Development of Power Conditioner with a Lithium Ion Battery

Similar documents
Development of the SANUPS P73K Power Conditioner with Peak Power Cut Function

Development of the Single Phase PV Inverter SANUPS P61A

Development of the 3-phase PV Inverter SANUPS P83D

Development of Utility Interactive Inverter for Photovoltaic Power System "PMB"

Technology that Evolves in Line with Market Changes

Technology from the New Product SANUPS K for a Smart Grid Society

MERU Solar Off-Grid Inverters

Application. Battery. Public Grid GS HYBRID INVERTER

Development of the Regenerative Power Compensation Device SANUPS K23A (R Type)

Development of the Small-Capacity UPS SANUPS A11K Series

All-in-one Storage Hybrid System

Energy Storage System for Home

500 / 630 / 720 / 760 / 800 / 850 / 900

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Large-scale Photovoltaic Power Generation Systems

Get ready for rising energy challenges. This is where xstorage Home can help

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Development of Emergency Train Travel Function Provided by Stationary Energy Storage System

Development of Small-capacity OFF-LINE UPS

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

Field Test of Green Base Station Designed for Environmental Friendliness and Reliability during Disasters. Research Laboratories

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Technical specifications

Development of Uninterruptible Power Supply SANUPS A11J Three-phase, Four-wire Model

Optimum Operation Control of Distributed Energy Resources Using ENERGYMATE-Factory

Hybrid UPS Saves Energy and Achieves High Reliability. Output capacity. 3 kva. 2 kva. Output capacity. 2.1kW. 1.4kW

Construction of power supply system using electric vehicle for stable power delivery from PV generation

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

BYD Distributed Energy Storage System (DESS) Integrated Type (European Version)

StorEdge Solar and Energy Storage System Review

ABB central inverters PVS to 1000 kw

Demonstration Project utilizing Hybrid Storage Battery System in the Oki-islands

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Delta All in One Storage Solutions

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

SOLON SOLiberty Energy Storage Solution. Greater Independence Through On-site Consumption.

Catch Eco Range : Technical Specification Sheet

Sungrow-Samsung SDI ESS Solutions. April 12, 2017

Magellan Utility Scale Energy Storage

ABB central inverters PVS to 1000 kw

Residential Energy Storage System SH 5K

Delta All-In-One Storage solutions

Session 3 - Mitigating economic repercussions of fluctuating voltage and consumption peaks

Lithium-Ion Battery Business

Solar inverter AX-series

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

SANUPS. Non Toxic Lead-Acid Batteries Online UPS. Maintenance-free for 10 Years. Compact and Lightweight. Constant, Stable-Quality Power Supply

CHARGE METHODS FOR NI-CD BATTERIES

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Control System for a Diesel Generator and UPS

Battery System User Manual for Panasonic LJ-SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ-SK56A

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Pika Energy Island Made in America

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

Illuminator Series CR NEMA 3R

Power Conditioning of Microgrids and Co-Generation Systems

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

K50. Technical Sheet

X600. Technical Sheet

Adaptive Fault-Tolerant Control for Smart Grid Applications

Alphapower HTU UPS. Some key features include:

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Magellan Stand Alone Power System (1P) Magellan Renewables Range

The evaluation of endurance running tests of the fuel cells and battery hybrid test railway train

2017 Southeastern Tri Regional SAME Training Symposium Microgrids What are they, lessons learned 8/30/2017 Dan Dorn Eaton Corp

Microgrid System for Isolated Islands

Feature Technical Developments in 2017

The Circuit and Control Technology in the Power Conditioner and Converter for Wind Turbine Systems

Energy Storage for Traction Power Supply Systems

Magellan Stand Alone Power System (3P) Magellan Renewables Range

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Power conversion systems for energy storage. Engineering that stores

PARALLEL PROCESSING UPS E33A

A DEVICE TO INCREASE ENERGY SELF-CONSUMPTION AND SELF-SUFFICIENCY

Power Whenever You Need

Wind Energy System.

MX1S Matrix Converter

G83/2 Engineering Recommendation

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Smaller Lighter More Powerful

Technology of Estimating Short Circuit Current and Ground Fault for Direct Current Distribution Systems

CHANGE YOUR ENERGY CHARGE YOUR LIFE

RA.Store-K. The energy of the sun also at night...

