Float Level Control Kits

Similar documents
INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Badger Truck Refrigeration, Inc. Warranty Policy

Installation Instructions Receiver Rack (Part # 7700) Universal Application

Sanitary Yard Hydrant Installation Instructions

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

MANUAL NO CREATED: 08/08/2012 MMH REV A STEEL COMPANY R 65 BUSHEL MINI-BIN PARTS AND ASSEMBLY MANUAL

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

UltraPrecise Auto Top Off Liquid Level Controller (LLC-UPLC-ATO)

SOLAR DASH CHARGING SYSTEM USER GUIDE

Effective June 1, 2013 This guide supersedes all previous versions

Terms and Conditions

Raydot LLC 24 Actuator (115 VOLT)

Sanitary Roof Hydrant Installation Instructions

INSTALLATION INSTRUCTION & OWNER S MANUAL

2015 & 2018 Fender Brace Installation Instructions

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

PVI 60KW, PVI 82KW, PVI 95KW

Operating and Installation Instructions

Models P, P, P, , DANGER

Smoke Leak Locator. User Manual. For Models: Pro S 25, Pro S 75, Pro S 500T, Pro S 600T, Pro S 1000HD. Ceramic Heating Technology

Parts Manual Vermeer/ McLaughlin Mud System 230P

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Parts Manual Vermeer/ McLaughlin Mud System 230P

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

INSTALL GUIDE Silverado/Sierra L/6.2L

HYDRAULIC POWER PACK

Users Manual Certified Series Direct Drive Pump 1-7 LPM

SUPERPLUS WATER FILTRATION SYSTEM

10 Year Limited Warranty

Power. On Your Terms.

Universal Bevel Drives Service Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Series 2100 Operating Instructions

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

USER S OPERATING AND INSTRUCTION MANUAL

December 1, 2011

92831 TEL: (714) FAX:

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

OWNERS MANUAL JANUARY 2007 ISO

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

2V1-3V1 SERIES SOLENOID VALVE

OWNERS MANUAL JANUARY 2007 ISO

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

ADI-125/750 ADI-125/1500 ADI-125/2500

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

DC to AC Power Inverters

22421 SPORT SWAY BAR SET TOYOTA COROLLA

Installation Instructions / Warranty

DC to AC Power Inverters

SUPREME FEEDER MANUAL NO REV A / 09/02/ DOOR HOG FEEDER ASSEMBLY INSTRUCTIONS

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Installation and Maintenance Instructions

16385 Steering Tie Rods Chrysler A-Body

TL-105-D COLUMN HEATER

SD8/SD9 Straight Dozer Blade

MityFlex Peristaltic Pump

STC 2P025 Series Solenoid Valve

Warranty Information North America

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

INSTALLATION OF HOTCHKIS FRONT STABILIZER BAR

TBM Series 3-Way Ball Valve

Sport Sway Bar Kit UP SCION xb

Type Flexair Pneumatic Pressure Control Valves

ATD-7384W 12-Ton Bottle Jack Owner s Manual

Installation Instructions

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

MIL-24/2600Q MIL-24/3200DQ

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

INSTALL GUIDE Jeep Wrangler JK 3.6L V6

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

SPL HICAS ELIMINATOR KIT

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment

CRD610 Automatic Fitting Inserter

Camaro / Firebird. Please read the following key points before installing this kit.

Installation Instructions

R E A D T H I S F I RST SAW USER GUIDE MODEL SVC4

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

P/N# Performance Lowering Springs Installation Instructions

INSTALL GUIDE Ford F L

Thermaltake Warranty / Support Information

Installation Instructions

Air Compressor. Owner s Manual

1313 LOWER TRAILING ARMS CHEVROLET B-BODY

Transcription:

Float Level Control Kits ASOFK, SPFK and FLC SpectraPure Inc. assumes no responsibility for water damage due to leaks. It is the user s responsibility to determine that the system is leak-free. INSTALLATION AND OPERATING MANUAL REV 12/22/2008

