Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Similar documents
Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Solid Dielectric, Single Phase Recloser

Solid Dielectric, Single Phase Reclosers

solutions RUS accepted

Cobra-S. Catalog Cobra-S

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Solid Dielectric, Three Phase Reclosers CATALOG VS11

RUS accepted Catalog O-vst18

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Padmount Solid Dielectric Switchgear Catalog

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Typical Specification

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Three-Phase Pole Mounted Recloser

Product Group Brochure. PS Range Capacitor Vacuum Switches

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Horizontal Circuit Switchers

PRODUCT SELECTION GUIDE

Submersible Vacuum Fault Interrupters

Underground Distribution Switchgear

C1000 Series Automatic Cap Bank

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

CATALOG. Joslyn Hi-Voltage Overhead reclosers & switches

Horizontal Circuit Switchers

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Publication No.: PSG

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Transmission Switching

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Underground Distribution Switchgear

ELASTIMOLD MOLDED VACUUM SWITCHGEAR

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

B kv T&D GAS INSULATED SWITCHGEAR

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Transmission Switching

NOVA three-phase, microprocessorcontrolled

SF 6 Gas Insulated Load Break Switch

COOPER POWER CA280012EN

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

CATALOG. Elastimold Reclosers, switches and switchgear

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

SWITCHGEAR DIVISION PRODUCT PROFILES

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

KFE10002-E. Reclosers. Type KFE and KFVE Electronically Controlled Vacuum Recloser Installation Instructions. Service Information

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

EE 741 Over-voltage and Overcurrent. Spring 2014

NOVA NX-T Triple-Single, Microprocessor-Controlled Recloser

Advance 27 ANSI 27 kv switchgear

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

your Green Power WIND POWER SOLUTIONS only Greener

B kv Gas-insulated Substations

Power Break II Switchboard

Medium Voltage Metal-Enclosed Switches

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Single-Phase Step Voltage Regulators

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Fisher Pierce. Cable Accessories. Faulted Circuit Indicators. Series 1548 Overhead FCIs

Underground Distribution Switchgear

Medium voltage vacuum circuit breaker. E-VAC series

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Outdoor vacuum breaker for railway applications - FSK II

Q pole Pole Mounted Capacitor System

Medium Voltage Outdoor Apparatus Portfolio 2009

Elastimold & Hi-Tech Fuse Products

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

GROUP D. Switch & Protective device.

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

Molded Current-Limiting Fuse

Application Engineering

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Underground Distribution Switchgear

Type SDV7 distribution circuit breaker family

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

INSTALLATION PRODUCTION TESTS

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

University of Houston Master Construction Specifications Insert Project Name

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Transcription:

Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A or 800A continuous current, 12.5 or 16kA symmetrical interrupting Interrupting rating of 12.5 ka or 16kA Reliable performance Operator safety including mechanical block on trip and lockout handle Maintenance-free operation Overhead and substation mount designs Easy to install Three internal current transformers Integral voltage sensing Compact design Smart Grid/Lazer solutions Works directly with SEL-651R controls and Beckwith M-7679 controls RUS accepted Catalog O-vlt14

