Proud To Be Manufactured- IN THE UK

Similar documents
57 KW / 71 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

70 KW / 90 KVA POWERED by

300 KW / 375 KVA POWERED by

55 KW / 70 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

TPD2250H6.3 TECHNICAL DATA

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

130 KW / 165 KVA POWERED by

18 KW / 18 KVA POWERED by

204 KW / 254 KVA POWERED by

64 KW / 80 KVA POWERED by

28 KW / 28 KVA POWERED by

30 KW / 40 KVA POWERED by

600 KW / 750 KVA POWERED by

130 KW / 165 KVA POWERED by

500 KW / 625 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

2000 KW / 2500 KVA POWERED by

60 KW / 75 KVA POWERED by

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

Rating Definitions and Conditions

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Rating Definitions and Conditions

80 KW / 100 KVA POWERED by

Rating Definitions and Conditions

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

640 KW / 800 KVA POWERED by

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

1000 KW / 1250 KVA POWERED by

Standby Amper VOLTAGE

1800 KW / 2250 KVA POWERED by

16 KW / 20 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

13,000 Watt Diesel Generator AGi13P E

WPS20/S EP Series. Features:

Model NA 2 L

Model MP150 W W

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

700 KVA / 550 KW POWERED by

Rating Definitions and Conditions

10,000 Watt Diesel Generator AGi9P E

45 KW / 55 KVA POWERED by

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Diesel Generating Set

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

20 KW / 25 KVA LIQUID COOLED POWERED by

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Rating Definitions and Conditions

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

WPS60/S EP Series. Features:

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

55 KW / 69 KVA POWERED by

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

APD-ULJ250. Standby Power

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

19 KW / 24 KVA POWERED by

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

Standby Amper VOLTAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Technical specification

8,000 Watt Diesel Generator

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

UK MANUFACTURED GENERATORS PS100P PS150P PERKINS 1006 SERIES TECHNICAL DATA SHEET

GMS350C/S EC Series. Features:

CGT Stamford UCI 274 E1

GMS200C/S EC Series. Features:

Transcription:

Proud To Be Manufactured- IN THE UK AP30/S-AP60/S, Three Phase, 30-60 kva AP21/S-AP40/S, Single Phase, 21-40 kva Generator Ratings (Prime/Standby) Prime Power Standby Power KVA KW KVA KW AP30/S 30 24 33 26.4 AP45/S 45 36 49.5 39.6 AP60/S 60 48 66 52.8 AP21/S 21 16.8 23.1 18 AP28/S 28 22.4 3 24.6 AP40/S 40 32 44 35.2 RPM Power Factor MODEL NUMBER EXAMPLE: AP9 OPEN TYPE & AP9S SOUNDPROOFED AP - 'Alpha Series with Perkins Engine'

SOUNDPROOFED CANOPY & BASE FRAME QUALITY MATERIALS & WORKMANSHIP Galvanised steel canopy & base frame Galvanised fixings Powder coating base & canopy Multi-density polyester soundproofing material - Fire resistant Class 1 Canalised air-flow intake outlets equipped with water & sand traps Lift hooks/forklift space strong enough to support whole genset. Large base fuel tanks to support long running Residential exhaust muffler mounted inside canopy - Noise reduction of 38db (A) Residual noise level of 65db (A) at 7m (Soundproofed) ACCESS & MAINTAINANCE Large doors for easy servicing Removable doors Radiator filling point (UK Standard) Colour coded wiring looms Measure perameters via DSE control modules SAFETY, SECURITY & TRANSPORTATION High quality door locks with keys included Residential exhaust muffler mounted inside canopy Warning & hazard labels Operation manuals included Battery isolation switch included Emergency stop fitted Compact maximize container space Test & Pre delivery inspection Carefully packaged for delivery UK & EU COMPONENTS Reliable EU batteries European main circuit breakers Deep Sea Electronics 3000 & 4000 series control modules CPS Manufactured wiring looms and control boxes External fuel gauge & emergency stop Deep Sea Electronics battery charger (optional) Wired for cold weather start (UK Standard) Dimensions & Weights Canopied Dimensions Open Type Dimensions Length Width Height Weight KG Length Width Height Weight KG AP30/S 2200 900 1330 1100 1550 750 1310 800 AP45/S 2200 900 1330 1350 1640 750 1420 1000 AP60S 2200 900 1330 1350 1640 750 1420 1000 AP21/S 2200 900 1330 1100 1550 750 1310 800 AP28/S 2200 900 1330 1100 1640 750 1420 1000 AP40/S 2200 900 1330 1350 1640 750 1420 1000

