited Do not modify or disassemble. (It could cause fire, electric shock or injury.) The unit and remote controller should not be installed where it is highly humid, like a bathroom, or other wet place. (It could cause electric shock or power leakage.) onnect the product properly to ground. (Malfunctioning or power leaks can cause electrical shock.) Do not place a burning appliance in a place where it is exposed directly to the air from the unit. (It could cause an accident as a result of incomplete combustion.) Do not use at a place where it is exposed to high temperatures (0 F (0 ) or higher), naked flames, or in environment with combustible fumes. (It could cause fire.) Do not use in an environment such as a chemical factory, where hazardous gases such as acidic gases, alkaline gases, organic solvent fumes, paint fumes, or gases containing corrosive components are generated. (It could cause malfunction.) Do not install this product in a place where it is exposed to ultraviolet light. (UV may damage covering insulation.) When using the product where it is exposed to high temperatures and humidity (0 F (0 ) or higher, RH 0% or higher), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit. The product should not be used under such conditions. Outdoor air may enter the owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install an Electrically operated damper to block the outdoor air. In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an electrically operated damper. WARNING The instructions given must be followed. AUTION The instructions given must be followed. AUTION Use the specified power supply and voltage. (Use of incorrect power supply or voltage could cause fire or electric shock.) Select a place with sufficient strength and install the main unit securely. (It could cause injury if it falls.) Wiring work must be performed by qualified professionals, and be implemented safely and securely in accordance with the engineering standards and the extension wiring rules for electrical equipment. (Poor connection or improper wiring work could cause electric shock or fire.) Install a power supply isolator at the power supply side as per local electrical regulations. All supply circuits must be disconnected before obtaining access to the terminal devices. Use the specified cable size and connect the cables securely to prevent disconnection when they are pulled. (If there is a defect in the connection, there is a possibility of fire.) Select an adequate place for the opening to introduce outdoor air, where it will not intake the exhaust fumes like combustion gas, or others, and there is no risk of blockage. (Shortage of fresh air could put the room in a state of oxygen deficiency.) A duct made of steel must be installed with care not to be connected electrically with metals such as metal, wire, stainless steel plate, or others. (It could cause fire when power leakage occurs.) Put on gloves during installation. (It could cause injury.) Make sure the power supply isolator is turned off on the power distribution panel when is not used for a long period of time after the installation. (It could cause electric shock, power leakage, or fire as a result of deteriorated insulation.) Always use the specified suspension bolts, nuts and washers and correctly rated wire / chain hangers. (Use of hardware with insufficient strength could result in the product dropping.) The outside ducts must be tilted at a gradient (/30 or more) down toward the outdoor louvres from, and properly insulated. (The entry of rain water may cause power leakage, fire, or damage to household property.) The control box cover must be closed after the installation. (Dust or humidity may cause power leakage or fire.) When connecting external devices (electrically operated damper, lamp, monitoring unit, etc.) using output signals of the unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment.) When using the product in an environment where there is a window, or opening near the outdoor louvre, where insects are likely to gather around the interior or exterior light, take note that small insects may intrude into the product. In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to confirm the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. *Example of dewing condition - Outdoor air: 3 F (- ) or lower, dew-point temperature at installation place: 0 F (0 ) or higher (When the indoor temperature is. F ( ) or higher with the relative humidity higher than 0%, or other)

Outline drawings LGH-F300, F0, F00 RX EA (exhaust air outlet) Position where duct direction change is possible *LGH-F0 and F00RX types Bypass damper plate (-/ X 3/ (- X 0) oval) M Air exhaust fan eiling suspension fixture D (-/ X 3/ F (-3 X 0) oval)* L RA (return air) Accessory parts Mounting screws... x Duct connecting flanges...x (double flanges at SA and EA sides) Slim- connection cable (gray: two wires)...x B K E OA (outside air intake) ore, air filter, High- Efficiency filter, fan, maintenance space More than 3 / (00) / ~ / (0~0) M Inspection opening 3/ (0) SA (supply air) Power supply cable opening Air supply fan ontrol box Maintenance cover F N 3 3/ () J core High-Efficiency filter (sold separately) attachment position A J N øg øh Model LGH-F300 RX LGH-F0 RX LGH-F00 RX Position where duct direction change is possible Dimensions eiling suspension fixture pitch Nominal Duct connecting flange Duct pitch A B D E F diameter G H J K L M N 3 / () / () / () 0 (0) 3 / (00) / (3) 3/ (3) 3/ (3) 3/ (3) Air filters 3 / () 3 3/ (00) 3 3/ (00) / (03) 0 3/ (03) 3/ (3) / () / (3) / (3) / (00) / (0) / (0) / () / () / () 3/ (0) 0 3/ () 0 3/ () 3 / () 3 / () 3 / () 3/ () 3/ (0) 3 / () / (3.) 3/ () 3/ () / () / () / () Unit: Inch (mm) 3/ (30) Weight lbs (3 kg) lbs (3 kg) 30 lbs ( kg) LGH-F00 RX Air exhaust fan Bypass damper plate 3 3/ (00) eiling suspension fixture (-/ X 3/ (- X 30) oval) EA (exhaust air outlet) 0 / (0) RA (return air) OA (outside air intake) A B 0 / (0) D SA (supply air) / (0) ore, air filter, High-Efficiency filter, fan, maintenance space More than 3 / (00) 3/ () / (00) / ~ / (0 ~ 0) cores Inspection opening / () / () 3 / () ø / (ø) ø0 3/ (ø) ø / (ø) ø0 3/ (ø) 3/ (3) 3 / () Air supply fan ontrol box Maintenance cover High-Efficiency filter (sold separately) attachment position Power supply cable opening Accessory parts Duct connecting flanges...x Mounting screws... x Slim- connection cable (gray: two wires)...x Air filters Unit: Inch (mm) Model A B D Weight / 3 / 3 / 0 / 0 lbs LGH-F00 RX (3) () () () ( kg)

