CEILING CONCEALED LOSSNAY LGH-50RX3

Similar documents
CEILING CONCEALED LOSSNAY LGH-80RX3

CEILING CONCEALED LOSSNAY LGH-25RX3

20 C (68 F) 16 C (60.8 F)

/ LOSSNAY / LGH-RS2-E2

Installation Instructions Models LGH-F300, F470, F600RX5-E

The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.

Air duct switching damper

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

SPECIFICATION SHEET. C5000 ( cfm)

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

A. NU2035 HRV Specifications NU2035

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

CH5000 Heat Recovery Ventilator

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

REPLACEMENT PARTS MANUAL

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

REPLACEMENT PARTS MANUAL

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Engineering Data Book

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

Engineering Data Book

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Engineering Data Book

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: SH381 SH431 SH491. Contents. General Notes. Important

REPLACEMENT PARTS MANUAL

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1. General Notes. Contents.

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

technical data air conditioning systems MXS-B Multi Application Split Sky Air

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: W42A1 W42A1D W48A1 W48A1D W60A1 W60A1D. General Notes. Contents.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

Split-Sky Air RMX-JZ Super Multi Plus

FAN POWERED TERMINAL UNITS

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL WA302, WA372. Models: Contents. General Notes. Important.

REPLACEMENT PARTS MANUAL

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

DVM. Technical Data Book

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Model Number Structure

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH301 WH361. Models: Contents. General Notes. Important. Description

402s - Service Manual

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB387

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. Models: S38H1 W38H1 S43H1 W43H1 S49H1 W49H1 S61H1 W61H1 S38H1D S43H1D S49H1D S61H1D

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

D M S 760 C01 A A 1 1

REPLACEMENT PARTS MANUAL

Digital Inverter 4 series

Models: WL302, WL372. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CHP

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS. Models: W30H1 W36H1. Contents. General Notes. Important. Description

ERV. Technical Data Book. ERV for Europe (NASA, 50Hz, 60Hz)

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Technical Service Manual

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

High Static Pressure Duct Fan Coil Unit

ENERGY RECOVERY SYSTEM 60 HZ

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

ZHA/ZHB SERIES WARNING

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: W42A1 W42A1D W48A1 W48A1D W60A1 W60A1D. General Notes. Contents.

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Compact Four-way Cassette Type

Models: WA182, WA242. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Fault Codes. J control

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

Split-Sky Air FAYP-B Wall Mounted Unit

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

HEAVY DUTY POWER RELAYS FEATURES

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

VHIA High-Static Ducted Indoor Units - 60HZ

Prepared By : Checked By : Approved By : Page 1 out of 6

FCVC Series VERTICAL FAN COILS

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Transcription:

LGH-RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight Serial single communication (M-NET transmission) Air-to-air total heat (sensible heat + latent heat) recovery Partition, spacing plate-special treated paper Galvanized steel sheet Self-extinguishing urethane foam Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 units 222 mm dia.centrifugal fan Non-woven fabrics filter (Gravitational method 82 %) - C to 4 C, RH 8 % or less (- C (*) to +4 C, RH 8 % or less) Lossnay ventilation/bypass ventilation ()- switching 33 kg Power supply Single phase 22-24 V/ Hz Single phase 22 V/6 Hz Ventilation mode Lossnay ventilation Bypass ventilation Lossnay ventilation Bypass ventilation Fan speed Current [A].94-.9.89-.9.7-.6.9-.96.9-.93.8-.6.2..6.22..6 Power consumption [W] 24-22 93-24 23-42 26-228 96-22 2-42 262 23 3 263 228 3 Air volume [m 3 /h] [mmh2o].3 3 3..3 3 3. 2.4 3 2. 2.4 3 2. [L/s] [Pa] 6 97 3 6 97 3 2 6 83 2 2 6 83 2 Temperature recovery efficiency [%] 77 77 82 - - - 77 77 83. - - - Enthalpy recovery Heating 67 67 73 - - - 67 67 7 - - - efficiency (%) Cooling 6. 6. 68 - - - 6. 6. 7 - - - Noise (db) Measured at. m under the center of panel 32.-33. 3-3 23.-24. 33.-34. 3.-3. 23.-24. 32. 28. 23 33. 29. 23 Air outlets 4.-4. 38-39 29.-3. 4.-42. 38.-39. 3.-3. 4. 36. 29 4. 37. 29 Starting current Insulation resistance Dielectric strength Under.9/.7 A or less MΩ or more ( V megger) AC V minute Characteristic Curves Recovery efficiency (%) 9 Recovery efficiency (%) Hz 6 Hz 9 8 7 6 (mmh2o) 4 3 3 2 2 (Pa) 4 3 3 2 2 Temperature recovery efficiency Enthalpy recovery efficiency (Heating) Enthalpy recovery efficiency (Cooling) 2 3 4 6 7 (m 3 /h) 2 4 6 8 2 4 6 8 2 Air volume (L/s) 2 mm dia pipe length 6 m m 4 m 3 m 2 m m. The defrosting mode must be operated under - C or below. (Air supply fan drives 6 min. ON/ min. OFF) 2. The current, power consumption and efficiency are based on the above air flow rate. 3. The noise at the air outlets is the values at a 4 angle,. meters in front of the unit. 4. Fan speed can be switched between high and low. The main unit switch must be used to select the fan speed. 8 7 6 (mmh2o) 4 3 3 2 2 (Pa) 4 3 3 2 2 Temperature recovery efficiency Enthalpy recovery efficiency (Heating) Enthalpy recovery efficiency (Cooling) 2 3 4 6 7 (m 3 /h) 2 4 6 8 2 4 6 8 2 Air volume (L/s) 2 mm dia pipe length 6 m m 4 m 3 m 2 m m SPECIFICATIONS 7-Jun.- LGH-RX3 NUMBER No. ND6 /4