Fuel Consumption & Sound Levels Tank L Fuel Consumption (L/Hour) Soundproofed Canopy dba Ratings (75%) 110% 100% 75% 7M 1M AP30/S 100 8.1 7.2 5.61 AP45/S 100 11.7 1 8.23 AP60S 100 15.9 14.6 1 AP21/S 100 8.1 7.2 5.61 65 74 AP28/S 100 8.1 7.2 5.61 AP40/S 100 11.7 1 8.23 Engine Technical Data Engine Brand Engine Induction Cooling Governor Type Compressi on Ratio Oil Capacity Displacement AP30/S Perkins 1103A-33G 19.25:1 3.3 8.3 Naturally Water- AP45/S Perkins 1103A-33TG1 Mechanical 17.25:1 3.3 8.3 Aspirated Cooled AP60S Perkins 1103A-33TG2 17.25:1 3.3 8.3 AP21/S Perkins 1103A-33G 19.25:1 3.3 8.3 Naturally Water- AP28/S Perkins 1103A-33G Mechanical 19.25:1 3.3 8.3 Aspirated Cooled AP40/S Perkins 1103A-33TG1 17.25:1 3.3 8.3 *D emissions engine can be supplied Alternator Technical Data MeccAlte Bearings Winding Pitch Wires Bearings Stamford Winding Pitch AP30/S ECP28-VL/4 1 2/3 12 PI144G 1 2/3 12 AP45/S ECP32-1L/4 1 2/3 12 UC224D 1 2/3 12 AP60S ECO32-2L/4 1 2/3 12 UC224E 1 2/3 12 AP21/S ECP32-2S/4 1 2/3 12 PI144G 1 2/3 12 AP28/S ECP32-1L/4 1 2/3 12 PI144K 1 2/3 12 AP40/S ECP34-3L/4 1 2/3 12 UC224D 1 2/3 12 Wires Whilst we will endeavor to ensure all of our specification is correct, inline with our policy of developing and improving our product range we reserve the right to change specification without notice.

Auto Start/ Manual Control Panel (Standard) DEEP SEA ELECTRONICS Deep Sea Electronics is one of the world s top manufacturers of generator control, auto transfer switch and battery charger equipment. DSE3110 MANUAL/ AUTO START CONTROL MODULE The DSE3110 is an outstanding compact control module that provides a comprehensive range of features for single-set applications. The controller can be used in manual or auto start mode. Easy operation, push button start Large back-lit icon LCD display Configurable timers & alarms Engine pre-heat Remote start input Standard engine and electronic CANbus variants. Works with DSE Configuration Suite PC Software DSE4620 AUTO MAINS FAILURE CONTROL MODULE (OPTIONAL) The DSE4620 is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure. Easy operation Large back-lit icon based display 3-phase generator sensing Generator & load power monitoring (kw, kv A, kv Ar, pf) Generator overload protection (kw) Configurable inputs & outputs Fuel and start outputs Fuel & crank outputs Magnetic pick-up speed sensing Engine speed protection, engine hours counter, engine pre-heat, engine runtime scheduler, engine idle control for start/stop Battery voltage monitoring Deep Sea Electronics control modules have a wide range of advanced features, expansion boards and configuration options to suit the most demanding applications. Meaning we can offer you a huge range of accessories and a product to suit your needs.

OPTIONAL ACCESSORIES OPERATION: Automatic Transfer Switches Manual Transfer Switches Automatic Fuel Transfer External Plug Sockets SERVICE & MAINTAINANCE Minor & Major Service Parts Service Contracts (UK Customers) CONTROL: GSM Modem Remote Control Start FURTHER OPTIONS: *Fuel Tanks - External / Large / Underground *Be-Spoke Canopies (Including Colour) *Slow/Fast Trailer & Many More www.ecopowersupplies.com