Digital High Volume Ambient Air Monitoring Systems 110 Volt

Similar documents
Portable Digital Flow Meter High Volume Air Samplers

Portable Digital Flow Meter High Volume Air Samplers

BATTERY BANK POWERED AC/DC AIR SAMPLERS

Analog Low Volume Air Samplers

F&J SPECIALTY PRODUCTS, INC.

BATTERY BANK POWERED AC/DC AIR SAMPLERS

Battery Powered Air Samplers Manufactured by F&J SPECIALTY PRODUCTS, INC.

ESCORT ELF and ESCORT LC SAMPLING PUMPS

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web:

Description. functions including single duct pressure dependent or pressure independent systems.


DIESEL Engine Fire Pump Controllers Features

Industrial Generator Set Accessories

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

Features and Benefits. Control Features

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Illuminator Series CR NEMA 3R

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Buck BioAire Model B520 Instruction Manual

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

Dual ground lug - one lug for earth ground, one lug for utility ground.

mass flowmeter for compressed air

GENCORE 5 FUEL CELL SYSTEM System Fundamentals

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

The UL Type 3R Package is specifically designed for Adjustable Frequency Drives, such as Yaskawa's E7, F7, G7, P7, and iqpump models.

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

1291BL Series Technical Specification Single Axis Position and Rate Table System

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

Model LA 4400 Time Delay OFF Controller

PowerView PV380-R2 Mechanical Configuration

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

A1 Commercial Grade Meters

Operators Manual. Recirculating Chiller /06/08

Concrete ASTM COMPRESSION TESTER ACCESSORIES

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

Industrial Generator Set Accessories

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

TE 88 MULTI-STATION FRICTION & WEAR TEST MACHINE

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Single-Phase Step Voltage Regulators

Turbidity and Suspended Solids Transmitter

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Buck BioSlide Model B1020 Instruction Manual

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

Luzchem Solar Simulator SolSim2 Updated September 2018

Coleman Air ITS-240 Inverter Transfer Switch

XS500 Load Bank. Read all instructions before using the load bank. Contents

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Instruments for the Analysis of Petroleum Products. Oxidation Stability

QUANTUM LX CONTROL PANEL

G2 Industrial Grade Meters

MAG. BR500 intelli BARRIER Intelligent Vehicle Barrier Gate. General Description. Application. Features

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

A1 Commercial Grade Meters

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

*Shown with optional high pressure blowers

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

ROBICON W120 enclosed drive


OPERATION AND MAINTENANCE

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

Single-phase step voltage regulators

Installation, Operation, & Maintenance Manual MODEL: MHR, MJTHR

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Outdoor Enclosure Power System ENC X100MP48F20-AC6

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

SECTION ELECTRIC MOTOR ACTUATORS FOR VALVES

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

Weather Protective Devices

REPLACEMENT PARTS ILLUSTRATION

Copyright 2017 ORIFLOW LLC. Operating Instructions for Cobra and Lynx Duct Leakage Testers

Transcription:

Digital High Volume Ambient Air Monitoring Systems 110 Volt DH-60810V.2 DH-504V.2 DH-604V.2 DH-804V.2 DH-30V.2 Revision Date: 01 January 2016

Copyright 2016 This operator manual and information contained herein is proprietary to and shall not be reproduced, copied in whole or in part, adapted or disseminated without the express written consent of 2

Table of Contents Page DH-60810V.2 4 5 DH-604V.2 6 7 DH-50810V.2 8 9 DH-504V.2 10 11 DH-804V.2 12 13 DH-30V.2 14 15 Contact Information 16 3