Standard installation examples Duct length Model Distance LGH-F300 RX 3.3 ft ( m) or more LGH-F0, F00 RX. ft (. m) or more LGH- F00 RX. ft (3 m) or more The parts can also be installed upside down. Remove the maintenance cover, rotate the parts by 0, and re-install. EA (exhaust air outlet) OA (outside air intake) * Except F00 RX. unit Return air grille (not Included) Supply air grille (not included) English * It can be installed by inverting the top and the bottom. OA (outside air intake) EA (exhaust air outlet) Maintenance space Inspection opening unit After installing the duct connecting flange, remove the maintenance cover. Turn the cover by 0, and then reinstall it. Downward gradient of duct: /30 or more (toward wall side) and provision of distance in table below (to prevent rain water from seeping in) Duct Maintenance space Inspection opening Anchor bolt (to be provided by user) EA (exhaust air outlet) OA (outside air intake) EA (exhaust air outlet) OA (outside air intake) Electrically operated damper (Protection against the intrusion of cold air while is stopped in winter) (To be provided by the customer) unit Deep hood (to prevent rain water from seeping in) OA (outside air intake) EA (exhaust air outlet) unit Inspection opening (. X. or X ft (0 X 0 or 00 X 00 mm)) Remote controller (optional parts) SA RA (supply air) (return air) Supply air grille (not included) Return air grille (not included) In a region where there is risk of freezing in winter, it is recommended to install an Electrically operated damper, or the like, in order to prevent the intrusion of (cold) outdoor air while is stopped. Installation method Installing the unit. Preparing the anchor bolts Mount the washers (outer diameter of >3/ inch for 3/- UN ( mm for M0) >/ inch for /- UN ( mm for M) and nuts onto the pre-recessed anchor bolts (3/- or /- UN (M0 or M)), as shown in the figure below. Anchor bolt (3/- or /- UN (M0 or M)) Nut Washer Nut AUTION Before attaching the duct connecting flanges, check that no foreign matter (scraps of paper, vinyl, etc.) has found its way inside to unit. Attach the duct connecting flanges with the packing at the SA and RA sides. 3. Mounting unit () Hang the ceiling suspension fixtures on the anchor bolts and adjust in such a way that unit is level. () Tighten up securely using double nuts. Models LGH-F300, F0, F00 RX. Attaching the duct connecting flanges Use the supplied screws to secure the duct connecting flanges to the unit. Models LGH-F300, F0, F00 RX Anchor bolt eiling suspension fixture Duct connecting flange (Accessory parts) Mounting screw (Accessory parts) Model LGH-F00 RX Mounting screw (Accessory parts) Washer Nut Model LGH-F00 RX Nut Washer eiling suspension fixture Washer Anchor bolt (3/- or /- UN (M0 or M)) Duct connecting flange (Accessory parts) AUTION When suspending unit from the ceiling, do not handle it in such a way that force will be applied to the control box. Install the anchor bolts to ensure the product's weight or earthquake load. (orrectly rated wire/chain may also be used) 3

Installation method (continued) If the suspension bolts are short, change the mounting hardware. For the models LGH-F0 and F00 RX () Remove the suspension fixture and mount it to the upper mounting position. () Replace screws in the holes for the suspension fixture that has been removed to prevent air leakage Suspension fixture. AUTION Before attaching the ducts, check that no (debris or any other) foreign matter (scraps of paper, vinyl, etc.) has found its way inside the ducts. Do not touch the damper plate inside unit when connecting the ducts. If it is expected that the ambient temperature around the place where the unit is installed will be high during the summer air conditioning season, it is recommended that the indoor duct work be covered with insulation material. Do not carry out the following types of duct construction. (Doing so could cause a drop in the air volume and generate abnormal noises.) Extremely sharp bends Multiple bends Bends right next to the outlet Extreme reduction in the diameter of the connected ducts Screws Models LGH-F0 and F00 RX. onnecting the ducts () Fasten the duct securely to the duct connecting flange, and wrap aluminium tape (not included) around the joints so that there is no air leakage. () Suspend the ducts from the ceiling so that their weight will not be applied to the unit. (3) The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming.. When changing the direction of the out door side duct (EA/OA) Except for LGH-F00 RX () Removal of flange cover Unscrewing the flange cover mounting screws ( pcs), remove the flange cover. eiling suspension fixture Models LGH-F300, F0, F00 RX Duct Flange cover Mounting screw (for flange cover) Taping Heat-insulating material Outdoor duct Aluminium tape unit () Installation of duct connecting flange. Install the duct connecting flange using attached mounting screws.. Fix the removed flange cover with the removed mounting screws ( pcs). Duct connection flange eiling suspension fixture Duct connecting flange Model LGH-F00 RX Heat-insulating material Taping Duct Mounting screw (Accessory parts). AUTION After installing the unit, attach the supplied screw caps to the screws at the bottom of the unit. Models LGH-F300, F0, F00 RX Model LGH-F00 RX Duct connecting flange Aluminium tape Heat-insulating material Outdoor duct unit Duct connecting flange Screw Screw cap Screw Screw cap

