INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

RANGER 900 POWER STEERING KIT

ECONOMIZERS. 5/2012 Supersedes

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

Installation Instructions

LXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES

IMPORTANT ATTENTION INSTALLERS:

Installation Instructions

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

ECONOMIZERS. 1/2012 Supersedes

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

2-row and All-row systems included.

Model 8144NC Fresh Air Ventilator

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Rzr Heater System Part #

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

Installation Instructions

INSTALLATION PROCEDURE, HHT WITH BULKHEAD. Vehicle prep

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

Chapter 3. Installing Equipment

Assembly Instructions

Installation Instructions

Factory Option Codes L M E S P R D V F F H E

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Installation Instructions

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

ZHA/ZHB SERIES WARNING

Engine Removal/Installation

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

TECHNICAL INSTRUCTIONS

RCA PLUG KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

WOC-364 Installation Instructions Ranger XP Heater System

ENERGY RECOVERY SYSTEM 60 HZ

Installation Instructions Part Number

IMPORTANT OWNER-OPERATOR INSTALLATION INSTRUCTIONS. A Hidden Power

850 TETHER SWITCH KIT

NOTE: CAPACITOR LEADS IN FIG #1 MAY REQUIRE SPLICING USING GA BUSS WIRE & SLEEVING AS NECESSARY TO ATTAIN REQUIRED LEAD LENGTH. 704

Installation Instructions

HANDLEBAR BAG WITH PHONE CHARGER KIT

TOYOTA TUNDRA TVIP V3 (RS3000) Section I - Installation Preparation

(1) Remote Control with (2) AAA Batteries

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE

Installation Instructions

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

Illustrated Parts & Packing List & Instructions 815 Rice Lake Street, Owatonna, MN 55060

ELECTRIC START KIT KIT P/N

CSA CERTIFIED Conforms to UL 507

Detroit Speed, Inc. Selecta-Speed Wiper Kit Corvette P/N:

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

SINGLE PACKAGE HEAT PUMPS

Installation Instructions

Vehicle Security / Remote Start / Remote Access System Installation

SMART ELECTRIC TAILGATE LIFT SYSTEM Document # Created ACH 09/19/2018 Revised ACH 10/02/18 A2

IMPORTANT SAFEGUARDS

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

APPROXIMATE ASSEMBLY TIME (R&R): 45 minutes -1-

Instructions for 2-row monitoring only

SUNLINE 2000 (WORLD 50 HZ)

Landmark Rooftop Packaged Units

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

Instructions for 2-row monitoring only

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

Installation Instructions

Installation Instructions

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

ENCORE 52" X-TREME. 2-BAG GRASS CATCHER for units w/ S/N and above ASSEMBLY AND PARTS DIAGRAMS

Mete-R-Matic F18 Top Dresser Starting Serial Number (U.S.A. Patent No. 5,307,952)

Transcription:

FOR 3 THRU 12.5 TON SINGLE PACKAGE EQUIPMENT General The instruction provides all the necessary information to properly field install this economizer on the above indicated equipment. Economizer Model 2EE04705924 has a single input solid state enthalpy sensor that provides automatic 100% outdoor air capability with 2% leakage. Refer to the respective unit wiring diagram for information regarding electrical circuitry on the economizer. A relief air damper for barometric air balance is provided with each basic unit and is mounted on the face of the return air damper section. Refer to the basic unit installation instruction for additional information. Step 1: Verify all unit parts in box. PANELS TO BE REMOVED a. 1 ea. - Return Air Damper b. 1 ea. - Fresh Air Damper c. 4 ea. - 24 5 8" x 23 1 8" x 1 Mist Eliminator Filter (shipped inside Return Air Damper) d. 1 ea. - Hood Package 1 ea. - Barometric Relief Hood 1 ea. - Barometric Relief Damper 1 ea. - Fresh Air Hood 1 ea. - Hardware Bag: 54 ea. - Type A #10-16 x ½ Screws 14 ea. - Self tapping #10-16 x ½ Screws 2 ea. - Seal Tight #10-32 x ½ Screws w / washers 4 ea. - Filter Clips 18 ea. - #8 Tinnerman Clips 10 ft. - 1 8 x ½ Gasket 11 ft. - 1 8 x ¾ Gasket RETURN AIR DAMPER HOOD PACKAGE FRESH AIR DAMPER

Step 2: Remove the Enthalpy Control and Discharge Air Sensor from the return air damper and save for later installation (Steps 3 and 15). ENTHALPY CONTROL Step 3: To assemble the fresh air hood the following will be needed. 34 ea. - Type A #10-16 x ½ Screws 4 ea. - Filter Clips 2 ea. - Seal Tight #10-32 x ½ Screws w/ washers 5 ft. - 1 8 x ½ Gasket Follow these steps: A. Take (1 and 2) and use the 2 Seal Tight screws with washers and screw though (2) into (1) and tighten. B. Take (3 and 4) and screw through (2) into (3 and 4) using the Type A screws. C. Take (5 and 6) and screw through (7) into (5 and 6) using the Type A screws. D. Take (8) and put to the inside of (2 and 7) and secure with Type A screws. E. Take (9) and place tabs into slots of (2 and 7) and bend tabs down on the outside of (2 and 7). F. Take (10) and place flanges with the three holes over (2 and 7) and secure with Type A screws. G. Take (11) and secure to (2, 7, 10) with Type A screws. H. Take filter clips and screw to (9 and 10) with Type A screws. I. Place gasket on the back flanges of (2, 7, 8, 10) J. Install filters in the hood and fasten clips to hold in place. Set Fresh Air Hood to the side for use in Step 13. (11) (5) FILTER CLIPS (7) DISCHARGE AIR SENSOR (6) 23 5 16 25 11 16 (9) (10) GASKET (3) 35 15 16 GASKET (4) (2) (8) ENTHALPY SENSOR (FROM STEP 2) GASKET (1) (2)