The Nucleus of Quality Air Monitoring Programs DIGITAL AIR MONITORING SYSTEM MODEL DH-60810V.2 NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with ± 3% of full scale Auto zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10,20,30 or 60 days Multiple on-board calculations with display Filter Holder 8 10 (20.3cm 25.4cm) 110 120VAC, 50/60Hz; single phase Vacuum Fluorescent Display; 2 24 characters Wide temperature range electronics GENERAL DESCRIPTION: The DH-60810V.2 Series Air Sampling Systems are designed for remote unattended continuous air sampling applications. The DH-60810V.2 Series Air Samplers feature a brushless motor with electronic motor speed control that maintains a user selectable flow rate. The flowrate range attainable through the filter media is dependent upon the air porosity of the filter media. The DH-60810V.2 Series design accommodates rapid field service and component replacement. The basic components of the system are assembled in a modular fashion so that each component can be readily and independently removed for service. For durability and weather resistance, the system is housed in a freestanding powder coat painted aluminum enclosure. The sample air is drawn in under the eaves of the hinged lid from all four sides and is exhausted near the bottom of the enclosure. The locking swing door on the enclosure provides convenient access for servicing the equipment inside. A lockable latch on the top cover restricts unauthorized tampering with the filter holder. The electronic flow control measurement sub-system of the DH-60810V.2 Series provides a standard flow measurement and a constant flow of air through the filter medium. The air velocity is measured by a precision-machined venturi. The controller can be readily set to any sampling flow rate between 20 and 70 CFM (560-1980 LPM) depending on the filter paper air resistance and dimensions. The bright VFD readout displays multiple air sampling information including current flow rate, average flow rate, current temperature and totalized volume. The filter holder can be custom designed to accommodate any filter size and type. The DH-60810 model utilizes an 8 10 (20.3 25.4cm) filter. Optional software is available to download air-sampling data via an RS-232 port. The software provides a monitoring report, file creation and setup via a laptop computer. 4

DH-60810V.2 (110 120VAC) Performance: Basic components of the system are modular and independently serviceable. Sample flow rate can be set between 20 and 70 CFM (560 and 1980 LPM). Filter holder is a 8 10 (20.3 25.4cm) diameter standard. Technology: Operating Temperature Range: Typical Flow Rate Range: Motor: Power: Microprocessor controlled state of the art electronics -31ºF to 122ºF (-35ºC to 50ºC) 20 70 CFM (560 to 1980 LPM) (Depending on filter paper dimensions and air resistance). Brushless: 1 H.P.(800 Watt) motor with electronic motor speed control 110-120VAC; 50/60Hz; 5 amperes; single phase. Housing: Powder coat painted aluminum Locking hinged cover Removable hinged cover Locking swing door with key Dimensions: 57.5 H 21.5 W 21.5 D (146cmH 54.6cmW 54.6cmD) Weight: Approximately 98 lbs. (44.5 Kgs.) Shipping Weight: Approximately 150 lbs. (68.2 Kgs.) Installation Category: Pollution Degree 3 Enclosure Rating: IPX3 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the electronic motor speed adjustment, if necessary, to maintain the flow within ± 3% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure. On-Board Measurement, Calculations and Other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC or PDA after completion of sampling activity Reusable wooden transportation crate Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10, 20, 30 and 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods within a week selectable by the user Utilization of 8 10 (20.3 25.4cm) diameter filters Vacuum Fluorescent Display; 2 24 characters 5

The Nucleus of Quality Air Monitoring Programs DIGITAL AIR MONITORING SYSTEM DH-604V.2 NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with ± 3% of full scale Auto zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10,20,30 or 60 days Multiple on-board calculations with display Filter Holder 4 (102mm) diameter 110 120VAC, 50/60Hz; single phase Vacuum Fluorescent Display; 2 24 characters Wide temperature range electronics GENERAL DESCRIPTION: The DH-604V.2 Series Air Sampling Systems are designed for remote unattended continuous air sampling applications. The DH-604V.2 Series Air Samplers feature a brushless motor with electronic motor speed control that maintains a user selectable flow rate. The flowrate range attainable through the filter media is dependent upon the air porosity of the filter media. The DH-604V.2 Series design accommodates rapid field service and component replacement. The basic components of the system are assembled in a modular fashion so that each component can be readily and independently removed for service. For durability and weather resistance, the system is housed in a freestanding powder coat painted aluminum enclosure. The sample air is drawn in under the eaves of the hinged lid from all four sides and is exhausted near the bottom of the enclosure. The locking swing door on the enclosure provides convenient access for servicing the equipment inside. A lockable latch on the top cover restricts unauthorized tampering with the filter holder. The electronic flow control measurement sub-system of the DH-604V.2 Series provides a standard flow measurement and a constant flow of air through the filter medium. The air velocity is measured by a precision-machined venturi. The controller can be readily set to any sampling flow rate between 20 and 50 CFM (560-1415 LPM) depending on the filter paper air resistance and dimensions. The bright VFD readout displays multiple air sampling information including current flow rate, average flow rate, current temperature and totalized volume. The filter holder can be custom designed to accommodate any filter size and type. The DH-604 model utilizes a 4 (102mm) diameter filter. Optional software is available to download air-sampling data via an RS-232 port. The software provides a monitoring report, file creation and setup via a laptop computer. 6