Installation method (continued) Electrical installation With this product, the wiring installation method will vary according to the design of the system. Perform electrical installation to meet local electrical regulations. * Always use double insulated PV cable for the transmission cables. * Wiring work must be performed by qualified professionals. * All supply circuits must be disconnected before obtaining access to the terminal devices. English Names of components in control box Models LGH-F300, F0, F00 RX Model LGH-F00 RX TM LED LED LED LED LED LED TM SW, SW TM SW, SW TB TM SA, SA TB SA, SA TM3 M M N3 TH(OA) TH(RA) TM3 X X * N N TM BLAK GRAY YELLOW * BULE WHITE 3 SW SA SA TB(*) A B BROWN TAB3 N0 N SW TM3 Wire connection diagram ----- Models LGH-F300, F0, F00 RX * onnect the wires shown as thick lines. * Be sure to connect the ground wire. * A power supply isolator must be installed when wiring power supply to unit. * Always use a single pole isolator for the main switch power connection. SUPPLY FAN MOTOR EXHAUST FAN MOTOR Bypass or Delay monitor output Malfunction monitor output MAX 0 VA A VD A MIN 0 VA 00mA VD 00mA V or V D Mr.Slim (non-polar) * LGH-F0 and F00RX has capacitors. X0 TAB N N TM 0 TAB TAB N N TM BROWN BROWN 0V BROWN.3 A TB(M-NET) A 0V.3 A YELLOW PZ- 0DR-E PZ- 0DR-E B S TR TM L L PE HAR Operation or Delay monitor output MAX 0 VA A MIN 0 VA 00mA VD A VD 00mA nd remote controller S (Max. remote controllers installable) nd unit (Up to max. units) Transmission cable (non-polar) Shielded Wire M-NET-transmission cable MELANS LS L L GM POWER SUPPLY 0-30V~ 0Hz * When the optional Remote ontroller PZ-0DR-E is used as the M-NET System, connect it to, of TM terminal block, and connect M-NET transmission wire to A, B of TB terminal block. nd or later main units PZ-SLB-E and PZ- SF-E cannot used when using PZ-0DR-E nd Remote ontroller (Max. remote controllers installable) TM Definition of symbols M: Motor for exhaust fan M: Motor for supply fan : apacitor GM: Motor for Bypass movement LS: Micro switch TH: Thermistor for outside air TH: Thermistor for return air SW: Switch (Main/sub change), : Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) TM: Terminal block (Transmission cable and monitor output) TB: Terminal block (M-NET Transmission cable) TAB, TAB: onnector (Power supply) TR: ontrol circuit transformer X0: Relay contact X: Relay contact X: Relay contact N: onnector (Transformer primary) N: onnector (Transformer secondary) N: onnector (Thermistor) N: onnector (Micro switch) N: onnector (Motor for bypass operation) TAB3: Tab connector (Fan motor) TAB: Tab connector (Fan motor) N: onnector (Fan motor) N0: onnector (Fan motor) N: onnector (High/Low/Extra Low/BY-PASS switch) N3: onnector (Remote control selection) SA: Address setting rotary switch (0 digit) SA: Address setting rotary switch ( digit) LED: Inspection indicator lamp LED: Inspection indicator lamp LED: Power supply indicator lamp SYMBOL : Terminal block : onnector : Board insertion connector or fastening connector of control board.

Installation method (continued) Wire connection diagram ----- Model LGH-F00 RX * onnect the wires shown as thick lines. * Be sure to connect the ground wire. * A power supply isolator must be installed when wiring power supply to unit. * Always use a single pole isolator for the main switch power connection. M SUPPLY FAN MOTOR M EXHAUST FAN MOTOR M SUPPLY FAN MOTOR M EXHAUST FAN MOTOR PURPLE GRAY YELLO HITE PURPLE GRAY YELLO HITE x03 x0 x0 x03 x0 x0 N3 TH(OA) TH(RA) X X PURPLE x03 GRAY x0 YELLO x0 x03 x0 HITE x0 N N TM3 TM 3 Bypass or Delay monitor output Malfunction monitor output MAX 0 VA A VD A MIN 0 VA 00mA VD 00mA N0 N V or V D Mr.Slim (non-polar) TAB3 0 V.3 A TAB TAB TAB N N N SW TR BLAK x30 BLAK x30 POWER SUPPLY 0-30V~ 0Hz TM HAR PZ- 0DR-E SW TM Operation or Delay 0 monitor output SA SA X0 MAX 0 VA A MIN 0 VA 00mA VD A VD 00mA PZ- 0DR-E TB(*) nd remote controller (Max. remote controllers installable) A B S nd unit (Up to max. units) Transmission cable (non-polar) Shielded Wire M-NET-transmission cable MELANS L L PE YELLO YELLO * When the optional Remote ontroller PZ-0DR-E is used as the M-NET System, connect it to, of TM terminal block, and connect M-NET transmission wire to A, B of TB terminal block. L L GM LS GM LS TB(M-NET) A B S PZ-SLB-E and PZ-SF-E cannot used when using PZ-0DR-E nd remote controller (Max. remote controllers installable) nd or later main units M: Motor for exhaust fan M: Motor for supply fan : apacitor GM: Motor for Bypass movement LS: Micro switch TH: Thermistor for outside air TH: Thermistor for return air SW: Switch (Main/sub change), : Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) Definition of symbols TM: Terminal block (Transmission cable and monitor output) TB: Terminal block (M-NET Transmission cable) TAB, TAB: onnector (Power supply) TR: ontrol circuit transformer X0, X, X: Relay contact X0, X0, X03: Relay Supply fan speed control X0, X0, X03: Relay Exhaust fan speed control X30: Relay Motor for Bypass movement N: onnector (Transformer primary) N: onnector (Transformer secondary) N: onnector (Thermistor) N: onnector (Motor for Bypass operation) TAB3: Tab connector (Fan motor) TAB: Tab connector (Fan motor) N: onnector (Fan motor) N0: onnector (Fan motor) N: onnector (High/Low/BY-PASS switch) N3: onnector (Remote control selection) SA: Address setting rotary switch (0 digit) SA: Address setting rotary switch ( digit) SYMBOL : Terminal block : onnector : Board insertion connector or fastening connector of control board.