Step 4: To assemble the Barometric Relief Hood the following will be needed. 20 ea. - Type A #10-16 x ½ Screws 5 ft. - 1 8 x ½ Gasket 11 ft. - 1 8 x ¾ Gasket Follow these steps: A. Take (1 and 2) put the flange of (1) to the inside of (2) and screw in place. B. Take (3) and screw in place like step A. C. Take (4) and place flanges over (2 and 3) and secure. D. Take (5) and do the same as step C. E. Take 1 8 x ¾ gasket and place around perimeter of (6) to seal between damper section and hood. F. Take (6) and slide inside of (2 and 3) and secure. G. Place 1 8 x ½ gasket on flanges on (1,2, 3 and 5) that attach to the face of the economizer when installed. Set Barometric Relief Hood to the side for use in Step 13. (6) (5) (3) (4) 31 11 16 18 ½ (2) (1) 12 ¼ 21 9 16 25 ¼ Step 5: Remove the return air duct cover and the two (2) rear panels from the end of the unit as shown. Keep screws to use later in Steps 7 and 14. Note: Tinnerman clips have been supplied in case holes in the side flanges of the unit have been stripped. Attach (14) clips to the two side flanges as shown in figure. HORIZONTAL DUCT OPENING WITH COVER AND END PANELS REMOVED HOLES IN SIDE FLANGES FOR TINNERMAN CLIPS HOLES TO ATTACH RETURN AIR DAMPER Step 6: Install the fresh air damper into the horizontal return air duct opening as shown. Using the self tapping #10-16 x ½ screws provided secure to duct connection (two on each side). The two holes with bushings will be on the right hand side and the damper bracket will be on the damper bottom inside the unit. DAMPER BRACKET TWO HOLES WITH BUSHINGS

Step 7: Slide the return air damper into the unit as shown using some of the screws removed in Step 5. Step 8: Secure the return air damper to the unit with the screws removed in Step 6 through the slotted holes in the damper section. Do Not tighten screws at this time. Step 9: Connect the linkage from the return air damper to the fresh air damper. The linkage rod is shipped connected to the return air damper. To connect the linkage to the fresh air damper, open the fresh air damper and insert the rod through the opening in the damper bracket. With the rod through the fresh air damper bracket, close the fresh air damper tightly, and tighten the set screw on the fresh air damper bracket as shown. Note: A. Damper bracket is shipped in lower position. If installing in small cabinet reposition bracket to holes 8" above current location B. Linkage rod should be flush with the back of the fresh air damper bracket. NOTE A Step 10: Route the blue and violet wire from the Logic Module "+" and "S" terminals through the lower bushing provided in the fresh air damper as shown. These wires will be connected to the Enthalpy Control mounted on the fresh air hood as shown in Step 13.

Step 11: Plug the economizer cable into the unit as shown. The "jumper" plug that ships with the unit should be removed and saved in the control compartment for future needs. ECONOMIZER CABLE 3" Step 12: Install the assembled Barometric Relief Hood as shown. Using the "keyhole" slots on the barometric relief hood, place the barometric relief hood over the screws and slide down into the slots and tighten screws in place. Attach (4) tinnerman clips to the top flange of Barometric Relief Hood as shown in figure. This is the time to tighten all screws that were previously not tightened. FLANGE ON HOOD SIDE HOLES FOR TINNERMAN CLIPS Step 13: Install the assembled Fresh Air Hood as shown using #10-16 x ½ self tapping screws. Place fresh air hood approximately 3" down from top of the unit and flush with flange on hood side. Route wire to Enthalpy Control in the lower right hand corner of the Fresh Air Hood as shown. Connect the violet wire to the "+" terminal and the blue wire to the "S" terminal. Step 14: Reinstall the top rear panel which was removed in Step 5 of the unit using the remaining screws also removed in Step 5. TOP REAR PANEL

Step 15: The Discharge Air Sensor installs in the blower compartment of the unit. Open the access door to the blower and you will see a cable on the left side. The cable has two wires with insulated connectors that the Discharge Air Sensor plugs into. These wires are shown in the photo. Plug the Discharge Air Sensor wires into those provided inside the unit, and using a wire tie, strap the Discharge Air Sensor to the cable as shown below. DISCHARGE AIR SENSOR WIRES WIRE TIE DISCHARGE AIR SENSOR SEPTEMBER 11, 2009 YORK # 035-18285-001-A-0909 RSI FORM# YKIEC29FB

S7/P7 ECONOMIZER SECTION SOCKET /PLUG CONNECTION DAS DISCHARGE AIR SENSOR S12/P12 POWER EXHAUST SOCKET/PLUG CONNECTION M5 POWER EXHAUST CONTACTOR RC CAPACITOR NOTES: 1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY, LOCAL AND/OR NATIONAL CODES IN EFFECT AT TIME OF INSTALLATION OF THIS UNIT. 2. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSED IMPROPER AND DANGEROUS OPERATION. IF ANY OF THE WIRE, AS SUPPLIED WITH THE UNIT MUST BE REMOVED. IT MAY BE REPLACED WITH TYPE 105 DEGREE C, GOO VOLT WIRE OR EQUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION. VERIFY PROPER OPERATION AFTER SERVICING. 3. WHEN ECONOMIZER IS INSTALLED REMOVE PLUG WITH JUMPER WIRE 816/YEL