DH-604V.2 (110 120VAC) Performance: Basic components of the system are modular and independently serviceable. Sample flow rate can be set between 20 and 50 CFM (560 and 1415 LPM). Filter holder is a 4 (102mm) diameter standard. Technology: Operating Temperature Range: Typical Flow Rate Range: Motor: Power: Microprocessor controlled state of the art electronics -31ºF to 122ºF (-35ºC to 50ºC) 20 50 CFM (560 to 1415 LPM) (Depending on filter paper dimensions and air resistance). Brushless: 1 H.P. (800 watt) motor with electronic motor speed control 110-120VAC; 50/60Hz; 5 amperes; single phase. Housing: Powder coat painted aluminum Locking hinged cover Removable hinged cover Locking swing door with key Dimensions: 57.5 H 21.5 W 21.5 D (146cmH 54.6cmW 54.6cmD) Weight: Approximately 98 lbs. (44.5 Kgs.) Shipping Weight: Approximately 150 lbs. (68.2 Kgs.) Installation Category: Pollution Degree 3 Enclosure Rating: IPX3 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the electronic motor speed adjustment, if necessary, to maintain the flow within ± 3% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure. On-Board Measurement, Calculations and Other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC or PDA after completion of sampling activity Reusable wooden transportation crate Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10, 20, 30 and 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods within a week selectable by the user Utilization of 4 (102mm) diameter filters Vacuum Fluorescent Display; 2 24 characters 7

The Nucleus of Quality Air Monitoring Programs DIGITAL AIR MONITORING SYSTEM MODEL DH-50810V.2 NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with +/- 4% of full scale Auto zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10, 20, 30 & 60 days Multiple on-board calculations with display Filter Holder: 8 10 (20.3 25.4cm) 100-120VAC; 50/60Hz; 7.2 Amp; single phase Vacuum Fluorescent Display(VFD): 2 24 characters GENERAL DESCRIPTION: The DH-50810V.2 Series Air Sampling Systems are designed to provide reliable continuous air sampling. It features a controller that maintains the flow rate of sample air constant at a selectable value typically 40 to 50 CFM through the filter medium. TheDH-50810 Series with optional heating systems are designed for subzero temperature operation at remote sampling locations. The DH-50810V.2 Series design accommodates rapid field service and component replacement. The basic components of the system are assembled in a modular fashion so that each component can be readily and independently removed for service. For durability and weather resistance, the system is housed in a freestanding powder coat painted aluminum enclosure. The sample air is drawn in under the eaves of the hinged lid from all four sides and is exhausted near the bottom of the enclosure. The locking swing door on the enclosure provides convenient access for servicing the equipment inside. Also lockable latch on the top cover restricts unauthorized tampering with the filter holder. The electronic flow control measurement sub-system of the DH-50810V.2 Series provides a standard flow measurement and a constant flow of air through the filter medium. The air velocity is measured by a precision-machined venturi. The controller can be readily set to any sampling flow rate between 20 and 70 CFM depending on the filter paper air resistance and dimensions. VFD readout displays multiple air sampling information including current flow rate, average flow rate, current temperature and totalized volume. The filter holder can be custom designed to accommodate any filter size and type. The standard model is for commonly used 8 10 filters. Optional software is available to download air-sampling data via a RS-232 port. The software provides a monitoring report, file creation and setup via a laptop computer. 8

