Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Similar documents
Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM 170

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Operating instructions Solenoid interlock AZM About this document. Content

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

ZB0050 / ZB0051 ZB0070 / ZB0071

Emergency pull-wire, Belt-alignment, Slack-wire switches. Automation. Catalogue // SYSTEMATIC CONTROL SWITCHGEAR

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Ex m Solenoid Operator Type 0519

AZM 161SK 12/12RKED/TU 024

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

Solenoid interlock AZM 200 The non-contact interlock.

Operating Instructions

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Safety door-handle system STS

Operating Instructions

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety rope switches with reset for emergency stop

Technical data. Standards: IEC/EN BG-GS-ET-15

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Installation and Operating Instructions

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

LK Position Switches TECHNICAL DATASHEET.

Safety rope switch with reset for emergency stop

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

FL series position switches

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Installation and Operating Instructions

Floor and fine adjustment switches

Operating Instructions

EStrong-series Emergency Stop

Safety rope switch without reset for simple stop

Safety Sensor CSS 180 Product Information

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Operating Instructions

Support T10552 T10595 T40386

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Installation manual wall-mounted distributor

Operating Instructions

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Safety switches for hinges

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Datasheet - MV8H Y

Technical Data. Dimensions

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

HST -LS Interlocking device (Translation of Original Manual)

OPERATING INSTRUCTIONS

Installation manual portable distributors

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 8

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Swing Piston Compressors and Vacuum Pumps

Safety switches with solenoid and separate actuator

Position Switches Series 8074/2

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Pneumatic Axial Fan Type Tech. Doc. No. 802

Safety switches with solenoid and separate actuator

Door locking devices. 4 Schmersal Industrial Switchgear

Installation and Operating Instructions Magnetic Vibrator MR 1

Safety switches with separate actuator

Linear Luminaire with LED

Water level controller and limiter

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Transcription:

Pull-wire emergency-stop switches 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. the operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel ll operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. x.000 / 11.2017 / v.. - 101212127- / D / 2017-11-13 / E-Nr. 8370 Content 1 bout this document 1.1 Function...1 1.2 Target group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 ppropriate use...1 1.5 General safety instructions...1 1.6 Warning about misuse...1 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 Special versions....2 2.3 Purpose...2 2.4 Design/operating principle...2 2.5 Technical data...2 2.6 Safety classification...2 3 Mounting 3.1 General mounting instructions...3 3.2 Dimensions...3 4 Rear side Electrical connection 4.1 General information for electrical connection....4 4.2 Contact variants....4 5 Set-up and maintenance 5.1 Functional testing....4 5.2 Maintenance...4 6 Disassembly and disposal 6.1 Disassembly....4 6.2 Disposal...4 7 EU Declaration of conformity 1.4 ppropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant. The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1.6 Warning about misuse In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. 1