Installation method (continued) onnecting the power supply cable. Remove the screws and the control box cover Models LGH-F300, F0, F00 RX Screw ontrol box cover Model LGH-F00 RX ontrol box cover ontrol box cover The following system configuration can be created. onnect the necessary parts. When connecting with remote controller (PZ-0DR-E, PZ-SLB-E). When interlocked with indoor unit of air conditioner or other external device including other manufactures. 3 When interlocking with a pulse output device. When operating multiple units. When take malfunction monitor output, or take Bypass operation monitor output. When connect to an Electrically operated damper, or take operation monitor output. When switching High / Low / Extra-Low speed externally (when O sensor or other device is connected). When switching Bypass externally. When using the remote/local switching and the ON/OFF input (level signal) 0 When connecting to the ity Multi, remote controller (PZ-SF-E) or Mitsubishi Electric Air-onditioner Network System (MELANS). English Screw AUTION When connecting external devices (electrically operated damper, lamp, monitoring unit, etc.) using output signals of the unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment.). onnecting the power supply cable and transmission cable Pass the power cable through the bush* and connect to the TM terminal block using the round terminals. onnect the ground wire to the ground terminal and secure tightening the bush. (*: for PG connector or the like) Models LGH-F300, F0, F00 RX TM Power supply cable Ground wire PG connector Power supply cable Bush Insert the cutting ord clip Transmission cable When connecting with remote controller (PZ-0DR-E, PZ- SLB-E) * When controlling units with the central control, connect wires according to 0. Securely connect the transmission cable (PV insulated PV jacketed and either between AWG (ø 0.) and AWG (ø.), or between AWG (0.3 mm ) and AWG (. mm ) in cross section) from the remote controller to and of the input terminal block (TM). (No polarity) If there are two remote controllers, connect them in the same way. Note Don t tighten screws of terminal block with a torque larger than 0. Nm. It could damage the PB. Number of transmission wires which can be connected to single input terminal is up to wires for AWG (ø 0.) PV wire or AWG (0.3 mm ) stranded wire. It is up to wires for any other wires. PZ-SLB-E cannot be used when MELANS centralized control of the is used. PZ-0DR-E and PZ-SLB-E cannot be installed simultaneously. Model LGH-F00 RX ord clips Up to two remote controllers (PZ-0DR-E or PZ-SLB-E) can be used. Bush Power supply PG connector Insert the cutting Remote controller input terminal TM Ground wire Power supply cable AUTION Always separate the power supply cable and transmission cable by ( cm) or more to prevent malfunctioning of the unit. If the length of the stripped power cables wires is too long, the conductors may touch and short out. Power supply cable size : AWG (ø.) or more. () Tighten the ground wire and transmission cables to the terminal block. () Secure the transmission cables using the cord clips. Upon completion of the wiring connections, replace the control box cover. Transmission wires When interlocked with indoor unit of air conditioner or other external device including other manufactures () onnect the output signal cable from the external device to the input terminal block (TM) of the external controller. AUTION The connection may vary according to the output signal type of the external unit. Don t tighten screws of terminal block with a torque larger than 0. Nm. It could damage the PB.

Installation method (continued) () onfirm that the pulse input switch (-) is set to OFF. (Set to OFF at time of shipment.) When using Mitsubishi Mr. Slim air conditioner with MA Remote controller onnect the interlocking cable connector side to NL on the circuit board for the indoor Mr. Slim unit, then connect the lead wire side to the and of the input terminal block (TM) for the external controller input. (No polarity) Always separate the power supply cable and the Slim- connection cable by ( cm) or more to prevent the unit from malfunctioning. The Slim- connection cable is / (0. m) long. When wiring, extend it as far as necessary. Note Power supply External controller input (TM) Within yd (00 m) External device Slim- connection cable (Enclosed accessory) White Red Operating switch for external device NL Mr. Slim (Indoor unit) Printed circuit board External control input (TM) AWG 0 (0. mm ) to AWG ( mm ) sheathed PV cable External device or VD Overall connection extension length (Follow the operation manual for the external equipment.) Remote controller (PZ-0DR-E or PZ-SLB-E) Power supply The remote controller (PZ-0DR-E, PZ-SLB-E) cannot be used with this system. Use MA remote controller of Mr. Slim for switching ON/OFF or the fan speed. The ventilation mode is automatic ventilation. The Slim- connection cable may be extended to a maximum length of yd (00 m). (Extension cable specifications are as detailed below) Ensure that all connections are secure and that the appropriate insulation is provided. Use extension cable sheathed PV cable or cable AWG 0 (0. mm ) to AWG (.0 mm ). When the external device has a charged operating signal of VD or VD onnect the operating signal (wire) from the external device via the remote output to and on the external control input terminal block (TM). (No polarity) When the external device has an uncharged a-contact signal onnect the operating signal (wire) from the external device via the remote output to and 3 on the external control input terminal block (TM). External controller input (TM) AWG 0 (0. mm ) to AWG ( mm ) sheathed PV cable Within yd (00 m) External device Uncharge a-contact AUTION If an optocoupler or any other type of polar coupler is used at the uncharged a-contact, connect the positive side to 3 and the negative side to. 3 When interlocking with a pulse output device () Move the pulse input switch [-] to the ON position. (Refer to function settings Settings for pulse input.) () onnect the pulse output device (i.e., building management system) to the external control input terminal block [TM]. A pulse width of at least 00 msec will be needed. When using PZ-0DR-E, it can be set also from the remote controller. onnecting methods vary depending on the types of pulse signal Refer to Section When the external device has a charged operation signal of VD or VD or When the external device has an uncharged a-contact signal. ON 3 0 When operating multiple units () onnect from Unit to Unit, and from Unit to Unit 3 and so on up to a maximum of units ( units for F00) using a transmission cable (PV insulated PV jacketed and either between AWG (ø 0.) and AWG (ø.), or between AWG (0.3 mm ) and AWG (. mm ) in cross section). () hange the setting on the main/sub switch (SW) on the second and subsequent units to Sub. Power supply Power supply (Main) (Sub) (Sub) Power supply MAX units Remote controller (PZ-0DR-E or PZ-SLB-E) External device Power supply Operating switch for external device ON OFF Main/Sub selection switch (SW) Main Sub (Factory setting: main) First TM onnect to remote controller TM Second (PZ-0DR-E) onnect to third Transmission cable AUTION Don t tighten screws of terminal block with a torque larger than 0. Nm. It could damage the PB. Note Up to four AWG (0.3 mm ) stranded wires or AWG (ø 0.) PV wires can be connected to one input terminal. For other types of wire, up to two can be connected. The operation signal and pulse signal can be connected to the external device of the main only. onnect the power to each respective unit. When LGH-F00RX is connected, they operate at low fan speed even if extra low fan speed is selected.