Viper-LT Viper -LT solid dielectric triple option recloser combines the time-proven reliability of electronically controlled, vacuum fault interrupters with the maintenance-free benefits of a solid dielectric insulated device. The Viper-LT provides overcurrent protection for systems through 27kV maximum, through 800A continuous current and 12.5kA or 16kA symmetrical interrupting. Features Reliable Performance - Viper-LT reclosers utilize a time-proven cycloaliphatic epoxy system to fully encapsulate the vacuum interrupters. All modules are UV resistant and 100% factory tested for partial discharge. The Viper-LT recloser utilizes the latest in magnetic actuator technology. The interrupter and actuator assembly have been tested for over 10,000 mechanical operations to assure a long operating life. Operator Safety - A hookstick operable, manual trip and lockout handle prohibits operation either from the control or remotely. A mechanical blocking device further ensures against accidental close from a remote close signal or the control. An open and closed contact indicator verifies contact position. Contact status and lockout condition can also be verified at the control. Maintenance-free - Solid dielectric insulation provides a maintenance-free installation. Electronic equipment associated with the operation of the magnetic actuator(s) is located in the control. The contact wear of the Viper-LT can be monitored through the control. Ease of Operation - The Viper-LT is directly compatible with the SEL-651R or Beckwith M-7679 control for a single phase operation and lockout. Electronically ganged three phase operations can be performed with the VRC/Falcon or VRC/SEL-751A combination. Ease of Installation - The Viper-LT is lightweight and compact. (Approximate weight is 300 lbs or 136 kg).the optional site-ready designs provide all accessories including bracket, arresters, Accusense voltage sensors, and voltage transformers preassembled prior to shipment significantly reducing installation time. One single control cable brings all current, breaker status and trip/close information into the control. Smart Grid/ Lazer Automation Solutions - The Viper-LT is automation ready, simplifying conversion for any future automation requirements. Multi-ratio Current Transformers with a 1000/500:1 ratio are encapsulated inside the horizontal bushings. Other lower CT ratios can be used for low current detection such as Sensitive Earth Fault. Two different CTs are available for these applications, either a 500/400/300:1 or a 150/100/50:1. The default ratio is factory set at the highest available ratio unless otherwise requested. Ratios at the Viper and the control settings are field changeable. The CTs have a current amplitude accuracy of +/-1%. Capacitive style voltage sensors encapsulated within each module permit analog voltage monitoring for network reconfiguration. Voltage sensing amplitude accuracy is +/- 2% when tested as a system from -10 C (14 F) to +50 C (122 F). The voltage sensor accuracy is -4% to +3% from -40 C (-40 F) to +65 C (149 F). The phase angle accuracy is +/-1 throughout the full temperature range. External, high accuracy Accusense voltage sensors can also Vacuum Interrupter Drive Assembly Voltage Sensor / Current Transformer Magnetic Actuator p Manual trip handle prohibits electronic closing operation through the control and features mechanical and electrical block providing the utmost in safety. Manual Trip Handle Position Indication t 27kV, 16kA Viper-LT recloser with polemount center bracket G&W ELECTRIC PAGE 2