DH-50810V.2 (100-120VAC) Performance: Basic components of the system are modular and independently serviceable. Sample flow rate can be set between 20 and 70 CFM (560 and 1980 LPM). Filter holder is 8 10 (20.3cm 25.4cm)standard; The unit can be customized for other sizes. Technology: Microprocessor controlled state of the art electronics Temperature Operating Range: -31º to 122ºF (-18 to 50ºC) Storage Temperature Range: 0 to 158ºF (-18 to 70ºC) Typical Flow Rate Range: 20 70 CFM (560 1980 LPM) (Depending on filter paper dimensions and air resistance). Motor: Brushless regenerative blower. 1 H.P. motor Power: 100-120VAC; 50/60Hz; 7.2 amperes; single phase. A 40-amp breaker is recommended for startup of the motor. Housing: Powder coat painted aluminum Locking swing door with key Removable hinged cover Locking hinged cover Dimensions: 48 H 30 W 20 D (122cmH 76.2cmW 50.8cmD) Weight: Shipping Weight: Approximately 190 lbs. (96.4 Kgs.) Approximately 300 lbs. (136 Kgs.) Installation Category: Pollution Degree 3 Enclosure Rating: IPX3 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the position of the bypass valve, if necessary, to maintain the flow within ±4% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure. Utilization of a bypass valve flow control system enables the motor to always pump the maximum flow through the system without voltage reduction to the motor, which promotes longer motor life. On-Board Measurements, Calculations and other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC after completion of sampling activity Thermostatically controlled ceramic heater for enclosure Reusable wooden transportation crate Adapter to convert 8 10 filter geometry to 4 (102mm) diameter geometry. Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10,20,30 or 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods with an hour or within a week selectable by the user Utilization of 8 10 (20.3cm 25.4cm) filters Thermostatically controlled dual 250 cfm exhaust fans Vacuum Fluorescent Display: 2 24 characters 9

The Nucleus of Quality Air Monitoring Programs DIGITAL AIR MONITORING SYSTEM MODEL DH-504V.2 NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with +/- 4% of full scale Auto zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10,20,30 or 60 days Multiple on-board calculations with display Filter Holder 4 (102mm) diameter 100 120VAC, 50/60Hz; single phase Vacuum Fluorescent Display (VFD): 2 24 characters GENERAL DESCRIPTION: The DH-504V.2 Series Air Sampling Systems are designed to provide reliable continuous air sampling. It features a controller that maintains the flow rate of sample air constant at a selectable value typically 20 to 50 CFM through the filter medium depending on the air porosity of the filter media. The DH-504V.2 Series with optional heating systems are designed for subzero temperature operation at remote sampling locations. The DH-504V.2 Series design accommodates rapid field service and component replacement. The basic components of the system are assembled in a modular fashion so that each component can be readily and independently removed for service. For durability and weather resistance, the system is housed in a freestanding powder coat painted aluminum enclosure. The sample air is drawn in under the eaves of the hinged lid from all four sides and is exhausted near the bottom of the enclosure. The locking swing door on the enclosure provides convenient access for servicing the equipment inside. A lockable latch on the top cover restricts unauthorized tampering with the filter holder. The electronic flow control measurement sub-system of the DH-504V.2 Series provides a standard flow measurement and a constant flow of air through the filter medium. The air velocity is measured by a precision-machined venturi. The controller can be readily set to any sampling flow rate between 10 and 50 CFM depending on the filter paper air resistance and dimensions. VFD readout displays multiple air sampling information including current flow rate, average flow rate, current temperature and totalized volume. The filter holder can be custom designed to accommodate any filter size and type. TheDH-504V.2 model utilized a 4 (102mm) diameter filter. Optional software is available to download air-sampling data via an RS-232 port. The software provides a monitoring report, file creation and setup via a laptop computer. 10

