EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

Similar documents
Third Generation NITE Phoenix

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

No-Idle Units. NITE Phoenix System NITE Plus System NITE Battery Specifications NITE Day Cab System Espar Systems...

NEW! ClimaCab Customer Portal

AIR CONDITIONER 1. SYSTEM LAYOUT AND COMPONENTS Air Conditioner Controller FATC. Manual air conditioner

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

Emission-Free Comfort

INVERTER/CHARGERS Off-Grid Power Solutions

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

TriPac e. Electric Auxiliary Idle Reduction and Temperature Management System

Emission-Free Comfort

1. SPECIFICATIONS 01-2

TriPac e. Electric Auxiliary Idle Reduction and Temperature Management System

Installation Manual Blackhawk Road Rockford, IL

eapu Reference Guide System Component Information (For serial numbers starting with 37)

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810

TOTALINE PROTECTION CONTROLS

Idle Free Systems, Inc. Reference Guide System Component Information

An ISO 9001:2008 Registered Company

Operator s Manual. TriPac EVOLUTION Diesel Particulate Filter (DPF) TK OP (Rev. 2, 03/16)

Comfort Without Compromise

Model 377, 379, 386, 388, Sleeper no window

Air-Cooled Liquid Chiller with integrated hydraulic module

GUIDE SPECIFICATIONS. ES Series R-410A

R-22, 13 SEER 60 Hertz

On Road. Total comfort day or night PN: EcoSleeper Compact Fully Battery Operated DC Powered Modular A/C System

TriPac Evolution. The industry-leading APU that delivers lower operating costs and superior driver comfort.

A/C-HEATER SYSTEM - AUTOMATIC

Contents. Contents SYSTEM SYSTEM SYSTEM

A/C-HEATER SYSTEM - AUTOMATIC

ENGINE <4G6> 1-1 CONTENTS OVERVIEW... 2 COOLING SYSTEM... 4 MAIN UNIT... 2 INTAKE AND EXHAUST SYSTEMS... 4 LUBRICATION SYSTEM... 2 FUEL SYSTEM...

TriPac Envidia. All-electric APU with the longest run time in the industry for superior driver comfort.

A/C-HEATER SYSTEM - AUTOMATIC

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

ELECTRICAL SYSTEM RP-7

CONTENTS DELIVERING THE BEST RETURN ON INVESTMENT 1 FINDING THE RIGHT HEATING AND AIR-CONDITIONING SOLUTION 2

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

SERVICE & OWNER S MANUAL

Kenworth T680 without factory installed heater

D M S 760 C01 A A 1 1

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

Idle-Reduction Technologies. A White Paper To Discuss The Opportunity and the Challenges

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

RX400h. New Technology

Designed for ease of integration with automation systems

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Installation Manual. Cascadia. For Phoenix Gen 4 units built after 6/26/2017

4SHP18LS. Product Specifications. 18 SEER Split System Enhanced Heat Pump COMPONENTS COMPRESSOR CABINET DESIGN WARRANTY COIL

TriPac Envidia. Operator s Manual. TK OP (Rev. 0, 12/2017)

CWP-CO / CWP-RC / CWP-HP 02 to 35

Part # Features & Applications Specifications Cross Reference

Our complete line of refrigeration systems and performance options. Truck/Trailer/rail Product guide

Module 4: Climate Control

5073 Silver Peak Ave. Dacono, Colorado XV-LT #104

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

A/C SYSTEM SPECIFICATIONS

SMT-150 Installer Manual

AS-1535 SH User Guide

MODEL NUMBER: APS2424

Installation Manual. CH, CL, CXU, CXN and Vision Blackhawk Road P.O. Box 6007 Rockford, IL

4SHP18LS PRODUCT SPECIFICATIONS

Installation Manual #

MODEL NUMBER: APS2012

DESCRIPTION AND OPERATION

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

A/C SYSTEM SPECIFICATIONS

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

1991 TOYOTA Electrical Components MR2. evaporator. compartment. ARTICLE BEGINNING BUZZERS, RELAYS & TIMERS

CONFIGURATION DIAGRAMS

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

Installation Manual. 9000i Passenger side install Blackhawk Road P.O. Box 6007 Rockford, IL