SpectraPure TABLE OF CONTENTS Kit Information Terms & Conditions...3 Warranty...4-5 What Does The Kit Do?...6-7 Installation Installation of Aso Valve & Check Valve...8-9 Push Fitting Installation...10 Assembly Instructions for Float...11 Typical Assembly...12 COPYRIGHT 2002-2009 BY SPECTRAPURE INC ALL RIGHTS RESERVED No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of SpectraPure Inc. 2 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SpectraPure TERMS AND CONDITIONS TERMS AND CONDITIONS OF SALE 1. Shipping charges on units or parts submitted to our facility for repair or replacement must be borne by the registered purchaser. After repair or replacement, the factory will return the unit or part freight prepaid to the customer. 2. We assume no warranty liability in connection with our equipment other than as herein specifi ed. 3. This warranty is in lieu of all other warranties expressed or implied, including warranties of fi tness for a particular purpose. 4. We do not authorize any person or representative to assume for us any other oblligation on the sale of our equipment. This is the exclusive remedy and liability for consequential damages under any and all warranties which are excluded to the extent exclusion is permitted by law. 5. Proof of original purchase date must accompany all warranty claims. 6. SpectraPure, Inc. reserves the right to change prices without notice when necessary. All prices in the catalog are quoted in US dollars. 7. Claims for error in quantity or condition must be made within 10 days of receipt of material. SpectraPure, Inc. will not be responsible for any claimed shortages not reported within 10 days. Returns other than warranty claims may be subject to 20% restocking fee. 8. SpectraPure, Inc. cannot be held liable for damage or loss to a shipment by a freight carrier. Check shipment for damage before acceptance or note on freight bill subject to inspection for concealed damage. Consignee must file claim. SpectraPure, Inc. will offer as much assistance as possible. 9. A complete credit check is required prior to shipping on a Net 30 or C.O.D. - CUSTOMER CHECK ACCEPTABLE basis. In the interim period during which credit references are being evaluated, all orders must be shipped C.O.D. - CERTIFIED FUNDS (cash, cashiers check or money order). 10. All returned checks (due to insufficients funds or closed accounts) will be subjected to a $25 penalty charge. Invoices on Net 30 accounts not paid within 30 days of shipment will be considered delinquent and will accure Finance charges at the rate of 1.5% per month (18% per annum). SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com 3

SpectraPure WARRANTY TWO YEAR LIMITED WARRANTY Effective on products purchased after March 10, 2005. SpectraPure, Inc. warrants the product to the original owner only to be free of defects in material and workmanship for a period of two years from the date of receipt. SpectraPure s liability under this warranty shall be limited to repairing or replacing at SpectraPure s option, without charge, F.O.B. SpectraPure s factory, any product of SpectraPure s manufacture. SpectraPure will not be liable for any cost of removal, installation, transportation or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by SpectraPure are subject to the warranty provided by the manufacturer of said products and not by SpectraPure s warranty. SpectraPure will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair or, if the product was not installed in accordance with SpectraPure s or other manufacture s printed installation and operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. SpectraPure will not be responsible for any consequential damages arising from installation or use of the product, including any water or mold damage due to flooding which may occur due to malfunction or faulty installation, including, but not limited to failure by installer to over- or under-tighten fittings, housings, and/or pushstyle fittings, or improper installation of push-style fittings. Consumable items such as pre filters and membranes are not covered under the 2 year warranty. SpectraPure warrants (pro-rated) the performance of tested SpectraSelect RO membrane elements only, for one year from date of receipt by the buyer, providing that the loss of performance was not caused by fouling, neglect or water conditions exceeding the feed water parameters listed in the applicable product manual (refer to detailed membrane warranty information). SpectraPure will, on confirmation of loss of performance during the warranty period, credit the pro-rated amount of the current catalog price of the element. The disposable filters and cartridges are not covered under the warranty. To obtain service under this warranty, the defective system or components must be returned to SpectraPure with proof of purchase, installation date, failure date and supporting installation data. Any defective product to be returned to the factory must be sent freight prepaid; documentation supporting the warranty claim and a Return Goods Authorization (RGA) number must be included. SpectraPure will not be liable for shipping damages due to the improper packaging of the returned equipment and all returned goods must also have adequate insurance coverage and a tracking number. 4 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SpectraPure SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, proliferation, spread or any activity of fungus, wet or dry rot or bacteria. Such loss or damage is excluded regardless of any other cause or event that contributes concurrently or in any sequence to the loss. We will not pay for loss or damage caused by or resulting from continuous or repeated seepage or leakage of water, or the presence or condensation of humidity, moisture or vapor, that occurs over a period of 14 days or more. Fungus and fungi mean any type or form of fungus or Mycota or any by-product or type of infestation produced by such fungus or Mycota, including but not limited to, mold, mildew, mycotoxins, spores, scents or any biogenic aerosols. SpectraPure will not be liable for any incidental or consequential damages, losses or expenses arising from installation, use, or any other causes. There are no expressed or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. * The two year limited warranty does not apply to consumable items, including but not limited to, filters and cartridges unless specifically stated above Feed water requirements* Minimum Operating Pressure: 40 psi (2.75). Maximum Operating Pressure: 80 psi (6.9 bar). *Most municipal water supplies meet the above requirements.* SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com 5