Installation method (continued) When take Malfunction monitor output, or take Bypass operation monitor output. Bypass operation indicator Lamp or monitoring unit Power Supply Monitor output terminal TM3 Bypass operation signal contactor rating Max 0 VA, A VD, A Min 0 VA, 00 ma VD, 00 ma Malfunction signal Malfunction indicator onnect to and, or and of the monitor output terminal block (TM3) with reference to the wire connection diagram. Note * Don t tighten screws of terminal block with a torque larger than 0. Nm. It could damage the PB. Bypass or Delay monitor output with delay function can be possible. (Refer to function settings 3 Setting for TM3 ) To force Extra-Low fan speed externally O sensor, etc. (When O decveases: losed) SW SW: Low fan speed operation switch (When closed: For Low fan speed operation) Remote ON/OFF adaptor (Optional) PA-SAHA-E control board Brown Red N Orange 3 Yellow Green Not used. Insulate completely. Max wiring length 3ft (0 m) Fan speed/ Ventilation mode selection When SW is "ON", fan speed of the will be set to "Extra-Low" regardless of the remote control setting. Use this in such a way that it ventilates at High fan speed normally, and when the external sensor detects that the indoor air contamination is low, it changes to Extra-Low fan speed operation. * For LGH-F00RX, fan speed of the will be Low. English When connect to an Electrically operated damper, or take Operation monitor output onnect the power supply cable from the Electrically operated damper to and 0 of the monitor output terminal block (TM) with reference to the wire connection diagram. Operation monitor output with delay function can be possible. (Refer to function settings Setting for TM 0 ) Power Supply Monitor output terminal (TM) Electrically operated damper SW SW 0 Lamp Note * Don t tighten screws of terminal block with a torque larger than 0. Nm. It could damage the PB. * Response times to external input signals are as shown in the following table. ontactor rating Max 0 VA, A VD, A Min 0 VA, 00 ma VD, 00 ma When switching High/Low/Extra-Low fan speed externally (when O sensor or other equipment is connected) Using marketed O sensor, etc., make connection by inserting the optional remote ON/OFF adaptor (PA-SAHA-E) in the connector N (High/Low selector) as shown by the figure. To force High fan speed externally O sensor, etc. (When O increases: losed) SW: High fan speed operation switch (When closed: For High fan speed operation) When SW is "ON", fan speed of the will be set to "High" (Extra- High) regardless of the remote control setting. Use this in such a way that it ventilates at Low or Extra-Low fan speed normally, and when the external sensor detects contamination of indoor air, it changes to High (Extra High) fan speed operation. To force Low fan speed externally O sensor, etc. (When O decreases: losed) SW: Low fan speed operation switch (When closed: For Low fan speed operation) Remote ON/OFF adaptor (Optional) PA-SAHA-E Brown Red Orange 3 Yellow Green Not used. Insulate completely. Max wiring length 3 ft (0 m) Remote ON/OFF adaptor (Optional) PA-SAHA-E Brown Red Orange 3 Yellow Green Not used. Insulate completely. Max wiring length 3 ft (0 m) External Signal Response Time Level Signal Max. sec. Pulse Signal Max. 00 msec control board When SW is "ON", fan speed of the will be set to "Low" regardless of the remote control setting. Use this in such a way that it ventilates at High fan speed normally, and when the external sensor detect that the indoor air contamination is low, it changes to Low fan speed operation. N Fan speed/ Ventilation mode selection control board N Fan speed/ Ventilation mode selection 0 When switching Bypass externally. Establish the wire connection by inserting the optional remote ON/OFF adaptor (PA-SAHA-E) in the connector N (Ventilation mode selector). SW SW: Bypass ventilation operation switch (When closed: For Bypass ventilation operation) With SW is ON, the ventilation mode of is changed to the Bypass ventilation regardless of the setting on the remote controller. * When the outdoor air temperature drops lower than. F ( ), it changes to the heat exchanger ventilation. (Display of the remote controller does not change.) When using the remote/local switching and the ON/OFF input (level signal) The remote controller (PZ-SLB-E) cannot be used. Insert the optional remote ON/OFF adaptor (PA-SERA-E) in N3 on the control PB. Remote control board Relay power supply SW Relay circuit X Y Remote ON/OFF adaptor (Optional) PA-SAHA-E Brown Red Orange 3 Yellow Green Not used. Insulate completely. Max wiring length 3 ft (0 m) X Y SW: When this is ON, cannot turn ON/OFF by the Remote ontroller (PZ-0DR-E, PZ-SF-E). : When SW is ON, can be turned ON by setting at ON or turned OFF by setting at OFF. SW: Remote/local selector switch : ON/OFF switch X, Y : Relay (ontactor rating D ma) Remote ON/OFF adaptor (Optional) PA-SERA-E Orange Red Brown 3 Max wiring length 3 ft (0 m) When connecting to the ity Multi, remote controller (PZ-SF- E) or Mitsubishi Electric Air-onditioner Network System (MELANS) * If centralized control is performed according the wire connection shown in this section, the remote controller (PZ-SLB-E) cannot be used. M-NET transmission cable input terminal block TB A B S control board N Fan speed/ Ventilation mode selection control board N3 Shielded wire M-NET transmission cable