Drawings and Dimensions Position where duct direction is changed Air exhaust fan 24 79 Damper plate Ceiling suspension fixture EA (exhaust air) RA (return air) 6 74 48 OA (outside air) SA (supply air) 9 Maintenance space for heat exchanger, air filters, and fans 6 or more to 2 24 Inspection opening 22 Power cord opening Air supply fan Control box 4 37 Maintenance cover Heat exchanger (Lossnay core) -performance filter (sold separately attachment position) ( ) Position where Ceiling suspension fixture is changed 79 888 79 24 Ceiling suspension fixture φ 92 φ 28 Air filters UNIT mm SCALE N.T.S. If condensation is expected to form, heat up the fresh outside air using a duct heater, etc. 2. An inspection port (4 4 6 6 mm) must be installed on the filters and Lossnay cores removing side. 3. The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. The two indoor ducts may be covered with heat-insulating if Lossnay is to be installed in the circumstance of higher temperature in summer. 4. Installing the duct damper is preferred also to prevent the outdoor air introduced to room if there has strongthern wind, when the unit operates or stops.. The outside ducts must be tilted at a gradient (/3 or more) down toward the outdoor area from Lossnay unit. DRAWINGS AND DIMENSIONS 7-Jun.- LGH-RX3 NUMBER No. ND6 2/4

Schematic NOTE M2 Supply fan motor M Exhaust fan motor Operation monitor output MAX MIN AC 24 V 2A AC 22 V ma DC 24 V 2A DC V ma Malfunction monitor output MAX MIN AC 24 V A AC 22 V ma DC 24 V A DC V ma. TM, TM2, TM3, TB shown in bold lines are field work. 2. Breaker should be provided by the customer. 3. Be sure to connect the grounding wire. CN BLACK YELLOW CN9 SW3 C 9 8 7 SW4 C TM3 X7 X8 TM2 CN8- X3 X4 X X2 2 3 4 6 A B S 2V or 24V DC Mr.Slim (non-polar) 3 Uncharged a-contact RED SW2 SA External control input CN8-2 SW SA2 PZ-4SLB ZNR2 DSA Fuse S 2V 6.3A ZNR SW CN32 Transmission cable Lossnay unit MAX units C GREEN/YELLOW CN X TB 3 CN7 6 CN2 CN CN6 S2 PZ-2SF RED TM PE N L YELLOW CN6 TR Shield wire TH(OA) TH2(RA) CN6 Breker M-NET-transmission cable N L Power supply 22-24 V ~Hz 22 V ~6Hz LS GM Unchaged a-contact / select connector Symbol explanation M : Motor for exhaust fan M2 : Motor for supply fan C : Capacitor GM : Motor for Bypass movement LS : Microswitch TH : Thermistor for outside air TH2 : Thermistor for return air SW : Switch (Main/Sub change) SW2, : Switch (Function selection) SW3 : /E.high select switch (Exhaust fan) SW4 : /E.high select switch (Supply fan) TM : Terminal block (Power supply) TM2 : Terminal block (Transmission cable and external control input) TM3 : Terminal block (Monitor output) * TB : Terminal block (M-NET Transmission cable) S, S2 : Connector (Power supply) TR : Control circuit transformer X7 : Relay contact (For operation monitor output) X8 : Relay contact (For malfunction monitor output) CN : Connector (Transformer primary) CN2 : Connector (Transformer secondary) CN : Connector (Thermistor) CN6 : Connector (Microswitch) CN7 : Connector (Motor for Bypass operation) CN8- : Tab connector (Fan motor) CN8-2 : Tab connector (Fan motor) CN9 : Connector (Fan motor) CN : Connector (Fan motor) CN6 : Connector (/ switch) CN32 : Connector (Remote control selection) * SA * SA2 : Address setting rotary switch ( digit) : Address setting rotary switch ( digit). This must be used with Mitsubishi Electric Air-Conditioner Network System. (MELANS) 2. External control input (TM2) is impossible to use on the Lossnay addressed to Sub (SW) unit. 3. PZ-4SLB and PZ-2SF cannot be used simultaneously. MARK : Indicates terminal block : Connector : Board insertion connector or fastening connector of control board SCHEMATIC 7-Jun.- LGH-RX3 NUMBER No. ND6 3/4

NC Curves Hz Background noise : 2dB or less (A range) Measurement site : Anechoic chamber Operation conditions : Lossnay ventilation.m Measurement point Octave band sound pressure level (db) 9 8 7 6 4 3 2 Extra-high NC-7 NC-6 NC- NC-4 NC-3 NC-2 62. 2 2 k 2k 4k 8k Octave band centre frequency (Hz) 6Hz Background noise : 2dB or less (A range) Measurement site : Anechoic chamber Operation conditions : Lossnay ventilation.m Measurement point Octave band sound pressure level (db) 9 8 7 6 4 3 2 Extra-high NC-7 NC-6 NC- NC-4 NC-3 NC-2 62. 2 2 k 2k 4k 8k Octave band centre frequency (Hz) NC CURVES 7-Jun.- LGH-RX3 NUMBER No. ND6 4/4