LED BUILT-IN MODULES LUGA SHOP 2015 PCB PEARL WHITE LUGA SHOP 2015 PCB PEARL WHITE LED MODULES COB FOR RETAIL ENVIRONMENTS DMS099S31FP / DMS120S31FP / DMS150*31FP Typical Applications Integration in reflector luminaires Shop lighting, especially fashion lighting BRILLIANT WHITE LIGHT OPTIMIZED FOR FASHION AND CLOTHES LIGHTING SIMILAR COLOUR IMPRESSION LIKE CMH LAMPS LONG SERVICE LIFETIME: 50,000 HOURS (L90; B10) HIGHLY EFFICIENT: UP TO 131 LM/W AT t p =65 C NARROW COLOUR TOLERANCES: 3 STEP MACADAM (INITIAL) 4 STEP MACADAM SHIFT (AFTER 50,000 HRS) HIGH ELECTRICAL ISOLATION DUE TO CERAMIC COB TECHNOLOGY THREE LIGHT EMITTING SURFACE (LES) SIZES LES14, LES17, LES20 Vossloh-Schwabe Deutschland GmbH Hohe Steinert 8 509 Lüdenscheid Germany Phone +49 23 51/10 10 Fax +49 23 51/10 12 17 www.vossloh-schwabe.com
Technical Notes LED built-in module for integration into luminaires Dimensions: 19x19 mm, 28x28 mm Light emitting surface (LES): 14 mm, 17 mm, 20 mm Use of external LED constant current driver Electrical Characteristics Type Ref. No. Typ. voltage DC Temperature Typ. power consumption 350 ma 500 ma 700 ma 1050 ma 1400 ma coefficient 350 ma 500 ma 700 ma 1050 ma 1400 ma V V V V V mv/k W W W W W DMS099S31FP All types 24.7 25.3 25.8 26.7 27.3 13 8.7 12.6 18.1 28 38.1 DMS120S31FP All types 32.9 33.4 34.1 35.3 36 18 11.5 16.7 23.9 37 50.4 DMS150*31FP All types 41.1 41.8 42.7 44.2 45 22 14.4 20.9 29.9 46.4 63 Voltage and power tolerance: ±10 % Maximum Ratings Exceeding the maximum ratings can lead to reduction of service life or destruction of the modules. Type Operating Operation temperature Ambient temperature Storage temperature Max. allowed repetitive current range at t c point range range peak current ma C min. C max. C min. C max. C min. C max. ma DMS099S31FP 700 40 +105 40 +40 40 +105 1620 1050 +97 1400 +83 DMS120S31FP 700 40 +105 40 +40 40 +105 1670 1050 + 1400 +81 DMS150*31FP 700 40 +105 40 +40 40 +105 1670 1050 +100 1400 +88 Optical Characteristics Type Ref. No. Colour Correlated colour Typ. luminous flux** and efficiency at Typ. Typ. Phototemperature* 350 ma 500 ma 700 ma 1050 ma 1400 ma beam CRI metric K lm lm/w lm lm/w lm lm/w lm lm/w lm lm/w angle ( ) R a code DMS099S31FP 558233 pearl white 3100 1070 123 1500 119 2015 111 2825 101 34 92 120 931/349 DMS120S31FP 558236 pearl white 3100 1480 129 2040 122 2745 115 30 104 4745 94 120 931/349 DMS150S31FP 558240 pearl white 3100 1890 131 2625 126 3540 118 49 107 6180 98 120 931/349 DMS150C31FP 561128 pearl white 3100 2225 155 30 148 4160 139 5860 126 7260 115 120 831/349 *Colour tolerance: 3 MacAdam ** Production tolerance of luminous flux and efficiency: ± 10 %; luminous flux values can vary depending on the respective PCB holder system. Min. CRI R a : > 90 / > 80 Minimum order quantity: 175 pcs. (DMS099); 100 pcs. (DMS120/DMS150) LUGA Shop 2015_PCB_Pearl-White_GB 2/5 January, 2016 Operating Life Lumen DMS099S31FP (at I F ) DMS120S31FP (at I F ) DMS150*31FP (at I F ) mainte- 350 ma 500 ma 700 ma 1050 ma 1400 ma 350 ma 500 ma 700 ma 1050 ma 1400 ma 350 ma 500 ma 700 ma 1050 ma 1400 ma nance in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours in hours L90/B10 62,000 59,000 53,000 42,000 28,000 62,000 58,000 52,000 40,000 26,000 63,000 60,000 55,000 45,000 33,000 L80/B10 87,000 84,000 78,000 67,000 53,000 87,000 83,000 77,000 65,000 51,000 88,000,000 80,000 70,000 58,000 L70/B10 97,000 94,000 88,000 77,000 63,000 97,000 93,000 87,000 75,000 61,000 98,000,000 90,000 80,000 68,000 The specified service life is based on the assumption that the module will exert a surface contact pressure of 10 N and that an optimal thermal connection will be ensured between the entire module and an aluminium heat sink. Vossloh-Schwabe Deutschland GmbH Hohe Steinert 8 509 Lüdenscheid Germany Phone +49 23 51/10 10 Fax +49 23 51/10 12 17 www.vossloh-schwabe.com 2
Typical Light Distribution Curve I (cd/klm) 90 60 170 255 340 30 Mechanical Dimensions The clearance and creepage distances are designed for working voltages up to: Type Basic insulation Reinforced insulation DMS099***F 235 V DC 60 V DC DMS120***F/150***F 330 V DC 175 V DC Thickness of PCB is included in calculation. DMS099S31FP DMS120S31FP DMS150*31FP LESØ14 19.0±0.3 LESØ17 4.3±0.3 LESØ20 3.3±0.3 16.6±0.3 2.0±0.3 4.0±0.3 0.8±0.3 0.8±0.3 15.0±0.3 Ø16.4 19.0±0.3 25.0±0.3 Ø19.4 19.6±0.3 25.0±0.3 Ø22.4 20.2±0.3 Product Code Bins LUGA Shop 2015_PCB_Pearl-White_GB 3/5 January, 2016 CCT 2700K 3000K 3000K* 3500K 3500K* 4000K 4000K* 5000K 5000K 2700K* 3000K* 3100K** 3500K* 4000K* CRI No. DMS099 DMS120 DMS150 82 70 * below BBL ** Pearl White 99C27F 20C27F 50C27F 99C30F 20C30F 50C30F 99C30f 20C30f 50C30f 99C35F 20C35F 50C35F 99C35f 20C35f 50C35f 99C40F 20C40F 50C40F 99C40f 20C40f 50C40f 99C50F 20C50F 50C50F 99B50F 20B50F 50B50F 99S27F 20S27F 50S27F 99S30F 20S30F 50S30F 99S31F 20S31F 50S31F 99S35F 20S35F 50S35F 99S40F 20S40F 50S40F Measurement tolerance x/y: ± 0.005 Vossloh-Schwabe Deutschland GmbH Hohe Steinert 8 509 Lüdenscheid Germany Phone +49 23 51/10 10 Fax +49 23 51/10 12 17 www.vossloh-schwabe.com 3