be used depending on application requirements. Complete Lazer automation packages are available offering a pre-engineered solution for applications requiring intelligent automatic switching and power restoration. Automated packages feature one or more protective relays equipped with all communication and logic accessories for a plug and play system that can be quickly implemented. Dead-Line Operation The unique design of the Viper-LT magnetic actuator system provides for local and remote operation of the recloser in the event that the AC source power is lost or interrupted. Dead-Line operation allows the unit to operate through the batteries located in the control. Control Capabilities The Viper-LT comes with two different control options: 1. The Viper Recloser Control (VRC) paired with a SEL-351R4, SEL-351R3 Falcon, SEL-751A, or GE DGCR; for three phase electronically ganged operations. 2. The SEL-651R or Beckwith M-7679 controls permits three distinct mechanical operating modes. 1 Ø trip / 1 Ø lockout 1 Ø trip / 3 Ø lockout 3 Ø trip / 3 Ø lockout Operation Principle The Viper-LT recloser monitors the circuit using internal multi-ratio current transformers and voltage sensors. The control is powered by an external 120 VAC or 125 VDC source. The Viper-LT is powered directly from the control, with no other external power required. Recloser sequence operations, tripping and overcurrent sensing is an automatic function of the electronic control. Each phase module incorporates a magnetic actuator and drive assembly. Each magnetic actuator uses a permanent magnet to hold a solenoid plunger in the closed position while maintaining a charge on the opening spring. Trip/close operation is simply accomplished by energizing the trip coil which generates a magnetic flux in the opposite direction and releases the trip spring. Manual Trip Operation Operation of the hookstick operable manual trip handle trips and locks out the recloser. Pulling the handle down trips and locks out the selected phase. A contact position indicator is provided indicating open or closed status of the contacts for each phase. Module contact status is also displayed at the control. Operation of the manual trip handle disables any local or remote closing operation until the handle is reset. A mechanical blocking device further ensures against accidental close from a remote close signal or the control. The handle is operable from ground level. Once reset, the recloser can be closed using the control. Catalog Numbers Voltage Class 15.5kV; 630A; 12.5kA 27kV; 630A; 12.5kA 15.5kV; 800A; 16kA 27kV; 800A; 16kA Catalog Number VIP376ER-12-[1 or 3]*-LT VIP386ER-12-[1 or 3]*-LT VIP378ER-16-[1 or 3]*-LT VIP388ER-16-[1 or 3]*-LT * 1= SEL-651R or 3= VRC/Falcon or VRC/SEL-751A p Viper Recloser Control (VRC) with SEL-351R3 Falcon relay. Control Connections For either control, a twist lock style 32-pin connector makes the cable connection between the control and the interrupter control box. The cable provides the normal power supply to the magnetic actuator. The 32-pin interface control cable also brings down the CT and VS outputs to the control. A standard 52a auxiliary contact for each phase comes with the 32-pin Amphenol connector. As an option, a 42- pin interface with a Harting connector is provided when an additional 52b auxiliary contact is requested. Both 52a and 52b are on the same Form C micro-switch. This 42-pin interface also offers a cable-disconnected alarm when the cable is unplugged or cut. Accusense Voltage Sensors Accusense voltage sensors are a metering-class voltage sensing solution that enables users to collect critical voltage data needed for optimizing grid power delivery and reliability. This technology eliminates the need for traditional metering class voltage transformers and is available to be paired with the Viper-LT as a site-ready solution. Accusense voltage sensors have been tested to IEC 60044-7, IEEE C37.60-2012 and IEEE C37.90-2005 and comply with accuracy class 0.5 (±0.5% Magnitude, ±0.344 Phase). They are rated to operate up to 27kV system voltages, 125kV BIL, -40 C to + 65 C temperature range, and output Low Energy Analog (LEA) signals (max 8VAC). G&W ELECTRIC PAGE 3

Viper-LT Polemount Center Frame* 15 (381mm) 15 (381mm) 33" (830mm) 43 (1102mm) 49 (1241mm) p Optional 3-phase ganged manual trip handle. Polemount Center Frame (with one PT and provisions up to four PTs)* 67 (1689mm) 62 (1565mm) 24 (610mm) 24 (610mm) 41 (1054mm) G&W ELECTRIC PAGE 4 * Dimensions are approximate. Do not use for construction. Brackets are aluminum as standard.

Single Polemount Frame* 23" (595mm) 35" (878mm) 18" (445mm) 43 (1102mm) Cluster Polemount Frame* 43" (1102mm) 54" (1371mm) 99" (2539mm) 45 Substation Frame (with front control mount) 45 or 90 installations Side or front control mount Galvanized steel frame is standard. Dimensions are approximate. Do not use for construction. 15 (381mm) 15 (381mm) Adjustable frame in 3" increments 127 (3223mm) 138 (3505mm) Maximum 102 (2591mm) Minimum 54 (1371mm) * Dimensions are approximate. Do not use for construction. 45 (1164mm) 28 609mm) G&W ELECTRIC PAGE 5

