GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Similar documents
Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Specifications 54 Series Valve

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Bullet Valve (BV) Series

Bullet Valve (BV) Series

42 Series MAConnect TM. 42 Series Plug-In Manifold

MAC Pulse Valve PV06 Series

32, CONTENTS SMALL LARGE

MAC Pulse Valve PV03 Series

92 Series MAConnect with Sub D

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

MAC VALVES, INC. Rev. T

82 Series MAConnect with Sub-D

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

MAC VALVES EUROPE, INC.

Action Automation & Controls, Inc.

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

TECHNICAL BULLETIN. The main focus of MAC Valves is to offer an innovative product developed according to users experience and that provides:

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Chapter 10: Valves for Pipe Mounting

Directional Seat Valve Series D4S (Denison)

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

LYCOMING CYLINDER PRICING

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

F5 Valve F6 Valve F7 Valve

Miniature Valves MH1. Extremely small, fast and versatile. Info 206

2035 Series Solenoid Pilot Actuated Valves

Bus / Coach Door Obstruction Detection

Introduction Section 1 Section 2 Section 3

Section 2 Proportional Quick Exhaust

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

kysimply Unique Unique 7000 Series Y-Body

Miniature Multimedia Valves

2/2 and 3/2 way Flipper Solenoid Valve, with hermetic isolation of fluid. Low dead volume, low internal volume. High chemical resistance

Miniature Pneumatic Solenoid Valve

2012 Series Solenoid Pilot Actuated Valves

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =

EVP SERIES PROPORTIONAL CONTROL VALVES

Contact Air Incorporated for further assistance. Ph:

VA/VG Series On/Off and Shut-off Valve

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

ISO 5599/ Series Technical and Operating Data

UV-5(A/B)T Valve Exploded View

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Microbore Hose, Assemblies & accessories

Pressure Transmitters

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

NEW! MAXIMATIC SOLENOID VALVES

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Pressure Control Valves Series R. General Description. Specifications. Flow Data

Chapter 6: Check Valves

Valve Manifolds. Series Fielbus Electronics - 51

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural

Electrical Interface Dimensional Drawings Connector Kits

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve

1. SM0/SM00 Miniature Solenoids

Compact Proportional Solenoid Valve

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

3 Port Solenoid Valve Direct Operated Poppet Type

Series 40 Pumps Model Code Supplement Variable pumps model code

MINIATURE SOLENOID GENERAL SERVICE VALVES

2002 Series Solenoid Air Pilot Actuated Valves

Air Preparation Products

I23 RD P 16N 00

16mm miniature rocker solenoid valve with isolating diaphragm for special applications

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

HORSEPOWER TO MODEL NUMBER

Genesis Series Valves Parts List / Service Instructions

Technical Bulletin. MAC Valves, Inc., is pleased to announce. Introduction - Plunger up / Plunger Cooling / Counterblow Solutions

Серия MAC Pulse Valve PV06

Updated June Cylinder Application Charts

N1-DP N2-DP. External Pilot

3 Way/2 Position Valves

2005 Series Solenoid Pilot Actuated Valves

Transcription:

Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Individual mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways. 2. Patented conical seats for long life. 3. Short stroke with high flow. 4. Bonded poppet with minimal friction. 5. Wiping effect eliminates sticking. 6. Extremely repeatable response. HOW TO ORDER Pilot Single operator NC Valve 1/8 NPTF 1/4 NPTF 77A-11-A0A--- 77A-11-A0B--- 77A-11-B0A--- 77A-11-B0B--- DM - D - JA JC FB DA 110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/60 (2.9W) 24 VDC (5.4W) 24 VDC (12.7W) A B J 18 () 24 () Connector KD JD Square connector Square connector with light Rectangular connector Rectangular connector with light GM - G - DC DD 24 VDC (2.5W) 24 VDC (4.0W) A 18 B 24 C 36 BT KT with light Plug-in wire assy. Plug-in wire assy. with light

Series 77 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Coil : range: Protection : Power: Options: Compressed air, vacuum, inert gases Vacuum to 120 PSI ( pilot) 30 to 120 PSI ( pilot) 30 to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F 1.0 Cv Class A continuous duty, #22 AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory DC 12/24 Volt 1.0w to 5.4w (higher wattages available) AC 24, 120, 220, 240 VAC BSPP threads DIMENSIONS

Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Individual mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Sub-base OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways. 2. Patented conical seats for long life. 3. Short stroke with high flow. 4. Bonded poppet with minimal friction. 5. Wiping effect eliminates sticking. 6. Extremely repeatable response. HOW TO ORDER Pilot Single Operator NC Valve Valve less base 77A-13-00C--- 77A-13-00E--- 1/8 NPTF 77A-13-A1C--- 77A-13-A1E--- 1/4 NPTF 77A-13-B1C--- Note: Above models are side ported 77A-13-B1E--- DM - D - JA JC FB DA 110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/60 (2.9W) 24 VDC (5.4W) 24 VDC (12.7W) A B J 18 () 24 () Connector KD JD Square connector Square connector with light Rectangular connector Rectangular connector with light GM - G - DC DD 24 VDC (2.5W) 24 VDC (4.0W) A 18 B 24 C 36 BT KT with light Plug-in wire assy. Plug-in wire assy. with light OPTIONS 77A-13-00 C --xxx-xxx C pilot D * pilot with pilot exhaust out main exhaust E pilot 10 end F * pilot 10 end with pilot exhaust out main exhaust G pilot 12 end H * pilot 12 end with pilot exhaust out main exhaust 77A-13-A 1 C --xxx-xxx For bottom cylinder port, replace by 2 * Must use DU pilot body. Main exhaust cannot be restricted (i.e. 77A-13-00D-DU-DJAJ-1).

Series 77 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Coil : range: Protection : Power: Options: Compressed air, vacuum, inert gases Vacuum to 120 PSI ( pilot) 30 to 120 PSI ( pilot) 30 to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F 1.0 Cv Class A continuous duty, #22 AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory DC 12/24 Volt 1.0w to 5.4w (higher wattages available) AC 24, 120, 220, 240 VAC BSPP threads DIMENSIONS

Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Circuit bar mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Non plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways. 2. Patented conical seats for long life. 3. Short stroke with high flow. 4. Bonded poppet with minimal friction. 5. Wiping effect eliminates sticking. 6. Extremely repeatable response. HOW TO ORDER HOW TO ORDER VALVE FOR CIRCUIT R MOUNTING Pilot Single Operator NC Valve Valve less base 10 end 12 end 77A-13-00C--- 77A-13-00E--- 77A-13-00G--- DM - D - JA JC FB DA 110/50, 120/60 (2.9W) 220/50, 240/60 (2.9W) 24/60 (2.9W) 24 VDC (5.4W) 24 VDC (12.7W) A B J 18 () 24 () Connector KD ** JD** Square connector Square connector with light Rectangular connector Rectangular connector with light GM - G - ** These connector options require 26mm spacing - consult factory DC DD 24 VDC (2.5W) 24 VDC (4.0W) A 18 B 24 C 36 BT KT with light Plug-in wire assy. Plug-in wire assy. with light HOW TO ORDER CIRCUIT R (21mm spacing) Pilot air Side Cyl. Port Bottom Cyl. Port 1/8 NPTF 1/4 NPTF from 10 end* from 12 end* from 10 end* from 12 end* CBM77A-00AAA-xx CBM77A-00A-xx CBM77A-00ACA-xx CBM77A-00AAD-xx CBM77A-00ABD-xx CBM77A-00ACD-xx CBM77A-00A-xx CBM77A-00B-xx CBM77A-00BCA-xx CBM77A-00D-xx CBM77A-00BBD-xx CBM77A-00BCD-xx xx = number of stations (03 = 3 stations) Note: - For valves mounted on base at the factory, add -9 to the model number. - Common through ports are 3/8 *Common external pilot 1/8

Series 77 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Coil : range: Protection : Power: Options: Compressed air, vacuum, inert gases Vacuum to 120 PSI ( pilot) 30 to 120 PSI ( pilot) 30 to 120 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 210 F) 40 µ 0 F to 120 F 1.0 Cv Class A continuous duty, #22 AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory DC 12/24 Volt 1.0w to 5.4w (higher wattages available) AC 24, 120, 220, 240 VAC BSPP threads DIMENSIONS