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Installation Manual #

R-4122 Sleeper Heater/ Air Conditioner Unit. R-2550 Heater/Air Conditioner Unit RED DOT UNITS HEATER-A/C RESCUE VEHICLES

NITE SSI Service Parts List NITE Tech Support Line #

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

User Guide 1 WAY FM MANUAL TRANSMISSION REMOTE STARTER. Table of Contents. Introduction

REPLACEMENT PARTS MANUAL

EVERY COMFORT. THE CUMMINS COMFORTGUARD APU SYSTEM

TriPac. Hybrid Auxiliary Idle Reduction and Temperature Management System

A/C-HEATER SYSTEM - AUTOMATIC

Program IV: ProStar TM. Performance A/C International. Series. Study Guide Performance A/C Program IV: International ProStar Series TMT

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

G ELECTRICAL WIRING ROUTING

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

SUBMITTAL COVER SHEET

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

GCU-10. Automatic Engine Control Unit Operators Manual

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Heating Cable. Description

Transcription:

EFFICIENT SLEEPER COMFORT Volvo s Battery-powered Parking Cooler Option

Cooling comfort and anti-idle value. Most environmentally-friendly and efficient solution for sleeper comfort Overnight comfort without idling engine saves fuel, reduces engine wear, extends DPF life Quiet operation improves quality of sleep Virtually maintenance free

Power off, comfort on. Electrically-powered AC operates while truck ignition switch is in OFF position Can operate wherever vehicle is parked TMC-approved, rated to keep sleeper at 23 C (74 F) for up to 10 hours* *TMC RP 432A Criteria Factory-installed curtains closed. Initial sleeper temp 23 C (73 F) +/- 2 C (5 F). 34 C (100 F) ambient outside temp. 50% relative humidity. 600 W/m 2 solar load on vehicle roof.

Features Quiet operation Automatic temperature control 7,500 BTU/hour (2.2 kw) Start protection with smart battery management Integrates with optional Shore Power kit and inverter (additional run time and battery charging) Also controls diesel-powered parking heater (option); single thermostat control 3-year warranty CARB approved Exempt from FET

System components Starting batteries: (4) 925CCA AGM batteries located under driver s door Luggage compartment 120V inverter/charger & diesel-powered parking heater (recommended) 320A Leece-Neville alternator with remote battery sense and high amperage cables Back-of-cab condenser 120V shore power (recommended) In-frame auxiliary battery box with (4) 800CCA AGM (100-amp-hour) deep-cycle batteries and Bergstrom battery management Control/display inside sleeper on rear wall Parking unit in luggage compartment (evaporator, compressor, and blower connected to existing sleeper ducting)

System function Internal unit (evaporator assembly) Located under bunk, passenger side 50.5 x 43.4 x 31.2 cm, 19 kg (19.9 x 17.1 x 12.3 in, 42 lbs) Contents: - Evaporator - Blower (serviceable) - Compressor - Controllers (serviceable) - Thermostatic Expansion Valve (serviceable) Connected to sleeper ducting Brushless motors for extended life

System function External unit (condenser assembly) Located on BOC 52.6 x 14.5 x 35.8 cm, 8 kg (20.7 x 5.7 x 14.1 in, 18 lbs) Contents: - Condenser - Fan (serviceable) - Receiver drier (serviceable) Brushless motors for extended life

System function Components layout Bunk unit Ducting Parking unit Condenser Parking cooler is powered by both banks (8 batteries) until starting battery voltage level decreases to 12.4V. Battery isolator relay then disengages starting batteries to protect truck starting capacity. When starting batteries charged up to 13.2V, battery isolator relay reengages starting batteries to alternator charging circuit. Auxiliary battery bank (4) + battery management ECU Starting battery bank (4) Parking heater Inverter

System function Battery management Auxiliary batteries - dedicated to parking cooler - 4 deep-cycle AGM batteries, 800 CCA and 100 Ah each - in-frame battery box Battery management system (BMS) - mounted in auxiliary battery box - monitors voltage and current in/out of aux batteries - monitors battery charge status and health status - Controls battery isolator relay to engage/disengage auxiliary batteries from starting batteries.