SpectraPure KIT INFORMATION WHAT DOES THE KIT DO? The Float Level Controller (FLC) provides an economical way to automatically fill open reservoir storage tanks. The Automatic Shut-Off (ASO) valve, in conjunction with the float valve, check valve and mini-bladder tank, provides positive and complete shut-off of the waste water and product water lines, thus conserving water when the system is not in use. The Automatic Shut-Off Kit (ASOFK) is most often used in conjunction with a Drinking Water System, which already includes a pressurized bladder tank. An optional float kit is needed for filling each additional sump or reservoir. Our Float Kit (SPFK) includes a stainless steel float valve and union Tee. The installation of the float valve requires a 9/16 mounting hole in the tank or reservoir. Note: The Float Level Controller is not recommended for evaporation replacement in aquariums. For these applications, we recommend either our SpectraPure Single Tank Liquid Replenisher (LLC-S-115) or Multiple Tank Liquid Replenisher (LLC-M-115). ASOFK Kit: Auto Shut-Off (ASO) Valve Pressure-operated device that shuts off water supply to RO membrane when the product line pressure equals 2/3 of the supply line pressure. 1# Check Valve Prevents pressure in product water line from leaking back into the RO membrane. Float Valve Installed in conjunction with ASO Valve, shuts off product water going to open reservoir. FLC Kit: Everything in the ASOFK Kit plus: Mini-Bladder Tank Provides beneficial back-pressure for smoother operation of ASO Valve. 1/4 Ball Valve Convenient shut-off control for individual reservoirs SPFK Kit: Float Valve Shuts off product water going to additional reservoir. 1/4 Union Tee Allows more than one vessel to be filled. 6 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SpectraPure KIT INFORMATION Fig. 1: ASOFK Components FLOAT VALVE ASO VALVE CHECK VALVE Fig. 2: FLC Additional Components MINI BLADDER TANK For unattended filling of tanks, reservoirs and storage containers Positive shut-off; completely shuts off all waste & product water BALL VALVE Use for the automatic filling of multiple open reservoir storage tanks Reservoirs can be located any distance away from the RO or RO/DI system SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com 7

SpectraPure INSTALLATION Installation of ASO & Check Valves 1. Locate the Black Tube between the Carbon Filter and the Membrane. 2. Cut the Black Tube in half. 3. Insert the cut end from the Carbon Filter into the IN Port of the ASO Valve. 4. Insert the cut end from the RO Membrane Housing into the OUT Port of the ASO Valve. 5. Locate the Blue Tube (product water) that leaves the RO Membrane Housing. 6. Cut the Blue Tube 1 from the membrane housing. 7. Using the 1 lb Check Valve, reconnect the two cut ends with the arrow pointing away from the membrane. 8. Position the Blue Tube along side the ASO Valve to determine where the blue tube needs to be cut. Then cut the blue tube and reconnect the two cut ends with the two remaining ports of the ASO Valve. IMPORTANT:. This kit does not have a back-up shut-off device. It is the user s responsibility to determine that the system is working properly for a period of 72 hours, after installation. If the float fails, SpectraPure is not responsible for water damages. As an optional over-flow prevention, you could connect a bulk-head fitting to a drain line where it would act as an overflow to drain, should the float fail. (THIS KIT IS NOT RECOMMENDED FOR EVAPORATION TOP-OFF) 8 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SpectraPure INSTALLATION Fig. 2: Installation of ASO and Check Valve For Single Membrane Systems OUT port IN port Black Tubing from Carbon Filter ASO Valve Check Valve Product Water in Blue Tubing to Reservoir, Bladder Tank, DI cartridge, etc. To Drain Flow Restrictor Inside Yellow Tubing Y Connector Fig. 3: Installation of ASO and Check Valve Back View of Dual Membrane Systems 2nd Membrane 1 LB Check Valve Flow Restrictor Inside Yellow Tubing 1st Membrane Black Tuing from Carbon Block Filter IN port OUT port Product Water IN Blue Tubing to Reservoir, Badder Tank or DI cartridge SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com 9

SpectraPure INSTALLATION INSTALLATION INSTRUCTIONS FOR FLOAT 1. Drill a 1/2 hole into your sump or reservoir: *If the thickness of the sump is too thick for the Float to install properly, you need to counter-bore the hole. - NOTE: If you are installing the Back-up Safety Float onto an acrylic tank we recommend using a new Fostner Bit to reduce the chance of cracking the acrylic. 2. (REFER TO DIAG) Remove the Compression Nut from the float body. 3. Insert the 1/4 Blue Tubing into the 1/2 Compression Nut with the threads towards the end of the tube. 6. Unscrew the Nut from the float body. 7. Insert the float body and washer into the 1/2 hole and tighten the Nut, which securely tightens the float to the tank wall. 8. Push the Compression Nut towards the end of the tubing and screw the Compression Nut back onto the float body. 9. To tighten, use one 1/2 wrench on the flats of the plasic threads and another 1/2 wrench on the compression nut. NEW ADJUSTABLE FLOAT STANDARD FLOAT. 10 * Kit includes the new adjustable float SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SpectraPure INSTALLATION WASTE WATER (YELLOW TUBING with FLOW RESTRICTOR) END VIEW OF RO MEMBRANE HOUSING ASOFK AND FLC INSTALLATION DIAGRAM PRODUCT WATER (BLUE TUBING) SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com 11

SpectraPure THIS PAGE IS BLANK 12 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281