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

High Air Flow Fan San Ace 60 G Type

TECHNICAL SPECIFICATION FOR ENERGY STORAGE SYSTEM REV 6.0

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

PLUG-AND-PLAY ENERGY STORAGE SOLUTION

DEVELOPMENT AND SPREAD OF GHP WITH A POWER-GENERATING FUNCTION ( FUSION OF AIR-CONDITIONING AND POWER GENERATION)

IEEE Workshop Microgrids

8 Troubleshooting and Maintenance

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

Transcription:

New Products Introduction Development of Conditioner with a Lithium Ion SANUPS PMC-TD Tetsuya Fujimaki Akinori Matsuzaki Katsutoshi Yamanaka Naohiko Shiokawa 1. Introduction Since the Great East Japan Earthquake, there has been an increase in the number of local councils considering installing backup and demand from private industry in order to prepare for long-term outages in the event of disasters. Among this, disaster prevention photovoltaic generation systems consisting of photovoltaic batteries and storage batteries have gained attention as backup sources that use natural energy and yet can be used as stand-alone sources during a disaster. Sanyo Denki has been selling the SANUPS PMC-TD series, which is a disaster prevention photovoltaic generation system consisting of photovoltaic batteries and storage batteries, for some time now. The SANUPS PMC- TD series is highly regarded by the market and consists of a lineup with grid-connected operation and isolated operation functions, isolated operation and charging operation functions and peak-cut function. This time, we have enhanced the lineup by developing a model which incorporates a lithium ion battery on the models with isolated operation and charging operation functions and peak-cut function. Compared with conventional lead batteries, lithium ion batteries have longer life and a high energy density, therefore achieving longer life systems which are both smaller and lighter. This document provides an overview of the features of the SANUPS PMC-TD conditioner with a lithium ion battery. shows the basic circuit architecture. The conditioner unit has an isolated operation circuit and a charge circuit to the storage battery, enabling it to supply to isolated operation if the electrical utility grid goes down. The I/O has a storage battery input switch, a conditioner switch, and an isolated operation bypass switch. Switching between operation modes and turning the circuit on and off causes the supplies to switchover. Fig. 1: A photo of SANUPS PMC-TD(50 kw) 2. Overview of the SANUPS PMC-TD The SANUPS PMC-TD consists of a 10 kw conditioner unit and an I/O, and it is a build-up system that can stack up to five units. The lineup includes models with system capacities ranging from 10 to 50 kw. Fig. 1 shows the SANUPS PMC-TD (50 kw) and Fig. 2 I/O outages grid Fig. 2: Basic circuit architecture of SANUPS PMC-TD SANYO DENKI Technical Report No.36 Nov. 2013 I/O 28 outages

3. Features of the Lithium Ion Model Compared with lead batteries, lithium ion batteries have high energy density, meaning that energy can be extracted efficiently. As such, if a battery of equal capacity is equipped, lithium ion batteries make downsizing, weight-saving and space-saving possible. Moreover, the charge/discharge cycle of lithium ion batteries is long, therefore they are advantageous in applications such as isolated, charging and peak-cut operation in which charge/discharge are repeated and offer longer life than lead batteries. Fig. 3 is a photo of the lithium ion battery panel. A protection function is required for lithium ion batteries to protect the safety of the battery and system when a battery fault, such as overcharging and overdischarging, occurs. Table 1 gives an outline of the battery panel and a description of the protection function. If a battery fault is detected, the conditioner disconnects the battery to protect it. Fig. 4 shows the system configuration when a lithium ion battery is equipped. Lithium ion battery panel Auxiliary 200 V AC/2 A LiB interface PMC-TD 4. SANUPS PMC-TD Operation Mode measurement value 4-20 ma outages PCS status information/ measuring information RS-485 LiB status information/ measuring information RS-485 Monitor display unit Fig. 4: Basic configuration when lithium ion battery is equipped The SANUPS PMC-TD series has four operation modes: grid-connected operation, peak-cut operation, isolated operation and charging operation. This chapter provides an overview of the operation of each operation mode and the protection operation of each operation mode in the event that a battery fault is detected. Fig. 3: A photo of the lithium ion battery panel Item capacity (nominal) Dimensions Protection function (Outgoing signals) Table 1: Outline of battery panel 23 kwh Specifications 310.8 V W: 1100 mm D: 700 mm H: 2075 mm (including protruding objects) Overcharge Over-discharge temperature fault Cell controller failure BCU failure 4.1 Grid-connected operation mode Grid-connected operation is executed when all the following conditions are met. Fig.5 shows the flow of during grid-connected operation. generated from the s is above a certain amount grid is normal During grid-connected operation, the conditioner tracks maximum points and supplies AC to the electrical utility grid depending on the generated from the s. If the generated from the PV panels is more than the consumption of the general, the surplus is fed back to the electrical utility grid. The utility is supplied to the outages via the bypass circuit, as well as the general. If a battery fault occurs during grid-connected operation, grid-connected operation will continue. 29 SANYO DENKI Technical Report No.36 Nov. 2013