Installation method (continued) One shielded wire is connected to TB S on the PB on terminal. Address setting is required. (Refer to function setting section.) M-NET transmission cable: onnect any of the ity Multi indoor unit, or Mitsubishi Electric Air-onditioner Network System (MELANS) - to the. onnecting positions are different for the Remote ontroller PZ-0DR- E and PZ-SF-E. PZ-0DR-E: onnect to TM, on the PB. (See Section When connecting with Remote ontroller (PZ-0DR-E).) PZ-SF-E: onnect to TB A, B on the same terminal block as for the M-NET transmission wires. Securely connect the M-NET transmission wires to TB AB. (No- Polar) Type: (Shielded wire, VVS / PEVS) Wire diameter: AWG (. mm ) to AWG (.0 mm ) AUTION Don t tighten screws on the terminal block with a torque larger than 0. Nm. It may damage the PB. Always use shielded wires only for the M-NET transmission wires, and finish the shield properly. When interlocking with Mitsubishi Free Plan air conditioner Incase of PZ-0DR-E Air conditioner MA remote controller Incase of PZ-SF-E Power supply unit Air conditioner M-NET transmission cable PZ-0DR-E M-NET transmission cable PZ-SF-E MELANS When connecting to PZ-0DR-E and MELANS onnect the power feeding unit. (Optional) Air conditioner MA remote controller Air conditioner M-NET transmission cable PZ-0DR-E * Limit the total length of transmission wires no longer than yd (00 m). Limit the wiring length between and the power supply unit (Optional) or the outdoor unit no longer than yd (00 m). Function settings Address setting is required when connecting to ity Multi, remote controller (PZ-SF-E) and MELANS. Setting the address Use the following procedure when setting the address for dedicated. (The method in determining the addresses will depend on the existing system. Refer to the appropriate technical documents for details.) () Remove the control box cover. () Use a flatblade screwdriver to turn the address setting switch on the circuit board. SA indicates the 0 digit and SA indicates the digit. The factory setting is "00" 0 SA SA 0 digit digit Address setting switch * When the address number has been changed, the data in the memory is automatically reset. hanging the function selection switches (SW- and ) Set the selection switches (SW- and ) to perform the appropriate function. * The function marked (*) above can be set also from the remote controller (PZ-0DR-E). If the function is switched later using the remote controller, it operates according to the setting on the remote controller. 3 0 3 0 () (SW) Trial operation Pulse input setting * Power supply/exhaust when operation starts * SA fan fixed at Low speed * EA fan fixed at Low speed * Power supply ON/OFF * Bypass ventilation priority at Automatic mode * Setting for TM 0 output Supply Extra High/High * Exhaust Extra High/High * Delay setting * Operation monitor output * Exhaust fan stop during defrosting * Exhaust fan at Low speed at outdoor air lower than F (- ) * Auto restoration after power failure * Filter maintenance indication setting * Setting for TM3 output } Interlock mode setting * Exhaust fan stop at outdoor air lower than F (- ) * Not used OFF: LGH-F300, F0, F00RX ON : LGH-F00RX Settings for pulse input Switching to power supply/exhaust when operation starts 3 Switching to the multi ventilation mode Power supply ON/OFF function (cannot be set when PZ-SLB-E is used) Bypass automatic ventilation priority setting * Setting for TM 0 output Extra High/High switch setting Set for delay operation at heating or cooling start-up Operation output monitor 0 Exhaust fan stop during defrosting, exhaust fan Low speed operation at outdoor air lower than F (- ) Settings for automatic recovery following power supply interruption (cannot be set when PZ-SLB-E is used) Settings for filter cleaning (cannot be set when PZ-SLB-E is used) 3 Setting for TM3 output Settings for interlock mode Exhaust fan stop at outdoor air lower than F (- ) *

Function settings (continued) Switching to power supply/exhaust when operation starts This sets the fan to run forcibly for 30 minutes when operation starts to ventilate the indoor area. After 30 minutes, the system switches to enable fan speed adjustment from the remote controller. Use this setting if the indoor air is contaminated at night when the system is shut down and you desire to ventilate the indoor area quickly when operation is started in the morning. Settings for pulse input Set as shown when connecting the pulse signal equipment from a building maintenance system to an external input. 3 OFF ON Mode No pulse input (factory setting) Pulse input 3 Normal (factory setting) 3 Runs the fan forcibly for 30 minutes when operation starts. Switching to the multi ventilation mode This sets the ventilation system to in the case that ventilation balance in accordance with the use environment and installation location is selected. There are four possible setting modes. OFF ON Mode Operation Power Ventilation Normal (factory setting) Power Supply Power Exhaust Power Save Ventilation The fan speed alternates between the High (Extra high) and Low instead of the remote controller setting. Runs the exhaust fan (EA) at Low speed constantly. Alternates the supply fan (SA) speed between the High (Extra high) and Low. Runs the supply fan (SA) at Low speed constantly. Alternates the exhaust fan (EA) speed between the High (Extra high) and Low. Runs the supply fan (SA) and exhaust fan (EA) at Low speed constantly. Switches to the Power Save Ventilation setting regardless of the remote controller s High or Low. * When using the Remote ontroller (PZ-0DR-E), operation of the Extra Low fan speed button initiates the Extra Low fan speed operation both at the supply (SA) and exhaust (EA) sides. Independent operation of the supply (SA) or exhaust (EA) side is prohibited when it is set at the Extra Low fan speed. Power supply ON/OFF function (cannot be set when PZ-SLB- E is used) ontrols stop and start operation by turning the power supply (0-30 V) for the on and off. OFF ON Mode Operation Off Stop and start is performed according to (factory setting) SW- settings when the power is on. Operation possible by turning power on On and off. Bypass automatic ventilation priority setting Two thermistors in the unit detect the indoor (RA) and outdoor (OA) air temperatures and automatically select the ventilation or Bypass ventilation. With this mode, however, priority is given to the Bypass ventilation. * This setting reflects to the night purge operation condition. When outdoor temperature (OA) is. F ( ) or higher within hours, then Bypass ventilation starts by the comparison OA and RA temperature. The lowest RA temperature of Bypass operation is. F ( ) (factory setting) When the night purge is set by the remote controller PZ- 0DR-E, night purge operation starts at a temperature of. F ( ) (within hours). When outdoor temperature (OA) is. F ( ) or higher within hours, then Bypass ventilation starts by the comparison OA and RA temperature. The lowest RA temperature of Bypass operation is. F ( ) When the night purge is set by the remote controller PZ- 0DR-E, night purge operation starts at a temperature of. F ( ) (within hours). Extra High/High switch setting Select this function when increased air volume is required or when the duct piping is longer. Supply fan (SA) - High fixed (factory setting) Supply fan (SA) - Extra High fixed. 