Operating the system Starting the system Push ON/OFF button. This screen is the temperature set point screen. Display will show current mode/ temperature setting / battery level. Initial default setting is blower speed 1/ AUTO- MODE /72 F. ON/OFF Note: when the control is idle for 5 seconds, the screen will return to this temperature set point screen.

Operating the system Changing MODE Press ENTER. While mode is flashing, use up or down arrows to select AUTO / COOL / HEAT. After 5 seconds selection will be set. Note: when the control is idle for 5 seconds, the screen will return to the temperature set point screen. ENTER

Operating the system Changing blower speed Press ENTER until display shows FAN and SPEED. Press up or down arrows to select 1 2 3 speed. After 5 seconds selection will be set. Note: when the control is idle for 5 seconds, the screen will return to the temperature set point screen. ENTER

Operating the system Changing temperature set point Whenever the temperature set point is displayed on the screen, push the up or down arrows to change. Temperature range is from 60 F/ 16 C(coolest) to 85 F/29 C (warmest). NOTE: Control will always default to 72 F when the unit is turned on. Note: when the control is idle for 5 seconds, the screen will return to the temperature set point screen. UP/DOWN

Operating the system View system runtime hours Press ENTER until Hrs shows on display. This displays the total runtime of the parking cooler. To reset, press and hold ENTER for 7 seconds. Hours will be reset to zero. Note: when the control is idle for 5 seconds, the screen will return to the temperature set point screen. ENTER

Operating the system Change temperature scale ( F to C) Press ENTER until temperature symbol only shows. Push the up or down arrow to change. After 5 seconds selection will be locked. Note: when the control is idle for 5 seconds, the screen will return to the temperature set point screen. ENTER

Operating the system Service mode Push the ON/OFF and ENTER button simultaneously. Display will show service indicator and a code 00 unless a fault has occurred. If there is an active fault the display will show it as 01, 02, or 03. Use up and down arrows to scroll through the Fault Codes. (1) Evaporator sensor open or shorted high (2) Evaporator sensor shorted low (3) High pressure switch open or shorted high ON/OFF ENTER

Operating the system Service mode (continued) Press the ENTER button to proceed through the available service screens: 1. SV = Starting batteries Voltage 2. AV = Auxiliary batteries Voltage 3. AA = Unit Amperage draw Pressing ENTER arrow after viewing service screen will return you to the fault code screen. Pressing the ON/OFF button will return you to the Temperature Display screen.

Operating the system Check filter A Check Filter screen will notify you that the parking cooler filter must be cleaned or changed. To reset filter: at screen 1 press and hold enter button for 3 seconds.

Availability VNR 640 VNL 680 VNL 740 VNL 760 VNL 860

Weight exemptions (US only) Exemption varies by state: 181 249 kg (400 550 lbs.) Certified weight, including batteries: 256 kg (565 lbs.) State Recognition of Auxiliary Power Weight Exemption to GVW: 23 CFR 658.17(n)

Tips for maximum efficiency 1. Keep curtain closed between cab and the sleeper. 2. To enhance cooling efficiency during the day, place solar reflectors or curtains over windshield and all windows to block sunlight. 3. Volvo Parking Cooler is designed to maintain a comfortable temperature inside the sleeper without the engine running. It will not cool a hot sleeper that has been sitting in the sun without the factory A/C running. To assist the system in cooling down the sleeper, start the engine and run the factory A/C system until desired temperature is reached. Then use the Volvo Parking Cooler to maintain a comfortable setting.

Technical questions?