Development of Conditioner with a Lithium Ion SANUPS PMC-TD I/O outages grid I/O outages conditions are met. Fig. 6 shows the flow of during grid grid is normal 4.2 Peak-cut operation mode Peak-cut operation is executed when all the following peak-cut operation. conditioner is in grid-connected operation or I/O outages generated from the s and the battery discharge grid. I/O during The utility is supplied to the outages grid outages via the bypass circuit, as well as the general falls below the predetermined value, the conditioner Because the conditioner starts and stops peak- I/O outages cut operation while monitoring the received from grid the electrical utility grid, 10 kw the conditioner from the I/O conditioner is not fed back to the electrical utility grid outages grid during peak-cut operation. to grid-connected operation. standby received from the utility grid is greater than or equal to the predetermined value During peak-cut operation, the conditioner connects the battery to the DC input and supplies AC to the general, depending on the. When the received from the electrical utility grid disconnects the battery and automatically switches to gridconnected operation. If a battery fault is detected during peak-cut operation, the conditioner disconnects the battery and switches I/O As long as a battery fault continues during grid-connected operation, even when the necessary conditions for peak-cut are met, the conditioner does not switch to peak-cut operation. Fig. 5: Grid-connected operation mode outages grid 4.3 mode is executed when all the following conditions are met. Fig. 7 shows the flow of during isolated operation. conditioner is in operation or standby During a outage During isolated operation, after checking a continued outage for a certain period of time, the I/O outages conditioner connects the battery to the DC input and grid supplies AC to the outages with from the s and the battery. If the amount of generated from the s is greater than the supplied to the used during outages, the surplus may be used to charge the battery. If isolated operation continues due to a long outage, when the DC voltage falls below a certain value due to battery consumption, the conditioner stops I/O outages isolated operation to conserve the battery. grid During isolated operation, if a battery fault is detected when a certain amount of is generated from the PV panels, the conditioner disconnects the battery and continues isolated operation using only the generated from the s. In isolated operation, for situations where a battery fault 2 is detected during isolated operation with only the lithium ion battery as the supply (e.g. outages when the amount of generated from the s during I/O outages the day is insufficient or at night), the conditioner grid disconnects the battery and stops isolated operation. Once the battery fault recovers, the conditioner reconnects with the battery and isolated operation will be resumed using supplied by the battery. 5 6 I/O If battery faults occur and recover three times repeatedly within a 20 minute period after isolated operation is stopped, the conditioner will stop due to failure. outages grid Fig. 7: mode Fig. 6: Peak-cut operation mode I/O outages grid I/O outages SANYO DENKI Technical Report No.36 Nov. 2013 30

4.4 Charging operation mode Charging operation is executed when all the following conditions are met. Fig. 8 shows the flow of during charing operation. (1) Charging operation mode (night) conditioner is in operation or standby grid is normal Charging operation command is received from the timer in the conditioner In charging operation mode, the conditioner connects the battery to the DC input and uses the utility to charge the battery. The utility is supplied to the outages via the bypass circuit, as well as the general. During charging operation, when the charge current to the battery falls below a certain value (charging completed), the conditioner disconnects the battery from the DC input and switches to grid-connected operation mode. If a battery fault is detected during charging operation, the conditioner disconnects the battery and switches to grid-connected operation mode. (2) Charging operation mode (at the time of restoration of utility grid) Switching from isolated operation mode During isolated operation, after checking a recovery of a certain period of time, the conditioner switches to charging operation mode (standby). The utility is supplied to the I/O outages outages through the bypass circuit. grid Normally, the utility is used to charge the battery, but if a certain amount of is generated from the s, from the s may also be used. Furtheremore, if the generated from the s exceeds the charge for the battery, then the generated from the s is supplied to the general. I/O outages grid Fig. 8: Charging operation mode 4.5 Switching between each operation mode Fig. 9 shows the flow of switching between the operation modes of grid-connected, peak-cut, isolated and charging. Operation mode is normally switched automatically, but it can also be switched manually. Normal daytime Grid-connected operation used during outages Peak-cut operation used during outages Normal night Charging operation used during outages During outage used during outages Fig. 9: Switching between each operation mode 31 SANYO DENKI Technical Report No.36 Nov. 2013