Typical Specifications A. GENERAL This specification covers the requirements for an electronically controlled, solid dielectric vacuum recloser with Triple Option trip/close capabilities for use on distribution systems through 27kV and an interrupting current of 12.5 or 16kA. The recloser shall be manufactured by G&W Electric Company designated as Viper-LT solid dielectric recloser. Recloser configuration shall be either polemount center, cluster, or substation frames. B. DESIGN RATINGS AND STANDARDS Reclosers shall be designed, tested, and built per IEEE C37.60 and IEC 62271-111 standards, latest version. Certified test reports shall be provided. The recloser shall be rated: Max System Voltage (kv) Interrupting Rating RMS (ka) 15.5 27 12.5 16 12.5 16 Rated Voltage (kv) 15 15 25 25 BIL (kv) 110 110 125 125 Continuous Current (A) 630 800 630 800 8 Hr. Overload, at 20 C 800 960 800 960 Making Current, RMS, asym, (ka) 20 25 20 25 Peak, asym (ka) 32 42 32 42 Short Circuit Current, (ka) sym, 3 second 60Hz Withstand, (kv) rms dry, 1 min 60Hz Withstand, (kv) rms wet, 10 sec Mechanical Operations (open - close) 12.5 16 12.5 16 50 50 60 60 45 45 50 50 10k 10k 10k 10k Frequency, Hz 50/60 50/60 C. RECLOSER CONSTRUCTION C1: Mechanism Enclosure The magnetic actuator and corresponding linkage assembly shall be housed within a high impact, UV stable, air insulated, poly-carbonate enclosure. A contact position indicator and air vent shall be provided. Lifting provisions shall be provided. C2. Operating Mechanism The operating mechanism shall utilize a magnetic actuator for opening and closing of the vacuum interrupters. The magnetic actuator must include a trip spring to ensure the recloser will fully open 100% of the time. Likewise, the trip spring will maintain the recloser on the open position if it can not perform a full close operation. The magnetic actuator shall be powered by capacitors located in the control enclosure. A mechanical block shall be provided to prevent accidental close signals to operate the recloser when the trip and lock out handle is engaged. The manual trip and lockout handle shall be made of aluminum for maximum corrosion resistance. Vacuum interrupter contact position indication shall be accomplished using green (open) and red (closed) indicators located on the bottom of each mechanism enclosure and through LEDs inside the control. C3. Vacuum Interrupters Interruption of the fault or load current shall be accomplished through vacuum interrupters located inside the solid dielectric modules. C4. Solid Dielectric Modules The solid dielectric modules shall utilize a time-proven cycloaliphatic epoxy insulation to fully encapsulate each of the three vacuum interrupters. The operating temperature range shall be -40 C to +65 C. A dual ratio, 500:1 and 1000:1, current transformer and voltage sensor shall be integrally molded into each module. CT accuracy shall be +/-1%. Other ratios for low current detection such as 500/400/300:1 or 150/100/50:1 shall be available. D. OPERATION Monitoring of the circuit shall be accomplished using internal multi-ratio current transformers and voltage sensors. The unit shall be powered by an external 120 VAC or 125 VDC source. In the event AC power is lost, the unit shall have trip/close operating capabilities through the batteries located in the control. Recloser sequencing, tripping and overcurrent sensing, shall be an automatic function of the electronic control. If the control is set for single phase trip/lockout, the control will trip only the affected phase and not disturb the other two phases. If set for single phase trip, three phase lockout, only the affected phase will trip, and if the fault is not cleared, all three phases will lockout. If set for three phase trip, a fault current on any phase will trip all three phases. Manual trip and lockout shall be provided by an external, hookstick operable handle. Operation of the manual trip handle shall activate a mechanical block device, disabling any local or remote closing operation until the handle is reset. G&W ELECTRIC PAGE 6 Visit gwelec.com/specs.html for electronic versions of typical specifications.