Pull-wire emergency-stop switches 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 2. Product description 2.1 Ordering code This operating instructions manual applies to the following types: -➀-3D No. Option Description ➀ 11 1 NO / 1 NC 13 1 NO / 3 NC 22 2 NO / 2 NC 02 2 NC 04 4 NC Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive and the Explosion Protection Directive is maintained. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Purpose The emergency stop switch meets the requirements of ISO 13850, IEC/ 60947-5-1 and IEC/ 60947-5-5. Pull-wire emergency stop switches are used on machinery and plants in explosion-endangered areas of Zone 22 equipment category 3D, where triggering the emergency stop command must be enabled at arbitrary points on the wire run. The installation and maintenance requirements to the standard series 60079 must be met. If the tensioned pull-wire is pulled or in case of wire breakage, the switching function of the pull-wire emergency stop switch is activated. (refer to image 1) Image 1: position indication and actuation 2.4 Design/operating principle The pull-wire emergency stop switches are brought into the operational condition by the proper pre-tensioning of the wire. Up to two switching elements located on the inside of the switch have either 2 or 4 contacts, whereby the NC contacts are closed and the NO contacts are opened in tensioned condition. F 1 0 0 fter actuation of the emergency stop function, a latching mechanism maintains the stop command until the switch is released by pushing the blue reset button. Prior to the reset of the emergency stop signal, the reason why the switch has been actuated must be determined. The switch can only be reset if the switch is correctly pre-tensioned (position indication in central position, refer to image 1). The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards. Conditions for safe operation The specific ambient temperature range must be observed. The user must provide for a protection against the permanent influence of UV rays. 2.5 Technical data Equipment category: L II 3D Ex protection: Ex tc IIIC T100 C Dc Standards: IEC/ 60947-5-1, IEC/ 60947-5-5, ISO 13850, 60079-0, 60079-31 Enclosure: zinc die-cast, enamel finish Cover: Steel Protection class: IP67 to IEC/ 60529 Contact material: Silver Max. impact energy: 7 J Contact type: 1 NC / 1 NO or 2 NC / 2 NO or 3 NC / 1 NO or 2 NC or 4 NC Switching system: IEC 60947-5-1 snap action, NC contacts with positive break Connection: screw terminals Cable section: max. 2.5 mm² (incl. conductor ferrules) Cable entry: 3 M20 Rated impulse withstand voltage U imp : 6 kv Rated insulation voltage U i : 500 V Thermal test current I the : 4 Utilisation category: C-15 / DC-13 Rated operating current/voltage I e /U e : 4 / 230 VC; 1 / 24 VDC Max. fuse rating: 6 gg D-fuse to IEC/ 60269-1 mbient temperature: 20 C +55 C Mechanical life: max. 1 million operations Wire length: max. 75 m depending in relation to the range of ambient temperature (see image 3) Features: wire pull and breakage detection Cable cross-section of the cable glands: min. Ø 7 mm; max. Ø 12 mm Cable glands: L II 2GD Tightening torque: - Cable gland: 8 Nm - Cover screws: min. 0.6 Nm, max. 0.9 Nm 2.6 Safety classification Standards: ISO 13849-1 B 10D NC contact: 100,000 Service life: 20 years MTTF D B10D dop x hop n x 3600 s/h op 0,1 x n op t cycle (Specifications can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) 2

Pull-wire emergency-stop switches 3. Mounting 3.1 General mounting instructions Fitting is only authorised in a de-energised condition The fitting may only be carried out by authorised personnel. The pullwire emergency stop switch is fitted by means of two screws (distance of the dril holes 40 mm or 48 mm), so that a release by hand can be realised without hazard. The component must be fitted so that the entire length of the wire can be viewed from the position of the switch. In accordance with IEC/ 60947-5-5, the maximum perpendicular traction force to be exercised on the wire in order to activate the emergency pull-wire switch is 200 N, the maximum deflection is 400 mm. Sufficient space must be provided so that the required actuating deflection can be reached. For tensioned span lengths up to 10 m, intermediate wire supports are required every 3 to 5 m. To avoid resonance vibrations in the wire on machines with high vibrations, it is recommended to realise the individual support length differently. ssembly: refer to image 2. lm [] 75 65 55 45 35 25 15 5-30 -20-10 0 10 20 30 40 50 60 70 T C [] without tension spring with tension spring Image 3: temperature-dependent maximum wire length with or without tension spring The pull-wire must be fixed to the ring and then be pre-tensioned until the position indication is in the central position (refer to image 1). s the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. fter that, the wire must be re-tensioned (see image 4). Please observe the recommendations regarding maximum impact energy, actuating speed and tightening torque in the technical data. 3-5 m max. 75 m Image 4: deformation of the wire thimbles 0,1 m 64 2 3 6 5 6 1 3-5 m 46 9 2 3 0,1 m 8 2 3 1 8 9 7 2 3 Image 2: mounting of the components In order to ensure an optimal operation safety and to save time during fitting, we recommend using the wire rope and the combined fixing and tensioning system from Schmersal. lternatively, wire thimbles and wire clamps can be used in conjunction with a tensioner. In this case, the red PVC sheet must be removed in the clamp area prior to installing the wire rope. 3.2 Dimensions ll measurements in mm. Key 1 Pull-wire with red PVC sheath Ø 5 mm (steel core: Ø 3 mm) 2 Eyebolt 3 Nut 4 Wire clamp 5 Tensioner 6 Wire thimble 7 Shackle 8 S900 wire tensioner 9 Tension spring RZ-2041 B Position indication Reset button We recommend the use of the RZ-2041 tension spring to attenuate the effects of temperature variations. Due to the thermal expansion behaviour of the wire, the maximum authorised wire length is determined by the ambient temperature range (refer to image 3). 10 12 B 48 40 27 Ø6.5 133.4 71.5 M20x1,5 57 72 Ø19 221-237 Ø32.7 71.3 Legend: = Position indication B = Reset-button 3