Development of Conditioner with a Lithium Ion SANUPS PMC-TD 5. Specifications Table 2 shows the electrical specifications of the SANUPS PMC-TD conditioner with a lithium ion battery. Fig. 10 shows the dimensions. Table 2: Electrical specifications Item PMC100TD PMC200TD PMC300TD PMC400TD PMC500TD System capacity 10 kw 20 kw 30 kw 40 kw 50 kw Input Output input input Charge Grid-connected operation Maximum allowable input voltage Input operating voltage range 300 V DC 500 V DC 200 to 500 V DC Maximum point tracking control range V 200 to 450 V DC Max. current 45 A 90 A 135 A 180 A 225 A Fluctuation range 0 to 450 V DC Max. discharge current 45 A DC 90 A DC 135 A DC 180 A DC 225 A DC Charge capacity 8 kw 16 kw 24 kw 32 kw 40 kw Charge voltage Lead battery: 321 V DC / Lithium ion battery: 345 V DC (Setting range: 250-450 V DC Drooping start current Lead battery: 25 A DC / Lithium ion battery: 23 A DC (Setting range: 1 to 40 A DC) Per one unit 200 V AC Rated current 28.9 A AC 57.7 A AC 86.6 A AC 115.5 A AC 144.3 A AC Rated frequency 50 Hz / 60 Hz No. of phases/wires Three phase, three wire Output current distortion rate 5% or less of the total current, 3% or less of each next harmonic wave Output factor 0.95 or higher 200 V AC Rated current 28.9 A AC 57.7 A AC 86.6 A AC 115.5 A AC 144.3 A AC Rated frequency 50 Hz / 60 Hz No. of phases/wires Three phase, three wire Voltage precision Rating: Within 8% Frequency precision Rating: Within 0.1 Hz Voltage distortion rate 5% max. Output factor 1.0 to 0.8 (Lag) Conversion efficiency 92% protection function Over-voltage (OV), under-voltage (UV), over-frequency (OF), under-frequency (UF) Islanding operation Passive method Voltage phase jump method detection Active method Reactive conversions method Communication method RS-485 Acoustic noise 60 db or less Ambient temperature -10 to +50 C Operation environment Relative humidity 30 to 90% (non-condensing) Altitude 2000 m or lower Coating color Munsell 5Y 7/1 Heat generation 870 W 1740 W 2610 W 3480 W 4350 W Operation mode Grid-connected operation, isolated operation, charging operation, peak-cut operation measurement function Yes, 4 to 20 ma SANYO DENKI Technical Report No.36 Nov. 2013 32

Development of Conditioner with a Lithium Ion SANUPS PMC-TD 10 kw 580 600 1185 750 125 160 kg 20 kw 40 kw 50 kw 580 600 600 580 600 580 1485 125 750 600 600 240 kg Tetsuya Fujimaki Joined Sanyo Denki in 2011. Systems Division, 1st Design Dept. Worked on the development and design of photovoltaic systems. Akinori Matsuzaki Joined Sanyo Denki in 1981. Systems Division, 1st Design Dept. Worked on the development and design of photovoltaic systems. 30 kw 580 1485 750 125 900 600 300 460 kg 1785 125 750 560 kg Katsutoshi Yamanaka Joined Sanyo Denki in 1996. Systems Division, 1st Design Dept. Worked on the development and design of photovoltaic systems. 1785 750 125 390 kg Fig. 10: Dimensions of SANUPS PMC-TD Naohiko Shiokawa Joined Sanyo Denki in 1989. Systems Division, 3rd Design Dept. Worked on the development and design of supplies. 6. Conclusion This document introduced an overview and the features of the SANUPS PMC-TD conditioner with a lithium ion battery. This, in addition to being environmentally-friendly through effective utilization of natural energy, also provides emergency during disasters by incorporating a battery, and contributes to the improvement of electrical operability by reducing peak. This time, in addition to the conventional lead battery, we have added a model featuring a lithium ion battery to our lineup to enable overall systems to be smaller and have longer life. If users select the type of battery to suit their specific applications, we anticipate that the conditioner will play a significant role in even more markets. Sanyo Denki will continue to realize various functions demanded of conditioners and meet customer expectations. 33 SANYO DENKI Technical Report No.36 Nov. 2013