DH-504V.2 (100 120VAC) Performance: Basic components of the system are modular and independently serviceable. Sample flow rate can be set between 20 and 50 CFM (560 and 1415 LPM). Filter holder is a 4 (102mm) diameter standard; the unit can be customized for other sizes. Technology: Operating Temperature Range: Microprocessor controlled state of the art electronics -31º to 122ºF (-35º - 50ºC) Storage Temperature Range: 0 to 158ºF (-18 70ºC) Typical Flow Rate Range: 20 50 CFM (560 1415 LPM) (Depending on filter paper dimensions and air resistance). Motor: Brushless regenerative blower. 1 H.P. motor Power: Housing: 100-120VAC; 50/60Hz; 9 amperes; single phase. A 40-amp breaker is recommended for startup of the motor. Powder coat painted aluminum Removable hinged cover Locking swing door with key Locking hinged cover Dimensions: 48 H 30 W 20 D (122cmH 76.2cmW 50.8cmD) Weight: Approximately 175 lbs. (79.5 Kgs.) Shipping Weight: Approximately 300 lbs. (136 Kgs.) Installation Category: Pollution Degree 3 Enclosure Rating: IPX3 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the position of the bypass valve, if necessary, to maintain the flow within ±4% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure. Utilization of a bypass valve flow control system enables the motor to always pump the maximum flow through the system without voltage reduction to the motor, which promotes longer motor life. On-Board Measurement, Calculations and other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC after completion of sampling activity Thermostatically controlled ceramic heater for enclosure Convertible to 8 10 (20.3cm 25.4cm)filter holder sampling system Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10, 20, 30 and 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods with an hour or within a week selectable by the user Utilization of 4 (102mm) diameter filters Reusable wooden transportation crate Vacuum Fluorescent Display; 2 24 characters 11

NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with ± 3% of full scale Auto zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10,20,30 or 60 days Multiple on-board calculations with display Filter Holder 4 (102mm) diameter 110 120VAC, 50/60Hz; single phase Vacuum Fluorescent Display; 2 24 characters Wide temperature range electronics Lightweight GENERAL DESCRIPTION: A lightweight semi-portable environmental high volume air sampling system designed for emergency monitoring activities to determine ambient air pollutants. The unit is field assemblable after site location. The Nucleus of Quality Air Monitoring Programs DIGITAL AIR MONITORING SYSTEM DH-804V.2 for Emergency Preparedness For durability and weather resistance, the system is housed in a freestanding powder coat painted aluminum enclosure. The sample air is drawn in under the stainless steel rain cover and is exhausted near the bottom of the enclosure. The locking swing door on the enclosure provides convenient access for servicing the equipment inside. A lockable latch on the door restricts unauthorized tampering with the controls. The electronic flow control measurement sub-system of the DH-804V.2 Series provides a standard flow measurement and a constant flow of air through the filter medium. The air velocity is measured by a precision-machined venturi. The controller can be readily set to any sampling flow rate between 20 and 50 CFM depending on the filter paper air resistance and dimensions. The bright VFD readout displays multiple air sampling information including current flow rate, average flow rate, current temperature and totalized volume. The filter holder can be custom designed to accommodate any filter size and type. The DH-804V.2 model utilized a 4 (102mm) diameter filter. Optional software is available to download air-sampling data to a PC or PDA via an RS-232 port. The PC software provides a monitoring report, file creation and setup via a laptop computer. 12

DH-804V.2 (110 120VAC) Performance: Basic components of the system are modular and independently serviceable. Sample flow rate can be set between 20 and 50 CFM (560 and 1415 LPM). Filter holder is a 4 (102mm) diameter standard. Technology: Operating Temperature Range: Typical Flow Rate Range: Motor: Power: Housing: Brushless: 1 H.P. motor Microprocessor controlled state of the art electronics -31ºF to 122ºF (-35ºC to 50ºC) 20 50 CFM (560 1415 LPM) (Depending on filter paper dimensions and air resistance). 110-120VAC; 50/60Hz; 9 amperes; single phase. Powder coat painted aluminum Locking swing door with key Dimensions: 26 H 26.5 W 16 D (66cmH 67cmW 41cmD) Weight: Approximately 60 lbs. (27.2 Kgs.) Shipping Weight: Approximately 100 lbs. (45.5 Kgs.) Installation Category: Pollution Degree 3 Enclosure Rating: IPX3 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the electronic motor speed adjustment, if necessary, to maintain the flow within ± 3% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure of the air flowing through the venturi flow sensor. On-Board Measurement, Calculations and Other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC or PDA after completion of sampling activity Reusable wooden transportation crate Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10, 20, 30 and 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods within a week selectable by the user Utilization of 4 (102mm) diameter filters Vacuum Fluorescent Display; 2 24 characters 13