Assembly and Safety Information Installation must be carried out under observation of the relevant regulations and standards. The LED modules are designed for operation within a casing or luminaire. Installation must be carried out in a voltage-free state (i.e. disconnection from the mains). The following advice must be observed; non-observance can result in the destruction of the LED assembly modules, fire and/or other hazards. ESD (electrostatic discharge) protection measures must be observed when handling and installing the LED modules. See VS's application notes on ESD protection. LED assembly modules must not be subjected to any undue mechanical stress, e. g.: do not treat as bulk cargo avoid shear and compressive forces during handling and installation do not damage circuit paths do not touch the yellow phosphorus layer The module must be fixed onto a thermally conductive surface. The electrical connection of the modules must be done with separate holder systems. Direct soldering of cables at the contact pads is not allowed. Safe operation only possible by the use of external constant current sources (I max. see table "Electrical Characteristics"). Operation only with power supply units that feature the following protection: Short-circuit protection Overload protection Overheating protection SELV (Safety Extra Low Voltage); U max. 60 V I max. (see table "Maximum Ratings") must not be exceeded. When operating devices will be selected care has been taken to ensure that the maximum values (see table "Maximum Ratings") will not be exceeded. Please ensure the correct polarity of the leads prior to commissioning. Reversed polarity can destroy the modules. Safety regulations acc. to EN 60598 (or further standards) has to be observed if the maximum output voltage exceed the permitted touchable value. Measurement tolerances: luminous flux: ± 7 % voltage: ± 3 % CRI: ± 1 % A parallel connection of the modules is not allowed. To ensure problem-free operation, the specified maximum temperature at the t c point (see "Operating Life") must be observed (and measured in accordance with EN 60598-1). To satisfy this point, it may be necessary to put measures in place to ensure any heat is dissipated from the PCB to the environment. In the event of outdoor applications or applications in damp locations, care must be taken to protect LED assembly modules against humidity, splashes and jets of water. Any corrosion damage resulting from humidity or contact with condensation will not be recognised as a defect or manufacturing fault. LED assembly modules are not specially protected against foreign bodies or dust. Depending on the type of application, further protection must be ensured to prevent dust and foreign bodies from entering. Operating LED modules in the presence of certain chemical substances or in chemically enriched (aggressive) environments can impair module functionality or even cause total module failure. Detailed information can be found in our "Chemical Incompatibility" PDF on our website www.vossloh-schwabe.com/en/home/ products/led-lighting-technology/notes-on-led-technology.html The photobiological safety of the LED modules must be classified into risk groups in accordance with EN 62471: 2008. Assessment of risk groups in acc. with IEC/TR 62778: risk group 1 LUGA Shop 2015_PCB_Pearl-White_GB 4/5 January, 2016 Vossloh-Schwabe Deutschland GmbH Hohe Steinert 8 509 Lüdenscheid Germany Phone +49 23 51/10 10 Fax +49 23 51/10 12 17 www.vossloh-schwabe.com 4
Reflectors: ACL-Lichttechnik GmbH www.reflektor.com Jordan Luxar GmbH & Co. KG www.jordan-luxar.de JORDAN REFLEKTOREN GmbH & Co. KG www.jordan-reflektoren.de LEDIL www.ledil.com Heat sinks with active cooling: AVC www.avc-europa.de Nuventix, Inc. www.nuventix.com Sunon www.sunon.com MechaTronix www.led-heatsink.com Colliance, Inc. www.cooliance.eu Heat sinks with passive cooling: AVC www.avc-europa.de Fischer Elektronik GmbH & Co. KG www.fischerelektronik.de Frigo Dynamics www.frigodynamics.com MechaTronix www.led-heatsink.com LED Constant Current Drivers Please visit our homepage for details for suitable LED constant current drivers: www.vossloh-schwabe.com/en/home/products/ components-for-led-lighting-technology/ led-control-gears/constant-current.html LUGA Shop 2015_PCB_Pearl-White_GB 5/5 January, 2016 Vossloh-Schwabe Deutschland GmbH Hohe Steinert 8 509 Lüdenscheid Germany Phone +49 23 51/10 10 Fax +49 23 51/10 12 17 www.vossloh-schwabe.com 5