0 Exhaust fan (EA) - High fixed (factory setting) 0 Exhaust fan (EA) - Extra High fixed Set for delay operation at heating or cooling start-up Delays operation for 30 minutes when ity Multi or Mr. Slim starts operating or when a external device starts operating. (If the PZ-SLB-E is used, set it at the remote control. ) SW OFF ON Mode No operation delay (factory setting) Operation delay of 30 minutes * This function is invalid with in hours restart Operation output monitor This setting is available when - is OFF. SW Setting for TM 0 output Operation monitor output orresponds to operation mode output (TM 0) based on SW- setting. (factory setting) Operation monitor output with delay function orresponds to operation mode output (TM 0) supply fan with following function. Starts the output (TM 0) 0 seconds after supply fan operates. continues to operate for 3 minutes after stopping the output (TM 0) aution : Fan may be operating after turn off the switch of the remote controller. OFF ON Mode orresponds to operation mode output (TM 0) exhaust fan (factory setting) orresponds to operation mode output (TM 0) supply fan (The operation monitor output is off when the supply fan is stopped for operation in cold regions or during the ity Multi or Mr. Slim defrost mode.) English

Function settings (continued) 0 Exhaust fan stop during defrosting, exhaust fan Low speed operation at outdoor air lower than F (- ) 3 Setting for TM3 output Sets the operation of the exhaust fan (when the air supply fan is stopped) during defrosting of the air conditioner when Mr. Slim or ity Multi indoor unit is connected to a duct. When the outdoor air is lower than F (- ), stop the operation of exhaust fan. (OA stop operation at cold region) SW 3 Exhaust fan operation (factory setting) 3 Exhaust fan stop, exhaust fan operation at Low speed at outdoor air lower than F (- ) Settings for automatic recovery following power supply interruption (cannot be set when PZ-SLB-E is used) Sets for automatic recovery following power supply interruption. SW OFF ON Mode Operation No automatic recovery (factory setting) Automatic recovery Stop after recovery Recover to operate in mode used before power outage Settings for filter cleaning (cannot be set when PZ-SLB-E is used) Set the schedule for filter cleaning based on the estimated concentration of dust in the air. Factory setting is unlimited. * When using PZ-0DR-E, it is also possible to indicate the cleaning cycle of filter (3,000 hours). SW OFF ON Maintenance time Unlimited (No FILTER display on remote controller) (factory setting) 3000 hours AUTION When the setting for the cumulative operation time of the is exceeded, the filter cleaning display will appear on the indoor unit remote controller or the remote controller. After cleaning the filter, the filter cleaning display can be reset. Refer to the operating instructions for the remote controller. SW Settings for interlock mode These settings indicate how should operate when external devices are started or stopped. (If the PZ-SLB-E is used, set it at the remote control.) SW Bypass ventilation operation monitor output. orresponds to operation mode output (TM3 ) of bypass damper. (factory setting) Operation monitor output with delay function. orresponds to operation mode output (TM3 ) supply fan with following function. Start the output (TM3 ) 0 seconds after supply fan operates but also when the thermistor for outside air (TH) detect 3 F (- ) or lower. Stop the output (TM3 ),when thermistor for outside air (TH) detects a temperature higher than F ( ) or stop the supply fan or malfunction of TH. continues to operate for 3 minutes, after stopping the output (TM3 ) Error code is shown on the remote controller and stop the output in case of following. ) TH detects higher than F ( ) within minutes after the output starts. ) TH detects F (-0 ) or lower, 0 minutes after the output starts. 3) TH detects continuously F (0 ) or higher for more than minute. aution: Fan may be operating after turn off the switch of the remote controller. OFF ON Mode Operation On/Off interlock (factory setting) On interlock Off operation External input given priority The will start and stop according to the operation of the external devices. Subsequent operation will be possible using the remote controller for the or MELANS. The will operate whenever external devices are operated. stop operation will be possible using its remote controller or MELANS. The will stop whenever external devices are stopped. start operation will be possible using its remote controller or MELANS. The will start and stop according to the operation of the external devices. ontrol via the remote controller or MELANS will only be possible when external devices are stopped. Exhaust fan stop at outdoor air lower than F (- ) Set the exhaust fan operation when the outdoor air is lower than F (- ). (Suction stop operation at cold region) SW Supply fan stop, exhaust fan normal operation (factory setting) Supply fan stop, exhaust fan stop Trial operation After the system has been installed and before the ceiling panel is installed, make sure that wires are properly connected, then test the system s operation, referring to the operation manual for the remote controller.. Trial operation using the remote controllers (PZ-0DR-E, PZ-SLB-E and PZ-SF-E) Follow the procedure shown in the operation manual for the remote controller the functions below. () Start operation. () Fan speed selection. (3) Function selection. () Stop operation.