The Nucleus of Quality Air Monitoring Programs MICROPROCESSOR CONTROLLED HIGH VOLUME AIR SAMPLING SYSTEM DH-30V.2 NOTABLE FEATURES: Precision machined venturi flow sensor Microprocessor controlled electronics Flow rate measurement and volume corrected to STP Display in English or metric units Programmable chain of custody identification RS-232 communication port Flow rate accuracy with +/- 4% of full scale Auto-zero calibration feature of flow sensor Various sampling modes to select from Data storage up to 10 days Multiple on-board calculations with display Filter Holder: Standard 15cm diameter enzyme dust sampling design 100-120VAC; 50/60Hz; single phase Vacuum Fluorescent Display; 2 24 characters Wide temperature range electronics GENERAL DESCRIPTION: The model DH-30V.2 High Volume Enzyme Dust Air Sampling System incorporates a low maintenance single-phase 110VAC; 50/60Hz brushless regenerative blower and state-of-the-art microprocessor controlled electronics. It will perform measurements, automatically control flow rate, perform on-board calculations and automatically shut off the unit after a preset totalized sample volume has been collected or prescribed sampling time has elapsed. All flow rate and volume measurements are corrected to Standard Temperature and Pressure (STP). The unit is mounted on a rugged portable stand and supplied with a cover plate and filter box designed for a 15cm diameter particulate filter. The DH-30V.2 system has the flexibility to be operated locally or via a PC through the RS-232 serial port. Remote communications with the system via a host PC is optional. Data may be downloaded via the RS-232 serial port to a PC or IPAQ PDA utilizing optional software including a report and graphical representation of the data on the PC. Local operation is implemented via a four-button keypad and a two line x 24-character VFD display. 14

DH-30V.2 (110 120VAC) Performance: Standard configuration is designed for Enzyme Dust Sampling applications. May be utilized for sampling of internal industrial air environment Technology: Microprocessor controlled state of the art electronics Temperature Operating Range: 0º to 122ºF (-18º to 50ºC) Typical Flow Rate Range: Motor: Power: Dimensions: 15 30 CFM; Dependent upon filter type and filter dimension being utilized Brushless regenerative blower. 1 H.P. motor 100-120VAC; 50/60Hz; 9 amperes; single phase A 40 amp breaker is recommended for start up 19 L 17 W 60 H (to top of particulate holder) [48.3 43.2 152 cm] Weight: Approximately 84 lbs. (38.2 Kgs.) Shipping Weight: Approximately 120 lbs. (54.5 Kgs.) Installation Category: Pollution Degree 2 Automatic Flow Control: The system microprocessor monitors flow rate relative to the preset STP flow rate established during the setup procedure and electronically adjusts the position of the bypass valve, if necessary, to maintain the flow within +/- 4% of setting. The microprocessor computes the STP flow rate by correcting for temperature and pressure. Utilization of a bypass valve flow control system enables the motor to always pump the maximum flow through the system without voltage reduction to the motor, which promotes longer motor life. On-Board Measurements, Calculations and other System Features Measurements: Temperature of air flow through system Inlet pressure to the flow sensor Differential Pressure of the flow sensor Calculations/Determinations: Totalized volume, STP Current flow rate, STP Minimum and maximum temperature Minimum and maximum inlet pressure Elapsed time Optional Items: Optional data communications software to download data from instrument to PC after completion of sampling activity Convertible to 8 10 filter holder sampling system Other System Features: Display of data in English or metric units by selection Automatic shut off of system on totalized volume or elapsed time Real time clock with battery backup Records up to 10,20,30 and 60 days of sampling data Dual password protection Operator password System Administrator password RS-232 port for communication with computer Periodic sampling scenario based on periods with an hour or within a week selectable by the user VFD Display; 2 24 characters Wide temperature range electronics 15

Fast & Friendly Customer Service Ordering by phone (352) 680-1177 / 680-1178 Ordering by Fax (352) 680-1454 For your convenience MasterCard, Visa & American Express Technical Assistance (352) 680-1177 16