E. SMART GRID / LAZER AUTOMATION The recloser shall be automation ready simplifying conversion for any future automation requirements. Capacitive voltage sensors shall be encapsulated within each recloser module permitting voltage reading for network reconfiguration. Voltage sensing amplitude accuracy is +/- 2 % when tested as a system from -10 C (14 F) to +50 C (122 F). The voltage sensor accuracy is -4% to +3% from -40 C (-40 F) to +65 C (149 F). The phase angle accuracy is +/-1 throughout the full temperature range. The recloser shall have an option for external voltage sensors with 0.5 accuracy class (±0.5% Magnitude, ±0.344 Phase) at -40 C to + 65 C temperature range. These external voltage sensors shall have a 5000:1 ratio and Low Energy Analog (LEA) outputs. Integrated communication devices can be provided. F. MOUNTING Lifting provisions shall be provided. Mounting provisions shall be supplied as follows with arrester provisions on the load and source side: Aluminum polemount center bracket Galvanized steel substation frame Aluminum cluster polemount H. ELECTRONIC CONTROLS The recloser shall be controlled using the SEL-651R or Beckwith M-7679 control for triple option, or the G&W Viper Recloser Control with Falcon for three phase operations only. One control cable interface shall be used between the control and the recloser. K. OPTIONS The following options shall be supplied: (Check as necessary) NEMA 2-hole aerial lugs NEMA 4-hole aerial lugs Clamp style aerial lugs (#2-750 kcmil) 4/0 brass eyebolt ground lug Galvanized polemount center bracket with arrester provisions on the load and source side. Stainless steel polemount center bracket with arrester provisions on the load and source side. Polemount site-ready assembly Lightning arresters External 1.0 KVA oil transformer (3% accuracy) for 120 VAC supply power with hardware to mount on 24" phase spacing aluminum frame External 0.75 KVA solid dielectric voltage transformer (0.3% accuracy) for 120 VAC supply power with hardware to mount on standard aluminum frame External Accusense Voltage Sensors (0.5 class accuracy) UV stable wildlife protectors for source and load insulators External voltage sensors Junction box with all twist lock connections Junction box with twist lock connections for control cable and strain relief for module connections. 42 pin interface with additional 52b auxiliary contact (Form C type) and cable-disconnected alarm 3-phase ganged manual trip handle I. FACTORY PRODUCTION TESTS Each individual recloser shall undergo a mechanical operation check verifying contact trip/close velocity, travel profile, timing and phase synchronisity. The recloser shall be AC hi-pot tested (power frequency withstand voltage) one minute phase-to-phase, phase-to-ground and across the open contacts. Circuit resistance shall be checked on all phases. Timing tests shall be conducted to verify TCC performance. System testing shall be performed on each Viper-LT with their respective matching control and any other site-ready add-on such as lightning arrester or potential transformers. p NEMA 4-hole, 2-hole and clamp style aerial lugs p Accusense Voltage sensor. J. STANDARD COMPONENTS The following shall be included as standard: 1. Lifting provisions 2. Grounding provisions 3. Operations counter for each phase located in the control 4. Manual trip and lockout handles with true mechanical block 5. SEL-651R control or VRC with SEL-351R4, SEL-351R3 Falcon, SEL-751A, or Beckwith M-7679 6. 32 pin control cable 7. One 52a auxiliary contact per phase 8. Triple Option trip/close capabilities 9. Solid dielectric cycloaliphatic epoxy modules with internal voltage sensors and multi-ratio CTs 10. Arrester mounting provisions (overhead applications only) 11. Junction box on the frame with a connectorized control cable 32-pin interface control cable with 1/4 twist lock connectors permit easy field installation. 42-pin interface. G&W ELECTRIC PAGE 7

G&W offers a complete line of smart distribution voltage equipment including: Lazer Automation Multiple levels of protection Open, flexible communication Pre-engineered, factory tested Transfer, loop, and network applications Solid Dielectric Switchgear To 38kV, 16kA interrupting Submersible vault and padmount Smart Grid / Lazer solutions Single phase and three phase Integral Visible Break Designs SF6 Insulated Switchgear To 38kV, 25kA interrupting Submersible vault and padmount Smart Grid / Lazer solutions Load and Fault Interrupting Solid Dielectric Reclosers To 38kV, 12.5kA interrupting To 27kV, 16kA interrupting Overhead, substation and padmount Smart Grid / Lazer solutions Single phase and three phase Six voltage sensing available G&W Electric Company 305 W. Crossroads Pkwy Bolingbrook, IL 60440-4938 USA Tel 708.388.5010 Fax 708.388.0755 www.gwelec.com ISO 9001:2008 Certified ISO 14001:2004 Certified Catalog O-vlt14 September, 2016