Pull-wire emergency-stop switches 4. Rear side Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. Cable glands (included in delivery) are only authorised for permanent cables. The constructor must provide for the necessary strain relief. To open the cover, the cover screws must be loosened. When wiring, please ensure that no cables are located within the range of the lever system and the pushbutton. fter wiring, the inside of the switch must be imperatively cleaned (e.g. removal of cable residues), considering that foreign bodies can affect the switching behaviour. Screw back the cover after that and uniformly tighten the cover screws. The external potential equalisation terminal is to be connected in accordance with 60079-14 section 6.3. 4.2 Contact variants Contact variants are shown in a de-energised condition with actuator inserted. -11-3D -02-3D -13-3D 5. Set-up and maintenance 5.1 Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1. Check the correct fitting of the pull-wire emergency stop switch 2. Check cable entry and connections in a de-energised condition 3. Check the switch enclosure for damage 4. Check the functionality of the switch by actuating the wire 5. Check the cable tensioning by means of the position indicator 5.2 Maintenance In case of correct installation in accordance with the above-described instructions, the component requires little maintenance. For use in extreme conditions, we recommend routine maintenance including the following steps: 1. Check the correct fitting of the pull-wire emergency stop switch 2. Check the functionality of the switch by actuating the wire 3. Check cable entry and connections in a de-energised condition 4. Remove particles of dust and soiling 5. Check the wire tension through the wire position indication and check the wire and the wire guides for damages and proper fitting Do not open the device when live. 21 13 22 14 21 11 22 12 21 22 21 22 13 S1 14 11 12 S2 Damaged or defective components must be replaced. For explosion protection reasons, the component must be exchanged after max. 1 million operations. -22-3D 21 22 21 22 13 S1 14 13 14 S2-04-3D 21 22 21 22 11 S1 12 11 12 S2 6. Disassembly and disposal 6.1 Disassembly The safety switchgear must be disassembled in a de-energised condition only. Key Positive break contact 6.2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. 4

Pull-wire emergency-stop switches 7. EU Declaration of conformity EU Declaration of conformity Original K.. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: L II 3D Ex tc IIIC T100 C Dc Type: See ordering code Description of the component: Pull-wire emergency stop switch for safety applications Relevant Directives: Machinery Directive Explosion Protection Directive (TEX) RoHS-Directive 2006/42/EC 2014/34/EU 2011/65/EU pplied standards: DIN 60947-5-1:2010, DIN 60947-5-5:2015, DIN ISO 13850:2016, 60079-0:2012, 60079-31:2014 Notified body, which approved the full quality assurance system, referred to in ppendix IV, 2014/34/EU: TÜV Rheinland Industrie Service GmbH m Grauen Stein 51105 Köln ID n : 0035 Person authorised for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, March 29, 2017 -C- uthorised signature Philip Schmersal Managing Director Die aktuell gültige Konformitätserklärung steht im Internet unter www.schmersal.net zum Download zur Verfügung. 5

K.. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Telefon +49 - (0)2 02-64 74-0 Telefax: +49 - (0)2 02-64 74-1 00 E-mail: info@schmersal.com Internet: http://www.schmersal.com