Trial operation (continued). Stand-alone trial operation () Supply power to the unit. () Turn the trial operation switch (-) On. Operation will start with the High setting and with Bypass ventilation operating. (This will take approximately minute after the power is turned on.) (3) onfirm that the Bypass damper plate in the unit is operated. () Turn the trial operation switch (-) Off. Power will be supplied to the motor for the fan and operation will be performed at the High setting. Power will be supplied to the motor for the by-pass and operation of the damper plate will be performed. (Approximately minute) 3. omplete system trial operation Interlock system containing an indoor unit and/or external device Use the remote controller for the indoor unit or the operating switches for the external device and confirm that the indoor unit and are interlocked. If delay time has been set, check that the operates after the delay time has passed. If MELANS System Use MELANS to confirm the operation of the. English. If trouble occurs during trial operation Symptom Will not operate even when the operation switch for the remote controller (PZ-0DR- E, PZ-SLB-E) and/or operation switch for the remote controller (PZ-SF-E) is pressed. HO flashes in remote controller for (PZ-SF-E). When using M-NET, the operation switch of Remote ontroller (PZ-0DR-E), remote controller (PZ-SF-E) or MELANS is dead. Does not operate even when the operation switch for remote controller for (PZ-SF-E) or MELANS is pressed. Indoor unit or external device does not interlock. does not stop. The inspection indicator lamp (LED Green) in the control box flashes. The inspection indicator lamp (LED Red ) in the control box flashes. Remedy heck the power supply. (The specified power supply is single-phase 0-30 V ~ 0 Hz) heck for a short circuit or disconnection in the transmission cable. (heck that the voltage between terminals in the transmission cables is to VD for the PZ-0DR-E or PZ-SLB-E and 0 to 30 VD for the PZ-SF-E.) heck that the there is ( cm) or more separating the transmission cable from the power supply cable and any other transmission cables. Run the independently using the trial operation switch (-) and check if it runs. runs --> heck the signal lines doesn t run --> heck the power supply heck if there are three or more remote controller connected (PZ-0DR-E or PZ-SLB-E). (The maximum is two.) Perform the registration operation using the remote controller for the (PZ-SF-E) or MELANS. (Refer to the installation instructions for the remote controller for the or MELANS.) heck the power supply. (Specified power supply: single-phase 0-30 V, wire dia. AWG (ø.), switch capacity heck if the power supply unit is connected or not, and if the power is supplied or not (For a system with only, it is necessary to install the power supply unit.) heck the transmission wire for short-circuit or broken wire (heck if D 0-30 V is detected between the terminals of transmission wire). heck if a clearance of ( cm) is secured between the transmission wire and the power cable and other transmission wires. Run independently to see if it operates properly or not. operates --> Inspect the transmission wire doesn t operate --> heck the power supply heck whether or not there is a power supply unit and that the power has been turned on. (On systems with only a, a power supply unit is required.) heck if the pulse input switch (-) is off. (an be set from PZ-0DR-E) heck the overall cable length between the indoor unit or external device and. (Refer to technical publications or other such documents.) heck the connections at the external control input terminal block (TM). In the case of voltage charged or VD output device: onnect to external control input terminals and. In the case of uncharged a-contact output device: onnect to external control input terminals and 3. In the case of Mr. Slim (A control or K control): onnect to external control input terminals and. Perform the registration operation using the remote control for the air conditioner or MELANS. (Refer to the installation instructions for the remote controller for the indoor unit or MELANS.) heck if the delay has been set. heck the overall length of the transmission cable between the external device and. (Refer to technical publications or other such documents.) heck if the transmission cable from the external device has come off of the external control input terminal. Operation signal Stop signal harged or VD output device or VD 0 VD Uncharged a-contact output device Resistance: 0 Ω Unlimited resistance Ω Mr. Slim to VD (pulse signal) to VD (pulse signal) heck, in the case of multiple units, whether the Main/Sub selection switch on the unit which is connected to the external control input terminal is set on the Master setting, and check whether the Main/Sub selection switch on other units are set to Sub. heck that the trial operation switch (-) is set to off. flashes Fault on circuit 3 flashes Fault on Damper devices flashes Fault on thermostat (OA side) Turn the power off and consult your dealer. flashes Fault on thermostat (RA side) flashes Improper OA temperature (outside the range) On Operating Unless the Remote ontroller (PZ-0DR-E) or remote controller switch (PZ-SLB-E, etc) is used, the lamp extinguishes (operation stops) 30 minutes later. to flashes Error in M-NET communication Turn off the power and immediately contact your dealer. On Registration operation has not been performed. Use the controller to perform the registration. When an inspection number blinks on the remote controller, follow the procedures shown in the installation and operating manuals provided with the remote controller. If the remote controller is not used, operate after approximately seconds of turning on the power for the. 3